Define Instruments OVP-100 Operating Manual

OVP -100
Over Voltage Protection
This over voltage protection unit is characterised by its high level of protection, concentrated in a compact space. It is suitable for installing in the narrowest of places, making it ideal for automated process industrial and building service systems.
Two Stage Protection:
Gas discharge tubes provide the first stage
Transient voltage supressors provide the second stage
Gas discharge tubes 8x20μs: 5000A. 10x1000μs: 10A. DC spark voltage 60~90V at 100V/s. Impulse spark over voltage <600V at 1kV/μs.
Transient voltage suppressors 10x1000μs: 600W. Response time <5ns from 0~41V. Stand o voltage 33V typical.
Operating temperature 0 to 60°C (32 to 140°F)
Storage temperature -20 to 80°C (-4 to 176°F)
Operating humidity 5–85% RH max
EMC compliance Emissions: EN55022-A. Immunity: EN
50082-1 (<1% e ect FSO typical).
Leakage current 10μA at 24V DC
Casing 79 x 20 x 70mm (3.11 x 0.79 x 2.76") 35mm DIN rail
1
Wiring
2
1
KEY
EARTH
1
− OUTPUT
5
3
4
3750V ISOLATION BARRIER
5
6
2
3
4
EARTH
− INPUT
+ INPUT
+ OUTPUT
6
EARTH
7
EARTH
8
NOTE
USE INSTRUMENTATION CABLE WITH SCREEN EARTH AT ONE END ONLY
78
MIN 300MM DISTANCE REQUIRED BETWEEN SIGNAL AND POWER CABLES
Cables
Austral Cable B5102ES standard for 2-wire current loop
Austral Cable B5103ES standard for 3-wire transmitters & RTDs