PRO-PRC-MAN-16V04 (0719) Copyright © 2016 De ne Instruments
12
C _ _ _ DISPLAY TIME IN SECONDS scrolls across and toggles with the current
selection. This setting is only used for AUTO display (see 5.3B), and is the pause
time (in seconds) between variables as they cycle on the display. Use the
and
buttons to adjust this value as required, and then press .
D _ _ _ DECIMAL POINT/ROUNDING SETUP scrolls across and toggles with SKIP.
Press
now to skip decimal point and rounding setup, or use the and
buttons to select a channel: CH 1, CH 2, CH 3, CH 4 or CH AVE. Then press
.
If you selected a channel (or CH AVE), continue to 5.3E now.
If you selected SKIP, skip to 5.3H now.
E _ _ _ DECIMAL POINT scrolls across the display and toggles with the current
decimal point position for the channel selected in 5.3D . Use the
and but-
tons to select: NONE, 0.1, 0.01, 0.001, 0.0001 or 0.00001. Then press
.
F _ _ _ ROUNDING scrolls across and toggles with the rounding for the selected
channel. Use the
and buttons to select: NONE, 2, 5, or 10. Press .
Rounding is in display counts and is not in uenced by decimal point position.
G _ _ _ DECIMAL POINT/ROUNDING SETUP scrolls across the display and tog-
gles with SKIP. You are now back at 5.3D. To set up another channel, proceed
through steps 5.3D–G again. To continue to 5.3H, select SKIP and press
.
H _ _ _ PEAK/VALLEY SOURCE scrolls across the display and toggles with the
currently selected peak and valley source. Use the
and buttons to select:
DISP, CH 1, CH 2, CH 3, CH 4 or CH AVE, and then press
.
DISP will use the current display source (selected in 5.3B) for the peak/valley display. (If your
display source [5.3B] is set to either 'PEAK' or 'VALLEY', then 'DISP' will not appear as an op-
tion, as this would create a circular reference.) CH AVE will use the channel average value.
Peak and valley can be viewed or reset via the main display using the front panel shortcuts (see
2.3), or reset via the rear pins (see 3.6).
I _ _ _ SELECT NUMBER OF CHANNELS FOR AVERAGE DISPLAY scrolls across
and toggles with the number of channels to be averaged to produce the CH
AVE value. Use
and to select: NONE, 2 CH, 3 CH or 4 CH, and press .
CH AVE is an internally calculated value which is created by averaging 2, 3 or 4 of the input
channels, as selected above. The CH AVE value is stored by the controller and can be used as
the default view for the operational display, or as a source for analog output, serial output or