Introduction
Introduction
The PosiTest HHD Verifier is a calibrated high voltage meter used to verify
operating voltage of ALL pulse type DC holiday detectors in the range from 500 to 35,000 Volts.
WARNING:
HHD Verifier and that the other end of the ground lead is connected to the ground
WARNING:
with bare hands while the probe is in contact with a high voltage source. Electrical shock could occur if operator touches the tip or shield with bare hands while in use.
WARNING:
Electrical shock could occur if the operator uses this equipment in damp, wet or rainy conditions.
IMPORTANT:
ALWAYS ensure that the ground lead is plugged into the PosiTest
DO NOT touch the TIP of the probe or the RED High Voltage Shield
DO NOT use this equipment in damp, wet or rainy conditions.
DO wear gloves and appropriate footwear
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
WARNING:
DO NOT use this equipment with high voltage power sources other
than high voltage holiday detectors. The PosiTest HHD Verifier has been
specifically designed to work with high voltage holiday detectors that have limited
power output. Since the maximum power dissipation of the PosiTest HHD Verifier
is 12.5 watts, connection to high power, high voltage sources such as mains supply
WILL overheat and damage the PosiTest HHD Verifier. DO NOT connect the
PosiTest HHD Verifier to an AC power outlet.
Operating Instructions
Operating Instructions
IMPORTANT:
Before using the PosiTest HHD Verifier, ensure that a proper ground
is established between the holiday detector and the verifier.
Step 1. Before using the PosiTest HHD Verifier, ensure that a proper ground is
established between the holiday detector and the verifier. Ensure that the ground
lead is plugged into the PosiTest HHD Verifier and that the other end of the ground
lead is connected to the ground lead of the high voltage holiday detector that is being verified.
Step 2. Turn the PosiTest HHD Verifier on by pressing and releasing the power
button . Once powered on, the verifier continuously monitors the voltage on the probe end of the verifier. The verifier will update the display when the probe is touching an exposed electrode of a holiday detector. The voltage displayed on the verifier should match the voltage displayed by the detector within the combined tolerance of both units.
u For Pulse DC holiday detectors such as the PosiTest HHD, the verifier probe
tip can be left connected to an exposed electrode indefinitely with no concern. For best results, try to position the verifier probe perpendicular (90°) to the electrode on the holiday detector.
Securing the Ground Wire
Securing the Ground Wire
Battery compartment
Carabiner / wrist strap ring
A knot secures the Ground
Ground (earth) wire jack
2
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
(Earth) Wire to the ring
Accuracy, Calibration, and Adjustment
Accuracy, Calibration, and Adjustment
The PosiTest HHD Verifier is accurate to +/- 5% of the peak voltage presented to
the tip of the probe.
The PosiTest HHD Verifier is shipped with a Certificate of Calibration showing
traceability to a national standard. DeFelsko recommends customers establish calibration intervals based upon their own experience and work environment. A detector used frequently, roughly, or in harsh operating conditions may require a shorter certification interval than a gage used less frequently and handled with care. Based on our product knowledge, data and customer feedback, a one year certification interval from either the date of calibration, date of purchase, or date of receipt is a typical starting point.
PosiTest
PosiTest
PROBLEM: The PosiTest HHD Verifier is displaying a voltage different than
observed on the holiday detector
The PosiTest HHD Verifier is a Peak reading volt meter that can be used for ALL
Pulse DC applications.
When used with Pulse DC type holiday detectors, it is important to maximize the distance of the verifier tip to ground. This will reduce capacitive coupling to ground of the high frequency DC pulse.
Battery Replacement
Battery Replacement
Replace with 3 AAA alkaline batteries as shown.
HHD Verifier
HHD Verifier
Troubleshooting
Troubleshooting
3
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Technical Data/Specifications
Technical Data/Specifications
Pulse DC (30Hz) or DC
Input Impedance: 1Mohm Max Input Power Dissipation: 12.5 watts Range: 500–35,000 volts Resolution: 500–1,000 volts in 10 volt increments
1,000–35,000 in 100 volt increments
Accuracy: +/-5% Operating Temperature Range: -20° to 60° C (-4° to 140° F) Battery: 3 AAA alkaline Weight: 520 g (1.15 lbs.) with batteries and 1.8 m (6 ft) ground lead and clip Dimensions: 43x5x5cm(17”x2”x2”)
Returning for Service
Returning for Service
If you need to return the PosiTest HHD Verifier for service, describe the problem
fully and include reading results, if any. Be sure to include contact information including your company name, company contact, telephone number and fax number or email address.
Limited Warranty, Sole Remedy and Limited Liability
Limited Warranty, Sole Remedy and Limited Liability
DeFelsko's sole warranty, remedy, and liability are the express limited warranty, remedy, and limited liability that are set forth on its website:
© DeFelsko Corporation USA 2022. All Rights Reserved
This manual is copyrighted with all rights reserved and may not be reproduced or transmitted, in whole or part, by any means, without written permission from DeFelsko Corporation.
DeFelsko and PosiTest are trademarks of DeFelsko Corporation registered in the U.S. and in other countries. Other brand or product names are trademarks or registered trademarks of their respective holders.
Every effort has been made to ensure that the information in this manual is accurate. DeFelsko is not responsible for printing or clerical errors.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Loading...