DeFelsko ATVERIFY User manual

PosiTest
AT
Verifier
Instruction Manual v. 1.0
The PosiTest AT Verifier kit is ideal for checking the accuracy and operation of adhesion testers and is an important component in fulfilling both ISO and in-house quality control requirements.
The kit is ready to use with all PosiTest pull-off adhesion testers. All setup information has been preset by DeFelsko. No additional configuration is required or recommended. If the Smart Sensor Indicator (SSI) settings are mistakenly altered, see Reconfiguring the SSI Device (pg. 3).
Kit includes:
- Smart Sensor Indicator (SSI) Device
- Load Cell with steel 20mm Loading Fixture (dolly)
- Built-in rechargeable Lithium Ion Batteries
- Universal AC power adaptor/charger
- Instruction Manuals (2)
- Certificates of Calibration (2)
- Sample Certificate of Accuracy
- Measurement Uncertainty Worksheet
- Hard shell carrying case
Introduction
Introduction
Load Cell
Smart Sensor Indicator (SSI)
Load Cell to SSI Connection Cable
Loading Fixture
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
The PosiTest AT Verifier includes a Certificate of Calibration for the SSI device and one for the load cell. For information on returning your PosiTest AT Verifier for recertification, contact DeFelsko or your local dealer.
The PosiTest AT Verifier, with a valid Certificate of Calibration, can be used to check the accuracy of PosiTest Adhesion Testers. A sample Certificate of Accuracy is included.
The SSI device comes pre-configured for verification of PosiTest AT-M and AT-A pull-off adhesion testers. No additional configuration is required or recommended.
If the SSI is mistakenly altered, configuration can be restored by following the steps outlined in our Reconfiguration Guide. Contact DeFelsko for more information.
2 3
When verifying PosiTest AT Adhesion Tester accuracy, it is recommended that several verification points be tested. See the included Sample Certificate of Accuracy for recommended verification points.
Test results should fall within the combined accuracy of the PosiTest AT Adhesion Tester (+ 30 psi full scale) and PosiTest AT Verifier (pg. 4).
The included Measurement Uncertainty Worksheet and Sample Certificate of Accuracy documents have been pre-populated with data unique to your PosiTest AT Verifier.
If any of the verification points are outside of these combined accuracies, the PosiTest AT may require recalibration. Contact DeFelsko or your local dealer for information on returning your adhesion tester for recalibration.
Verification of Test Results
Verification of Test Results
Reconfiguring the SSI Device
Reconfiguring the SSI Device
Certification
Certification
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
The PosiTest AT Verifier includes a Certificate of Calibration for the SSI device and one for the load cell. For information on returning your PosiTest AT Verifier for recertification, contact DeFelsko or your local dealer.
The PosiTest AT Verifier, with a valid Certificate of Calibration, can be used to check the accuracy of PosiTest Adhesion Testers. A sample Certificate of Accuracy is included.
The SSI device comes pre-configured for verification of PosiTest AT-M and AT-A pull-off adhesion testers. No additional configuration is required or recommended.
If the SSI is mistakenly altered, configuration can be restored by following the steps outlined in our Reconfiguration Guide. Contact DeFelsko for more information.
When verifying PosiTest AT Adhesion Tester accuracy, it is recommended that several verification points be tested. See the included Sample Certificate of Accuracy for recommended verification points.
Test results should fall within the combined accuracy of the PosiTest AT Adhesion Tester (+ 30 psi full scale) and PosiTest AT Verifier (pg. 4).
The included Measurement Uncertainty Worksheet and Sample Certificate of Accuracy documents have been pre-populated with data unique to your PosiTest AT Verifier.
If any of the verification points are outside of these combined accuracies, the PosiTest AT may require recalibration. Contact DeFelsko or your local dealer for information on returning your adhesion tester for recalibration.
Verification of Test Results
Verification of Test Results
Reconfiguring the SSI Device
Reconfiguring the SSI Device
Certification
Certification
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
PosiTest
AT
Verifier
Instruction Manual v. 1.0
Introduction
Introduction
Load Cell
Smart Sensor Indicator (SSI)
Load Cell to SSI Connection Cable
Loading Fixture
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
Loading...