DeepSea Power & Light SeaLite Lumos 1000, SeaLite Lumos 2000 Operator's Manual

Page 1
®
SeaLite
®
Lumos
Operator’s Manual
DEEPSEA
POWER & LIGHT
T: (858) 576-1261
F: (858) 576-0219
4033 Rufn Road
San Diego, CA 92123- 1817 USA
SeaLite® Lumos
Record product serial number below as it appears on the nameplate.
Serial #
Pin-out
• Postive = Pin
• Negative = Pin
• Dimming (if applicable) = Pin
www.deepsea.com sales@deepsea.com
Original Instruction
REV 07/01/15
Page 2
Specication Overview
* Specications subject to change without notice.
SeaLite
1.87
47.5
1.69
42.9
2.47
62.6
2.40
60.9
1.59
40.3
.59
15
6.08
154.3
7.35
186.7
1.85 47
1.00
25.4
1.00
25.4
4X 1/4-20 UNC
OR
4X M6 x 1.0
[inch]
mm
®
Lumos
Operator’s Manual
Mechanical Specications
Housing
Port
Outer Diameter
Overall Length (w/o connector)
Weight in Air
Weight in Water
Environmental Specications
Depth Rating
Operating Temp.
Optical Specications
Colors
Lumens in Water
Color Temp/Wavelength
Beam Pattern
Electrical Specications
Lumos 2000 Lumos 1000
Input Voltage
Current
Power
10-36V DC 90-270V AC, 50/60Hz
1.10A @ 24V DC
2.65A @ 10V DC
26.5W max 32.0W max
Anodized 6013 Aluminum
Titanium (optional)
Sapphire
46.9 mm (1.85 in.)
155 mm (6.09 in)
Al housing: 530 g (1.17lbs)
1
Ti Housing: 710 g (1.56 lbs)
Al housing: 230 g (0.51 lbs) Ti Housing: 400 g (0.88 lbs)
6,000 m (20,000 ft)
-10º C to 40º C (14º F - 104º F)
Day Light White
3
3000 typical
5000K - 6500K*
4
Flood: 85º or Spot: 32º
100-350V DC
0.27A @ 120V AC
0.13A @ 240V AC
Standard Connectors
MCBH3MP
3
2
1 = Hot (DC +) 2 = Neutral (DC -) 3 = Chassis
(High Voltage AC/DC)
1
MCBH5MP
1
5
2
1
2
4
(Low Voltage DC)
1 = DC+ 2 = DC-
2
3 = Chassis 4 = Not Used
3
5= 0-5 V DC Control (0-5V DC Control referenced to Pin 2)
*Other connector options
are available upon request.
Dimensions
Dimming
1 Aluminum Housing, Low Voltage Driver, Flood Reector model. 2 Titanium Housing, Universal Driver, Spot Reector model.
3 Other color options available. 4 Other color temperatures available.
2
0-5V DC AC phase control (TRIAC)
variable voltage (VARIAC)
Page 3
Operator’s Manual
SeaLite
®
Lumos
Table of Contents
Specification Overview 2 Table of Contents 3 Safety Symbols 4
General Notes and Warnings 4 Pre Dive Inspection 4 Post Dive Inspection 4-5 Troubleshooting 5 Flooded Light Repair 5 Limited Warranty 5 RMA Procedure for Repair 5 Appendix A: Dimming Response Curve 6 Appendix B: Driver Efficiency 9 Appendix C: LVDC Step Response Curve 11 Appendix D: Beam Patterns 14
3
Page 4
SeaLite
®
Lumos
Operator’s Manual
Safety Symbol
In this operator’s manual and on the product, safety symbols are used to communicate important safety information. This section is provided to improve understanding of these symbols.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER
! WARNING
CAUTION
NOTICE
This symbol means read the operator’s manual carefully before using the equipment. The operator’s manual contains important information on the safe and proper operation of the equipment.
This symbol means always wear safety glasses with side shields or goggles when handling or using this equipment to reduce the risk of eye injury.
This symbol indicates the risk of electrical shock.
DANGER indicates a hazardous situation which, if not avoided, could result in death or serious injury.
WARNING indicates a hazardous situation which, if not avoided, could result in damage to the product or bodily harm.
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE indicates information that relates to the protection of property.
General Notes and Warnings
You may run your SeaLite® Lumos in air. As the light heats up you will notice that the output will diminish. This is normal, and the light will return to full brightness once it is submerged and allowed to cool down.
DANGER
When the SeaLite® Lumos is operated in air the body may reach temperatures in excess of 65° C. These temperatures may be enough to cause burns if the light is handled without protective clothing.
Do not operate any high voltage electrical equipment in or around water without using a Ground Fault Interrupt circuit (GFI) and an isolation transformer, especially when divers are in the water.
WARNING
Do not clean any part of the light head with any type of alcohol.
There should be no reason to ever open the body of your SeaLite® Lumos light. There are no user serviceable parts inside your new underwater light. Your SeaLite® Lumos was thoroughly pressure tested prior to leaving the factory to confirm the integrity of the complete assembly. Opening the housing may cause potential problems when resealing.
Pre and Post Dive Inspection
Check to make sure that the rear bulkhead connector is secure before deployment.
Check the following areas for previous damage, wear or corrosion: rear bulkhead connector, power cable, front
window.
Rinse your SeaLite® Lumos in fresh water after use in saltwater.
DANGER
After each deployment, carefully check to make sure the light is operational and has not flooded. If it gets flooded, upon surfacing, the light can become internally pressurized, which may be potentially dangerous. Additionally, if the power remains on when the light has partially flooded, it is possible for electrolytic generation of an explosive mixture of hydrogen and oxygen gases. If a light appears flooded upon removal from the water, it should be treated as potentially dangerous. Point the light away from persons and valuable equipment and make sure that the power is disconnected. See the Flooded Light Repair procedure for more information.
4
Page 5
Operator’s Manual
SeaLite
®
Lumos
Troubleshooting
If the light stops working while underwater assume that
it has been flooded. See Flooded Light Repair procedure below.
Once it has been determined that the light is not flooded, or if it does not turn on during pre-deployment checks, check the input power cable/inline connector to make sure that correct voltage is being supplied, and that the correct pinout is being used. See page 2 of this manual for electrical specs and connector pin assignments.
If the light still does not work, return it to DSPL using the RMA Procedure for Repair below.
Flooded Light Repair
If the light stops working while underwater, you should assume that it has been flooded. When working on a potentially flooded light, it is important to use appropriate personal protective equipment to include, at a minimum,
eye and hand protection.
1. Place the light face down on a table making sure that the connector side is facing up.
2. Slowly unscrew the connector/socket assembly to allow any internal pressure to be equalized.
3. Once it is determined that the light is not internally pressurized, it is recommended that the light be returned to DeepSea Power & Light (DSPL) for evaluation and repair using the RMA Procedure.
RMA Procedure for Repair
Should it be necessary to return your light to the factory, follow the procedure for the Flooded Light Repair above, leaving the connector partially unscrewed. For warranty and non-warranty repairs please contact DeepSea Power & Light for a RMA number prior to returning your item. Please have your light model number, serial number and any other pertinent information along with a description of the problem, on hand when you call, or include them in a fax or e-mail. When shipping your item, be sure that the freight is pre-paid (CODs will not be accepted) and that the RMA number is clearly printed on the outside of the box.
Tel: (858) 576-1261 Fax: 858-576-0219 e-mail: RMA@deepsea.com
Limited Warranty
Seller warrants that the goods (except internal electronic components) sold under this contract will be free from defect in material and workmanship for a period of one year from the date of shipment from the factory, if they have been properly used. Internal electronic components are warranted for 90 days from the date of shipment from the factory, if they have been properly used. This warranty will be limited to the repair or replacement of parts and the necessary labor and services required to repair the goods. IT IS EXPRESS LY AGREED THAT THIS WARRANTY WILL BE IN LIEU OF ALL WARRANTIES OF FITNESS AND IN LIEU OF THE WARRANTY OF MERCHANTABILITY. This warranty is the exclusive and only warranty to pass with the goods under this contract. No agent, employee, or representative of the Seller has any authority to bind Seller to any information, representation, or warranty concerning the goods sold under this contract, and unless an affirmation, representation, or warranty made by an agent, employee, or representative is specifically included within this contract, it will not be enforceable by Buyer. If notice of defect is given to DeepSea Power & Light, Inc. within such 90 day or one year warranty period, the sole obligation of DeepSea Power & Light, Inc. shall be to furnish new or repaired parts free of charge in exchange for parts which have been proved defective and does not include any other costs such as the cost of removal of the defective part, installation, labor, or consequential damages of any kind, the exclusive remedy being to require DeepSea Power & Light, Inc. to furnish such new parts. Under no circumstances shall the Buyer be entitled to recover any incidental damages as that term is defined in Commercial Code §2715.
All shipments should be sent to the address below:
DeepSea Power & Light Attn: RMA #### 4033 Ruffin Road San Diego, CA 92123-1817 U.S.A
www.deepsea.com sales@deepsea.com
4033 Rufn Road San Diego, CA 92123-1817 USA
T: (800) 487-3775 F: (858) 576-0219
5
Page 6
SeaLite
®
Lumos
Operator’s Manual
Appendix A
Dimming Response Curves
6
Page 7
Operator’s Manual
SeaLite Lumos 1000 Phase Cut Dimming Response
100%
80%
60%
% Output
40%
20%
SeaLite
®
Lumos
% Output
0%
20° 40° 60° 80° 100° 120° 140° 160° 180°
Input Phase Angle
SLL-1000 120VAC 60Hz SLL-1000 240VAC 50Hz
SeaLite Lumos 1000 Variable Voltage Dimming Response
100%
80%
60%
40%
20%
0%
0V 20V 40V 60V 80V 100V 120V 140V 160V
Input RMS Voltage
SLL-1000 120VAC 60Hz SLL-1000 High Voltage DC
7
Page 8
SeaLite
100%
80%
60%
% Output
40%
20%
®
Lumos
Operator’s Manual
SeaLite Lumos 2000 Analog Dimming Response
0%
0.0V 1.0V 2.0V 3.0V 4.0V 5.0V 6.0V
Dimming Input Voltage
8
Page 9
Operator’s Manual
SeaLite
®
Lumos
Appendix B
Driver Efficiency
9
Page 10
SeaLite
100%
80%
60%
Efficiency
40%
20%
®
Lumos
Operator’s Manual
SeaLite Lumos 1000 Efficiency
0%
60V 110V 160V 210V 260V 310V 360V
Input RMS Voltage
SLL-1000 VAC 60Hz SLL-1000 VAC 50Hz SLL-1000 DC
SeaLite Lumos 2000 Efficiency
100%
80%
60%
Efficiency
40%
3.5
3
2.5
2
1.5
1
Current (A)
20%
0%
6V 12V 18V 24V 30V 36V
10
0.5
0
Input DC Voltage
Efficiency Input Current
Page 11
Operator’s Manual
SeaLite
®
Lumos
Appendix C
Low-Voltage DC Step Response Curve
11
Page 12
SeaLite
®
Lumos
Operator’s Manual
SLL-2000 DIM Input Step Response Characteristics
5V
4V
3V
2V
Control Pulse (V)
1V
0V
-10 0 10 20 30 40 50
Time (ms)
Trigger % Output
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
% Output
12
Page 13
Operator’s Manual
DIM Input Pulse Response: Rise Time SLL-2000 LVDC
SeaLite
®
Lumos
DIM Input Pulse Response: Fall Time SLL-2000 LVDC
13
Page 14
SeaLite
®
Lumos
Operator’s Manual
Appendix D
Beam Patterns
14
Page 15
Operator’s Manual
NOTE: Beam pattern data for a representative sample of the indicated product configuration only.
87
1831
5160
34
1550
2607
SeaLite
®
Lumos
Lux
Radial Lux Intensity Comparison
-90
-85
-80
6000
5000
4000
3000
2000
1000
0
85
90
-75
-70
-65
-60
-55
-50
-45
45
50
55
60
65
70
75
80
-40
40
-35
35
-30
30
-25
25
-20
20
-15
15
-10
10
Angular Distribution
90.0°
80.0°
70.0°
60.0°
50.0°
40.0°
30.0°
20.0°
-5
0
5
10.0°
0.0°
Degrees
-10.0°
-20.0°
-30.0°
-40.0°
-50.0°
-60.0°
-70.0°
-80.0°
-90.0° 0% 25% 50% 75% 100%
% Output
SeaLite Lumos Flood
SLL-2000-DW-F-A05
Lumens: Lumens:
Peak Lux: Peak Lux:
FWHP Angle: FWHP Angle:
SeaLite Lumos Spot
SLL-1000-DW-S-PV
15
Loading...