DeDietrich Vivadens MCR-P 28 BIC PLUS, Vivadens MCR-P 24 User Manual

Page 1
Vivadens
EN
Wall-hung gas condensing boilers
MCR-P 24/28 BIC PLUS
User Guide
127686-04
Page 2
1 Safety ...........................................................................................................4
1.1 General safety instructions .................................4
1.2 Recommendations ................................................5
1.3 Liabilities ...............................................................6
1.3.1 Manufacturer’s liability .............................................6
1.3.2 Installer’s liability .....................................................6
1.3.3 User’s liability ..........................................................7
2 About this manual ......................................................................................8
2.1 Symbols used .......................................................8
2.2 Abbreviations ........................................................8
3 Technical specifications ............................................................................9
3.1 Homologations ......................................................9
3.1.1 Certifications ...........................................................9
3.2 Technical specifications ......................................9
4 Description of the product ......................................................................12
4.1 General description ............................................12
5 Operation ..................................................................................................13
5.1 Control panel .......................................................13
5.2 Commissioning the boiler ..................................14
5.3 Stopping the boiler .............................................14
5.4 Turning on the antifreeze function ....................14
5.5 Changing the settings ........................................15
5.5.1 Changing the heating temperature ........................15
5.5.2 Modifying the comfort setting (ECO) .....................16
5.5.3 Stopping the central heating or activating the Summer
mode .....................................................................17
5.5.4 Changing the domestic hot water
temperature ...........................................................18
5.5.5 Stopping domestic hot water production ...............19
5.5.6 Other settings ........................................................19
1
170915 - 127686-04
Page 3
5.6 Reading out measured values ...........................21
6 Checking and maintenance .....................................................................22
6.1 General instructions ...........................................22
6.2 Periodic checks ..................................................22
6.3 Filling the system ...............................................23
6.4 Bleeding the heating system .............................24
7 Troubleshooting .......................................................................................27
7.1 Error codes ..........................................................27
7.1.1 e01 - e02 - e07 - e09 ......................27
7.1.2 e04 ...................................................................27
7.1.3 Other error codes ..................................................27
7.1.4 Before contacting the installer ...............................28
7.2 Incidents and solutions ......................................29
8 Disposal ....................................................................................................30
8.1 Disposal/Recycling .............................................30
9 Energy savings .........................................................................................31
9.1 Energy savings ...................................................31
9.1.1 Energy-saving advice ............................................31
9.1.2 Room thermostat and settings ..............................31
10 Warranty ....................................................................................................33
10.1 General ................................................................33
10.2 Warranty terms ...................................................33
11 Appendix ...................................................................................................34
11.1 ErP information ...................................................34
11.1.1 Product fiche .........................................................34
11.1.2 Package fiche ........................................................35
Contents
2
170915 - 127686-04
Page 4
3
170915 - 127686-04
Page 5
1 Safety
1.1 General safety instructions
DANGER
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
CAUTION
Only qualified persons are authorised to assemble, install and maintain the installation.
DANGER
If you smell gas:
1. Do not use a naked flame, do not smoke, do not operate electrical contacts or switches ( doorbell, light, motor, lift, etc..).
2. Shut off the gas supply.
3. Open the windows.
4. Evacuate the premises.
5. Call your fitter.
DANGER
If you smell flue gases:
1. Switch the appliance off.
2. Open the windows.
3. Evacuate the premises.
4. Call your fitter.
MCR-P 24/28 BIC PLUS 1. Safety
170915 - 127686-04
4
Page 6
WARNING
Depending on the settings of the appliance:
4 The temperature of the flue gas conduits
may exceed 60°C.
4 The temperature of the radiators may reach
85°C.
4 The temperature of the domestic hot water
may reach 65°C.
CAUTION
Do not neglect to service the appliance: 4 For completely safe and optimum operation,
you must have your boiler regularly serviced by an approved installer.
1.2 Recommendations
WARNING
Only qualified professionals are authorised to work on the appliance and the installation.
4 Regularly check the water pressure in the installation
(minimum pressure 0.8 bar, recommended pressure between 0.8 and 1.5 bar).
4 Keep the appliance accessible at all times. 4 Never remove or cover labels and rating plates affixed
to the appliance. Labels and rating plates must be legible throughout the entire lifetime of the appliance.
4 The appliance should be on Summer or Antrifreeze
mode rather than switched off to guarantee the following functions:
- Anti blocking of pumps
- Antifreeze protection
1. Safety
MCR-P 24/28 BIC PLUS
5
170915 - 127686-04
Page 7
1.3 Liabilities
1.3.1. Manufacturer’s liability
Our products are manufactured in compliance with the requirements of the various applicable European
Directives. They are therefore delivered with [ marking and all relevant documentation.
In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice.
Our liability as the manufacturer may not be invoked in the following cases:
4 Failure to abide by the instructions on using the
appliance.
4 Faulty or insufficient maintenance of the appliance. 4 Failure to abide by the instructions on installing the
appliance.
1.3.2. Installer’s liability
The installer is responsible for the installation and commissioning of the appliance. The installer must respect the following instructions:
4 Read and follow the instructions given in the manuals
provided with the appliance.
4 Carry out installation in compliance with the prevailing
legislation and standards.
4 Perform the initial start up and carry out any checks
necessary.
4 Explain the installation to the user. 4 If a maintenance is necessary, warn the user of the
obligation to check the appliance and maintain it in good working order.
4 Give all the instruction manuals to the user.
MCR-P 24/28 BIC PLUS
1. Safety
170915 - 127686-04
6
Page 8
1.3.3. User’s liability
To guarantee optimum operation of the appliance, the user must respect the following instructions:
4 Read and follow the instructions given in the manuals
provided with the appliance.
4 Call on qualified professionals to carry out installation
and initial start up.
4 Get your installer to explain your installation to you. 4 Ensure the Appliance is serviced in accordance with
the manufacturer’s instructions by a suitable qualified person.
4 Keep the instruction manuals in good condition close
to the appliance.
This appliance is not intended to be used by persons (including children) whose physcial, sensory or mental capacity is impaired or persons with no experience or knowledge, unless they have the benefit, through the intermediary of a person responsible for their safety, of supervision or prior instructions regarding use of the appliance. Care should be taken to ensure that children do not play with the appliance.
If the mains power lead is damaged it must be replaced by the original manufacturer, the manufacturer’s dealer or another competent person to prevent hazardous situations.
1. Safety MCR-P 24/28 BIC PLUS
7
170915 - 127686-04
Page 9
2 About this manual
2.1 Symbols used
In these instructions, various danger levels are employed to draw the user’s attention to particular information. In so doing, we wish to safeguard the user’s safety, highlight hazards and guarantee correct operation of the appliance.
DANGER
Risk of a dangerous situation causing serious physical injury.
WARNING
Risk of a dangerous situation causing slight physical injury.
CAUTION
Risk of material damage.
Signals important information.
¼Signals a referral to other instructions or other pages in the instructions.
2.2 Abbreviations
4 DHW: Domestic hot water.
4 IRC: Interactive remote control.
4 CRC: Communicating remote controller.
4 Hi: Lower heating value LHV (Nett).
4 Hs: Higher heating value HHV (Gross).
MCR-P 24/28 BIC PLUS
2. About this manual
170915 - 127686-04
8
Page 10
3 Technical specifications
3.1 Homologations
3.1.1. Certifications
CE identification no
PIN 0063BQ3009
NOx < 60 mg/kWh
Type of connection Chimney: B
23
Flue gas outlet: C13,C33,C43,C53,C63,C83, C
93
3.2 Technical specifications
Boiler type
MCR-P BIC PLUS
Nominal output (Pn) Heating System (80/60 °C)
minimum-maximum kW 5,5 - 23,8
Factory setting kW 17,8
Nominal output (Pn) Heating System (50/30 °C)
minimum-maximum kW 6,3 - 25,0
Factory setting kW 19,4
Nominal useful output (Pn) DHW minimum-maximum kW 5,5 - 27,4
Factory setting kW 27,4
Gas flow rate at nominal output (15 °C - 1013 mbar ) (max) Natural gas G20
m3/h
2,96
Natural gas G25
m3/h
3,45
Propane (G31)
m3/h
1,15
Heating efficiency under full load (Hi) (80/60 °C) (92/42/EEG) % 99,1
Heating efficiency under full load (Hi) A/R=50/30 °C (EN15502) % 104,4
Heating efficiency under partial load (Hi) (Return temperature 60°C) % 94,3
Heating efficiency under partial load (Hi) ( 92/42/EEG)(Return temperature 30°C) % 110,2
Heating efficiency under full load (Hs) (80/60 °C) (92/42/EEG) % 89,3
Heating efficiency under full load (Hs) (50/30 °C) (EN15502) % 94,0
Heating efficiency under partial load (Hs) (Return temperature 60°C) % 84,9
Heating efficiency under partial load (Hs) ( 92/42/EEG)(Return temperature 30°C) % 99,3
Weight empty, without mounting frame, without front cover kg 67
Heating circuit
Manometric height central heating circuit (ΔT = 20 K)
mbar
(1)
240
Flow temperature °C 75
Maximum temperature (Safety thermostat cut-off) °C 110
Stand-by losses (ΔT = 30 °C) W 86
Water operating pressure PMS max bar (MPa) 3
(1) 1 mbar = 100 Pa, 1 daPa = 1 mmWG (2) Low temperature means for condensing boilers 30°C, for low temperature boilers 37°C and for other heaters 50°C return temperature (at heater inlet) (3) High temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet
3. Technical specifications MCR-P 24/28 BIC PLUS
9
170915 - 127686-04
Page 11
Boiler type MCR-P BIC PLUS
Expansion vessel litres 8
Initial pressure of the expansion vessel bar (MPa) 1
Minimum operating pressure bar (MPa) 0,8
Water content litres 1,8
Domestic hot water circuit
Instruction set outlet temperature °C 60
Nominal max cold water pressure bar (MPa) 8
Minimum pressure for 11 l/min bar (MPa) 0,5
Water capacity litres 40
Combustion products circuit
Connection diameter mm 60/100
Mass flue gas flow rate (min / max) Kg/h 10/47
Flue gas temperature 80/60 °C 95
Pressure available at the flue gas nozzle
Pa
(1)
100
Condensation water pH 50/30
1 - 7
Electricity characteristics
Power supply voltage (50 Hz) V 230
Power consumption W 153
Electrical power circulating pump W 128
Auxiliary electrical power (nominal output, ex heating pump) W 25
Electrical protection index
IPX4D
Technical parameters
Condensing boiler Yes
Low-temperature boiler
(2)
No
B1 boiler No
Cogeneration space heater No
Combination heater Yes
Rated heat output
Prated
kW 24
Useful heat output at rated heat output and high temperature regime
(3)
P4
kW 23,8
Useful heat output at 30% of rated heat output and low temperature regime
(2)
P1
kW 7,9
Seasonal space heating energy efficiency
ƞ
s
%
94
Useful efficiency at rated heat output and high temperature regime
(3)
ƞ
4
% 89,3
Useful efficiency at 30% of rated heat output and low temperature regime
(2)
ƞ
1
% 99,3
Auxiliary electricity consumption
Full load
elmax
kW 0,025
Partial load
elmin
kW 0,025
Standby mode
P
SB
kW 0,003
Other items
Standby heat loss
P
stby
kW 0,057
Ignition burner power consumption
P
ign
kW -
Annual energy consumption
Q
HE
kWh GJ
73
Sound power level, indoors
L
WA
dB 47
Emissions of nitrogen oxides
NO
x
mg/kWh 59
Domestic hot water parameters
(1) 1 mbar = 100 Pa, 1 daPa = 1 mmWG (2) Low temperature means for condensing boilers 30°C, for low temperature boilers 37°C and for other heaters 50°C return temperature (at heater inlet) (3) High temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet
MCR-P 24/28 BIC PLUS 3. Technical specifications
170915 - 127686-04
10
Page 12
Boiler type MCR-P BIC PLUS
Declared load profile XXL
Daily electricity consumption
Q
elec
kWh 0,231
Annual energy consumption
AEC
kWh 51
Water heating energy efficiency
ƞ
wh
% 74
Daily fuel consumption
Q
fuel
kWh 32,373
Annual fuel consumption
AFC
GJ 26
(1) 1 mbar = 100 Pa, 1 daPa = 1 mmWG (2) Low temperature means for condensing boilers 30°C, for low temperature boilers 37°C and for other heaters 50°C return temperature (at heater inlet) (3) High temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet
See the back cover for contact details.
3. Technical specifications MCR-P 24/28 BIC PLUS
11
170915 - 127686-04
Page 13
4 Description of the product
4.1 General description
Wall-hung gas condensing boilers
4 Heating and domestic hot water production with integrated DHW
tank.
4 High efficiency heating.
4 Low pollutant emissions.
4 Flue gas discharge via a forced flue, chimney, bi-flow or 3CE type
connection.
MCR-P 24/28 BIC PLUS 4. Description of the product
170915 - 127686-04
12
Page 14
5 Operation
5.1 Control panel
A
Menu key
B
Display
C
Main ON/OFF switch
D
Pressure gauge
E
Sweep key
F
( or RESET key
G
Heating temperature key or -
H
DHW temperature key or +
J
SERVICE or U key
The display indicates the state of the boiler and any errors. The symbols located above the function keys indicate their current function.
Pressing on any key will display the current status of the boiler and the current command code. If there is a fault, the corresponding code continues to be displayed.
5. Operation
MCR-P 24/28 BIC PLUS
13
170915 - 127686-04
Page 15
5.2 Commissioning the boiler
1. Check the water pressure in the installation.
2. Open the gas valve.
3. Throw the boiler’s ON / OFF switch.
4. The start-up cycle begins. It lasts 2 minutes and cannot be interrupted. During the start-up cycle, the display shows the following information:
fK[xx
: Software version
pK[xx
: Parameter version
The version numbers are displayed alternately.
5. When the start-up cycle is finished, the display shows 0. The
boiler is now operational.
5.3 Stopping the boiler
1. Throw the boiler’s ON / OFF switch.
2. Switch off the boiler electrical power supply.
3. Close the gas valve.
4. Ensure that the boiler and system are protected against frost damage.
5.4 Turning on the antifreeze function
We recommend setting the boiler thermostat to a value off 10°C if using a classic installation.
Set the boiler to ECO mode using parameter p4, this action will switch off the standby setting.
Installation and room antifreeze protection is guaranteed if you are absent.
A000785-A
A000787-A
A000786-A
MCR-P 24/28 BIC PLUS
5. Operation
170915 - 127686-04
14
Page 16
If the temperature of the central heating water in the boiler falls too much, the integrated protection device switches itself on:
4 If the water temperature is lower than 7°C, the circulating pump is
activated.
4 If the water temperature is lower than 3°C, the boiler is activated.
4 When the water temperature is above 10 °C, the boiler is switched
off and the circulation pump runs for another 15 minutes.
CAUTION
This function is a protection device for the boiler only, not for the system or buiding fabric.
CAUTION
If a room thermostat, connected via connectors 7 and 8, is activated, the boiler will operate permanently until it reaches the flow setting point.
5.5 Changing the settings
5.5.1. Changing the heating temperature
If an outside temperature sensor or an OpenTherm control system is fitted, the heating flow temperature is adjusted automatically.
In summer, it is possible to reduce the heating flow temperature whilst maintaining comfort. To do this, proceed as follows:
1. Press the D key. The symbol D and the current temperature are displayed.
2. Use the [+] and [-] keys to change the parameter value.
3. To confirm the new value, press the key S.
It also possible to modify this setting using the parameter
p1. ¼
See chapter: "Other settings", page 19.
T000147-A
GA,
HF,
5. Operation MCR-P 24/28 BIC PLUS
15
170915 - 127686-04
Page 17
5.5.2. Modifying the comfort setting (ECO)
The user can consult or modify the following 3 settings:
4 ON = Activation of the energy-saving setting.
4 OFF = Activation of the comfort setting.
4 AUTO = Setting dependent on the control unit (Factory setting).
1. Press the f key 1 times. The symbol Q flashes.
2. Press the f key a second time. The symbol ECO flashes.
3. To confirm, press the S key.
4. The current operating status is shown on the display:AUTO.
5. Use the + and - keys to change the parameter value.
6. To confirm, press the S key.
7. Press the
>
key 2 times to return to the current operating
mode.
It also possible to modify this setting using the parameter p4.
Ajj
2x
T000148-B
MCR-P 24/28 BIC PLUS 5. Operation
170915 - 127686-04
16
Page 18
5.5.3. Stopping the central heating or activating
the Summer mode
1. Press the D key. The symbol D and the current temperature are displayed.
2. Press the key [-] several times until the value
0ff
is displayed.
3. To confirm the new value, press the key S. The symbol C appears.
4 It also possible to modify this setting using the
parameter p3. ¼See chapter: "Other settings", page 19.
4 Domestic hot water production is maintained.
HF,
Ajj
T000141-A
5. Operation MCR-P 24/28 BIC PLUS
17
170915 - 127686-04
Page 19
5.5.4. Changing the domestic hot water
temperature
1. Press the N key. The symbol N and the current temperature are displayed.
2. Use the [+] and [-] keys to change the parameter value.
3. To confirm the new value, press the key S.
It also possible to modify this setting using the parameter
p2
.
T000143-A
MCR-P 24/28 BIC PLUS 5. Operation
170915 - 127686-04
18
Page 20
5.5.5. Stopping domestic hot water production
1. Press the N key. The symbol N and the current temperature are displayed.
2. Press the key [-] several times until the value
0ff
is displayed.
3. To confirm the new value, press the key S. The symbol T appears.
It also possible to modify this setting using the parameter p3. ¼See chapter: "Other settings", page 19.
5.5.6. Other settings
Parameter
Description Adjustment range Factory setting
p1
Flow temperature 20 to 85 °C 75 °C
p2
Domestic hot water temperature 40 to 65 °C 60 °C
p3
Heating / DHW mode
0 = Heating deactivated (C) / DHW deactivated (T)
1
1 = Heating activated (D) / DHW activated (N) 2 = Heating activated (D) / DHW deactivated (T) 3 = Heating deactivated (C) / DHW activated (N)
p4
ECO mode
0 = Comfort mode
01 = Energy-saving mode
2 = Management using a programmable thermostat
p5
Anticipation resistance
0 = No anticipation resistance for the ON/OFF thermostat
0
1 = Anticipation resistance for the ON/OFF thermostat
p6
Display screen
0 = The screen stays off
2
1 = The screen stays on
2 = The screen switches off automatically after 3 minutes
GA,
Ajj
T000142-A
5. Operation MCR-P 24/28 BIC PLUS
19
170915 - 127686-04
Page 21
To change these parameters, proceed as follows:
1. Press key f several times until the symbol W flashes on the menu bar.
2. Press the S key to enter the "User" menu. The symbol
p[1
appears.
3. Use the + and - keys to select to parameter to be changed.
4. Press the S key to display the parameter value selected.
5. Use the + and - keys to change the parameter value.
6. To confirm the new value, press the key S. The name of the modified parameter is displayed.
7. If necessary, set other parameters by selecting them using the + or - keys.
8. To exit the User menu, press the
>
key 2 times.
If no selections are made in the various modes for 10 minutes, the boiler resumes the settings prior to manipulation.
2x
3x
T000307-A
MCR-P 24/28 BIC PLUS 5. Operation
170915 - 127686-04
20
Page 22
5.6 Reading out measured values
The following values can be displayed in the information menu Q:
4 t1 = Flow temperature (°C) 4 t2 = Return temperature (°C) 4 t3 = DHW sensor temperature (°C)
This temperature is used only for internal management in DHW mode. During DHW draw-off, this value does not correspond to the actual DHW outlet temperature (it is always lower).
4 t4 = Outside temperature (°C) 4 fl = Ionization current (μA) 4 Mf = Fan speed (rpm)
1. Press the f key. The symbol Q flashes.
2. To access the parameters, press key S.
3. Press the [+] key successively to scroll down the various parameters.
4. Press the
>
key 2 times to return to the current operating mode
T000138-A
5. Operation MCR-P 24/28 BIC PLUS
21
170915 - 127686-04
Page 23
6 Checking and maintenance
6.1 General instructions
CAUTION
4 An annual inspection is compulsory.
4 We recommend taking out a maintenance contract.
4 Maintenance operations must be done by a qualified
engineer.
4 Only original spare parts must be used.
4 Make certain that the flues and chimneys are
connected, in good condition and not blocked.
4 Do not modify nor block the condensate outlet(s).
4 If a neutralisation system is installed, follow the
instructions delivered with the neutralisation system for cleaning and servicing of this system.
6.2 Periodic checks
4 Check the water pressure in the installation. If the water pressure
is too low, add more water to the installation. ¼See chapter: "Filling the system", page 23.
4 Carry out a visual check for the presence of any water leaks.
4 Open and close the radiator valves several times a year (this
prevents the valves from seizing up).
1
2
3
4
T000181-B
MCR-P 24/28 BIC PLUS 6. Checking and maintenance
170915 - 127686-04
22
Page 24
4 Clean the outside of the boiler using a damp cloth and a light
detergent.
CAUTION
Only a qualified professional is authorised to clean the inside of the boiler.
6.3 Filling the system
The water pressure in the boiler must be between 1,5 and 2 bar. Add water to the installation if necessary. To do this, proceed as follows:
1. Open the valves on all radiators connected to the heating system.
2. Set the room thermostat to as low a temperature as possible.
3. Switch off the boiler electrical power supply.
1
2
3
4
T000181-B
T000182-A
T000155-A
6. Checking and maintenance
MCR-P 24/28 BIC PLUS
23
170915 - 127686-04
Page 25
4. Wait until the temperature drops below 40°C and the radiators seem cold before filling the central heating system.
5. Open the valve.
6. Close the valve.
7. After filling the installation, switch the boiler on.
8. Set the room thermostat or the regulator.
9. Set the radiator valves.
CAUTION
Filling and bleeding the installation 2 times a year should be sufficient to obtain an adequate hydraulic pressure. If it is often necessary to top up the installation with water, contact your fitter.
6.4 Bleeding the heating system
It is essential that you bleed any air in the calorifier, the conduits or the taps to prevent the annoying noises likely to be produced during heating or when tapping water. To do this, proceed as follows:
1. Open the valves on all radiators connected to the heating system.
2. Set the room thermostat as high as possible.
3. Wait until the radiators are hot.
T000185-A
T000847-A
1
2
3
4
T000181-B
T000183-A
T000184-A
MCR-P 24/28 BIC PLUS
6. Checking and maintenance
170915 - 127686-04
24
Page 26
4. Switch the boiler off.
5. Wait around 10 minutes until the radiators are cold.
6. Bleed the radiators. Start with the lower floors.
7. Open the bleed connection using the bleed key provided whilst keeping a rag pressed against the connection.
T000155-A
T000185-A
T000216-A
3
1
4
5
2
T000217-A
6. Checking and maintenance MCR-P 24/28 BIC PLUS
25
170915 - 127686-04
Page 27
8. Wait until water comes out of the bleed valve and then close the bleed connection.
CAUTION
The water may still be hot.
9. After venting, check whether the pressure in the installation is still sufficient. Add water to the installation if necessary.
10.Switch on the boiler. A vent cycle of a duration of around 3 minutes is carried out automatically.
11.Set the room thermostat or the regulator.
T000218-A
T000228-A
1,5 ... 2 bar
T000183-A
MCR-P 24/28 BIC PLUS 6. Checking and maintenance
170915 - 127686-04
26
Page 28
7 Troubleshooting
7.1 Error codes
7.1.1. e01 - e02 - e07 - e09
If one of the breakdown codes opposite is dispayed, check the hydraulic pressure:
Case 1: Pressure higher than or equal to 1 bar
4 Press the RESET key to reset the appliance. Wait a few seconds.
- If the display shows 0, the boiler is again operating normally.
- If the display again shows e1, e2 or e7, contact the
installer.
Case 2: Pressure lower than 1 bar
4 Top up the installation with water. ¼See chapter: "Filling the
system", page 23.
4 Press the RESET key to reset the appliance. Wait a few seconds.
- If the display shows 0, the boiler is again operating normally.
- If the display again shows e1, e2, e7 or e9, contact the
installer.
7.1.2.
e04
If the breakdown code opposite is shown:
4 Check the position of the gas valve. Open the gas valve if it is
closed.
4 Press the RESET key to reset the appliance. Wait a few seconds.
- If the display shows 0, the boiler is again operating normally.
- If the display again shows e4, contact the installer.
7.1.3. Other error codes
If another error code is displayed, contact the installer.
T004115-A
A000781-A
A000782-A
7. Troubleshooting
MCR-P 24/28 BIC PLUS
27
170915 - 127686-04
Page 29
7.1.4. Before contacting the installer
Before contacting the installer
Note the following information on the appliance’s rating plate:
4 Type of gas used
4 Boiler type
4 Manufacturing date
4 Serial no. of the appliance
AD-0000686-01
MCR-P 24/28 BIC PLUS 7. Troubleshooting
170915 - 127686-04
28
Page 30
7.2 Incidents and solutions
Problem Probable causes Solution
There is no domestic hot water.
The boiler is not switched on.
4 Check that the boiler is switched on.
4 Check the fuses and switches.
4 Check that the gas valve is fully opened.
The DHW mode is deactivated. Activate the DHW mode.
The water pressure is too low (< 1 bar).
Top up the installation with water. ¼See chapter: "Filling the system", page 23.
The energy-saving shower head is restricting the water flow.
Clean the shower head; replace if necessary.
The radiators are cold.
The heating temperature setting is too low.
Increase the value of parameter p1 or, if a room thermostat is connected, increase the temperature.
The heating mode is deactivated. Activate the heating mode.
The radiator valves are closed. Open the valves on all radiators connected to the
heating system.
The boiler is not switched on.
4 Check that the boiler is switched on.
4 Check the fuses and switches.
4 Check that the gas valve is fully opened.
The water pressure is too low (< 1 bar).
Top up the installation with water. ¼See chapter: "Filling the system", page 23.
The boiler is not working.
The heating temperature setting is too low.
The boiler is not switched on.
4 Check that the boiler is switched on.
4 Check the fuses and switches.
4 Check that the gas valve is fully opened.
The water pressure is too low (< 1 bar).
Top up the installation with water. ¼See chapter: "Filling the system", page 23.
An error code appears on the display.
4 Press the Reset button for 2 seconds. 4 Correct the error if possible. ¼See chapter:
"Error codes", page 27.
The gas pressure is too low. Open the gas valve.
The water pressure is too low (< 1 bar).
Not enough water in the installation.
Top up the installation with water. ¼See chapter: "Filling the system", page 23.
Water leak. Contact the fitter.
Significant variations in domestic hot water temperature.
Insufficient water supply. Open the valve.
Clicking in the central heating pipes
The central heating pipe connections are too tight.
Contact the fitter.
There is air in the heating pipes. It is essential that you bleed any air in the calorifier, the
conduits or the taps to prevent the annoying noises likely to be produced during heating or when tapping water.
The water is circulating too quickly in the central heating system.
Contact the fitter.
Significant water leak under or close to the boiler
The boiler or central heating pipes are damaged.
Close the water supply. Contact the fitter.
7. Troubleshooting MCR-P 24/28 BIC PLUS
29
170915 - 127686-04
Page 31
8 Disposal
8.1 Disposal/Recycling
Removal and disposal of the boiler must be carried out by a qualified professional in compliance with prevailing local and national regulations.
Follow the steps below to remove the boiler:
4 Switch off the boiler electrical power supply.
4 Shut off the gas supply.
4 Close the water supply.
4 Vent the heating installation.
4 Remove the siphon.
4 Remove the air and exhaust pipes.
4 Disconnect all pipes from the boiler.
4 Remove the boiler.
MCR-P 24/28 BIC PLUS 8. Disposal
170915 - 127686-04
30
Page 32
9 Energy savings
9.1 Energy savings
This chapter contains:
4 Energy-saving advice
4 Advice on setting the room thermostat correctly
9.1.1. Energy-saving advice
4 Keep the room in which the boiler is installed well ventilated. Do
not block ventilation outlets. Install reflective panels behind the radiators to prevent heat losses.
4 Do not cover the radiators. Do not hang curtains in front of the
radiators.
4 Insulate the pipes in rooms that are not heated (cellars and lofts).
4 Close the radiators in rooms not in use.
4 Do not run hot (or cold) water pointlessly.
4 Install a water-saving shower head to save up to 40 % energy.
4 Take showers rather than baths. A bath consumes twice as much
water and energy.
9.1.2. Room thermostat and settings
The room thermostat is available in the following versions:
4 2-wire ON/OFF thermostat
4 Modulating thermostat
4 Programmable room temperature thermostat
The type of thermostat and its settings have a considerable influence on energy consumption.
A few tips:
4 A modulating thermostat, possibly in combination with
thermostatic valve radiators, saves energy and offers considerable comfort. This combination allows you to set the temperature on each flow.
4 Completely closing and opening thermostatic valve radiators
causes undesirable temperature fluctuations. Open and close thermostatic valves in small steps.
4 Lower the thermostat to around 20°C. This reduces heating costs
and energy consumption.
4 Lower the room thermostat when you air the rooms.
9. Energy savings
MCR-P 24/28 BIC PLUS
31
170915 - 127686-04
Page 33
4 If you are using an ON/OFF type thermostat, reduce the water
temperature value (p1) in summer (e.g. 60 in summer and 80 in winter).
4 When setting an hourly programmable thermostat, keep in mind
the days you are absent or on vacation.
MCR-P 24/28 BIC PLUS 9. Energy savings
170915 - 127686-04
32
Page 34
10 Warranty
10.1 General
You have just purchased one of our appliances and we thank you for the trust you have placed in our products.
Please note that your appliance will provide good service for a longer period of time if it is regularly checked and maintained.
Your installer and our customer support network are at your disposal at all times.
10.2 Warranty terms
The following provisions are not exclusive of the buyer being able benefit from the legal provisions applicable regarding hidden defects in the buyer’s country.
Starting from the purchase date shown on the original installer’s invoice, your appliance has a contractual guarantee against any manufacturing defect.
The length of the guarantee is mentioned in the price catalogue. The manufacturer is not liable for any improper use of the appliance or failure to maintain or install the unit correctly (the user shall take care to ensure that the system is installed by a qualified engineer).
In particular, the manufacturer shall not be held responsible for any damage, loss or injury caused by installations which do not comply with the following:
4 applicable local laws and regulations,
4 specific requirements relating to the installation, such as national
and/or local regulations,
4 the manufacturer’s instructions, in particular those relating to the
regular maintenance of the unit,
4 the rules of the profession.
The warranty is limited to the exchange or repair of such parts as have been recognised to be faulty by our technical department and does not cover labour, travel and carriage costs.
The warranty shall not apply to the replacement or repair of parts damaged by normal wear and tear, negligence, repairs by unqualified parties, faulty or insufficient monitoring and maintenance, faulty power supply or the use of unsuitable fuel.
Sub-assemblies such as motors, pumps, electric valves etc. are guaranteed only if they have never been dismantled.
The legislation laid down by european directive 99/44/EEC, transposed by legislative decree No. 24 of 2 February 2002 published in O.J. No. 57 of 8 March 2002, continues to apply.
10. Warranty
MCR-P 24/28 BIC PLUS
33
170915 - 127686-04
Page 35
11 Appendix
11.1 ErP information
11.1.1. Product fiche
DeDietrich - MCR - P BIC PLUS
24/28
Space heating - Temperature application
Medium
Water heating - Declared load profile
XXL
Seasonal space heating energy efficiency class
A
Water heating energy efficiency class
B
Rated heat output (Prated of Psup) kW 24
Space heating - Annual energy consumption GJ 73
Water heating - Annual energy consumption kWhGJ51
26
Seasonal space heating energy efficiency % 94
Water heating energy efficiency % 74
Sound power level LWA indoors dB
47
For specific precautions about assembling, installing and maintaining:
¼ "General safety instructions", page 4
MCR-P 24/28 BIC PLUS 11. Appendix
170915 - 127686-04
34
Page 36
11.1.2. Package fiche
Package card for boilers stating the energy efficiency for central heating for the package
AD-3000743-01
%
1
‘I’
2
%+
3
%( - ‘I’ ) x 0.1 = ±
4
%(‘III’ x + ‘IV’ x ) x 0.9 x ( /100) x = +
(1)
A* = 0.95, A = 0.91, B = 0.86, C = 0.83, D - G = 0.81
5
%( - ‘I’ ) x ‘II’ = +
6
%0.5 x 0.5 x = -
54
<30%
G F E D C B A A
+
A
++
A
+++
%+ (50 x ‘II’) =
7
7
%
from fi che of solar device
Solar contribution AND Supplementary heat pump
Solar contribution
The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed in a building, as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the products in relation to building size and characteristics.
Boiler and supplementary heat pump installed with low temperature heat emitters at 35°C ?
Seasonal space heating energy effi ciency class of package
Seasonal space heating energy effi ciency of package
OR
Seasonal space heating energy effi ciency (in %)
Supplementary heat pump
Tank rating
Collector effi ciency (in %)
Tank volume (in m³) Collector size (in m²)
Seasonal space heating energy effi ciency (in %)
Supplementary boiler
Class I = 1%, Class II = 2%, Class III = 1.5%, Class IV = 2%, Class V = 3%, Class VI = 4%, Class VII = 3.5%, Class VIII = 5%
Temperature control
Seasonal space heating energy effi ciency of boiler
(1) If tank rating is above A, use 0.95
select smaller value
from fi che of heat pump
from fi che of heat pump
from fi che of boiler
from fi che of temperature control
11. Appendix MCR-P 24/28 BIC PLUS
35
170915 - 127686-04
Page 37
I
The value of the seasonal space heating energy efficiency of the preferential space heater, expressed in %.
II
The factor for weighting the heat output of preferential and supplementary heaters of a package as set out in the following table.
III
The value of the mathematical expression:294/(11 . Prated), whereby (Prated) is related to the preferential space heater.
IV
The value of the mathematical expression:115/(11 . Prated), whereby (Prated) is related to the preferential space heater.
Psup / (Prated + Psup)
(1)(2)
II, package without hot water storage tank II, package with hot water storage tank
0 0 0
0,1 0,3 0,37
0,2 0,55 0,70
0,3 0,75 0,85
0,4 0,85 0,94
0,5 0,95 0,98
0,6 0,98 1,00
≥ 0,7 1,00 1,00
(1) The intermediate values are calculated by linear interpolation between the two adjacent values (2) Prated is related to the preferential space heater or combination heater
MCR-P 24/28 BIC PLUS 11. Appendix
170915 - 127686-04
36
Page 38
Package card for combination heating appliances (boilers or heat pumps) stating the energy efficiency for water heating for the package
AD-3000747-01
%
1
‘I’
2
%(1.1 x ‘I’ - 10%) x ‘II’ - - ‘I’ = +
‘III’
<28%
XXL
XL
L
M
G F E D C B A A
+
A
++
A
+++
3
%
%+ 0.4 x =
23
%- 0.2 x =
23
The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed in a building, as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the products in relation to building size and characteristics.
Water heating energy effi ciency class of package under average climate
Water heating energy effi ciency of package under average climate
Auxiliary electricity
Solar contribution
Water heating energy effi ciency of combination heater
from fi che of solar device
Colder:
Warmer:
Water heating energy effi ciency under colder and warmer climate conditions
Declared load profi le:
I
The value of the water heating energy efficiency of the combination heater, expressed in %.
II
.The value of the mathematical expression (220 * Q
ref
)/
Q
nonsol
, where Q
ref
is taken from Regulation EU
811/2013, Annex VII Table 15 and Q
nonsol
from the
product fiche of the solar device for the declared load profile M, L, XL or XXL of the combination heater.
11. Appendix MCR-P 24/28 BIC PLUS
37
170915 - 127686-04
Page 39
III
The value of the mathematical expression (Q
aux
. 2,5)/
(220 . Q
ref
), expressed in %, where Q
aux
is taken from the
product fiche of the solar device and Q
ref
from Regulation
EU 811/2013, Annex VII Table 15 for the declared load profile M, L, XL or XXL.
MCR-P 24/28 BIC PLUS 11. Appendix
170915 - 127686-04
38
Page 40
11. Appendix MCR-P 24/28 BIC PLUS
39
170915 - 127686-04
Page 41
MCR-P 24/28 BIC PLUS 11. Appendix
170915 - 127686-04
40
Page 42
Page 43
Page 44
AD001NU-A,
DUEDI S.r.l.
DE DIETRICH SERVICE
BDR Thermea (Czech republic) s.r.o
www.duediclima.it
www.dedietrich.cz
Distributore Ufficiale Esclusivo
De Dietrich-Thermique Italia
www.dedietrich-heiztechnik.com
Freecall 0800 / 201608
Jeseniova 2770/56
130 00 Praha 3
+49 (0)25 72 / 9161-0
+49 (0)25 72 / 9161-102
info@remeha.de
Via Passatore, 12 - 12010 San Defendente di Cervasca CUNEO
+39 0171 857170 +39 0171 687875 info@duediclima.it
+420 271 001 627 info@dedietrich.cz
IT
DE DIETRICH THERMIQUE Iberia S.L.U.
www.dedietrich-calefaccion.es
C/Salvador Espriu, 11
08908 L’HOSPITALET de LLOBREGAT
+34 935 475 850 info@dedietrich-calefaccion.es
ES
129164, Россия, г. Москва
Зубарев переулок, д. 15/1
Бизнес-центр «Чайка Плаза»,
офис 309
+7 (495) 221-31-51
CZ
DE DIETRICH THERMIQUE S.A.S
info@dedietrich.ru
© Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing.
170915
127686