DeDietrich SUN 211 Installation, User And Service Manual

EN
Flat solar panels
NEO 2.1 / SUN 211
Installation, User and Service Manual
Roof-Surface Installation Terrace mounting
300020210-001-B
Contents
1 Introduction ................................................................................................4
1.1 Used symbols .......................................................4
1.2 General ..................................................................4
1.2.1 Manufacturer's liability .............................................4
1.2.2 Installer's liability .....................................................5
2 Safety instructions and recommendations ..............................................6
2.1 Safety instructions ...............................................6
2.2 Recommendations ................................................6
3 Description ..................................................................................................8
3.1 Operating principle ...............................................8
3.2 Technical characteristics .....................................8
4 Installation ..................................................................................................9
4.1 Regulations governing installation .....................9
4.1.1 All installation system ..............................................9
4.1.2 Roof-Surface Installation .........................................9
4.1.3 Terrace mounting ..................................................10
4.2 Package list .........................................................11
4.2.1 Package for an assembly on the roof ....................11
4.2.2 Anchorage fittings for roof mounting .....................12
4.2.3 Terrace assembly kit .............................................13
4.3 Main dimensions .................................................14
4.4 Installation diagrams ..........................................15
4.5 Assembling the solar collectors .......................17
4.5.1 Warning .................................................................17
4.5.2 Tools required .......................................................18
4.5.3 Dimensions ...........................................................18
4.5.4 Fitting the hooks ....................................................20
4.5.5 Vertical assembly, juxtaposed ...............................23
4.5.6 Horizontal assembly, superposed (only on
roof) .......................................................................29
1
05/10/09 - 300020210-001-B
4.6 Solar collector temperature sensor ..................35
4.7 Passing Pipes and Cable through the
Roof ......................................................................36
4.8 Hydraulic connections .......................................37
4.8.1 Connection dimensions .........................................37
4.8.2 Connecting ............................................................37
4.8.3 Pipe insulation .......................................................38
4.9 Filling the system ...............................................38
5 Commissioning ........................................................................................40
5.1 Check points before commissioning ................40
5.2 Commissioning ...................................................40
6 Checking and maintenance .....................................................................41
6.1 General instructions ...........................................41
7 Warranty ....................................................................................................42
7.1 General ................................................................42
7.2 Warranty terms ...................................................42
Contents NEO 2.1 / SUN 211
2
05/10/09 - 300020210-001-B
3
05/10/09 - 300020210-001-B
1 Introduction
1.1 Used symbols
In these instructions, various danger levels are employed to draw the user's attention to particular information. In so doing, we wish to safeguard the user's safety, obviate hazards and guarantee correct operation of the appliance.
DANGER
Risk of a dangerous situation causing serious physical injury.
WARNING
Risk of a dangerous situation causing slight physical injury.
CAUTION
Risk of material damage.
Signals important information.
¼ Signals a referral to other instructions or other pages in the instructions.
Caution: Risk of being burnt.
Zone susceptible to snow.
Zone susceptible to windy conditions.
1.2 General
1.2.1. Manufacturer's liability
Our products are manufactured in compliance with the essential requirements of the various Directives applicable. They are therefore
delivered with [ marking and all relevant documentation.
NEO 2.1 / SUN 211
1. Introduction
05/10/09 - 300020210-001-B
4
In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice.
Our liability as the manufacturer may not be invoked in the following cases:
4 Incorrect use of the appliance.
4 Faulty or insufficient maintenance of the appliance.
4 Incorrect installation of the appliance.
1.2.2. Installer's liability
The installer is responsible for the installation and inital start up of the appliance. The installer must respect the following instructions:
4 Read and follow the instructions given in the manuals provided
with the appliance.
4 Carry out installation in compliance with the prevailing legislation
and standards.
4 Perform the initial start up and carry out any checks necessary.
4 Explain the installation to the user.
4 Warn the user of the obligation to check the appliance and
maintain it in good working order.
4 Give all the instruction manuals to the user.
1. Introduction NEO 2.1 / SUN 211
5
05/10/09 - 300020210-001-B
2 Safety instructions and
recommendations
2.1 Safety instructions
DANGER
The permissible roof load of the building must not at any time be exceeded. If necessary, a structural engineer should be consulted before commencing work.
WARNING
All electrical work must be carried out by a qualified electrician and must conform to the applicable standards, specifications, safety regulations and the requirements of the local electricity supplier.
CAUTION
Do not neglect to service the appliance. Contact a qualified professional or take out a maintenance contract for the annual servicing of the appliance.
2.2 Recommendations
WARNING
4 Any operation on the installation must be performed
by a qualified technician respecting professional regulations and in accordance with this document.
4 When making the connections, it is imperative that
the standards and corresponding local directives are respected.
4 The flat solar panels and fittings should be handled carefully during
transportation and storage. If the packing has nevertheless been damaged during transit, the damage must be reported immediately to and claimed against the carrier.
4 The contents of the assembly kit must be checked before
installation against the list which accompnaies each kit.
4 When installing the panels, take note of the safety instructions in
this document.
4 The packing material should be properly disposed of after
installation.
4 Insulate the pipes in rooms that are not heated (cellars and lofts).
4 Check regularly that the installation contains water and is
pressurised.
NEO 2.1 / SUN 211
2. Safety instructions and recommendations
05/10/09 - 300020210-001-B
6
4 Service the appliance regularly to ensure that it operates correctly.
2. Safety instructions and recommendations NEO 2.1 / SUN 211
7
05/10/09 - 300020210-001-B
3 Description
3.1 Operating principle
The short-wave solar radiation (sunlight) striking the solar panel is converted into heat by the selective coating on the absorber. From there it is transferred by heat conduction to the absorber pipe and carried by the heat-transporting fluid to the calorifier. The solar-panel fluid heats the calorifier by means of the energy absorbed from the sun and cools down itself in the process.. The cooled heat­transporting fluid then flows back to the solar panel in order to collect more solar energy. An intelligent control system ensures that the circulation system is only active when there is sufficient solar radiation, thus optimising the collection of solar energy.
3.2 Technical characteristics
Length mm 1960
Width mm 1060
Height mm 70
Weight kg 34.45
Gross collector area A
G
m
2
2,1
Inlet surface Aa
m
2
1,88
Absorber surface A
A
m
2
1,90
Water content litres 1,2
Maximum operating pressure bar 10
Testing pressure bar 15
Optical efficiency η
o
0,773
Loss rating a
1
W/m2.K
3,676
Loss rating a
2
W/m2.K
0,0143
Stagnation temperature °C 180
Hydraulic connections mm 12
Pressure drop mbar See below
Fitted tilt angle minimum/maximum
° 20 to 65
Load loss curve
A
Pressure drop (mbar)
Z
Mass flow (Kg/h)
0
50
100
150
200
250
300
350
400
0 50 100 150 200 250 300
1
2
M002031-A
NEO 2.1 / SUN 211 3. Description
05/10/09 - 300020210-001-B
8
4 Installation
4.1 Regulations governing installation
4.1.1. All installation system
CAUTION
4 The installation and maintenance of the appliance
must be carried out by a qualified professional in compliance with the statutory texts of the codes of conduct in force.
4 Solar installations must be earthed to protect them
against lightning.
4 Protection of the environment: Place a container of
sufficient volume under the drain pipe and the valve discharge pipe.
4 The installation should therefore not be flushed or filled when the
collectors are hot (in strong sunshine).
4 The solar system must at all times be filled with : heat transporting
fluidTyfocor L or LS.
4.1.2. Roof-Surface Installation
CAUTION
Before installation, make sure that the framework is solid and strong enough to comply with the static requirements.
4 The roof-integral installation set is designed specifically as a
mounting system for the NEO 2.1 / SUN 211 flat solar panels and may only be used in accordance with their building regulations approval.
M001788-A
M001707-A
4. Installation
NEO 2.1 / SUN 211
9
05/10/09 - 300020210-001-B
4 The installation set is designed for rooves with standard roof
tiles. If the roof in which the panels are to be fitted has particularly high roof tiles, please consult your specialist advisor.
4.1.3. Terrace mounting
n
Ballast per solar panel (kg)
Rules NV65 (DTU P06-002, April 2000): Calculation rules defining the effects of snow and wind on buildings.
CAUTION
If the assembly's supporting frame is not screwed to the building, it must be weighted down according to the technical guidance. Kerb stones (100 x 250 x 080), for example, are suitable for weighting down. Stones must be slid in and set in between the T frames. Position the ballast stones before the finally attaching the inner screws and the cross. At no time should the maximum authorised load be exceeded. If necessary, a structural engineer should be consulted before commencing work.
Building height (m) Ballast per solar panel (kg)
Zone 1 Zone 2 Zone 3 Zone 4 Zone 5
< 10 140 170 210 255 340
10 to 20 170 200 250 300 405
20 to 30 190 230 285 340 455
30 to 40 205 245 310 370 495
Increase coefficient for exposed sites (shoreline, hilltops, narrow valleys, etc.)
1.35 1.3 1.25 1.2 1.2
The values indicated in the "Zone 5" column in the table are valid for the Outre-Mer regions.
n
Pull-out resistance of the screws holding the supports in place
Building height (m)
Panel holding resistance in terms of panel slope
(N/m2)
60° 45°
< 10 4400 3400
10 to 20 5200 4300
20 to 30 5900 4800
30 to 40 6400 5200
1
2
3
4
M001772-A
NEO 2.1 / SUN 211 4. Installation
05/10/09 - 300020210-001-B
10
4.2 Package list
4.2.1. Package for an assembly on the roof
M001749-A
ER45
M001750-A
EG450
M001751-A
ER67 ER69
4. Installation NEO 2.1 / SUN 211
11
05/10/09 - 300020210-001-B
4.2.2. Anchorage fittings for roof mounting
The roof anchors are not included in the roof-surface installation set and must be ordered separately.
CAUTION
Before installation, make sure that the framework is solid and strong enough to comply with the static requirements.
There are different types of roof anchor available:
4 Aluminium roof anchors for assembly independent of the
chevrons.
4 Rafter-mounted anchors.
4 Hooks to be fitted to the roof covering.
In the first case, additional mounting battens have to be added to the roof structure. In order to fit the mounting battens to the framework of a finished roof, the roof tiles covering the entire length of the mounting battens have to be moved out of the way. The roof anchors are then located on the battens and fixed. With the rafter-mounted type, only individual tiles above the fixing points on the rafters have to be removed. The roof anchors are screwed to the rafters thus exposed. Afterwards, the tiles are replaced and the roof is immediately waterproof again. The installation of the panel-mounting system can start. If installing on metal rooves, the roof anchors must be ordered from the manufacturer of the roof system concerned. The hoses of the solar-panel connection sets can be passed through the roof by feeding them through a vented roof tile.
n
Aluminium roof anchor for long-stringed gutter tile
EG 311 (4 pieces) EG 312 (6 pieces) On tiled rooves, additional mounting battens are added to the roof substructure.
Charateristics of the assembly plates:
4 Cross section: 30 x 90 mm
4 Length: Width of the bank of solar collectors
4 The ends must rest on a chevron
The roof anchors are fixed to these assembly planks (assembly independent of the chevrons).
n
Stainless steel roof anchor for long-stringed gutter tile
EG 313 (4 pieces) EG 314 (6 pieces) These roof anchors are attached directly to the roof rafters (rafter- mounted anchors).
M001741-A
M001742-A
<100
NEO 2.1 / SUN 211
4. Installation
05/10/09 - 300020210-001-B
12
n
Stainless steel roof anchor for flat tiles
EG 315 (4 pieces) EG 316 (6 pieces) These roof anchors are attached directly to the roof rafters (rafter- mounted anchors). Their slim design normally allows two roof anchors to be fixed to one rafter.
n
Stainless steel roof anchor for corrugated rooves
EG 317 (4 pieces) EG 318 (6 pieces) On corrugated rooves (fibrecement, asbestos, etc.) these roof anchors are screwed to the roof rafters through the corrugated sheets (rafter-mounted anchors). They are fixed by coach bolts (not supplied with the roof anchors as they vary depending on the roofing manufacturer).
n
Stainless steel roof anchor for slate
EG 319 (4 pieces) EG 320 (6 pieces) These roof anchors are screwed to the rafters through the boarding (rafter-mounted anchors). The roof anchor then has to be covered in the normal way.
4.2.3. Terrace assembly kit
For terrace assembly, specific kits are available: EG 358, EG 359. Refer to the instructions delivered with the package.
M001743-A
M001744-A
M001745-A
M001747-A
4. Installation NEO 2.1 / SUN 211
13
05/10/09 - 300020210-001-B
Loading...
+ 30 hidden pages