DeDietrich OpenTherm Service Manual

Page 1
EN
Modulating room thermostat
Opentherm Modulating room thermostat
Installation and Service Manual
7616664-01
Page 2
Contents
1 Preface ........................................................................................................2
1.1 General ..................................................................2
2 Location ......................................................................................................3
2.1 Position of the regulator ......................................3
2.2 Installation and connection .................................3
3 Commissioning ..........................................................................................5
3.1 Fitted control unit .................................................5
3.1.1 Control .....................................................................5
3.1.2 Default setting .........................................................5
4 Settings .......................................................................................................6
4.1 Changing the settings ..........................................6
4.1.1 Modifying the temperature ......................................6
4.1.2 Menu structure .......................................................6
4.2 User settings .........................................................7
4.2.1
User menu W ..........................................................7
4.3 Fitter menu ...........................................................7
4.3.1
Information menu Q ...............................................7
4.3.2
Installer menu ? ....................................................8
4.3.3
Counter menu \ ....................................................8
4.3.4
Service menu K ...............................................8
5 Messages ..................................................................................................10
5.1 Error messages ...................................................10
6 Technical specifications ..........................................................................11
6.1 Technical specifications ....................................11
1
31032014 - 7616664-01
Page 3
1 Preface
1.1 General
The Opentherm Modulating room thermostat is a simple modulating room thermostat based on the OpenTherm SmartPower protocol. Certain De Dietrich boiler types offer other functions in addition to the room thermostat function. These functions include setting parameters. See the installation and service manual for the boiler.
This installation and service manual describes all the functions of the Opentherm Modulating room thermostat.
WARNING
OpenTherm SmartPower is required for the backlight. In boilers without OpenTherm , the Opentherm Modulating room thermostat is functional but without backlight.
Opentherm Modulating room thermostat 1. Preface
31032014 - 7616664-01
2
Page 4
2 Location
2.1 Position of the regulator
The controller works using room control. This means that the inside temperature is used to control the central heating.
4 Install the regulator in the reference room (generally the living
room).
4 Do not locate the controller too close to heat sources (fireplace,
radiator, lamp, candles, direct sunlight etc), or in places where it may be draughty.
2.2 Installation and connection
Before you can connect the controller, you must first:
1. Adjust the boiler so that it can be connected to a OpenTherm controller. See the installation and service manual for the boiler.
2. Shut down the boiler.
3. Open the housing by pulling the front and the base plate apart.
4. Attach the base plate to the wall using the screws and plugs supplied. Ensure that the OpenTherm connecting wires for the boiler are poking through the hole in the base plate.
R000083-B
150
cm
R000078-A
R000058-D
Ø6 mm
2. Location
Opentherm Modulating room thermostat
3
31032014 - 7616664-01
Page 5
5. Connect the controller to the OpenTherm connection of the boiler, and to the OT connection of the controller. OpenTherm is not sensitive to polarity. The wires are interchangeable.
6. Place the front panel back in the housing.
R000080-A
OT
On/off
OT
OT
R000081-A
Opentherm Modulating room thermostat 2. Location
31032014 - 7616664-01
4
Page 6
3 Commissioning
3.1 Fitted control unit
3.1.1. Control
1
Display
2
Rotary and push button for setting the controller
The controller is menu-controlled, which means it is very simple to operate. The controller has just 1 button.
4 The button is both a rotary button and a push button.
4 Turn it to scroll through menus or change values.
4 Press it to confirm choices (Such as menu
selections).
n
Meaning of the symbols on the display
Symbol
Meaning Symbol Meaning
T
ECO mode on
>
Back
e
Water pressure too low
Q
Information menu
c
Defect
W
User menu
?
Boiler service required
?
Installer menu
H
Current temperature
\
Counter menu
M
Set temperature
K
Service menu
D
Central heating function on
I
Burner on
N
Domestic hot water function on
3.1.2. Default setting
The controller works using room control (Central heating is controlled on the basis of the inside temperature).
This is the default setting:
4 Set temperature 15
4 ECO AUTO
4 The most recent set temperature is saved
R000057-D
1
2
3. Commissioning Opentherm Modulating room thermostat
5
31032014 - 7616664-01
Page 7
4 Settings
4.1 Changing the settings
4.1.1. Modifying the temperature
1
Set temperature
2
Measured temperature
4 Turn the button to set the ambient temperature.
4 Press the button to confirm.
4.1.2. Menu structure
To access the menu, proceed as follows:
4 Press the rotary and push button for at least 3 sec.
4 Turn the button until you reach the required menu.
4 Press the button to confirm.
4 Amend the selected menu item.
4 Press the button to confirm. 4 Exit the menu by pressing >.
WARNING
The values to be read may differ depending on the connected heating unit. See the installation and service manual for the boiler.
R000077-A
1
2
R000064-C
3s
1x
Opentherm Modulating room thermostat 4. Settings
31032014 - 7616664-01
6
Page 8
4.2 User settings
4.2.1.
User menu W
Code Meaning Information Settings Factory
setting
em;
DHW standby function
The ECO mode turns off the DHW standby function. In combi boilers the waiting time increases. Calorifiers are no longer kept warm.
Zvt; = Automatic position 0M = Start 0ff = Stop
Zvt;
tdh
Tap water temperature
Setting the required tap water temperature, for calorifiers with a temperature programme.
30 to 75 °C
60°C N
tmh
Maximum central heating water temperature
Setting the required central heating water temperature.
0 to 100 °C
90°C D
hvp
Heating rate
Setting how fast or slow the controller responds.
2 = Fastest 1 = Faster 0 = Normal z1 = Slower z2 = Slowest z3 = Extra Slow
0
cdM
Cooling rate
Indicate how fast or slow the house cools down. A well insulated house will cool down slower.
2 = Fastest 1 = Faster 0 = Normal z1 = Slower z2 = Slowest
0
4.3 Fitter menu
4.3.1.
Information menu Q
This menu provides access to various kinds of information about the boiler and any connected accessories.
Symbol
Meaning
5t
State
5v
Sub-status
tf
Current inlet temperature (℃)
tr
Current return temperature (℃)
tdh
Current tank temperature (℃) (Only if an DHW sensor is connected)
t;vt
Current outside temperature (℃) (Only if an outside temperature sensor is connected)
t5;l
Current solar tank temperature (℃) (Only with the sensor connected)
fl
Current ionization current
Mf
Current fan speed omw/min
4. Settings Opentherm Modulating room thermostat
7
31032014 - 7616664-01
Page 9
Symbol Meaning
pr
Current water pressure (Only boilers with a water pressure sensor)
p;
Current heat output of boiler
5;ft
Control system software version
4.3.2.
Installer menu ?
In this menu, the installer can—depending on the boiler—adjust some of the functions and access information.
The following is applicable to all installer settings: 4 The values to be read may differ depending on the
connected heating unit.
4 The meaning of the various codes may differ for
different boilers.
4 After selection of a parameter, it takes 1 s before the
parameter is retrieved.
Settings > Installer menu ? 0012
Settings
P001
to
P015
Consult the boiler manual when changing the boiler parameters. If an invalid value is entered, fk1l appears on the screen.
dfdV
Revert to the factory settings. See the installation and service manual for the boiler.
Zd
Carrying out an auto-detect. See the installation and service manual for the boiler.
4.3.3.
Counter menu \
The history of various boiler functions can be checked in this menu.
Settings > Counter menu \
Code
Meaning
m1
Unsuccessful starts
m2
Number of times with no or low flame
m3
Number of successful starts
m4
Number of central heating pump starts
m5
Number of DHW pump starts
m6
Number of DHW burner starts
m7
Total operating hours
m8
Number of central heating pump operating hours
m9
Number of DHW pump operating hours
4.3.4.
Service menu K
Boiler service messages can be reset here.
Opentherm Modulating room thermostat
4. Settings
31032014 - 7616664-01
8
Page 10
Settings > Service menu K
WARNING
Reset the service message after the boiler service has been carried out. This can be the active message or the next message.
4 If zzzz is displayed in the service menu, the
boiler will not show a service code.
4 The mleZr message indicates that a (pre-)
service reset is possible. The message mleZr Z, B or c indicates that service message Z, B or c can be reset.
4 The boiler determines which service message can be
reset.
Code Meaning
mleZr
Service reset
Only a qualified engineer may carry out the following operations.
When the mleZr message is displayed, you can choose to either retain the service message or reset it. If no action is taken, the service message will remain. To reset the service message, proceed as follows:
1. Press the rotary and push button.
2. Turn the button to
ml[ye5
.
3. Press the button to confirm.
4. The controller will then return to the
zzzz
screen.
Multiple resets are not possible.
Operations to be carried out
K
mleZr Z B c
K
Z ml[ n0
K
Z ml[ye5
4. Settings Opentherm Modulating room thermostat
9
31032014 - 7616664-01
Page 11
5 Messages
5.1 Error messages
If an error is present, a fault code and a fault indication will appear on the display.
Error codes
Fault indication
Probable causes Solution
f203
c
Faulty connection to boiler. Check the boiler’s connection to the controller.
f214
c
Incorrect room temperature reading.
Room temperature reading is incorrect. The temperature sensor may be defective if the room temperature is between -5℃ and 65℃.
Contact your installer.
f215
c
Controller failure. Contact your installer
f217
c + e
Water pressure too low. Top up the water in the central heating system. See the
installation and service manual for the boiler.
n; 5p
c
Your boiler may not support the OpenTherm SmartPower.
OpenTherm SmartPower is required for the backlight. In boilers without OpenTherm SmartPower, the Opentherm
Modulating room thermostat is functional but without backlight. To clear the message, press the button.
R000125-A
Opentherm Modulating room thermostat 5. Messages
31032014 - 7616664-01
10
Page 12
6 Technical specifications
6.1 Technical specifications
Dimensions
80 x 90 x 32,5 (l x b x h) mm
Power supply
OpenTherm regulator OpenTherm
Electrical connection
OpenTherm regulator OpenTherm communication. Low-voltage connection
Ambient conditions
Storage conditions Temperature: -25℃ +60℃
Relative humidity 5% - 90% no condensation
Operating conditions 0℃ - 60℃
Temperature
Room temperature Measurement range: -5℃ +65℃
Maximum temperature deviation at 20℃: 0,3℃
Temperature control area 5 - 35℃
Adjustment Modulating temperature control
The control can be optimised
Room control Overshoot: Maximum 1℃ after pre-heating
Temperature variation: Less than 0,25℃
Adjustment strategies Adjustment of the room temperature
Features of the controller
Backlight Colour: blue
Control precision Temperature: 0,5℃
Control Rotary and push button
Mounting Directly on the wall using screws. Or built-in junction box as per standards
Quality marks and compliance with standards
4 EMC: 2004/108/EC, 55014
4 Emission EN61000-6-3
4 Immunity EN61000-6-2
4 Drop test IEC 68-2-32
4 RoHs Compliant
4 OpenTherm V3.0 Smartpower
Protection classification IP20
6. Technical specifications Opentherm Modulating room thermostat
11
31032014 - 7616664-01
Page 13
Opentherm Modulating room thermostat 6. Technical specifications
31032014 - 7616664-01
12
Page 14
Page 15
Page 16
AD001-AI
DUEDI S.r.l.
DE DIETRICH SERVICE
BDR Thermea (Czech republic) s.r.o
www.duediclima.it
www.dedietrich.cz
Distributore Ufficiale Esclusivo
De Dietrich-Thermique Italia
www.dedietrich-heiztechnik.com
Freecall 0800 / 201608
Jeseniova 2770/56
130 00 Praha 3
+49 (0)25 72 / 9161-0
+49 (0)25 72 / 9161-102
info@remeha.de
Via Passatore, 12 - 12010 San Defendente di Cervasca CUNEO
+39 0171 857170 +39 0171 687875 info@duediclima.it
+420 271 001 627 info@dedietrich.cz
IT
DE DIETRICH THERMIQUE S.A.S
DE DIETRICH THERMIQUE Iberia S.L.U.
www.dedietrich-calefaccion.es
C/Salvador Espriu, 11
08908 L’HOSPITALET de LLOBREGAT
+34 935 475 850 info@dedietrich-calefaccion.es
ES
129164, Россия, г. Москва
Зубарев переулок, д. 15/1
Бизнес-центр «Чайка Плаза»,
офис 309
+7 (495) 221-31-51
CZ
© Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing.
31032014
7616664
DEDIETRICH THERMIQUE 57,ruedelaGareF-67580MERTZWILLER-BP 30
Loading...