DeDietrich BESL 300, BSL 300 User Manual

Page 1
UNO
EN
Solar hot water calorifer
BSL 200...400 BESL 200...400
L000541-B
300028413-001-A
Page 2
Contents
1 Introduction ................................................................................................4
1.1 Symbols used .......................................................4
1.1.1 Symbols used in the manual ...................................4
1.1.2 Symbols used on the equipment .............................4
1.2 Abbreviations ........................................................4
1.3 General ..................................................................5
1.3.1 Manufacturer's liability .............................................5
1.3.2 Installer's liability .....................................................5
1.3.3 User's liability ..........................................................5
1.4 Homologations ......................................................6
1.4.1 Certifications ...........................................................6
2 Safety instructions and recommendations ..............................................7
2.1 Safety instructions ...............................................7
2.2 Recommendations ................................................7
3 Technical description ................................................................................9
3.1 Main parts ..............................................................9
3.1.1 Solar domestic hot water calorifier ..........................9
3.2 Control panels .....................................................10
3.2.1 Description of the keys ..........................................10
3.2.2 Description of the display ......................................11
4 Operating the appliance ..........................................................................13
4.1 Reading out measured values ...........................13
4.1.1 Resetting the values to zero ..................................13
4.2 User settings .......................................................14
4.2.1 Setting the time .....................................................14
4.2.2 Force back-up .......................................................14
4.2.3 Modifying the back-up authorisations ....................14
4.2.4 In the event of prolonged absences ......................14
4.3 Setting the DHW calorifier outlet
temperature .........................................................15
4.3.1 Programming and setting the electrical back-
up ..........................................................................15
4.3.2 Setting the thermostatic mixing valve ....................16
1
11/06/2012 - 300028413-001-A
Page 3
4.4 Starting and stopping the control system ........16
5 Checking and maintenance .....................................................................17
5.1 General instructions ...........................................17
5.2 Safety valve or safety unit .................................17
5.3 Cleaning the casing material .............................17
5.4 Checking the magnesium anode .......................17
6 Troubleshooting .......................................................................................18
6.1 Incidents and solutions ......................................18
7 Technical specifications ..........................................................................19
7.1 Solar domestic hot water calorifier ...................19
7.2 Composition of the NF CESI solar systems
packages (For France) .......................................20
8 Warranty ....................................................................................................23
8.1 General ................................................................23
8.2 Warranty terms ...................................................23
Contents
2
11/06/2012 - 300028413-001-A
Page 4
3
11/06/2012 - 300028413-001-A
Page 5
1 Introduction
1.1 Symbols used
1.1.1. Symbols used in the manual
In these instructions, various danger levels are employed to draw the user's attention to particular information. In so doing, we wish to safeguard the user's safety, obviate hazards and guarantee correct operation of the appliance.
DANGER
Risk of a dangerous situation causing serious physical injury.
WARNING
Risk of a dangerous situation causing slight physical injury.
CAUTION
Risk of material damage.
Signals important information.
¼ Signals a referral to other instructions or other pages in the instructions.
1.1.2. Symbols used on the equipment
Before installing and commissioning the device, read carefully the instruction manuals provided.
Dispose of the used products in an appropriate recovery and recycling structure.
1.2 Abbreviations
4 CFC: Chlorofluorocarbon
4 DHW: Domestic hot water
BSL 200...400 BESL 200...400
1. Introduction
11/06/2012 - 300028413-001-A
4
Page 6
1.3 General
1.3.1. Manufacturer's liability
Our products are manufactured in compliance with the requirements of the various applicable European Directives. They are therefore
delivered with [ marking and all relevant documentation.
In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice.
Our liability as the manufacturer may not be invoked in the following cases:
4 Failure to abide by the instructions on using the appliance.
4 Faulty or insufficient maintenance of the appliance.
4 Failure to abide by the instructions on installing the appliance.
1.3.2. Installer's liability
The installer is responsible for the installation and inital start up of the appliance. The installer must respect the following instructions:
4 Read and follow the instructions given in the manuals provided
with the appliance.
4 Carry out installation in compliance with the prevailing legislation
and standards.
4 Perform the initial start up and carry out any checks necessary.
4 Explain the installation to the user.
4 If a maintenance is necessary, warn the user of the obligation to
check the appliance and maintain it in good working order.
4 Give all the instruction manuals to the user.
1.3.3. User's liability
To guarantee optimum operation of the appliance, the user must respect the following instructions:
4 Read and follow the instructions given in the manuals provided
with the appliance.
4 Call on qualified professionals to carry out installation and initial
start up.
4 Get your installer to explain your installation to you.
4 To carry out inspections and maintenance required by a qualified
professional.
4 Keep the instruction manuals in good condition close to the
appliance.
1. Introduction
BSL 200...400 BESL 200...400
5
11/06/2012 - 300028413-001-A
Page 7
This appliance is not intended to be used by persons (including children) whose physcial, sensory or mental capacity is impaired or persons with no experience or knowledge, unless they have the benefit, through the intermediary of a person responsible for their safety, of supervision or prior instructions regarding use of the appliance. Care should be taken to ensure that children do not play with the appliance.
1.4 Homologations
1.4.1. Certifications
This product complies to the requirements to the european directives and following standards:
4 2006/95/EC Low Voltage Directive.
Reference Standard: EN 60.335.1.
4 2004/108/EC Electromagnetic Compatibility Directive.
Reference Standards: EN 50.081.1, EN 50.082.1, EN 55.014
BSL 200...400 BESL 200...400 1. Introduction
11/06/2012 - 300028413-001-A
6
Page 8
2 Safety instructions and
recommendations
2.1 Safety instructions
DANGER
If smoke is released or in case of refrigerant leak:
1. Switch the appliance off.
2. Open the windows.
3. Evacuate the premises.
4. Contact a qualified professional.
CAUTION
Do not neglect to service the appliance. Contact a qualified professional or take out a maintenance contract for the annual servicing of the appliance.
CAUTION
Before any work, switch off the mains supply to the appliance.
2.2 Recommendations
WARNING
Only qualified professionals are authorised to work on the appliance and the installation. Never drain the installation. Do not replace or add water or solar fluid to the installation. These actions must be carried out by a qualified technician
To take advantage of the guarantee, no modifications must be made to the appliance. Only remove the covers for maintenance and breakdown repair operations and put the covers back in place after the maintenance and breakdown repair operations.
Instructions stickers
The instructions and warnings affixed to the appliance must never be removed or covered and must remain legible during the entire lifespan of the appliance. Immediately replace damaged or illegible instructions and warning stickers.
2. Safety instructions and recommendations
BSL 200...400 BESL 200...400
7
11/06/2012 - 300028413-001-A
Page 9
WARNING
Never cut the power to the solar control system, even during extended absences. The control system protects the installation against overheating in summer when it is running.
WARNING
Do not modify the control system parameters unless fully conversant with them.
During extended absences, we recommend lowering the set point temperature in the solar DHW calorifier to 45°C. When the user is present, the set point must be set to 60°C.
BSL 200...400 BESL 200...400 2. Safety instructions and recommendations
11/06/2012 - 300028413-001-A
8
Page 10
3 Technical description
3.1 Main parts
3.1.1. Solar domestic hot water calorifier
BSL 200...400: External view
A
Expansion vessel
Z
Top inspection trap
E
Side inspection plate
R
Solar station
T
Solar regulator
Y
Electrical back-up (Option)
U
Safety control unit for the solar circuit
All components are checked for leaks and tested in the factory. The control system, the pump and the electrical back-up are pre-wired.
L000430-C
5
7
4
6
1
2
3
3. Technical description BSL 200...400 BESL 200...400
9
11/06/2012 - 300028413-001-A
Page 11
BESL 200...400: External view
A
Expansion vessel
Z
Top inspection trap
E
Side inspection plate
R
Solar station
T
Solar regulator
Y
Electrical back-up
U
Safety control unit for the solar circuit
All components are checked for leaks and tested in the factory. The control system, the pump and the electrical back-up are pre-wired.
3.2 Control panels
3.2.1. Description of the keys
A
Key ) :
4 Move the cursor upwards.
4 Increase the value of parameter .
B
Key B :
4 Access a selected parameter.
4 Confirm a value modification.
C
Key ( :
4 Move the cursor downwards.
4 Reduce the parameter value.
D 3-position switch:
4 E : The back-up may be active in day mode and
night mode.
4 0: The back-up is deactivated. 4 Z : The back-up is active in night mode only.
L000431-C
2
3
5
4
6
1
7
M002759-A
A
B
C
D
BSL 200...400 BESL 200...400 3. Technical description
11/06/2012 - 300028413-001-A
10
Page 12
3.2.2. Description of the display
n
System schematics (System-Screen)
A
Solar sensor probe
Z
Solar collectors
E
solar heating pump
R
Solar exchanger
T
Solar hot water calorifer
Y
Solar sensor
U
Back-up
I
DHW sensor - Back-up
n
Operating indicators
Steady symbol
Flashing symbol
State
K
Solar pump activated.
%
Back-up activated.
Z
DHW calorifer set point temperature exceeded.
K
Z
Cooling function of the collector or DHW calorifer activated.
E
Antifreeze function activated.
K
E
Antifreeze function active (running).
E
Minumum collector temperature exceeded.
a Z
Maximum DHW tank temperature exceeded.
a
Maximum collector temperature exceeded.
T
Adjustment parameter.
T
Changing the settings.
] a
Sensor fault.
R + K a
Forcing of the solar pump.
R + %
a
Forcing of the electrical back-up.
M002760-A
1
4 5
2
3
7
8
6
M002761-A
II I
3. Technical description BSL 200...400 BESL 200...400
11
11/06/2012 - 300028413-001-A
Page 13
n
LED display
A
LED
LED message code
Heating pump status Description
Continuously green
PUMPE relay is closed.
Regulation operating normally (System Operating).
Flashing green/ red
4 Initialisation
phase
4 Manual mode
4 The installation is in
manual mode: Set the regulator to automatic mode.
Flashing red
4 Sensor fault.
4 Maximum tank
temperature exceeded.
4 The hot water tank has
reached the set temperature and the installation is in overheating safety mode or in cooling mode.
4 There is a sensor fault.
M002762-A
A
BSL 200...400 BESL 200...400 3. Technical description
11/06/2012 - 300028413-001-A
12
Page 14
4 Operating the appliance
4.1 Reading out measured values
Scroll down the values measured using the ( and ) keys.
Parameter Description Remarks
TC
Collector temperature S1 sensor.
The value TC shows the temperature in °C given by the collector sensor in real time.
TR
Calorifier temperature (Solar exchanger ­lower)
S2 sensor. The value TR shows the temperature in °C in real time measured by the sensor in the lower
zone of the DHW calorifier.
THR
Calorifier temperature (Back-up)
S3 sensor. The value THR shows the temperature in °C in real time measured by the sensor in the
upper zone of the DHW tank.
PC %
Pump regime Value PC % gives the solar heating pump regime in real time (0-100%).
tc
Auto-calibration time The value tc shows the self-calibration phase time remaining in seconds.
RAP
Force back-up On: Back-up powered up.
AUTO: Back-up managed by the control system.
¼ See chapter: "Force back-up", page 14.
h P1
Hour run meter on the solar pump
Reset to zero possible.
¼ See chapter: "Resetting the values to zero", page 13.
h P2
Hour run meter on the electrical back-up
Reset to zero possible.
¼ See chapter: "Resetting the values to zero", page 13.
KWh
Amount of heat (kWh)
4 The amount of heat received is calculated according to the parameters input on
commissioning (DMAX).
4 Reset to zero possible.
¼ See chapter: "Resetting the values to zero", page 13.
Values KWh or MWh give an estimate of the total amount of heat produced by the installation in kWh or MWh since commissioning of the control system. The amount of heat received is calculated according to the parameters input on commissioning (DMAX).
MWh
Amount of heat (MWh)
HRE
Time
¼ See chapter: "Setting the time", page 14.
4.1.1. Resetting the values to zero
It is possible to reset the value to zero when the letter T is displayed.
1. Select a value using the ( and ) keys.
2. Press the B key for 2 seconds. The value is reset to zero.
To suspend the operation, do not press any keys for 5 seconds. The control system will automatically go back to the value display mode.
4. Operating the appliance BSL 200...400 BESL 200...400
13
11/06/2012 - 300028413-001-A
Page 15
4.2 User settings
4.2.1. Setting the time
1. Select the HRE channel with the ( and ) keys.
2. Press the B key for 2 seconds.
3. Set the hour with the ( and ) keys.
4. Press the B key to confirm.
5. Set the minutes with the ( and ) keys.
6. Press the B key to confirm.
CAUTION
The controller does not switch between summer and winter time.
4.2.2. Force back-up
1. Select the RAP channel with the ( and ) keys.
2. Press the B key for 2 seconds. The symbol T flashes.
3. Set the RAP parameter to ON using the ) key.
4. Press the B key to confirm the setting.
The electrical back-up shuts down when the set point temperature is attained.
4.2.3. Modifying the back-up authorisations
Throw the switch to modify the electrical back-up authorisations.
E
Winter: Electrical back-up is authorised day and night.
0 Electrical back-up is not authorised. No back-up heating.
Z
Summer: Electrical back-up is only authorised at night.
The back-up is deactivated if the solar pump is running.
4.2.4. In the event of prolonged absences
In the event of prolonged absence, shut down the electrical back-up and reduce the solar calorifier set point:
M002763-A
BSL 200...400 BESL 200...400
4. Operating the appliance
11/06/2012 - 300028413-001-A
14
Page 16
1. Set the 3-position switch to 0.
2. Advance to the last display channel (HRE) with the ( key.
3. Press the ( key for 5 seconds. A setting parameter is displayed, with the symbol T.
4. Select parameter SX using keys ) and (.
5. Briefly press the B key. The symbol T flashes, the parameter can be set.
6. Modify the parameter using the ( and ) keys. For example 45(°C).
7. Press B to confirm the setting.
n
Return from prolonged absence
On return from a prolonged absence:
4 Adjust the set point of the solar calorifier SX to its installation value.
4 Re-authorise the back-ups.
4 Set the 3-position switch to winter or summer, according to the
season.
4.3 Setting the DHW calorifier outlet temperature
4.3.1. Programming and setting the electrical
back-up
The temperature of the volume of water heated by the electrical resistor is set by the installer on commissioning of the installation according to the size of the home. Using the solar control system, it is possible to adjust the volume of water heated to 40 °C by the resistor in two ways:
4 Force the continuous heating of the resistor for significant
unforeseen needs. ¼ See chapter: "Force back-up", page 14.
4 Select winter mode w (2 hours maximum according to the volume
of the domestic hot water required at 40 °C) to compensate for the lack of sun in winter. If necessary, the period scheduled outside of the off-peak hours is set between 16:00 and 18:00, i.e at the end of the day when the solar contribution is reduced and just before the drawing off period.
¼ See chapter: "Modifying the back-up authorisations", page
14.
I
M002799-A
4. Operating the appliance
BSL 200...400 BESL 200...400
15
11/06/2012 - 300028413-001-A
Page 17
4.3.2. Setting the thermostatic mixing valve
28
Domestic cold water inlet
57
Domestic hot water outlet
The mixing valve is set in the factory for a DHW outlet temperature of 60°C (position 6). To lower this temperature, remove the top cover and turn the wheel anti-clockwise. In position 1, the outlet temperature is lowered to 35°C.
Position 1 2 3 4 5 6
Temperature at the mixer valve outlet 35 °C 40 °C 45 °C 50 °C 55 °C 60 °C
4.4 Starting and stopping the control system
CAUTION
If the temperature in the solar collectors is higher than 130°C, the control system operates in safety mode. Wait until the evening before start-up or cool down (cover) the solar collectors.
Commissioning is performed by the installer. Once connected to the power supply, the control system is in automatic mode. To disconnect the solar pump, a minimum temperature of 30 °C is required at the collector and a temperature difference of 6 °C with respect to the domestic hot water calorifier.
If the particular conditions make it necessary to adjust the settings, contact the installer.
C003732-A
57
28
BSL 200...400 BESL 200...400 4. Operating the appliance
11/06/2012 - 300028413-001-A
16
Page 18
5 Checking and maintenance
5.1 General instructions
CAUTION
4 Maintenance operations must be done by a qualified
engineer.
4 Only original spare parts must be used.
5.2 Safety valve or safety unit
The safety valve or unit on the domestic cold water inlet must be operated at least once a month to ensure proper operating and to prevent from any overpressure which may that may damage the domestic hot water calorifier.
WARNING
Failure to abide by this maintenance rule may damage the domestic hot water calorifier and void its warranty.
5.3 Cleaning the casing material
Clean the outside of appliances using a damp cloth and a mild detergent.
5.4 Checking the magnesium anode
The magnesium anode must be checked at least every 2 years. After the first check, determine the frequency of future checks on the basis of anode wear.
5. Checking and maintenance
BSL 200...400 BESL 200...400
17
11/06/2012 - 300028413-001-A
Page 19
6 Troubleshooting
6.1 Incidents and solutions
Description Checks Solutions
The pilot light is off. The current has been cut. Restore the current.
BSL 200...400 BESL 200...400 6. Troubleshooting
11/06/2012 - 300028413-001-A
18
Page 20
7 Technical specifications
7.1 Solar domestic hot water calorifier
BSL 200 BSL 300 BSL 400
Primary circuit: Solar exchanger
Maximum operating temperature °C 110 110 110
Maximum operating pressure bar 10 10 10
Exchanger capacity litres 5.6 8.1 10.1
Exchange surface
m
2
0.84 1.2 1.5
Primary circuit: Back-up exchanger
Maximum operating temperature °C 110 110 110
Maximum operating pressure bar 10 10 10
Exchanger capacity litres 5.1 5.1 5.1
Exchange surface
m
2
0.76 0.76 0.76
Pressure drop at 2 m3/Time
kPa 4 4 4
Secondary circuit (domestic water)
Maximum operating temperature °C 95 95 95
Maximum operating pressure bar 10 10 10
Water content litres 225 300 395
Top up volume litres 75 105 150
Solar volume litres 150 195 245
Weight
Gross weight kg 125 125 158
Net weight kg 109 111.5 145
Performance Primary circuit: Back-up exchanger
Power exchanged
(1)
kW 24 24 24
Performance
Flow per hour (∆T = 35 °C
(1)
litres per hour 590 590 590
Transfer capacity over 10 minutes (∆T = 30°C)
(2)
litres per 10 min. 150 200 270
Cooling constant Cr Wh/24h·L·K 0.23 0.20 0.18
Maintenance consumption (ΔT=45K) kWh/24h 1.8 2.2 2.6
Performance N
L
0.7 1.2 2.7
(1) Primary temperature: 80 °C - Domestic cold water inlet: 10 °C - Domestic hot water outlet: 45 °C - Primary flow rate: 2 m3/h (2) Primary temperature: 80 °C - Domestic cold water inlet: 10 °C - Domestic hot water outlet: 40 °C - Domestic hot water storage: 65 °C
BESL 200 BESL 300 BESL 400
Primary circuit: Solar exchanger
Maximum operating temperature °C 110 110 110
Maximum operating pressure bar 10 10 10
Exchanger capacity litres 5.6 8.1 10.1
Exchange surface
m
2
0.84 1.2 1.5
Secondary circuit (domestic water)
Maximum operating temperature °C 95 95 95
Maximum operating pressure bar 10 10 10
7. Technical specifications BSL 200...400 BESL 200...400
19
11/06/2012 - 300028413-001-A
Page 21
BESL 200 BESL 300 BESL 400
Water content litres 225 300 395
Top up volume (Electric) litres 95 135 170
Solar volume litres 130 165 225
Weight
Gross weight kg 115 114 138
Net weight kg 100 102 126
Performance
Cooling constant Cr Wh/24h·L·K 0.23 0.20 0.18
Maintenance consumption (ΔT=45K) kWh/24h 1.8 2.2 2.6
7.2 Composition of the NF CESI solar systems packages (For France)
Check the composition of the NF CESI solar system package against the table below. The references and packages listed must be shown on the invoice for the system sold by the installer.
A system is complete and functional according to the NF CESI mark if all system references appear on the invoice. The system is composed of the following elements:
4 A collector field with 1,2 or 3 solar collectors.
4 A solar calorifier for domestic hot water consists of a solar station,
a heating pump, an expansion vessel and a control system.
4 The solar fluid that protects the installation from frost and
corrosion.
The system is delivered to the installer in two units: a roof pack containing the collectors, their mounting system and the hydraulic connections on the one hand, and a cellar pack containing the calorifier, the system components and the solar fluid on the other hand.
CESI System INISOL
Array of collectors Domestic hot water production Solar fluid
Type of mounting
package / Reference
DHW calorifier type/Model
package / Reference
Volume (litres)
Back-up package /
Reference
UNO NE 200 - 2
(1 collector)
On roof
ER 152 100014074
BESL 200
ER 372
100019140
200 Electric
EG 101
89807794
Roof-integral Installation (>20°)
ER 153 100014075
Roof-integral Installation (17°)
ER 230 100014740
UNO NE 200 - 4
(2 panels)
On roof
ER 154 100014076
BESL 200
ER 372
100019140
200 Electric
EG 101
89807794
Roof-integral Installation (>20°)
ER 155 100014077
Roof-integral Installation (17°)
ER 231 100014741
BSL 200...400 BESL 200...400 7. Technical specifications
11/06/2012 - 300028413-001-A
20
Page 22
CESI System INISOL
Array of collectors Domestic hot water production Solar fluid
Type of mounting
package / Reference
DHW calorifier type/Model
package / Reference
Volume (litres)
Back-up package /
Reference
UNO NE 300 - 4
(2 panels)
On roof
ER 154 100014076
BESL 300
ER 373
100019141
300 Electric
EG 101
89807794
Roof-integral Installation (>20°)
ER 155 100014077
Roof-integral Installation (17°)
ER 231 100014741
UNO NE 300 - 6
(3 panels)
On roof
ER 156 100014078
BESL 300
ER 373
100019141
300 Electric
EG 101
89807794
Roof-integral Installation (>20°)
ER 157 100014079
Roof-integral Installation (17°)
ER 232 100014742
UNO NE 400 - 4
(2 panels)
On roof
ER 154 100014076
BESL 400
ER 374
100019142
400 Electric
EG 101
89807794
Roof-integral Installation (>20°)
ER 155 100014077
Roof-integral Installation (17°)
ER 231 100014741
UNO NE 400 - 6
(3 panels)
On roof
ER 156 100014078
BESL 400
ER 374
100019142
400 Electric
EG 101
89807794
Roof-integral Installation (>20°)
ER 157 100014079
Roof-integral Installation (17°)
ER 232 100014742
UNO N 200 - 2
(1 collector)
On roof
ER 152 100014074
BSL 200
ER 359
100019134
200 Boiler
EG 101
89807794
Roof-integral Installation (>20°)
ER 153 100014075
Roof-integral Installation (17°)
ER 230 100014740
UNO N 200 - 4
(2 panels)
On roof
ER 154 100014076
BSL 200
ER 359
100019134
200 Boiler
EG 101
89807794
Roof-integral Installation (>20°)
ER 155 100014077
Roof-integral Installation (17°)
ER 231 100014741
UNO N 300 - 4
(2 panels)
On roof
ER 154 100014076
BSL 300
ER 360
100019135
300 Boiler
EG 101
89807794
Roof-integral Installation (>20°)
ER 155 100014077
Roof-integral Installation (17°)
ER 231 100014741
7. Technical specifications BSL 200...400 BESL 200...400
21
11/06/2012 - 300028413-001-A
Page 23
CESI System INISOL
Array of collectors Domestic hot water production Solar fluid
Type of mounting
package / Reference
DHW calorifier type/Model
package / Reference
Volume (litres)
Back-up package /
Reference
UNO N 300 - 6
(3 panels)
On roof
ER 156 100014078
BSL 300
ER 360
100019135
300 Boiler
EG 101
89807794
Roof-integral Installation (>20°)
ER 157 100014079
Roof-integral Installation (17°)
ER 232 100014742
UNO N 400 - 4
(2 panels)
On roof
ER 154 100014076
BSL 400
ER 361
100019136
400 Boiler
EG 101
89807794
Roof-integral Installation (>20°)
ER 155 100014077
Roof-integral Installation (17°)
ER 231 100014741
UNO N 400 - 6
(3 panels)
On roof
ER 156 100014078
BSL 400
ER 361
100019136
400 Boiler
EG 101
89807794
Roof-integral Installation (>20°)
ER 157 100014079
Roof-integral Installation (17°)
ER 232 100014742
BSL 200...400 BESL 200...400 7. Technical specifications
11/06/2012 - 300028413-001-A
22
Page 24
8 Warranty
8.1 General
You have just purchased one of our appliances and we thank you for the trust you have placed in our products.
Please note that your appliance will provide good service for a longer period of time if it is regularly checked and maintained.
Your fitter and our customer support network are at your disposal at all times.
8.2 Warranty terms
France: The following provisions are not exlcusive of the buyer being
able to benefit from the legal warranty stipulated in Articles 1641 to 1648 of the Civil Code.
Belgium: The following provisions regarding the contractual warranty are not exclusive of the buyer being able to benefit from the legal provisions applicable in Belgium regarding hidden defects.
Switzerland: The application of the warranty is subject to the terms and conditions of sale, delivery and warranty of the company marketing De Dietrich products.
Portugal: The following provisions do not adversely affect consumers' rights, as laid down in Decree-Law 67/2003 of 8 April amended by Decree-Law 84/2008 of 21 May, warranties relating to sales of consumer goods and other implementing rules.
Other countries: The following provisions are not exclusive of the buyer being able benefit from the legal provisions applicable regarding hidden defects in the buyer's country.
Starting from the purchase date shown on the original fitter's invoice, your appliance has a contractual guarantee against any manufacturing defect.
The length of the guarantee is mentioned in the price catalogue. The manufacturer is not liable for any improper use of the appliance or failure to maintain or install the unit correctly (the user shall take care to ensure that the system is installed by a qualified engineer).
In particular, the manufacturer shall not be held responsible for any damage, loss or injury caused by installations which do not comply with the following:
4 applicable local laws and regulations,
4 specific requirements relating to the installation, such as national
and/or local regulations,
4 the manufacturer's instructions, in particular those relating to the
regular maintenance of the unit,
4 the rules of the profession.
8. Warranty
BSL 200...400 BESL 200...400
23
11/06/2012 - 300028413-001-A
Page 25
The warranty is limited to the exchange or repair of such parts as have been recognised to be faulty by our technical department and does not cover labour, travel and carriage costs.
The warranty shall not apply to the replacement or repair of parts damaged by normal wear and tear, negligence, repairs by unqualified parties, faulty or insufficient monitoring and maintenance, faulty power supply or the use of unsuitable fuel.
Sub-assemblies such as motors, pumps, electric valves etc. are guaranteed only if they have never been dismantled.
The legislation laid down by european directive 99/44/EEC, transposed by legislative decree No. 24 of 2 February 2002 published in O.J. No. 57 of 8 March 2002, continues to apply.
BSL 200...400 BESL 200...400 8. Warranty
11/06/2012 - 300028413-001-A
24
Page 26
Page 27
Page 28
DUEDI S.r.l.
www.duediclima.it
Distributore Ufficiale Esclusivo
De Dietrich-Thermique Italia
Via Passatore, 12 - 12010 San Defendente di Cervasca CUNEO
+39 0171 857170 +39 0171 687875 info@duediclima.it
IT
DE DIETRICH THERMIQUE Iberia S.L.U.
DE DIETRICH THERMIQUE S.A.S
www.dedietrich-calefaccion.es
Av. Princep d’Astúries 43-45
08012 BARCELONA
+34 932 920 520 +34 932 184 709
ES
AD001NU-AH
129164, Россия, г. Москва
Зубарев переулок, д. 15/1
Бизнес-центр «Чайка Плаза»,
офис 309
+7 (495) 221-31-51
© Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing.
11/06/2012
3000284 13 - 00 1- A
DEDIETRICH THERMIQUE 57,ruedelaGareF-67580MERTZWILLER-BP 30
Loading...