DeDietrich AWHP 4MR–EMC 34/39 MI HYBRIDE, AWHP 8MR–EMC 24/28 MI HYBRIDE, AWHP 4MR–EMC 24/28 MI HYBRIDE, AWHP 6MR–EMC 24/28 MI HYBRIDE, AWHP 6MR–EMC 34/39 MI HYBRIDE User Manual

...
en
User Manual
Hybrid heat pump
Alezio G hybrid
AWHP 4MR–EMC 24/28 MI HYBRIDE AWHP 4MR–EMC 34/39 MI HYBRIDE AWHP 6MR–EMC 24/28 MI HYBRIDE AWHP 6MR–EMC 34/39 MI HYBRIDE AWHP 8MR–EMC 24/28 MI HYBRIDE AWHP 8MR–EMC 34/39 MI HYBRIDE
Dear Customer,
Please read through the manual carefully before using the product, and keep it in a safe place for later reference.
In order to ensure continued safe and efficient operation we recommend that the product is serviced regularly. Our service and customer service organisation can assist with this.
We hope you enjoy years of problem-free operation with the product.
Contents
1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.3 Specific safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.3.1 Refrigerant fluid R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.4 Liabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.4.1 User's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.4.2 Installer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
1.4.3 Manufacturer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2 About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.2 Additional documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.3 Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.3.1 Symbols used in the manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.3.2 Symbols used on the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
3 Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.1 Homologations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.1.1 Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
3.1.2 Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.1.3 Unit categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
3.1.4 Factory test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.2 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
3.2.1 Boiler specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
3.2.2 Heat pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.2.3 Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.2.4 Technical data - Low-temperature heat pump combination heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.2.5 Hydraulic module circulating pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4 Description of the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.1 General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
4.2 Operating principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.3 Main components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.3.1 Main boiler components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
4.3.2 Main components of the hydraulic module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.4 Control panel description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.4.1 Description of the keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.4.2 Description of the display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
5.1 Use of the control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.1.1 Accessing the parameters of a PCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.1.2 Browsing in the menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
5.1.3 Accessing the User menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5.1.4 Accessing the COUNTERS / TIME PROG / CLOCK sub-menus PROG COOL . . . . . . . . . . . . . . . . . . . . . . 29
5.2 Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
5.3 Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
5.3.1 Switching off the heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
5.3.2 Shutting down the cooling function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5.4 Frost Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
6 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.1 List of parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.1.1 Menu List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.1.2 Information menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
6.1.3 PCB User Menu EHC-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
6.1.4 PCB parameters SCB-04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
6.1.5 COUNTERS / TIME PROG / CLOCK menus / PROG COOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
6.2 Setting the parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
6.2.1 Modifying the User parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
6.2.2 Activating Forcing of the cooling function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Contents
7611444 - v02 - 11122015 3
6.2.3 Setting the room temperature set point in comfort mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
6.2.4 Setting the domestic hot water temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
6.2.5 Activating Manual Forcing for heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
6.2.6 Setting the timer program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
7 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
7.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
7.1.1 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
7.2 Standard inspection and maintenance operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
7.2.1 Checking the water pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
7.3 Cleaning the casing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
7.4 Venting the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
8 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
8.1 Error codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
8.1.1 Error codes on the PCB EHC-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
8.1.2 Error codes on the second circuit PCB (SCB-04 PCB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
8.1.3 Blocking of the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
8.1.4 Locking of the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
8.2 Error history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
8.3 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
9 Decommissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
9.1 Decommissioning procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
10 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
10.1 Disposal and Recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
11 Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
11.1 Energy savings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
12 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
12.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
12.2 Terms of warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
13 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
13.1 Product fiche . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
13.2 Package fiche . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Contents
4 7611444 - v02 - 11122015
1 Safety
1.1 General safety instructions
Danger This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Danger In the event of a refrigerant leakage:
1. Switch off the appliance.
2. Open the windows.
3. Do not use a naked flame, do not smoke, do not operate electrical contacts.
4. Avoid contact with the refrigerant. Danger of frost injuries.
5. Evacuate the property.
6. Contact a qualified professional.
Danger If you smell gas:
1. Do not use naked flames, do not smoke and do not operate electrical contacts or switches (door bell, lighting, motor, lift etc.).
2. Shut off the gas supply.
3. Open the windows.
4. Evacuate the property.
5. Contact a qualified installer.
Danger If you smell flue gases:
1. Switch the boiler off.
2. Open the windows.
3. Evacuate the property.
4. Contact a qualified installer.
Danger of electric shock Before any work, switch off the mains supply to the heat pump.
Caution Installation of the heat pump must be done by a quali fied professional in accordance with prevailing local and national regulations.
1 Safety
7611444 - v02 - 11122015 5
Warning Do not touch the refrigeration connection pipes with your bare hands while the heat pump is running. Dan ger of burn or frost injury.
Warning Do not touch the radiators for long periods. Depending on the heat pump settings, the temperature of the ra diators may exceed 60°C.
Warning Do not touch the flue gas pipes. Depending on the boiler settings, the temperature of the flue gas pipes can rise to over 60°C.
Warning In order to limit the risk of being scalded, the installa tion of a thermostatic mixing valve on the domestic hot water flow pipes is obligatory. Take precautions with the domestic hot water. De pending on the heat pump settings, the domestic hot water temperature may exceed 65°C.
Note Respect the minimum and maximum water inlet pres sure to ensure correct operation of the heat pump: re fer to the chapter Technical Specifications.
Caution Only genuine spare parts may be used.
Warning Only qualified professionals are authorised to work on the heat pump and the heating system.
Note Insulate the pipes to reduce heat losses to a mini mum.
Caution Ensure that the boiler is regularly serviced. Contact a qualified installer or arrange a maintenance contract for the servicing of the boiler.
Warning Do not touch the flue gas pipes. Depending on the boiler settings, the temperature of the flue gas pipes can rise to over 60°C.
Note Regularly check for the presence of water and pres sure in the heating installation.
1 Safety
6 7611444 - v02 - 11122015
Caution The system must satisfy each point in the rules in force in the country that govern works and interven tions in individual homes, blocks of flats or other build ings.
Note Heating water and domestic water must not come into contact with each other.
Electrical connection
Caution
The heat pump must always be connected to the protective earthing. Earthing must comply with the prevailing installation standards. Earth the appliance before making any electrical
connections. For the type and calibre of the protective equipment: refer to the chapter Recommended Cable Cross-sec tions in the Installation and Service Manual.
Caution A disconnection method must be allowed in the fixed pipes in accordance with the rules on installation in force in the country.
Caution If a power cord comes with the appliance and it turns out to be damaged, it must be replaced by the manu facturer, its after sales service or persons with similar qualifications in order to obviate any danger.
Caution In order to prevent any danger owing to the unexpec ted reset of the thermal circuit breaker, this appliance must not be powered through an external switch, such as a timer, or be connected to a circuit which is regu larly switched on and off by the electricity provider.
Note This manual can also be found on our internet site.
1.2
Recommendations
Caution Install the hydraulic module and the boiler for the hy brid system in a location protected from freezing.
Caution If the home is unoccupied for a long period and there is a risk of frost, drain the hybrid system.
Note Keep the hybrid system accessible at all times.
1 Safety
7611444 - v02 - 11122015 7
Note Never remove or cover labels and data plates affixed to the appliances. Labels and data plates must be legible throughout the entire lifetime of the appliance. Immediately replace damaged or illegible instructions and warning stickers.
Note Remove the casing only to perform maintenance and repair work. Put the casing back in place after mainte nance and repair work.
Warning Only qualified persons are authorised to assemble, in stall and maintain the installation.
Warning The hybrid heat pump (heat pump and boiler) must be disassembled and disposed of by a qualified installer in accordance with local and national regulations.
Warning If the mains lead is damaged, it must be replaced by the original manufacturer, the manufacturer's dealer or another suitably skilled person to prevent hazard ous situations from arising.
Caution The hybrid system should be in Summer or Frost Pro tection mode rather than switched off to guarantee the following functions:
Anti blocking of pumps
Frost Protection
Note Regularly check the presence of water and pressure in the heating installation.
Note Keep this document close to the place where the ap pliance is installed.
Caution Do not make any modifications to the hybrid system without the written consent of the manufacturer.
Caution Do not neglect to service the hybrid system. Contact a qualified professional or take out a maintenance con tract for the annual servicing of the hybrid system.
1 Safety
8 7611444 - v02 - 11122015
1.3
Specific safety instructions
Warning Refrigerant fluid and pipes:
Use only R410A refrigerant fluid to fill the installa
tion.
Use tools and pipe components especially designed
for use with
R410A refrigerant fluid. Use copper pipes deoxidised with phosphorus to carry the refrigerant fluid. Store the refrigerant connection pipes away from dust and humidity (risk of damage to the compres sor). Do not use a load cylinder. Protect the heat pump components, including the in sulation and structural elements. Do not overheat the pipes as brazed components may cause dam age. Contact between the refrigerant fluid and a flame may result in emissions of toxic gases.
1.3.1 Refrigerant fluid R410A
Hazard identification Effects harmful to health:
The vapours are heavier than air and may lead to asphyxia owing to reduced oxygen levels. Liquefied gas: contact with the liquid may cause serious frost burn and eye injuries. Product classification: this product is not classified as a "hazardous preparation" according to European Union reg ulations.
If the R410A refrigerant is mixed with air, it may cause pres sure surges in the refrigeration pipes and lead to an explo sion and other hazards.
Composition of / Information on the ingredients Chemical nature: R-410A is composed of Difluoromethane R32 and Pentafluoroethane R125
Tab.1 Composition of R-410A fluid
Name
Proportion Number CE Number CAS
Difluoromethane R32 50% 200–839–4 75-10-5
Pentafluoroethane R125 50% 206-557-8 354-33-6
The Global-Warming Potential of R410A gas is 2087.5.
1 Safety
7611444 - v02 - 11122015 9
Tab.2 Precautions for use
First aid If inhaled:
Evacuate the subject from the contaminated area and take him into the open air. If feeling unwell: call a doctor.
In the event of contact with the skin:
Treat frost injuries like burns. Rinse with copious amounts of tepid water, do not remove clothing (risk of adhesion to the skin). If skin burns appear, call a doctor immediately.
In the event of contact with the eyes:
Rinse immediately with water, holding the eyelids well apart (for at least 15 minutes). Consult an ophthalmologist immediately.
Fire prevention meas ures
Appropriate extinguishing agents: All extinguishing agents can be used. Inappropriate extinguishing agents: none to our knowledge. In the event of fire nearby, use the appropriate extinguishing agents. Specific hazards:
Rise in pressure: in the presence of air, an inflammable mixture may form under certain temperature and pressure conditions.
Toxic and corrosive vapours may be released by the effect of the heat. Special intervention methods: cool the volumes exposed to heat with water spray. Protection of the firemen:
Full self-contained breathing apparatus.
Complete body protection.
In the event of acciden tal spillage
Individual precautions:
Avoid contact with the skin and eyes. Do not intervene without appropriate protective equipment. Do not inhale the vapours. Evacuate the hazardous area. Stop the leakage. Eradicate all sources of ignition. Ventilate the spillage area mechanically.
Cleaning / decontamination: allow any residual product to evaporate. In the event of contact with the eyes: Rinse immediately with water, holding the eyelids well apart (for at least 15 minutes). Consult an ophthalmologist immediately.
Handling
Technical measures: ventilation Precautions to be taken:
No smoking.
Prevent the build-up of electrostatic charges.
Work in a well ventilated place.
Personal protection Respiratory protection:
If ventilation is insufficient: AX type cartridge mask.
In confined spaces: self-contained breathing apparatus. Hand protection: protective gloves in leather or nitrile rubber. Eye protection: safety glasses with side protection. Skin protection: clothing made principally of cotton Industrial hygiene: do not drink, eat or smoke at the place of work.
1 Safety
10 7611444 - v02 - 11122015
Considerations on dis posal
Note Disposal must be done in compliance with prevailing local and national regulations.
Product waste: consult the manufacturer or the supplier for information on recovery or recycling. Soiled packaging: reuse or recycle after decontamination. Destroy in au thorised installations.
Regulation European Regulation No. EC 842/2006: fluorinated greenhouse gases un
der the Kyoto Protocol.
1.4
Liabilities
1.4.1 User's liability
To guarantee optimum operation of the system, you must abide by the following instructions:
Read and follow the instructions given in the manuals pro vided with the appliance. Call on a qualified professional to carry out installation and initial commissioning. Get your installer to explain your installation to you. Have the required inspections and maintenance carried out by a qualified installer. Keep the instruction manuals in good condition close to the appliance.
1.4.2
Installer's liability
The installer is responsible for the installation and initial com missioning of the appliance. The installer must abide by the following instructions:
Read and follow the instructions given in the manuals pro vided with the appliance. Install the appliance in compliance with prevailing legisla tion and standards. Carry out initial commissioning and any checks necessary. Explain the installation to the user. If maintenance is necessary, warn the user of the obliga tion to check the appliance and keep it in good working or der. Give all the instruction manuals to the user.
1.4.3 Manufacturer's liability
Our products are manufactured in compliance with the re quirements of the various Directives applicable. They are therefore delivered with the marking and any documents necessary. In the interests of the quality of our products, we strive constantly to improve them. We therefore reserve the right to modify the specifications given in this document.
Our liability as manufacturer may not be invoked in the fol lowing cases:
1 Safety
7611444 - v02 - 11122015 11
Failure to abide by the instructions on installing the appli ance. Failure to abide by the instructions on using the appliance. Faulty or insufficient maintenance of the appliance.
1 Safety
12 7611444 - v02 - 11122015
2 About this manual
2.1 General
This manual is intended for the user of a Alezio G hybrid hybrid heat pump.
2.2
Additional documentation
These instructions contain information on the indoor module for the hybrid heat pump (hydraulic module + boiler), and some information on the out door unit.
For additional information on the outdoor unit, refer to the manual provided with that unit.
2.3
Symbols used
2.3.1
Symbols used in the manual
This manual uses various danger levels to draw attention to special in structions. We do this to improve user safety, to prevent problems and to guarantee correct operation of the appliance.
Danger Risk of dangerous situations that may result in serious personal injury.
Danger of electric shock Risk of electric shock.
Warning Risk of dangerous situations that may result in minor personal in jury.
Caution Risk of material damage.
Note Please note: important information.
See Reference to other manuals or pages in this manual.
2.3.2 Symbols used on the appliance
1 Alternating current 2 Protective earthing
1 Before installing and commissioning the appliance, carefully read
the instruction manuals provided
2 Dispose of used products in an appropriate recovery and recycling
structure
Fig.1 Symbols used on the appliance
MW-6000066-3
1 2
Fig.2 Symbols used on the data plate
1
2
MW-6000691-1
2 About this manual
7611444 - v02 - 11122015 13
3 Technical specifications
3.1 Homologations
3.1.1 Directives
This product complies with the requirements of the following European Di rectives and Standards:
Low Voltage Directive 2006/95/EC Generic standard: EN 60335–1 Relevant Standard: EN 60335-2-40 Electromagnetic Compatibility Directive 2004/108/EC Generic standards: EN 61000-6-3, EN 61000-6-1 Relevant Standard: EN 55014 Pressure Equipment Directive 97/23/EC, Article 3, paragraph 3
This product conforms to the requirements of European Directive 2009/125/EC on the ecodesign of energy-related products.
In addition to the legal requirements and guidelines, the supplementary guidelines in this manual must also be followed.
Supplements or subsequent regulations and guidelines that are valid at the time of installation shall apply to all regulations and guidelines speci fied in this manual.
3.1.2 Certifications
Tab.3 Certifications
CE identification number PIN 0063CM3019
NOx class 5 (EN 15502–1)
Type of connection
3.1.3 Unit categories
Tab.4 Unit categories
Category Gas type Connection pressure
(mbar)
II
2H3B/P
G20 (H gas) G30/G31 (butane/propane)
20 30
3.1.4 Factory test
Before leaving the factory, each indoor module is tested on the following items:
Tightness of the heating circuit Electrical safety Tightness of the refrigerant circuit
3 Technical specifications
14 7611444 - v02 - 11122015
3.2 Technical data
3.2.1 Boiler specifications
Tab.5 General
Alezio G hybrid
Nominal output (Pn) Central heating operation (80°C/60°C)
min–max
(1)
kW
Nominal output (Pn) DHW operation
min-max
(1)
kW
(1) Factory setting
Tab.6 Details of gas and flue gas
Alezio G hybrid
Central heating chimney efficiency (Hi) (80/60°C) at 20°C amb.
%
Central heating chimney losses (Hi) (80/60°C) at 20°C amb.
%
Tab.7 Central heating circuit data
Alezio G hybrid
Water content l
Water operating pressure (PMS) max bar
Water temperature max °C
Operating temperature max °C
Tab.8 DHW circuit data
Alezio G hybrid
Specific hot water flow rate D (60°C) l/min
Specific hot water flow rate D (40°C) l/min
Flow rate threshold
(1)
min l/min
Operating pressure (Pmw) bar
(1) Minimum amount of water that comes out of the tap to make the boiler start.
Tab.9 Electrical data
Alezio G hybrid
Supply voltage VAC
Power consumption – full load
max
(1)
W
(1) Factory setting
Tab.10 Other data
Alezio G hybrid
Total weight (empty) kg
Average acoustic level
(1)
at a distance of one metre from the boiler
Central heating operation DHW operation
dB(A)
(1) Maximum.
3 Technical specifications
7611444 - v02 - 11122015 15
3.2.2 Heat pump
Maximum operating pressure: 0.3 MPa (3 bar)
Tab.11 Conditions of use
Water (°C) Outside air (°C)
Limit operating temperatures in heating mode
+18 / +60 AWHP 4 MR, AWHP 6 MR-2 : -15 / +35
Other models: -20 / +35
Limit operating temperatures in cooling mode
+7 / +25 +7 / +40
Tab.12 Heating mode: outside air temperature +7°C, water temperature at the outlet +35°C. Performances in accordance with
EN 14511-2.
Measurement type Unit AWHP 4 MR AWHP 6 MR-2 AWHP 8 MR-2
Heat output kW 3.94 5.79 7.90
Coefficient of perform ance (COP)
4.53 4.05 4.35
Absorbed electrical power
kWe 0.87 1.43 1.82
Nominal water flow rate (ΔT = 5K)
m3/hour
0.68 1.00 1.36
Tab.13 Heating mode: outside air temperature +2°C, water temperature at the outlet +35°C. Performances in accordance with
EN 14511-2.
Measurement type Unit AWHP 4 MR AWHP 6 MR-2 AWHP 8 MR-2
Heat output kW 3.89 3.65 6.80
Coefficient of perform ance (COP)
3.35 3.23 3.30
Absorbed electrical power
kWe 1.16 1.13 2.06
Tab.14 Cooling mode: outside air temperature +35°C, water temperature at the outlet +18°C. Performances in accordance with
EN 14511-2.
Measurement type Unit AWHP 4 MR AWHP 6 MR-2 AWHP 8 MR-2
Cooling output kW 3.84 4.69 7.90
Energy efficiency ratio (EER)
4.83 4.09 3.99
Absorbed electrical power
kWe 0.72 1.15 2.00
Tab.15 Common specifications
Measurement type Unit AWHP 4 MR AWHP 6 MR-2 AWHP 8 MR-2
Total dynamic head at nominal flow rate
kPa 67 63 44
Nominal air flow rate
m3/hour
2100 2100 3300
Power voltage of the outdoor unit
V 230 230 230
Start-up amperage A 5 5 5
Maximal amperage A 13 13 19
Acoustic power - In side
(1)
dB(A) 48.8 48.8 48.8
3 Technical specifications
16 7611444 - v02 - 11122015
Measurement type Unit AWHP 4 MR AWHP 6 MR-2 AWHP 8 MR-2
Acoustic power - Out side
(1)
dB(A) 62.4 64.8 66.7
Refrigerant fluid R410A
kg 2.1 2.1 3.2
Refrigerant connection (Liquid - Gas)
inch 1/4 - 1/2 1/4 - 1/2 3/8 - 5/8
Max. pre-loaded length m 10 10 10
International protection code (electrical)
IP X2D IP X2D IP X2D
(1) Noise radiated by the envelope - Test run in accordance with the NF EN 12102 standard, temperature conditions: air 7°C, water 55°C
3.2.3 Weight
Tab.16 Hydraulic module
Weight (empty) kg 22
Note For the weight of the boiler, refer to the Other Data table in the Boiler technical characteristics section.
Tab.17 Outdoor unit
Weight (empty) Unit AWHP 4 MR AWHP 6 MR-2 AWHP 8 MR-2
Outdoor unit kg 42 42 75
3.2.4 Technical data - Low-temperature heat pump combination heaters
Tab.18 Technical parameters for heat pump combination heaters (parameters declared for medium-temperature application)
Product name AWHP 4MR–
EMC 24/28 MI HYBRIDE
AWHP 6MR– EMC 24/28 MI HYBRIDE
AWHP 8MR– EMC 24/28 MI HYBRIDE
Air-to-water heat pump Yes Yes Yes
Water-to-water heat pump No No No
Brine-to-water heat pump No No No
Low-temperature heat pump No No No
Equipped with a supplementary heater Yes Yes Yes
Heat pump combination heater Yes Yes Yes
Rated heat output under average conditions
(1)
Prated
kW 6 8 11
Rated heat output under colder conditions
(1)
Prated
kW 5 6 9
Rated heat output under warmer conditions
(1)
Prated
kW 3 5 6
Declared capacity for heating for part load at in door temperature 20 °C and outdoor temperature
T
j
T
j
= -7 °C
Pdh
kW 2.9 3.5 5.6
T
j
= +2 °C
Pdh
kW 3.5 4.5 6.1
T
j
= +7 °C
Pdh
kW 3.9 4.8 6.4
T
j
= +12 °C
Pdh
kW 4.8 5.2 6.5
T
j
= bivalent temperature
Pdh
kW 3.5 4.5 6.1
3 Technical specifications
7611444 - v02 - 11122015 17
Product name AWHP 4MR–
EMC 24/28 MI HYBRIDE
AWHP 6MR– EMC 24/28 MI HYBRIDE
AWHP 8MR– EMC 24/28 MI HYBRIDE
T
j
= operation limit temperature
Pdh
kW 2.8 3.6 5.6
Bivalent temperature
T
biv
°C 2 2 2
Degradation co-efficient
(2)
Cdh
1.0 1.0 1.0
Seasonal space heating energy efficiency under average conditions
ƞ
s
% 150 133 135
Seasonal space heating energy efficiency under colder conditions
ƞ
s
% 132 122 125
Seasonal space heating energy efficiency under warmer conditions
ƞ
s
% 195 166 169
Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature
T
j
T
j
= -7 °C
COPd
­or %
1.82 1.86 1.95
T
j
= +2 °C
COPd
­or %
3.88 3.40 3.49
T
j
= +7 °C
COPd
­or %
5.65 4.52 4.57
T
j
= +12 °C
COPd
­or %
9.33 6.70 6.33
T
j
= bivalent temperature
COPd
­or %
3.88 3.40 3.49
T
j
= operation limit temperature
COPd
­or %
1.47 1.52 1.63
Operation limit temperature for air-to-water heat pumps
TOL
°C -10 -10 -10
Heating water operating limit temperature
WTOL
°C 80 80 80
Electrical power consumption
Off mode
P
OFF
kW 0.009 0.009 0.009
Thermostat-off mode
P
TO
kW 0.049 0.049 0.049
Stand-by
P
SB
kW 0.013 0.013 0.013
Crankcase heater mode
P
CK
kW 0.055 0.055 0.055
Supplementary heater
Rated heat output
(1)
Psup
kW 3.7 4.8 5.8
Type of energy input Gas Gas Gas
Other characteristics
Capacity control Variable Variable Variable
Sound power level, indoors - outdoors
L
WA
dB 42 – 62 42 – 64 42 – 65
Annual energy consumption under average conditions
Q
HE
kWh GJ
2900
5
4312
7
5859
8
Annual energy consumption under colder con ditions
Q
HE
kWh GJ
3230
3
4236
3
6548
5
Annual energy consumption under warmer conditions
Q
HE
kWh GJ
887
0
1544
0
1904
0
3 Technical specifications
18 7611444 - v02 - 11122015
Loading...