DeDietrich AWHP 16 MR-2, AWHP 8 MR-2, AWHP 6 MR-2, AWHP 16 TR-2, AWHP 4 MR User Manual

...
MW-8200019-1
MW-8200019-1
Ireland
en
User Manual
Reversible air / water "Split Inverter" heat pump
MIV-4/E 4–8 V200
MIV-4/E 11–16 V200
MIV-4/H 4–8 V200
MIV-4/H 11–16 V200
Dear customer,
Thank you for purchasing this appliance.
Please read this manual carefully before using the product and keep it in a safe place for future reference.
In order to ensure continued safe and efficient operation we recommend that the product is regularly maintained. Our Service and After Sales organization can assist with this.
We hope you will receive many years of satisfactory service.
Contents
1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.3 Specific safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.3.1 Refrigerant fluid R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.4 Liabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.4.1 Manufacturer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.4.2 Installer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
1.4.3 User's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2 About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.2 Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.2.1 Symbols used in the manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.2.2 Symbols used on the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
3 Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.1 Homologations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.1.1 Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
3.2 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
3.2.1 Heat pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.2.2 Domestic hot water tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.2.3 Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.2.4 Combination heaters with medium-temperature heat pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.2.5 Circulating pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4 Description of the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.1 General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
4.2 Operating principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.3 Main components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4.4 Control panel description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.4.1 Description of the keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.4.2 Description of the display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
5.1 Use of the control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5.1.1 Browsing in the menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5.1.2 Accessing the User menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5.1.3 Accessing the Hour Run Meters / Timer Program / Clock sub-menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
5.2 Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
5.3 Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5.3.1 Switching off the heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5.3.2 Stopping domestic hot water production . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
5.3.3 Shutting down the cooling function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
5.4 Frost Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
6 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6.1 List of parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6.1.1 Menu List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6.1.2 Information Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
6.1.3 User menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6.1.4 PCB parameters for the PCB + sensor kit for circuits with mixing valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
6.1.5 COUNTERS / TIME PROG / menus CLOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
6.2 Setting the parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6.2.1 Modifying the User parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6.2.2 Activating the cooling function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6.2.3 Setting the heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
6.2.4 Setting the domestic hot water temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
6.2.5 Activating Manual Forcing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
6.2.6 Setting the timer program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
7 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Contents
7623755 - v02 - 03072015 MIV-4 3
7.1 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
7.2 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
7.3 Standard inspection and maintenance operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
7.4 Cleaning the casing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
8 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
8.1 Error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
8.1.1 Error codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
8.1.2 PCB error codes on the PCB + sensor kit for circuits with mixing valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
8.2 Error history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
8.3 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
9 Decommissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
9.1 Decommissioning procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
10 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
10.1 Disposal and Recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
11 Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
11.1 Energy savings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
12 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
12.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
12.2 Terms of warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
13 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
13.1 Product data sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
13.2 Product data sheet - Temperature controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
13.3 Package fiche . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
13.4 Package fiche - Combination heaters (boilers or heat pumps) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Contents
4 MIV-4 7623755 - v02 - 03072015
1 Safety
1.1 General safety instructions
Danger This appliance can be used by children aged 8 years and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge when they have been given supervi sion or instruction concerning the safe use of the de vice and understand the resulting risks. Children must not be allowed to play with the appliance. Cleaning and user maintenance must not be carried out by chil dren without supervision.
Danger of electric shock Before any work, switch off all electricity supplies.
Caution Installation of the heat pump must be done by a quali fied professional in accordance with prevailing local and national regulations.
Warning Do not touch the refrigeration connection pipes with your bare hands while the heat pump is running. Dan ger of burn or frost injury.
Warning Do not touch the radiators for long periods. Depending on the heat pump settings, the temperature of the ra diators may exceed 60°C.
Warning In order to limit the risk of being scalded, the installa tion of a thermostatic mixing valve on the domestic hot water flow pipes is obligatory. Take precautions with the domestic hot water. De pending on the heat pump settings, the domestic hot water temperature may exceed 65°C.
Caution Only genuine spare parts may be used.
Warning Only qualified professionals are authorised to work on the domestic hot water tank and the heating installa tion.
Note Insulate the pipes to reduce heat losses to the mini mum.
1 Safety
7623755 - v02 - 03072015 MIV-4 5
Caution The system must satisfy each point in the rules in force in the country that govern works and interven tions in individual homes, blocks of flats or other build ings.
Note Heating water and domestic water must not come into contact with each other.
Note Allow the space required to install the appliance cor rectly: refer to the chapter Dimensions of the Appli ance (Installation and Service Manual).
Caution
Refrigerant safety
Danger In the event of a refrigerant leakage:
1. Switch off the appliance.
2. Open the windows.
3. Do not use a naked flame, do not smoke, do not operate electrical contacts.
4. Avoid contact with the refrigerant. Danger of frost injuries.
5. Evacuate the property.
6. Contact a qualified professional.
Hydraulic safety
Caution The appliance is intended to be permanently connec ted to the domestic water mains network.
Caution Respect the minimum and maximum water inlet pres sure to ensure correct operation of the appliance: re fer to the chapter Technical Specifications.
Caution Draining the appliance:
1. Shut off the domestic cold water inlet.
2. Open a hot water tap in the installation.
3. Open a valve on the safety unit.
4. When the water stops flowing, the appliance has been drained.
Note For the domestic hot water operating temperature lim its: refer to the chapter Technical Data, Domestic Hot Water Tank.
1 Safety
6 MIV-4 7623755 - v02 - 03072015
Note Setting the domestic hot water temperature set point: refer to the chapter "Setting the domestic hot water temperature set point".
Caution Pressure limiter device: refer to the chapter Special precautions to be taken when connecting the domes tic hot water circuit (Installation and Service Manual).
The pressure limiter device (safety valve or safety unit) must be regularly operated in order to remove limescale deposits and ensure that it is not blocked. A pressure limiter device must be fitted to a dis charge pipe. As water may flow out of the discharge pipe, the pipe must be kept open to the open air, in a frost­free environment, and at a continuous downward gradient.
Caution A pressure reducer (not provided) is required when the supply pressure exceeds 80% of the safety valve or safety unit calibration and must be located up stream of the appliance.
Caution There must be no cut-off devices between the safety valve or unit and the domestic hot water tank.
Electrical safety
Caution A disconnection device must be fitted to the perma nent pipes in accordance with installation rules.
Caution If a power cord comes with the appliance and it turns out to be damaged, it must be replaced by the manu facturer, its after sales service or persons with similar qualifications in order to obviate any danger.
Caution Install the appliance in accordance with national rules on electrical installation.
Caution If the appliance is not wired in the factory, carry out the wiring according to the wiring schematics descri bed in the chapter Electrical Connections (Installation and Service Manual).
1 Safety
7623755 - v02 - 03072015 MIV-4 7
Caution This appliance must be connected to the protective earth. Earthing must comply with prevailing installation standards. Earth the appliance before making any electrical con nections. Type and calibre of the protective equipment: refer to the chapter Recommended cable cross-sections (In stallation and Service Manual).
Caution To connect the appliance to the mains electricity, refer to the chapter Electrical Connections (Installation and Service Manual).
Caution This appliance must not be powered through an exter nal switch, such as a timer, or be connected to a cir cuit which is regularly switched on and off by the elec tricity provider.
Note The Installation Manual for the appliance is also avail able on our internet site.
1.2
Recommendations
Caution Install the heat pump's indoor module in a frost-free location.
Caution To enjoy warranty cover, no modifications must be made to the appliance.
Note Only qualified persons are authorised to assemble, in stall and maintain the installation.
Caution Maintenance work must be carried out by a qualified professional.
Caution After maintenance or repair work, check the entire heating installation to ensure that there are no leaks.
Caution Only qualified professionals may carry out electrical connections, always with the power off.
Caution Separate the very low voltage cables from the 230/400 V circuit cables.
1 Safety
8 MIV-4 7623755 - v02 - 03072015
Note The frost protection function does not work if the heat pump is switched off.
Caution If the home is unoccupied for a long period and there is a risk of frost, drain the indoor module and the heat ing system.
Note Keep the heat pump accessible at all times.
Note Never remove or cover labels and data plates affixed to the appliances. Labels and data plates must be legible throughout the entire lifetime of the appliance. Immediately replace damaged or illegible instructions and warning stickers.
Note Remove the casing only to perform maintenance and repair work. Put the casing back in place after mainte nance and repair work.
Caution Give preference to the or mode rather than switching off the system to leave the following func tions running:
Anti blocking of pumps Frost Protection
Note Regularly check the presence of water and pressure in the heating installation.
Note Keep this document close to the place where the ap pliance is installed.
Caution Do not make any modifications to the heat pump with out the written consent of the manufacturer.
Caution Do not neglect to service the heat pump. Contact a qualified professional or subscribe to a maintenance contract for the annual servicing of the heat pump.
1 Safety
7623755 - v02 - 03072015 MIV-4 9
1.3
Specific safety instructions
Warning Refrigerant fluid and pipes:
Use only R410A refrigerant fluid to fill the installa tion. Use tools and pipe components especially designed for use with
R410A refrigerant fluid. Use copper pipes deoxidised with phosphorus to carry the refrigerant fluid. Store the refrigerant connection pipes away from dust and humidity (risk of damage to the compres sor). Do not use a load cylinder. Protect the heat pump components, including the in sulation and structural elements. Do not overheat the pipes as brazed components may cause dam age. Contact between the refrigerant fluid and a flame may result in emissions of toxic gases.
1.3.1 Refrigerant fluid R410A
Hazard identification Effects harmful to health:
The vapours are heavier than air and may lead to asphyxia owing to reduced oxygen levels. Liquefied gas: contact with the liquid may cause serious frost burn and eye injuries. Product classification: this product is not classified as a "hazardous preparation" according to European Union reg ulations.
If the R410A refrigerant is mixed with air, it may cause pres sure surges in the refrigeration pipes and lead to an explo sion and other hazards.
Composition of / Information on the ingredients Chemical nature: R-410A is composed of Difluoromethane R32 and Pentafluoroethane R125
Tab.1 Composition of R-410A fluid
Name
Proportion Number CE Number CAS
Difluoromethane R32 50% 200–839–4 75-10-5
Pentafluoroethane R125 50% 206-557-8 354-33-6
The Global-Warming Potential of R410A gas is 2087.5.
1 Safety
10 MIV-4 7623755 - v02 - 03072015
Tab.2 Precautions for use
First aid If inhaled:
Evacuate the subject from the contaminated area and take him into the open air. If feeling unwell: call a doctor.
In the event of contact with the skin:
Treat frost injuries like burns. Rinse with copious amounts of tepid water, do not remove clothing (risk of adhesion to the skin). If skin burns appear, call a doctor immediately.
In the event of contact with the eyes:
Rinse immediately with water, holding the eyelids well apart (for at least 15 minutes). Consult an ophthalmologist immediately.
Fire prevention meas ures
Appropriate extinguishing agents: All extinguishing agents can be used. Inappropriate extinguishing agents: none to our knowledge. In the event of fire nearby, use the appropriate extinguishing agents. Specific hazards:
Rise in pressure: in the presence of air, an inflammable mixture may form under certain temperature and pressure conditions.
Toxic and corrosive vapours may be released by the effect of the heat. Special intervention methods: cool the volumes exposed to heat with water spray. Protection of the firemen:
Full self-contained breathing apparatus.
Complete body protection.
In the event of acciden tal spillage
Individual precautions:
Avoid contact with the skin and eyes. Do not intervene without appropriate protective equipment. Do not inhale the vapours. Evacuate the hazardous area. Stop the leakage. Eradicate all sources of ignition. Ventilate the spillage area mechanically.
Cleaning / decontamination: allow any residual product to evaporate. In the event of contact with the eyes: Rinse immediately with water, holding the eyelids well apart (for at least 15 minutes). Consult an ophthalmologist immediately.
Handling
Technical measures: ventilation Precautions to be taken:
No smoking.
Prevent the build-up of electrostatic charges.
Work in a well ventilated place.
Personal protection Respiratory protection:
If ventilation is insufficient: AX type cartridge mask.
In confined spaces: self-contained breathing apparatus. Hand protection: protective gloves in leather or nitrile rubber. Eye protection: safety glasses with side protection. Skin protection: clothing made principally of cotton Industrial hygiene: do not drink, eat or smoke at the place of work.
1 Safety
7623755 - v02 - 03072015 MIV-4 11
Considerations on dis posal
Note Disposal must be done in compliance with prevailing local and national regulations.
Product waste: consult the manufacturer or the supplier for information on recovery or recycling. Soiled packaging: reuse or recycle after decontamination. Destroy in au thorised installations.
Regulation European Regulation No. EC 842/2006: fluorinated greenhouse gases un
der the Kyoto Protocol.
1.4
Liabilities
1.4.1 Manufacturer's liability
Our products are manufactured in compliance with the re quirements of the various Directives applicable. They are therefore delivered with the marking and any documents necessary. In the interests of the quality of our products, we strive constantly to improve them. We therefore reserve the right to modify the specifications given in this document.
Our liability as manufacturer may not be invoked in the fol lowing cases:
Failure to abide by the instructions on installing the appli ance. Failure to abide by the instructions on using the appliance. Faulty or insufficient maintenance of the appliance.
1.4.2 Installer's liability
The installer is responsible for the installation and initial com missioning of the appliance. The installer must abide by the following instructions:
Read and follow the instructions given in the manuals pro vided with the appliance. Install the appliance in compliance with prevailing legisla tion and standards. Carry out initial commissioning and any checks necessary. Explain the installation to the user. If maintenance is necessary, warn the user of the obliga tion to check the appliance and keep it in good working or der. Give all the instruction manuals to the user.
1.4.3 User's liability
To guarantee optimum operation of the system, you must abide by the following instructions:
Read and follow the instructions given in the manuals pro vided with the appliance. Call on a qualified professional to carry out installation and initial commissioning. Get your installer to explain your installation to you.
1 Safety
12 MIV-4 7623755 - v02 - 03072015
Have the required inspections and maintenance carried out by a qualified installer. Keep the instruction manuals in good condition close to the appliance.
1 Safety
7623755 - v02 - 03072015 MIV-4 13
2 About this manual
2.1 General
This manual is intended for the user of a MIV-4 heat pump. This manual can also be found on our internet site.
2.2
Symbols used
2.2.1 Symbols used in the manual
This manual uses various danger levels to draw attention to special in structions. We do this to improve user safety, to prevent problems and to guarantee correct operation of the appliance.
Danger Risk of dangerous situations that may result in serious personal injury.
Danger of electric shock Risk of electric shock.
Warning Risk of dangerous situations that may result in minor personal in jury.
Caution Risk of material damage.
Note Please note: important information.
See Reference to other manuals or pages in this manual.
2.2.2 Symbols used on the appliance
1 Alternating current 2 Protective earthing
1 Information on the heat pump: type of refrigerant fluid, maximum
operating pressure and output absorbed by the indoor module
2 Information on the domestic hot water tank: volume, maximum op
erating pressure and standby losses of the domestic hot water tank
3 Information on the electrical back-up: power supply and maximum
output (only for versions with electrical back-up)
4 Before installing and commissioning the appliance, carefully read
the instruction manuals provided
5 Dispose of used products in an appropriate recovery and recycling
structure
Fig.1 Symbols used on the appliance
MW-6000066-3
1 2
Fig.2 Symbols used on the data plate
1
2
4 5
3
MW-6000286-1
2 About this manual
14 MIV-4 7623755 - v02 - 03072015
1 Sensor cable - low voltage 2 Power cord 230 V 3 Heating circuit flow 4 Circuit B flow 5 Heating circuit return 6 Circuit B return (optional) 7 Connection for recirculation 8 Domestic hot water outlet 9 Flow to boiler back-up (only for versions with hydraulic back-up)
10 Return from boiler back-up (only for versions with hydraulic back-
up) 11 Domestic cold water inlet 12 Drain valve 13 Safety valve 14
3
/8" refrigerant fluid connection - liquid line
15
5
/8" refrigerant fluid connection - gas line
Fig.3 Symbols used on the connection la
bel
G3/4"
A
G1"
A
G1"

B
G1"
B
G1"
G3/4"
G3/4"
5/8 69-82 Nm
3/8 34-42 Nm
Ø13
1
2
4
6
8
10
12
3
5
7
9
11
13
MW-6000285-1
14
15
2 About this manual
7623755 - v02 - 03072015 MIV-4 15
3 Technical specifications
3.1 Homologations
3.1.1 Directives
This product complies with the requirements of the following European Di rectives and Standards:
Low Voltage Directive 2006/95/EC Generic standard: IEC/EN 60335–1 Relevant Standard: IEC/EN 60335–2–40 Electromagnetic Compatibility Directive 2004/108/EC Generic standards: IEC/EN 61000-6-3, IEC/EN 61000-6-1 Relevant Standard: IEC/EN 55014
This product conforms to the requirements of European Directive 2009/125/EC on the ecodesign of energy-related products.
In addition to the legal requirements and guidelines, the supplementary guidelines in this manual must also be followed. Supplements or subse quent regulations and guidelines that are valid at the time of installation shall apply to all regulations and guidelines specified in this manual.
3.2 Technical data
3.2.1 Heat pump
Maximum operating pressure: 0.3 MPa (3 bar)
Tab.3 Conditions of use
Water (°C) Outside air (°C)
Limit operating temperatures in heating mode
+18 / +60 AWHP 4 MR, AWHP 6 MR-2 : -15 / +35
Other models: -20 / +35
Limit operating temperatures in cooling mode
+7 / +25 +7 / +40
Tab.4 Heating mode: outside air temperature +7°C, water temperature at the outlet +35°C. Performances in accordance with
EN 14511-2.
Measure ment type
Unit AWHP 4 MRAWHP 6
MR-2
AWHP 8 MR-2
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Heat output kW 3.94 5.73 8.26 11.39 11.39 14.65 14.65
Coefficient of perform ance (COP)
4.53 4.04 4.27 4.65 4.65 4.22 4.22
Absorbed electrical power
kWe 0.87 1.42 1.93 2.45 2.45 3.47 3.47
Nominal amperage
A 4.11 6.57 8.99 11.41 3.8 16.17 5.39
Nominal wa ter flow rate (ΔT = 5K)
m3/hour
0.68 0.99 1.42 1.96 1.96 2.53 2.53
Tab.5 Heating mode: outside air temperature +2°C, water temperature at the outlet +35°C. Performances in accordance with
EN 14511-2.
Measure ment type
Unit AWHP 4 MRAWHP 6
MR-2
AWHP 8 MR-2
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Heat output kW 3.76 3.19 5.30 10.19 10.19 12.90 12.90
3 Technical specifications
16 MIV-4 7623755 - v02 - 03072015
Measure ment type
Unit AWHP 4 MRAWHP 6
MR-2
AWHP 8 MR-2
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Coefficient of perform ance (COP)
3.32 2.97 3.46 3.20 3.20 3.27 3.27
Absorbed electrical power
kWe 1.13 1.08 1.53 3.19 3.19 3.94 3.94
Tab.6 Cooling mode: outside air temperature +35°C, water temperature at the outlet +18°C. Performances in accordance with
EN 14511-2.
Measure ment type
Unit AWHP 4 MRAWHP 6
MR-2
AWHP 8 MR-2
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Cooling out put
kW 3.84 4.69 7.90 11.16 11.16 14.46 14.46
Energy effi ciency ratio (EER)
4.83 4.09 3.99 4.75 4.75 3.96 3.96
Absorbed electrical power
kWe 0.72 1.15 2.00 2.35 2.35 3.65 3.65
Nominal amperage
A 3.40 5.43 9.40 11.05 3.68 17.15 5.71
Tab.7 Common specifications
Measure ment type
Unit AWHP 4 MRAWHP 6
MR-2
AWHP 8 MR-2
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Total dy namic head at nominal flow rate
kPa 58 49 29 11 11 35 35
Nominal air flow rate
m3/hour
2100 2100 3300 6000 6000 6000 6000
Power volt age of the outdoor unit
V 230 230 230 230 400 230 400
Start-up amperage
A 5 5 5 5 3 6 3
Maximal amperage
A 13 13 19 29.5 13 29.5 13
Acoustic power - In side
(1)
dB(A) 52.9 52.9 53.3 53.3 53.3 53.3 53.3
Acoustic power ­Outside
(1)
dB(A) 62.4 64.8 65.2 68.8 68.8 68.5 68.5
Acoustic pressure
(2)
dB(A) 41.7 41.7 43.2 43.4 43.4 47.4 47.4
Refrigerant fluid R410A
kg 2.1 2.1 3.2 4.6 4.6 4.6 4.6
Refrigera tion connec tion (Liquid/ Gas)
inch 1/4 - 1/2 1/4 - 1/2 3/8 – 5/8 3/8 – 5/8 3/8 – 5/8 3/8 – 5/8 3/8 – 5/8
3 Technical specifications
7623755 - v02 - 03072015 MIV-4 17
Measure ment type
Unit AWHP 4 MRAWHP 6
MR-2
AWHP 8 MR-2
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Max. pre­loaded length
m 10 10 10 10 10 10 10
(1) Noise radiated by the envelope - Test run in accordance with the NF EN 12102 standard, temperature conditions: air 7°C, water 55°C (2) at 5 m from the appliance, free field
3.2.2 Domestic hot water tank
Tab.8 Technical specifications primary circuit (heating water)
Specification Unit Value
Maximum operating temperature - Version with hydraulic back-up °C 90
Maximum operating temperature - Version with electrical back-up °C 75
Minimum operating temperature °C 7
Maximum operating pressure MPa (bar) 0.3 (3.0)
Exchanger capacity Litres 11.3
Exchange surface 1.7
Tab.9 Technical specifications secondary circuit (domestic water)
Specification Unit Value
Maximum operating temperature °C 80
Minimum operating temperature °C 10
Maximum operating pressure MPa (bar) 1.0 (10.0)
Water capacity Litres 177
Tab.10 Common specifications
AWHP/AWHP-V220 AWHP 4 MR AWHP 6 MR-2 AWHP 8 MR-2 AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2 AWHP 16 TR-2
Loading time
(1)
1 hour 54 minutes 1 hour 41 minutes 2 hours 11 minutes 1 hour 33 minutes 1 hour 11 minutes
Coefficient of per formance domestic hot water (COP
DHW
)
(2)
2.45 2.29 2.47 2.34 2.27
(1) ΔT = 55 K. Outside temperature: 7°C. Inside air temperature: 20°C (2) According to the standard EN16147
3.2.3
Weight
Tab.11 Indoor module
Weight (empty) Unit MIV-4/E 4–8 V200 MIV-4/E 11–16
V200
MIV-4/H 4–8 V200 MIV-4/H 11–16
V200
Indoor module kg 131 133 128 130
Tab.12 Outside unit
Weight (empty)
Unit AWHP 4 MRAWHP 6
MR-2
AWHP 8 MR-2
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Outside unit kg 42 42 75 118 130 118 130
3 Technical specifications