Contents
1 Safety instructions .....................................................................................4
1.1 General safety instructions .................................4
1.2 Recommendations ................................................6
1.3 Specific safety instructions .................................7
1.3.1 Safety data sheet: R-410A refrigerant .....................7
1.4 Liabilities .............................................................10
1.4.1 Manufacturer’s liability ...........................................10
1.4.2 Installer’s liability ...................................................10
1.4.3 User’s liability ........................................................11
2 About this manual ....................................................................................12
2.1 General ................................................................12
2.2 Symbols used .....................................................12
2.2.1 Symbols used in the manual .................................12
2.2.2 Symbols used on the equipment ...........................12
2.3 Abbreviations ......................................................13
3 Technical specifications ..........................................................................14
3.1 Homologations ....................................................14
3.1.1 Certifications .........................................................14
3.2 Technical specifications ....................................14
3.2.1 Electricity supply ...................................................14
3.2.2 Heat pump .............................................................14
3.2.3 Sensor characteristics ...........................................16
4 Description ................................................................................................17
4.1 General description ............................................17
4.2 Control panel .......................................................17
4.2.1 Description of the keys ..........................................17
4.2.2 Description of the display ......................................18
4.2.3 Browsing in the menus ..........................................21
1
10/06/2015 - 7616372-001-05
5 Operating the appliance ..........................................................................23
5.1 Putting the appliance into operation ................23
5.2 Reading out measured values ...........................24
5.3 Changing the settings ........................................25
5.3.1 Setting the set point temperatures ........................25
5.3.2 Selecting the operating mode ...............................26
5.3.3 Forcing domestic hot water production .................27
5.3.4 Setting the contrast and lighting on the
display ...................................................................27
5.3.5 Setting the time and date ......................................28
5.3.6 Selecting a timer programme ................................28
5.3.7 Customising a timer programme ...........................29
5.4 Installation shutdown .........................................31
5.5 Turning on the antifreeze function ....................31
6 Troubleshooting .......................................................................................32
6.1 Anti-hunting ........................................................32
6.2 Messages .............................................................32
6.3 Faults (Code type Lxx or Dxx) ...........................34
7 Energy savings .........................................................................................37
7.1 Energy savings ...................................................37
7.1.1 Energy-saving advice ............................................37
7.1.2 Room thermostat and settings ..............................37
7.2 Recommendations ..............................................37
8 Warranty ....................................................................................................39
8.1 General ................................................................39
8.2 Warranty terms ...................................................39
9 Appendix - Information on the Ecodesign and Energy Labelling
Directives ..................................................................................................40
Contents
2
10/06/2015 - 7616372-001-05
3
10/06/2015 - 7616372-001-05
1 Safety instructions
1.1 General safety instructions
DANGER
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
DANGER
If smoke is released or in case of refrigerant leak:
1. Do not use a naked flame, do not smoke, do not operate electrical contacts or switches ( doorbell, light, motor, lift, etc..). Contact between refrigerant and a flame may result in emissions of toxic gases.
2. Open the windows.
3. Trace possible leaks and seal them immediately.
WARNING
Before any work, switch off the mains supply to the appliance.
WARNING
Do not touch the refrigeration connection pipes with your bare hands while the appliance is running. Danger of burns or frost injury.
AWHP-2 MIT-IN-2 iSystem 1. Safety instructions
10/06/2015 - 7616372-001-05
4
WARNING
Take precautions when dealing with domestic hot water.Depending on the settings of the heat pump, the domestic hot water temperature may exceed 65°C.
CAUTION
Use only original spare parts.
WARNING
Only qualified professionals are authorised to work on the appliance and the installation.
Insulate the pipes to reduce heat losses to a minimum.
WARNING
The installation must comply in all matters to the standards and rules which govern the work and interventions in individual and collective homes, and other constructions.
CAUTION
The heating water and the water in the domestic circuit must never come into contact with each other.
Electrical connection
4 Allowance must be made for a means of disconnection
in the fixed pipes in accordance with the regulations on installations.
4 Always have the power cord replaced by a qualified
installer if it is damaged.
1. Safety instructions
AWHP-2 MIT-IN-2 iSystem
5
10/06/2015 - 7616372-001-05
WARNING
In order to prevent any danger caused by an unplanned reset of the thermal circuit breaker, this appliance must not be powered through an external switch, such as a timer, or be connected to a circuit which is regularly switched on and off by the electricity supplier.
WARNING
Depending on the settings of the appliance:
4 The temperature of the radiators may reach
80°C.
4 Do not touch the refrigeration connection
pipes with your bare hands while the appliance is running. Danger of burns or frost injury.
CAUTION
Do not neglect to service the appliance. Contact a qualified professional or take out a maintenance contract for the annual servicing of the appliance.
1.2 Recommendations
WARNING
Only qualified professionals are authorised to work on the appliance and the installation.
4 Regularly check that the water pressure in the
installation is between 1,5 and 2 bar.
4 Ensure that the appliance is accessible at all times for
maintenance purposes.
4 Avoid draining the installation. 4 Use only original spare parts. 4 Never remove or cover labels and rating plates affixed
to the appliance. Labels and rating plates must be legible throughout the entire lifetime of the appliance.
AWHP-2 MIT-IN-2 iSystem
1. Safety instructions
10/06/2015 - 7616372-001-05
6
1.3 Specific safety instructions
1.3.1. Safety data sheet: R-410A refrigerant
n
Product identification
4 Refrigerant name: R-410A
n
Hazard identification
4 Effects harmful to health:
- The vapours are heavier than air and may lead to asphyxia owing to reduced oxygen levels.
- Liquefied gas: Contact with the liquid may cause serious frost and eye injuries.
4 Product classification: This product is not classified as
a "hazardous preparation" according to European Union regulations.
CAUTION
If refrigerant is mixed with air, it may lead to pressure surges in the refrigeration pipes and cause an explosion and other hazards.
n
Composition / Information on the ingredients
4 Chemical nature: Mixture of R-32 and R-125. 4 Ingredients that may lead to hazardous situations:
Substance name
Concentration CAS number CE number Classification Global warming potential
1,1-Difluorométhane R-32 50% 75-10-5 200-839-4 F+ ; R12 650
Pentafluoroethane R-125 50% 354-33-6 206-557-8
3400
R-410A
2087,5
n
First aid
4 If inhaled: Evacuate the subject from the contaminated
area and take him into the open air. If feeling unwell: Call a doctor.
1. Safety instructions
AWHP-2 MIT-IN-2 iSystem
7
10/06/2015 - 7616372-001-05
4 In the event of contact with the skin: Treat frost
injuries as burns. Rinse in abundant water, do not remove clothing (risk of adhesion to the skin). If skin burns appear, call a doctor immediately.
4 In the event of contact with the eyes: Rinse
immediately in water, holding the eyelids well apart (at least 15 minutes). Consult an ophthalmologist immediately.
n
Fire prevention measures
4 Appropriate extinguishing agents:
- Carbon dioxide (CO2)
- Powders
- Foam
- Water spray.
4 Inappropriate extinguishing agents: None to our
knowledge. In the event of fire nearby, use the appropriate extinguishing agents.
4 Specific hazards:
- Toxic and corrosive vapours may be released by the effect of the heat.
- Elevated pressure: in the presence of air, an inflammable mixture may form under certain temperature and pressure conditions.
4 Special intervention methods: Cool the volumes
exposed to heat with water spray.
4 Protection of the firemen:
- Full facepiece self-contained breathing apparatus
- Complete body protection.
n
In the event of accidental spillage
4 Individual precautions:
- Avoid contact with the skin and eyes
- Do not intervene without appropriate protective
equipment
- Do not inhale the vapours
- Evacuate the hazardous area
- Stop the leakage
- Eradicate all sources of ignition
- Ventilate the spillage area mechanically (Risk of
asphyxia).
AWHP-2 MIT-IN-2 iSystem
1. Safety instructions
10/06/2015 - 7616372-001-05
8
4 Cleaning / Decontamination: Allow residual product to
evaporate.
n
Handling
4 Technical measures: Ventilation. 4 Precautions to be taken:
- No smoking
- Prevent the accumulation of electrostatic charges
- Work in a well ventilated place.
n
Personal protection
4 Respiratory protection:
- If insufficient ventilation: AX type cartridge mask
- In confined spaces: Full facepiece self-contained
breathing apparatus.
4 Hand protection: Protective gloves in leather or nitrile
rubber.
4 Eye protection: Safety glasses with side protection. 4 Skin protection: Clothing made mostly of cotton. 4 Industrial hygiene: Do not drink, eat or smoke at the
place of work.
n
Considerations on disposal
4 Product waste: Consult the manufacturer or the
supplier for information on recovery or recycling.
4 Soiled packaging: Reuse or recycle after
decontamination. Destroy in authorised installations.
WARNING
Disposal must be done in compliance with prevailing local and national regulations.
n
Regulations
4 EC Regulation 842/2006: Fluorinated greenhouse
gases under the Kyoto Protocol.
1. Safety instructions
AWHP-2 MIT-IN-2 iSystem
9
10/06/2015 - 7616372-001-05
1.4 Liabilities
1.4.1. Manufacturer’s liability
Our products are manufactured in compliance with the requirements of the various applicable European
Directives. They are therefore delivered with [ marking and all relevant documentation.
In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice.
Our liability as the manufacturer may not be invoked in the following cases:
4 Failure to abide by the instructions on using the
appliance.
4 Faulty or insufficient maintenance of the appliance. 4 Failure to abide by the instructions on installing the
appliance.
1.4.2. Installer’s liability
The installer is responsible for the installation and commissioning of the appliance. The installer must respect the following instructions:
4 Read and follow the instructions given in the manuals
provided with the appliance.
4 Carry out installation in compliance with the prevailing
legislation and standards.
4 Perform the initial start up and carry out any checks
necessary.
4 Explain the installation to the user. 4 If a maintenance is necessary, warn the user of the
obligation to check the appliance and maintain it in good working order.
4 Give all the instruction manuals to the user.
AWHP-2 MIT-IN-2 iSystem
1. Safety instructions
10/06/2015 - 7616372-001-05
10
1.4.3. User’s liability
To guarantee optimum operation of the appliance, the user must respect the following instructions:
4 Read and follow the instructions given in the manuals
provided with the appliance.
4 Call on qualified professionals to carry out installation
and initial start up.
4 Get your installer to explain your installation to you. 4 Ensure the Appliance is serviced in accordance with
the manufacturer’s instructions by a suitable qualified person.
4 Keep the instruction manuals in good condition close
to the appliance.
1. Safety instructions AWHP-2 MIT-IN-2 iSystem
11
10/06/2015 - 7616372-001-05
2 About this manual
2.1 General
This manual is also available on our internet site.
2.2 Symbols used
2.2.1. Symbols used in the manual
In these instructions, various danger levels are employed to draw the user’s attention to particular information. In so doing, we wish to safeguard the user’s safety, highlight hazards and guarantee correct operation of the appliance.
DANGER
Risk of a dangerous situation causing serious physical injury.
WARNING
Risk of a dangerous situation causing slight physical injury.
CAUTION
Risk of material damage.
Signals important information.
¼Signals a referral to other instructions or other pages in the instructions.
2.2.2. Symbols used on the equipment
4
Protective earthing
~
Alternating current
Before installing and commissioning the device, read carefully the instruction manuals provided.
Dispose of the used products in an appropriate recovery and recycling structure.
AWHP-2 MIT-IN-2 iSystem 2. About this manual
10/06/2015 - 7616372-001-05
12
Caution: danger, live parts. Disconnect the mains power prior to any operations.
2.3 Abbreviations
4 DHW: Domestic hot water
4 PPS: Polypropylene hardly inflammable
4 PCU: Primary Control Unit - PCB contoller for heat pump operation
4 PSU: Parameter Storage Unit - Parameter storage for PCBs
PCU and SU
4 SCU: Secondary Control Unit - DIEMATIC iSystem control panel
PCB
4 SU: Safety Unit - Safety PCB
4 3WV: 3-way valve
4 EVU: Power supply company
4 AWHP: Outdoor module connected by connection cable to the
indoor module
4 MIT-2: Indoor module fitted with a DIEMATIC iSystem control
panel
4 HP: Heat pump
4 COP: Performance coefficient
4 EER: Frigorific efficiency ratio
4 Flow temperature: Temperature of the water circulating in the
radiators or in the underfloor heating.
4 Ambient temperature: Temperature inside the house or in a room.
4 Room temperature setpoint: Temperature programmed in the
control system that must be reached by the heat pump.
1 2
M002628-A
2. About this manual AWHP-2 MIT-IN-2 iSystem
13
10/06/2015 - 7616372-001-05
3 Technical specifications
3.1 Homologations
3.1.1. Certifications
This product complies to the requirements to the european directives and following standards:
4 2006/95/EC Low Voltage Directive. Reference Standards:
EN60335-1 / EN60335-2-40.
4 2004/108/EC Electromagnetic Compatibility Directive. Generic
standards: EN1000-6-3 , EN 61000-6-1.
Apart from the legal provisions and Directives, the additional Directives described in these instructions must also be observed.
For all provisions and Directives referred to in these instructions, it is agreed that all addenda or subsequent provisions will apply at the time of installation
3.2 Technical specifications
3.2.1. Electricity supply
230 V AC (+/- 10%) - 50 Hz
400 V AC (+ 6%, - 10%) - 50 Hz (depending on the model)
3.2.2. Heat pump
Conditions of use:
4 Limit operating temperatures in Hot mode:
- Water: +18 °C / +60 °C (4, 6, 8, 11, 16 kW) Water: +18 °C / +55 °C (22, 27 kW)
- Outside air:
-15 °C / +35 °C (4, 6 kW)
-20 °C / +35 °C (8, 11, 16, 22, 27 kW)
4 Limit operating temperatures in Cooling mode:
- Water: +7 °C / +25 °C (At less than 18°C, it is necessary to use the HK24 insulation kit option)
- Outside air: +15 °C / +40 °C
4 Maximum operating pressure: 3 bar
AWHP-2 MIT-IN-2 iSystem
3. Technical specifications
10/06/2015 - 7616372-001-05
14
n
Performances in hot mode with outside air temperature at +7°C and outlet water temperature at +35°C (in accordance with EN 14511–2)
AWHP 4 MR 6 MR -2 8 MR-2 11 MR-2 11 TR-2 16 MR-2 16 TR-2 22 TR 27 TR
Calorific output - A7/W35 kW 3.72 5.87 8.26 10.56 10.56 14.19 14.19 19.40 24.4
COP hot - A7/W35
4.15 4.18 4.27 4.18 4.18 4.22 4.15 3.94 3.90
Absorbed electrical power - A7/W35 kWe 0.90 1.41 1.93 2.53 2.53 3.36 3.42 4.92 6.25
Nominal amperage - A7/W35 A 4.11 6.57 8.99 11.81 3.80 16.17 5.40 7.75 9.86
n
Performances in hot mode with outside air temperature at +2°C and outlet water temperature at +35°C (in accordance with EN 14511–2)
AWHP
4 MR 6 MR -2 8 MR-2 11 MR-2 11 TR-2 16 MR-2 16 TR-2 22 TR 27 TR
Calorific output - A2/W35 kW 3.76 3.87 5.93 10.19 10.19 11.38 11.38 12.10 14.70
COP hot - A2/W35
3.32 3.26 3.12 3.20 3.20 3.22 3.22 3.10 3.10
Absorbed electrical power - A2/W35 kWe 1.13 1.19 1.90 3.19 3.19 3.53 3.53 3.91 4.70
Nominal amperage - A2/W35 A 6.1 6.1 8.2 10.7 6.2 14.6 8.4 9.7 11.8
n
Performances in cold mode with outside air temperature at +35°C and outlet water temperature at +7°C (in accordance with EN 14511–2)
AWHP
4 MR 6 MR -2 8 MR-2 11 MR-2 11 TR-2 16 MR-2 16 TR-2 22 TR 27 TR
Cooling output kW 2.27 3.13 4.98 7.43 7.43 7.19 7.19 / /
EER
3.28 3.14 2.7 3.34 3.34 3.58 3.58 / /
Frigorific output range kW 1,12-4 1,12-4,5 2-6,6 3,2-9,1 3,2-9,1 4,1-12,5 4,1-12,5 6,2-15,2 7,6-18,7
Absorbed electrical power kWe 0.69 1.0 1.85 2.22 2.22 2.01 2.01 / /
n
Performances in cold mode with outside air temperature at +35°C and outlet water temperature at +18°C (in accordance with EN 14511–2)
AWHP
4 MR 6 MR -2 8 MR-2 11 MR-2 11 TR-2 16 MR-2 16 TR-2 22 TR 27 TR
Cooling output kW 3.84 4.69 7.90 11.16 11.16 14.46 14.46 17.65 22.2
EER
4.83 4.09 3.99 4.68 4.68 4.43 4.43 3.80 3.80
Frigorific output range kW 1,7-4,5 1,7-4,5 2,6-9,5 4,6-14 4,6-14 5,8-16 5,8-16 9-22,4 11,2-28
Absorbed electrical power kWe 0.72 1.15 2.0 2.35 2.35 3.65 3.65 4.65 5.84
3. Technical specifications AWHP-2 MIT-IN-2 iSystem
15
10/06/2015 - 7616372-001-05