2
Vandal Resistant Domes
Contents
Introduction .......................................................3
Important Safeguards........................................4
Installation .........................................................5
Switch Settings..................................................8
Appendix ........................................................... 10
Quickstart ..........................................................11
Template............................................................ 15
Whilst every attempt is made to ensure these manuals are accurate and current, Dedicated Micros reserve the right to
alter or modify the specication of the machine described herein without prejudice.
Introduction
These instructions cover ICE series xed dome cameras. Read all of these instructions. Use them to install your camera and have them available for its lifetime. If you have any problems, contact your agent.
Models
Mono high resolution 570 TVL 0.07 lux at F1.2 Vandal Resistant
DM/ICEDVC-BH39 Ceiling mount DM/ICEDVS-BH39 Surface mount
DM/ICEDVS-OBH39 Surface mount with outdoor heater
Colour/Mono high resolution 480 TVL 0.7 lux at F1.2 Vandal Resistant
DM/ICEDVC-CMH39 Ceiling mount DM/ICEDVS-CMH39 Surface mount
DM/ICEDVS-OMH39 Surface mount with outdoor heater
Colour/Mono ultra resolution 540 TVL 0.7 lux at F1.2 Vandal Resistant
DM/ICEDVC-CMU39 Ceiling mount DM/ICEDVS-CMU39 Surface mount
DM/ICEDVS-OCMU39 Surface mount with outdoor heater
Day/Night ultra resolution 540 TVL 1.0 / 0.15 lux at F1.6 Vandal Resistant
DM/ICEDVC-DNU39 Ceiling mount DM/ICEDVS-DNU39 Surface mount
DM/ICEDVS-ODNU39 Surface mount with outdoor heater
Each model uses a 1/3” SuperHAD™ CCD.
Vandal Resistant Domes
Dedicated Micros ©2007
3
Dedicated Micros ©2007
4
Vandal Resistant Domes
Important Safeguards
WARNING
CAUTION
CAUTION
Product Safety
Installation and servicing is only to be carried out by suitably qualied and experienced personnel.
Do not remove covers as there is a risk of injury or death by electric shock.
Only power low voltage dome cameras from a class 2 isolated power supply.
This camera range is designed for use in general purpose CCTV applications and has no other
purpose.
Only operate your camera between the temperatures of -10°C and +50°C. Do not operate your camera outside its specied power supply range.
Electromagnetic Compatability (EMC)
This product is intended solely for use in general CCTV applications.
The product must be installed and maintained in accordance with good installation practice to enable the product to function as intended and to prevent problems. Refer to your agent for installation guidance.
Declaration of Conformity
The manufacturer declares that the equipment supplied with this manual is compliant with the essential protection requirements of the EMC directive 89/336 and the Low Voltage Directive LVD 73/23 EEC.
Conforming to the requirements of standards EN55022 for emissions, EN61000-4 parts 2, 3, 4, 5, 6 and 11 for immunity and EN60950 for Electrical Equipment safety.
Camera Care
In order to avoid damaging your camera, note the following points:
Remove all packaging inserts and the protective lm from the dome cover before using the camera.
Do not touch the image surface of the sensor. If the sensor is accidentally touched, only clean it using isopropanol.
Do not expose the camera sensor to very bright light over a long period of time as this may cause damage to the CCD sensor. The camera and lens set-up must be correct to avoid possible damage due to long term exposure to bright light. A lens with an automatic iris is recommended under these conditions.
Installation
The ICE xed dome camera is available in two versions: the ceiling mount version for installation into a ceiling tile of up to 1.5” (38 mm) thickness; and the surface mount version for installation directly onto a hard surface or mounting structure. When installing the outdoor vandal resistant dome you must set the jumpers on the thermostat PCB to the correct supply voltage being used.
Parts Supplied
Ceiling Mount Models Surface Mount Models
2 x Fixing screws 4 x Fixing screws
2 x Wall plugs 4 x Wall plugs
2 x Machine screws 4 x O-rings
2 x Sprung toggle clips Custom torx key
Custom torx key This booklet
This booklet
Parts Not Supplied
Optional video service lead (part number DM/ICED-SERV)
Ceiling Mount Installation
Refer to the Quickstart section for more information.
1 Loosen the two torx screws on the front of the camera using the torx screw key
supplied.
2 Gently pull away the dome cover from the camera body and remove the plastic
shroud. The dome cover is attached to the camera body with a retaining cord. Do not undo or cut this cord.
3 Using the template supplied at the rear of this booklet, mark and drill two 5/8”
(16 mm) holes at opposite sides of the large hole. Mark and cut a 4” (100 mm) diameter hole. Check that the holes are large enough to enable the safety lugs on the camera body to pass through.
Mark and drill the two screw holes for xing the camera body. Two pairs of screw
holes are provided on the camera body for ease of xing. Use only one pair of screw holes. A 5 mm drill bit is suitable for use with the supplied wall plugs.
4 Connect the video cable to the BNC connector at the end of the ying lead or
directly to the BNC connector on the camera body. Use only one of the BNC connectors to connect the video cable. Connect the power cable to the power terminals. The camera operates from a 12V DC or 24V AC power supply. Connections and polarity are indicated next to the terminals. The power supply must be a UL Listed, Class 2 isolated type.
5 Optionally attach a safety chain (not supplied) to one of the lugs and secure the
other end of the safety chain to a xed object.
6 Insert the camera body into the hole and x it to the ceiling tile using either the
wood screws and wall plugs supplied or the two machine screws and sprung toggle clips. Do not over-tighten the screws.
7 Optionally attach a local monitor to the test point using an DM/ICED-SERV service
connector (available separately) and adjust the camera as described earlier.
8 Visually align the screws on the dome front cover with the screw holes on the
camera body to assist in replacing the dome cover.
Replace the dome front cover and tighten the torx screws, taking care not to
trap the retaining cord in the edge of the front cover. Do not over-tighten the torx screws.
Vandal Resistant Domes