Installation
The ICE xed dome camera is available in two versions: the ceiling mount version for installation
into a ceiling tile of up to 1.5” (38 mm) thickness; and the surface mount version for installation
directly onto a hard surface or mounting structure. When installing the outdoor vandal resistant
dome you must set the jumpers on the thermostat PCB to the correct supply voltage being used.
Parts Supplied
Ceiling Mount Models Surface Mount Models
2 x Fixing screws 4 x Fixing screws
2 x Wall plugs 4 x Wall plugs
2 x Machine screws 4 x O-rings
2 x Sprung toggle clips Custom torx key
Custom torx key This booklet
This booklet
Parts Not Supplied
• Optional video service lead (part number DM/ICED-SERV)
Ceiling Mount Installation
Refer to the Quickstart section for more information.
1 Loosen the two torx screws on the front of the camera using the torx screw key
supplied.
2 Gently pull away the dome cover from the camera body and remove the plastic
shroud. The dome cover is attached to the camera body with a retaining cord. Do
not undo or cut this cord.
3 Using the template supplied at the rear of this booklet, mark and drill two 5/8”
(16 mm) holes at opposite sides of the large hole. Mark and cut a 4” (100 mm)
diameter hole. Check that the holes are large enough to enable the safety lugs on
the camera body to pass through.
Mark and drill the two screw holes for xing the camera body. Two pairs of screw
holes are provided on the camera body for ease of xing. Use only one pair of
screw holes. A 5 mm drill bit is suitable for use with the supplied wall plugs.
4 Connect the video cable to the BNC connector at the end of the ying lead or
directly to the BNC connector on the camera body. Use only one of the BNC
connectors to connect the video cable. Connect the power cable to the power
terminals. The camera operates from a 12V DC or 24V AC power supply.
Connections and polarity are indicated next to the terminals. The power supply
must be a UL Listed, Class 2 isolated type.
5 Optionally attach a safety chain (not supplied) to one of the lugs and secure the
other end of the safety chain to a xed object.
6 Insert the camera body into the hole and x it to the ceiling tile using either the
wood screws and wall plugs supplied or the two machine screws and sprung toggle
clips. Do not over-tighten the screws.
7 Optionally attach a local monitor to the test point using an DM/ICED-SERV service
connector (available separately) and adjust the camera as described earlier.
8 Visually align the screws on the dome front cover with the screw holes on the
camera body to assist in replacing the dome cover.
Replace the dome front cover and tighten the torx screws, taking care not to
trap the retaining cord in the edge of the front cover. Do not over-tighten the torx
screws.