The updated CamVu500 is the latest addition to Dedicated Micros range of CamVu IP Cameras. Providing
excellent low light, performance the CamVu500 can transmit and record images in real-time and is designed
for Dedicated Micros next generation of video surveillance - Closed IPTV.
EXCELLENT LOW LIGHT PERFORMANCE
The CamVu500 uses a 1/4” CMOS progressive scan sensor that provides exceptional low light resolution
(<0.3 lux, @ F1.2). This incredible performance allows colour images to be produced in dimly lit scenes.
MULTIPLE, SIMULTANEOUS VIDEO STREAMS
Dedicated Micros’ unique Visual Signal Processor (ViSP) allows the CamVu 500 to transmit multiple
simultaneous MPEG-4, H.264 and/ or JPEG images to any number of associated NetVu Connected devices
for image viewing. Each stream can be tailored to suit the viewer’s bandwidth requirements.
11246
ANALYTICSCAPABLE
As part of our growing range of AnalyticsCapable products, the CamVu Day/Night dome is able to contain
the latest analytics solutions from Dedicated Micros including Object Left/Removed Detection Tripwire and
Counting Tripwire, all locally hosted on the camera.
11245
CLOSED IPTV
Dedicated Micros’ award winning Closed IPTV solution combines open standard IP protocols with patent
pending innovation to provide simple to install, safe and secure IP video solutions across new or existing
networks.
Automatically allocating IP addresses to IP cameras by physical port, a Closed IPTV system is completely
deterministic, creating rewalls and monitoring point-to-point IP connections so they cannot be hacked
or intercepted. Critical to the security of a Closed IPTV system is the unique implementation of Trusted
Endpoint technology; a secret signature, applied at lock down, enables endpoint devices such as IP
cameras to be secure, immediately triggering a security alert should any interference be detected.
This ground breaking solution provides a very simple and secure answer to IP video, meaning that no prior
knowledge of IP networking is required. Sophisticated and Dependable network security can be achieved
with a single click.
Features
■ Colour IP Mini-dome with excellent low light sensitivity
■ Integrated Camera Recording and full enterprise video server within camera
■ 0.3 lux F1.2
■ Can form part of a Closed IPTV system
■ Transmission of multiple, simultaneous video streams in MPEG-4, H.264 and JPEG format
enables multiple users to view video streams at the settings they require
■ AnalyticsCapable - enables analytics solutions to be deployed on your CCTV system
■ Direct conguration from any compatible NetVu Connected DVR or Video Server
Before installing unit, please verify that all items listed below have been supplied:
1 x CamVu Camera
1 x POE Injector Cable
1 x User Guide
1 x CD containing information for use with the camera
Note: A PSU is not supplied with this camera. A suitable 12Vdc 0.5A PSU is required if powering
the unit from its DC input connector - VS-PSU15W-EXT can be purchased separately from
Dedicated Micros.
If the camera utilises Power Over Ethernet, a separate PSU is not necessary (if power is
available via the Ethernet connection).
Alternatively if powering the unit over PoE using the supplied injector, a 48Vdc PSU that can
supply 15W is required - DM/PSU/48V can be purchased separately from Dedicated Micros.
This section contains the regulatory declarations for the EU for the Unit Camera.
This product is marked with the CE symbol and indicates compliance with all applicable Directives. A
“Declaration of Conformity” is held at Dedicated Micros Ltd, 1200 Daresbury Park, Daresbury, Cheshire WA4
4HS www.dedicatedmicros.com
CamVu 500
Hereby, Dedicated Micros LTD, declares that this Unit Camera is in compliance with the essential
requirements and other relevant provisions of Directive 95/5/EC.
Marking by the symbol CE indicates compliance of this Dedicated Micros product to the Electromagnetic
Compatibility Directive 89/336/EEC, and the Low Voltage Directive 73/23/EEC of the European Union. Such
marking is indicative that this system meets the following technical standards
• EN 61000-6-3 EMC Standard Residential, Commercial and Light Industry.
• EN 62000-3-3 Limitations of voltage changes, uctuations and icker in public low-voltage
supply systems for equipment with rated current up to 16A.
• EN 61000-3-2 Limits for harmonic current emissions for equipment with rated current up to 16A.
• EN 50130-4 Immunity requirements for components of re, intruder and social alarm systems.
• EN 60950 Safety of IT and similar equipment.
• EN 55022 Class A. Radiated Emissions Standard, suitable for Commercial or Residential use
Further details about these applicable standards can be obtained from Dedicated Micros Ltd., 1200
Daresbury Park, Daresbury, Cheshire WA4 4HS
1.01002
RF Interference warning
This is a class A product. In a domestic environment this product may cause radio frequency interference , in
which case the user may be required to take adequate measures.
1.01003
Canadian EMC statement
This product is compliant with Class A ICES-003
Note: This Class A product meets the requirements of the Canadian Interference causing equipment
regulations. Cet appareil numerique de la Classe A, respect toutes les exigencies du reglement
sur le materiel brouilleur du Canada.
Important Safeguards
4.15
Read Instructions
All the safety and operating instructions should be read before the unit is operated and adhered to during
operation. These instructions should be retained with the unit, and all warnings and cautions contained
should be heeded.
Power Sources
This unit should be operated only from the type of power source indicated on the manufacturer’s label.
This product supports POE and when connected to a suitable switch, will not require an external PSU to
drive the device (Bridge and end-span compatible).
Servicing and Repair
Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous
voltage or other hazards.
Refer all servicing and repair to qualied service personnel.
Equipment
Use only attachments/accessories specied by the manufacturer.
Ventilation
Ensure unit is properly ventilated to protect from overheating.
Camera Care
In order to avoid damaging your camera, note the following points:
CAUTION
• The camera has threaded mounting points on the top and bottom of the case. Only use a
standard, photographic mounting bolt with a 1/4-20 UNC thread.
• Before tting the lens, make sure that its back will not touch the CMOS sensor or associated
components when screwed fully home.
• Do not touch the image surface of the sensor. If the sensor is accidentally touched, only clean it
using isopropanol.
• Do not expose the camera sensor to very bright light over a long period of time as this may
cause damage to the sensor. The camera and lens set-up must be correct to avoid possible
damage due to long term exposure to bright light. A lens with an automatic iris is recommended
under these conditions.
The CamVu 500 features push t connectors which house connections for 12VDC power. There is also
a PoE capable RJ45 socket for connection to a suitable network point. The BNC video output connection
is used in conjunction with a local monitor to focus the camera during installation and can also be used to
display the camera’s current network settings.
Note: The BNC output only operates for 10 minutes after the camera is powered up.
CamVu 500 cameras are available in PoE plus AC/DC low voltage types. The voltage required to operate
the camera is clearly marked on the rear panel of the camera. The power LED on the rear panel indicates
that power is connected.
Power over Ethernet
The camera can be powered from any suitable PoE injector conforming to IEEE 802.3-2008. End span and
bridging injectors supported.
Auto-Switching Low Voltage Power Supply
The camera is tted with an automatic selecting power supply operate between 12 VDC and 24 VAC.
Connections and polarity are indicated beside the connector on the rear panel. The power supply must be a
class 2 isolated type.
CamVu 500
Network Connections
Connection to a 10/100 BaseT network is made via the RJ45 on the rear panel.
Video Connector
Connect a video coaxial cable terminated with a 75Ω BNC connector to the BNC socket marked VIDEO
OUT on the rear of the camera to align the camera.
Note: This video output is only active for 10 minutes after the unit is powered up.
Fixed and Manual iris lenses (for indoor use only) require no wiring connections.
Auto Iris Lens
Connect the auto iris lens to the four-pin connector located on the side of the camera. If the lens does not
have a DD plug tted then wire the lens to a suitable plug. Pin connections for the iris drive plug are shown
below.
PIN DIRECT DRIVE AUTO IRIS LENS
1 Control coil positive (+)
2 Control coil negative (-)
3 Drive coil negative (-)
CamVu 500
4 Drive coil positive (+)
POE Injector Cable
The POE Injector cable is designed to enable the use of POE (Power over Ethernet) before a POE capable
switch has been installed. It is installed alongside a suitable 48Vdc PSU that can supply 15W is required DM/PSU/48V can be purchased separately from Dedicated Micros.
A Connection to DVR/NVR/Layer 3 Enhanced CCTV Switch
B Connection to suitable 48Vdc 15W PSU - (DM/PSU/48V)
C Ethernet cable connection to camera.
Important: 48V is supplied to connection C. There is no voltage at Connection A. Do NOT
POE Injector Power Supply specication
Adaptor socket - 5.5mm diameter with a 2.1mm central circular pin
10
+48V goes to the centre pin of the power connector - 0V to the outside barrel
connect an ethernet cable from connection C to the DVR/Layer 3 Enhanced CCTV
Switch as this could cause irreparable damage.
The back focus adjustment is located at the front of the camera and is accessible from either the top or
bottom of the case.
To adjust the back focus:
1. Loosen the two back focus mechanism locking screws (top and bottom of the camera).
2. Turn the back focus ring anti-clockwise (when viewing the front of the camera) until the CMOS
sensor assembly is as far away from the back of the lens as possible.
3. Turn the back focus ring clockwise until focus is achieved.
4. When the back focus adjustment is satisfactory, tighten the locking screws. Do not over-turn or
force the back focus adjustment ring.
Note: Always turn the back focus ring such that during focusing, the CMOS sensor assembly is
brought towards the back of the lens (i.e. clockwise). If the point of best-focus is passed, repeat
the back focus procedure from step 2.
1) Connect the camera to a Closed IP Network switch using Cat5 network cable. The POE version
of this camera will draw power from with the DM/NSW/CPP model switch, or with DM/NSW/CP
model switch if connected to a POE injector and separate power supply.
2) Ensure that the Closed IP NVR or Console that the switch is connected to is in Conguration
mode to allow new cameras connect.
3) Power up the camera and wait for the on-screen acknowledgement on the monitor attached
CamVu 500
Locating the Unit IP address
The unit is congured using on-board webpages. This can be done remotely once the unit has been installed
in its chosen location, using the web browser on a PC in the same subnet as the unit.
The unit conguration pages can be accessed using the unit IP address or DNS name. The unit has
DHCP factory enabled. When the unit is connected to a DHCP network for the rst time, an IP address is
automatically assigned by the network switch or router it is connected to. Most routers will have the facility to
enable DHCP and DNS, if it is not available, contact your network administrator.
The default DNS address for each unit is factory set as the serial number. This address can be found on the
serial label on the unit or via the packaging the unit came in.
If DHCP and DNS are not available, the IP address can be found by connecting an analogue monitor to
the BNC connection of the camera. The unit IP address is displayed on the analogue video output for 10
minutes from powering the unit on.
The DNS or IP address can be typed directly into the address bar of a web browser.
to the Closed IP NVR or Console. Alternatively check the Camera Overview web page on the
Closed IP NVR or Console to determine out the camera status.
4) Once the camera has been detected and added, remember to secure the switch by moving out
of Conguration mode, failure to do this will leave the Closed IPTV system unsecured.
Note: The unit’s DNS address can be changed subsequently to something more memorable
or meaningful than its serial number by editing the System name option in the System
conguration page.
Zero_conf conguration
If a permanent IP address is not assigned to the unit, it will attempt to contact the DHCP server every
time it starts up, and periodically thereafter. The unit support zero-conguration networking (sometimes
known as Bonjour), this enables automatic discovery of computers, devices, and services on IP networks.
Zero-conguration uses industry standard IP protocols to allow devices to automatically discover each
other without the need to enter IP addresses or congure DNS servers. By loading a suitable free add-on
to your web browser such as Bonjour for Windows for Internet Explorer or BonjourFoxy for FireFox zero
conguration devices such as this unit can easily be discovered and accessed.
The menus under the System heading allow the unit’s core settings to be viewed, changed and the system
software upgraded.
The Attributes option displays details about the unit including the IP address, unit serial number, MAC
address and software version.
The Status page displays information about the unit’s operating condition, shows how long the unit has been
operating and the reason for the last reset. It also shows the camera status.
CamVu 500
The Language page allows the system language to be set. The language can also be changed for the
current session only.
The Time and Date page allows the unit time and date settings to be adjusted, including setting
the timezone.
The Features page allows control of the different features that are available within the software including
Email reporting and control of the display resolution.
The Maintain page allows the current conguration to be saved, and for previously saved settings to
be loaded.
The PowerScript management pages allows individual PowerScripts to be disabled if required.
This menu shows the general information about the unit including the version of software installed, the unit’s
serial number and the allocated DHCP IP address.
The system will display a warning if user accounts have not been set up. These can be eliminated by setting
up accounts in ‘Display->User Accounts’.
CamVu 500
Product Descriptor Details the product model.
Serial Number Identies the serial number of the specic unit.
PCB Serial Number Displays the PCB (Printed Circuit Board) serial number of the unit.
Product Code Displays a code identifying the unit’s specication.
Earliest Recording Displays the date/time of the earliest recording held on the unit.
System Name This eld can be edited to allocate a name to the unit, which can be
typed directly into a browser to access the conguration pages. This
is displayed when the unit is accessed via NetVu ObserVer and is
sent when transmitting information to a Remote Video Response
Centres (RVRC).
MAC Address This is the MAC address assigned to the unit.
IP Address These are the IP addresses allocated to the unit (zeroconf and
interface IP addresses are displayed in Closed IPTV operation)
Sub Net This is the subnet mask for the unit
Gateway This is the IP address of the default gateway (router) assigned by the
DHCP server.
Number of Cameras Shows the number of camera channels on the unit i.e 1
Global PPS Details the unit Global PPS (Pictures Per Second) recording rate.
Video Storage Gbytes Highlights the available video storage capacity in Gigabytes.
Video Standard Displays the video standard adopted by the unit i.e. PAL, NTSC.
Software (Red) Links to the System Settings->Software details page
Time/Date (Green) Links to the System->Time and Date page
Accounts (Yellow) Links to the Viewer Settings->User Accounts details page
Network (Blue) Links to the Network Settings->Network details page
Refresh (Purple) Refreshes the current page
This menu details information regarding the status of the unit, notably the total time the unit has been
operating and the time since its last reset.
CamVu 500
18
Time since last reset Details the time since the unit was last reset.
Total running time Details the total time the unit has been operational.
Reset code The last reset code used is displayed.
Restart reason The reason for the last restart is displayed i.e. Controlled
This page provides quick links to the pages required to fault nd.
CamVu 500
System Information Opens the System Settings->System page.
Software Revisions Opens the System Settings->Software page.
General Information Opens the General Information page (refer to ‘General Information’).
Record Details Opens the Record Details page (refer to ‘Record Details’).
Camcong Details Opens the Camcong Details page (refer to ‘Camcong Details’).
Capabilities Opens the Capabilities Details page (refer to ‘Capabilities Details’).
UI Information Opens the UI Information page (refer to ‘UI Information’).
Prole Record Tables Opens the Prole Record Tables page (refer to ‘Prole Record’).
Glossary Opens the Glossary page (refer to ‘Glossary’).
This page displays the capabilities of the camera in terms of resolution and supported compression formats.
This camera does not support audio, alarms, relay or lens de-warping so all these parameters return 0.
CamVu 500
22
About (Blue) Opens the About page
Refresh (Purple) Refreshes the current page
This menu allows the system language to be set. Changing the System Language will effect all menu pages.
If required, the language can also be changed for the current session only.
CamVu 500
System Language Select to change the system language setting.
Note: A server reboot will be required to implement system language changes. The unit can be
rebooted via System Settings->Maintain->Reset, or by pressing ‘Red’ while on this page.
Session Language Select to change the language settings for the current
session only.
Choose Select to immediately activate session language changes.
Reset (Red) Resets the unit
Refresh (Purple) Refreshes the current page
System Time The current system time and date is displayed.
Current Time Zone Displays the currently selected time zone settings.
Time Zone Select the relevant timezone offset from the accompanying drop
down menu.
Date Format As default, the date is entered dd/mm/yy. It can also be displayed as
mm/dd/yy or yy/mm/dd.
Reset(Red) Resets the unit
Time Format As default, the time displayed is in 12 hour format. This can be
changed to 24 hour if required.
SNTP Server A Simple Network Time Protocol (SNTP) server allows external
devices to connect and set their current date and time settings to that
of the SNTP. If required, enter the SNTP server IP address here.
Set Time Allows current unit time to be updated.
Set Time (Green) Applies the new time.
Set Date Allows current unit date to be updated.
PC Time Displays the system time of the PC currently being used to view
This menu enables the activation of system features such as Email Reporting.
System (Red) Opens the System Features page
Network (Green) Opens the System Features Network page (below)
Video (Yellow) Opens the System Features Video page (below)
Other (Blue) Opens the System Features Other page (below)
CamVu 500
Refresh (Purple) Refreshes the current page
System Features
32
User Logging Enable this option to activate User Logging, refer to ‘Appendix A’ for
further information regarding the User Logging function.
Text in Images Select this option to activate the Text in Images function, refer to
‘Analytics & Text-Text In Image’ for more information.
Note: When de-selected here, the ‘Text in Image’ menu will no longer be displayed in the menu tree.
Email Reporting Select this option to activate the Email Reporting function, refer to
Note: When de-selected here, the ‘Email Reporting’ menu will no longer be displayed in the menu tree.
Remote Reporting Select this option to activate the Remote Reporting function, refer to
‘Network Settings-Remote Reporting’ for more information.
Note: When de-selected here, the ‘Remote Reporting’ menu will no longer be displayed in the menu
tree.
Automatic FTP Download Select this option to enable automatic FTP downloads to upgrade the
unit and/or the webpages, refer to ‘Network->FTP Download’ for more
information.
Note: When de-selected here, the ‘Automatic FTP Download’ menu will no longer be displayed in
the menu tree.
Webcam Support Select this option to activate the Webcam function. This allows the
unit to emulate a webcam and send image from one video feed in
webcam format, refer to ‘Network Settings->Web Cam’ for more
information.
Note: When de-selected here, the ‘Web Cam’ menu will no longer be displayed in the menu tree.
SMB Server Support Select this option to activate the SMB (Server Message Block)
le sharing function. When activated, the SMB protocol allows the
unit to access PCs operating the Windows operating system (and
Linux machines running Samba). This enables sharing of les and
directories to/from the unit. The name of the SMB Workgroup on the
network must be correctly entered in the SMB Workgroup option (see
below). It is important that the Server Name assigned to the unit via
‘Network Settings->Server Name’ is unique within the workgroup
being used. To access the unit via a PC running SMB (and has
access to the same Workgroup); open My Network Places-Entire
Network- Microsoft Windows Network. The Workgroup containing the
unit and PC(s) should then be available. Files and folders can then be
copied/added as required.
Camera Masking Select this option to activate the Camera Masking function, refer to
‘Alarm Settings-Masked Cam Detection’ for more information.
Note: When de-selected here, the ‘Masked Camera Detection’ menu will no longer be displayed in the
menu tree. Camera Masking
System (Red) Select to open the System->Features->System page
Network (Green) Select to open the System->Features->Network page
Video (Yellow) Select to open the System->Features->Video page
Other (Blue) Select to open the System->Features->Other page
Refresh (Purple) Refreshes the information on the current page.
Secondary Web Port If the default port setting for web serving has already been allocated,
it is possible to congure a second port number i.e. the secondary
web port can be set to 8000 if the default web port (80) is blocked by
the network or rewall.
Use Record Proles for Tx High This option sets the Video Transmission prole for the ‘High’ setting
to be identical to the settings (rate/quality/resolution) that are being
recorded.
Samba Workgroup Enter the name of the Samba workgroup to enable sharing of les
and directories to/from the unit. To access the unit via a PC running
SMB (and has access to the same Workgroup); open My Network
Places-Entire Network- Microsoft Windows Network. The Workgroup
containing the unit and PC(s) should then be available. Files and
folders can then be copied/added as required.
Auto IP Override This is defaulted to allow zero conguration at the factory. Select
Disable to prevent Zero Cong address negotiation.
Max Client Connections This setting limits the number of client connections to the server.
The default value is 256 but could be increased if there is heavy
network trafc.
ARP Cache Size This setting limits the number of cache entries available in the ARP
table. The default setting of 256 is adequate for most instances
TCP Reassembly Queue Limit This setting limits the maximum number of TCP segments allowed in
Remote Codec Default Connection
System (Red) Select to open the System->Features->System page
Network (Green) Select to open the System->Features->Network page
Video (Yellow) Select to open the System->Features->Video page
Other (Blue) Select to open the System->Features->Other page
Refresh (Purple) Refreshes the information on the current page.
the reassembly queue, to protect against a common DoS attack.
This selects the initial connection type to use for an auto congured
remote codec camera, select from TCP or UDP
System Features Video
CamVu 500
Detected Video Standard
Analogue Output Resolution Allows selection of the resolution, options are 704 x 576, 704 x 512
Deinterlace Filter
3D Input Filter Options are Off, Time Domain Filter, Spatial Filter, or Both.
The unit automatically detects the video standard being used i.e. PAL/NTSC.
and 640 x 512
Select this option to improve display clarity and minimise the comb effect
that may be visible when recording high motion scenes in high resolution.
35
Page 36
Segment Aspect Ratio This setting control how a 4:3 image is displayed in a multi-screen or
System (Red) Select to open the System->Features->System page
Network (Green) Select to open the System->Features->Network page
CamVu 500
Video (Yellow) Select to open the System->Features->Video page
Other (Blue) Select to open the System->Features->Other page
Refresh (Purple) Refreshes the information on the current page.
wide screen format on the local viewer. The available display segment
changes depending on the number of multi screen images selected
for display. Stretch forces the image to ll the available display
segment. This may result in some distortion of the display image.
Zoom Fit forces the frame to ll the available segment completely and
proportionally. Consequently some of the image at the top and bottom
of the frame may be cropped. Frame Fit forces the frame to ll the
available segment proportionally, resulting in black bars left and right
on some multi display choices.
System Features Other
36
Auto Update Web Variables This is used to enable/disable the conguration webpage auto
update acceptance option which is displayed when the conguration
webpage version has been updated.
The default is to auto accept and update the conguration pages.
Enable Event Search Page Select to enable the Event Search option.
Note: When de-selected here, the ‘Event Search’ menu will no longer be displayed in the menu tree.
Enable RVRC page Select this option to activate the RVRC Remote Set/Unset/Override
function, refer to ‘Record Settings-RVRC’ for more information.
Note: When de-selected here, the ‘RVRC’ menu will no longer be displayed in the menu tree.
Network (Green) Select to open the System->Features->Network page
Video (Yellow) Select to open the System->Features->Video page
Other (Blue) Select to open the System->Features->Other page
Refresh (Purple) Refreshes the information on the current page.
This page enables you to select which PowerScripts are automatically run when the unit starts up. Use the
tickboxes below to select which scripts you require and then click Save.
Note: You will need to restart your unit for the changes to take effect.
Note: Clicking Save will alter DEFAULT.C, if you already have a custom PowerScript on your unit
which uses the DEFAULT.C le, please contact your regional Technical Support before using
this page.
CamVu 500
Reset(Red) Resets the unit
Save (Green) Saves the current settings
Refresh (Purple) Refreshes the current page
Applet Location The location of the unit’s Viewer menu applet is displayed. The default
CamVu 500
Set Location Select the applet location. Choose from ‘Default location’ i.e. the
Reset (Red) This button will restart the unit.
Refresh (Purple) Refreshes the current page
location will always be the applet installed on the unit. If accessing
multiple units via a remote connection, all can be assigned the same
Viewer applet. This will lessen the load time required when accessing
different systems.
For example, if a local unit and a remote DVR are to be accessed, it
is possible to set the Applet location for both DVRs as the local unit.
If viewing the unit remotely, Dedicated Micros provide a remote applet
located on the Dedicated Micros website (www.dedicatedmicros.
com/software_release/windows/viewer-applet.jar). Due to possible
bandwith restrictions on the network the DVR is located, using this
remote applet may improve data transfer speeds.
applet installed on the unit; or the ‘Dedicated Micros website’
option i.e. the remote applet.
The unit can protect conguration procedures by limiting access via usernames and passwords. By default,
no usernames and passwords are congured for any account type.
CamVu 500
Account Types The available account types for which users and passwords can be
assigned privileges are:
Admin FTP
Assigning username and password requirements for the Admin
FTP function will limit access to the unit via an FTP connection.
Assigning username and password requirements for Serial
Menu Conguration
Assigning WebPage Conguration privileges will limit access to
Local Users
CamVu 500
Assigning Local Users access privileges will limit access to the
Default Username:dm Default Password:none
Remote Users
Assigning a username and password protects camera images
Note: Where there are no assigned, access will be granted to all users and no request for a username
and password will be made.
Account List When an Account Type is highlighted, details of users with access will
Add(Red) Highlight an administration feature i.e. Serial and select ‘Add’. Enter
Modify (Green) To modify a user’s settings, highlight the user in the list and press
Delete (Yellow) To delete a user’s settings, highlight the user in the list and press
Account Info (Blue) Opens a detail page displaying information about the settings.
connections will limit access via a Serial link.
Default username:none Default Password:none.
the Conguration menus when viewed remotely. When implemented, the user will be prompted for a username and password before access to the Conguration menus (via the
main menu) will be granted.
Default Username:dm Default Password:none
Viewer pages for local users. When implemented, the local user
will be prompted for a username and password before access to
the Viewer pages (via the main menu) will be granted.
from unauthorised access.
Default username:none Default Password:none.
be displayed.
the new User Name and Password. That user’s name will now be
displayed in the account list.
This menu allows the conguration of local camera settings for the unit.
CamVu 500
46
Camera Title This title can be edited to allocate a name to the unit. This is
displayed when the unit is accessed via NetVu ObserVer and is set
when transmitting information to a Remote Video Response
Centre (RVRC).
Lens Select Set the camera to support Manual Iris or DC Drive lens. DC drive lens
are congured on the Iris Control page, refer to Camera->Iris Control.
Auto white balance Enables auto tracing white balance.
Electronic Iris Allows the camera to provide electronic iris control if manual lens is
selected.
Exposure Level Sets the target exposure level that the electronic iris will try to attain.
This can be used to adjust the brightness of the image.
Flip Video Used to invert the image when the camera is mounted upside down.
Mirror Video Select to ‘mirror’ the camera image (horizontal ip).
Sharpness Manually adjust the image sharpness.
Decrement - (Green) Decrease sharpness
Increment + (Yellow) Increase Sharpness
Refresh (Purple) Refreshes the current page
This menu is for advanced use only. It is factory set and should not require any alteration.
Under normal operating conditions no adjustment is needed, however in certain circumstances benets may
be seen through minor adjustment for some DC drive lens.
CamVu 500
Iris Response This will change the speed at which the Iris will respond to changes
in lighting conditions. The default is for a medium speed of response
however this can be set to react slower or faster to changes in the
scene as desirable to suit lens types and conditions.
Iris Offset Iris Offset is calibrated from the factory. However it may be necessary
to adjust this setting for different manufacturers lenses to allow for
differences in their specication. If the images from the camera
are pulsing in brightness, start by incrementing slowly until an
improvement is seen. If by doing this the pulsing is actually getting
worse,decrement instead to correct. If stability can not be reached
then use the slower Iris response setting.
Save (Red) Save the current settings.
Decrement - (Yellow) Use the button to reduce the zero crossing point setting by 1
Increment + (Blue) Use the button to increase the zero crossing point setting by 1
Refresh (Purple) Refreshes the current page
The ICR Settings menus allow conguration of the unit’s record functions. ICR settings can be congured for
normal operation, on alarm, by schedule and for set holiday and weekend periods. Selected video data can
be saved and protected. Refer to the individual menus for further details.
The Default page allows the basic Recording settings to be edited.
The Prole Record page allows the recording conguration to be based on specic priorities. The record
rate and quality can be customised to respond appropriately to the alarms and time of day. A high degree of
control and exibility is possible using these options.
CamVu 500
The Protect Video page allows previously recorded data to be protected and retained. If needed, all
recording can be halted and saved video deleted.
The AoE page allows conguration of the units ATA over Ethernet (AoE) function. AoE is a network protocol
designed for simple high-performance access of storage devices over Ethernet networks Importantly the
external storage device must be located on the same network as the unit.
The Video Storage page displays drives that are available for video recording and allows the formatting and
allocation of these devices.
The unit has a range of pre-dened congurations available. As standard the unit can record at 5pps
MPEG4 and at a selected number of days. Alternatively the unit can be congured for 2pps JPEG recording
on each camera or for MultiMode operation (note that this will result in the record duration being determined
by the time period the unit is in alarm).
Note: This page is only relevant if images are being recorded to the camera. If a DVR is being used,
recording direct to the camera may be disabled.
CamVu 500
Days
Recording Displays the record duration possible using the current conguration.
Timed Expiry If required, all stored recorded video can be permanently deleted after
Camera Settings Choose the rate of non alarm recording to be used from the range
Record Duration/Enhance Quality The recording duration can be limited to a set number of days;
Default All (Green) Restore record settings to factory defaults.
Refresh (Purple) Refreshes the current page.
a set number of days. Set to ‘0’ to de-activate this function.
of preset recording proles. Select from Normal Rate-MPEG4 5pps,
Normal Rate-JPEG 1pps or Normal Rate-MultiMode recording.
allowing the recording quality to be enhanced for a shorter storage
period.
49
Page 50
Prole Record
It is possible to set the unit recording conguration based on specic priorities. The MultiMode recording
feature offers the ability to set different recording rates, resolutions and compression formats across unset,
set and override modes for each individual camera. By varying the quality, bit rate and le size of recorded
images, the MultiMode function enables the recording capabilities of the unit to be greatly increased.
Note: This page is only relevant if images are being recorded to the camera. If a DVR is being used,
recording direct to the camera may be disabled.
Simple Record
CamVu 500
50
Menu View Switch to the Advanced Prole Record menu.
Days Recording Displays the record duration possible using the current conguration.
Unset/Set/Override Normal Shows the recording prole used by the camera if no Timer Functions
are applied and the camera is operating under Normal (non Event)
conditions, refer to the ‘Schedules’ section for further details.
Unset/Set/Override Event Shows the recording quality that will be used by the camera during
an Alarm or Event. Note that Set and Override schedules will be used
only when Timed Schedules are applied, refer to the ‘Schedules’
section for further details.
Note: Unset, Set and Override modes may be renamed via Record Settings->Schedule.
Comp Select image compression format (MPEG, JPEG or H264).
PPS The accompanying dropdown list allows the number of frames
captured per second to be set.
The pictures per second (pps) option allows either 6, 5, 2, 1, 0.5, 0.25
or 0.1 pps to be recorded.
Pictures can also be recorded at 1/4, 1/2 or 3/4 Real Time.
To disable record, choose the ‘No Record’ option.
Select ‘User Dened’ to use settings established in the Advanced
Prole Record menu.
Quality The accompanying dropdown list allows the quality of recorded
images to be set. Select from Maximum, Very High, High, Medium, or
Low. Select User Dened to use settings established in the Advance
Prole Record menu.
Note: The higher the Quality setting, the greater the storage space needed.
Menu View Switch to the Simple Prole Record menu.
Note: When Advanced Record settings have been changed, it is not possible access the Simple
Record menu until the newly congured Advanced Record settings have been applied. To do
this, open the Record menu and select the ‘Save’ option. It will then be possible to return to the
Prole Record menu and access Simple Record.
Days Recording Displays the record duration possible using the current conguration.
Channel Displays the Camera Name.
Filter by Displays the Recording Settings.
Unset/Set/Override Normal Shows the recording prole used by the camera if no Timed
Schedules are applied and the camera is operating under Normal
(non Event) conditions, refer to ‘Schedule’ for further information.
Unset/Set/Override Event Shows the recording quality that will be used by the camera during
an Alarm or Event. Note that Set and Override schedules will be used
only when Timed Schedules are applied, refer to ‘Schedule’ for further
information.
Comp Select image compression format (MPEG, JPEG or H264).
Res Select image resolution format (VGA, QVGA, Q2VGA).
rate_kbps If MPEG4 is selected, the gure entered here will be the bit rate
allocated. A higher bit rate will provide better quality. MPEG bit rates
can be entered within the range of 45-2500K bits/second.
Size If JPEG is selected, the gure entered here will be the size of the
JPEG transmitted (in Kbytes). JPEG le sizes can be congured
within the range of 5-45Kbytes.
PPS Select the number of pictures recorded per second.
GOP If using MPEG4 recording, select the number of images recorded
within a GOP (Group of Pictures). A GOP consists of an I-Frame
(keyframe) and following P frames.
Refresh (Purple) Refreshes the current page.
This menu allows the unit to automatically protect and retain recorded data in the camera. Previously saved
data can also be unprotected. Enter a start and end time and select ‘Reload List’ . All saved video les from
the chosen time period will be shown in the upper textbox. These recorded ‘PAR’ les can then be selected
and protected via their accompanying checkboxes and the Protect option. Selected video les can also be
unprotected via the Unprotect option.
The lower textbox provides a status report detailing which video les have been protected/unprotected.
CamVu 500
54
Start Date Enter a start date to protect video.
Start Time Enter a start time to protect video.
End Date Enter an end date to protect video.
End Time Enter an end time to protect video.
Protect Length (days) Enter the number of days that selected les will be protected for.
Protect Select this option to protect recorded video for the selected
time period(s).
Unprotect Select this option to unprotect recorded video selected from
the list.
Reload List This will refresh the video list according to the selections made in the
Select None This de-selects all the available video les.
Select All This selects all the available video les.
List From Date/Time This dialog box allows a search to be made within the protected video
list starting from a specic Time and Date.
List To Date/Time This dialog box allows a search within the protected video list to
conclude at a specic Time and Date.
Refresh (Purple) Refreshes the current page.
This menu allows conguration of the units ATA over Ethernet (AoE) function. AoE is a network protocol
designed for simple high-performance access of storage devices over Ethernet networks. Importantly the
external storage device must be located on the same network as the unit. AoE does not rely on network
layers such as IP and TCP, making it non routable i.e. routers cannot be used to forward a packet across
disparate networks. AoE packets can only travel within a single local Ethernet storage area network (adds
a physical layer of security to the information). The stored video can only be accessed by plugging directly
into an ethernet socket in the same LAN as the host. This means AoE cannot be accessed over the Internet
or other IP networks, but makes AoE more lightweight (with less load on the host), easier to implement,
provides a layer of inherent security, and offers higher performance.
CamVu 500
56
Logical Devices Connected AOE Devices - Any devices in this panel are being used
by the unit to store data. They can be freed by clicking on the
Release button.
Physical Devices Available AOE Devices - Any devices in this panel are available on
the network. They can be added to the storage capability of this unit
by ‘claiming’ the storage. Unavailable storage is listed as Owned.
Claimed storage capacity can be ‘released’ in the top panel.
The Video Storage Allocation table displays drives that are available for video recording. Entries with the
prex ‘/HDD0’ indicate the units local hard drive (if installed), entries prexed by ‘/udd0’ are recordable media
connected to the unit via USB sockets (if tted), an entry prexed by ‘/mdd’ are installed SD cards.
CamVu 500
Device Entries with the prex ‘/HDDx’ (from 0 upwards) indicate the units
local hard drives (if installed), entries prexed by ‘/uddx’ (from 0
upwards) are recordable media connected to the unit via USB
sockets, an entry prexed by ‘/mdd0’ is the installed SD card.
Subsequent MDDx entries are for extra SD cards (where tted).
Size The device returns information when it is interrogated on connection
to the camera, the size of the recordable media is amongst this data.
Partitions The device returns information when it is interrogated on connection
to the camera, the number of partitions is amongst this data.
Allocate Formatted media can be allocated to the camera to allow it to be
used for recording. DM recommends that media is formatted before
allocation, even if if has been used previously for video storage.
Realm Displays the status of the associated media.
Feedback Displays messages about the progress of formatting/allocation of the
Format (Red) Prepares the media for video storage, refer to ‘To format additional
Stop Rec (Yellow) Suspends Recording on the unit
Clear Video (Blue) Wipes the video from the drive to disable playback.
Refresh (Purple) Refreshes the current page
To format additional Video Storage
1. Plug a USB storage device into one of the available USB ports and click the purple Refresh
button. The newly connected device will be displayed with a ‘/UDD’ prex. The SD card (if
installed) will also be displayed and can be allocated in the same way. USB devices will be
prexed ‘/UDD’, SD cards will be prexed ‘/MDD’.
2. The device may require formatting. DM recommends the device is formatted even if it was
CamVu 500
previously been used as video storage. Click on the ‘Format’ button adjacent to the device
listing to prepare the device for recording.
Video Storage’.
58
3. Allocate the formatted and mounted storage for video storage by clicking on the ‘Allocate’
button. Allocation takes between a few seconds and a few minutes, depending on the size of
the drive, and the Feedback column will display information about the allocation process. The
unit will require a Reset once allocation is complete.
Note: The unit application drive is protected, if it is allocated the unit will only remove the video folder.
Formatting any other device will remove all data. In either case recording on the system is
halted while formatting and, if already allocated, the formatted device will be de-allocated as a
video storage device
The system displays a conrmation box to ensure the correct device has been
selected. Click OK to conrm, then reboot the system. Once the power has cycled, the
system will build the required PAR les ready for recording to commence, progress will
be displayed in the Feedback column.
Note: There will be a pause before recording begins, dependant on the size of the USB device as
This menu allows the Timer Function names to be congured. The Timer Function enables the unit
to automatically be put into set/unset mode at specic times on specic days. This can help reduce
unnecessary alarm triggers. The mode can be set by the DVR that the camera is connected to.
When the unit is in Set or Unset mode, combine with different recording qualities and rates under normal
and alarm conditions for a high degree of control in a range of situations.
The Setup page allows conguration of the schedule including naming the modes of operation and
controlling when the unit changes between modes.
CamVu 500
The RVRC page allows a user to temporarily switch the unit’s system state into set/unset/
override mode.
This menu allows the Schedule function to be congured. This enables the unit to automatically be put into
set/unset mode at specic times on specic days. This can help reduce unnecessary alarm triggers.
Combining when the unit is in Set or Unset mode with different recording qualities and rates under normal
and alarm conditions gives a high degree of control in a range of situations.
CamVu 500
Mode/Title Enables a name to be entered for Unset, Set and Override mode.
Note: Any changes to Mode titles here will affect the mode names displayed in the Prole Record, IP
Record and Zone Input menu pages.
Current Mode Shows the current timer mode according to the names entered in the
Mode/Title text boxes.
Day Species which Day of the week is being congured
NOTE: The next two descriptions utilise the standard name settings for the proles (SET, UNSET).
If these names have been changed on this page, these menu options will display the user
congured names.
UNSET Time Species what time in format HH:MM the UNSET recording settings,
congured on the Prole Recording page, will become operational
SET Time Species what time in format HH:MM the SET recording settings,
congured on the Prole Recording page, will become operational
Note: The arrow button displayed next to each textbox allows settings to be replicated for those
cameras listed below. This will only affect the adjacent option i.e. Mode arrow will replicate the
Mode setting to all cameras below the clicked arrow.
Note: To disable one day, set both times to 00.00. To have the prole recording all 24 hours of a day,
This menu allows a user to temporarily switch the unit’s system state into set/unset/override mode. The user
will be required to enter their name and also the intended override duration. The action will be logged.
Note: Refer to the Schedule menu for details of how to congure Set, Unset and Override modes:
Record Settings->Schedule.
CamVu 500
Current System Time The unit’s current date and time information will be displayed. This will
be logged with any override action.
System GMT offset in mins Shows the number of minutes between the time in the time zone
congured for the unit and GMT.
Current timezone Displays the congured time zone for this unit, as set on the System-
>Time and Date page.
Current PC Time The current date and time information of the PC currently being used
to view the webpages will be displayed. This will be logged with any
override action.
PC GMT offset in mins Shows the number of minutes between the time as congured on the
connected PC and GMT.
Current system state The current system state will be displayed i.e. Set, Unset or Override.
Note: The system state names displayed here will depend on those entered via the Schedule menu:
Override duration (minutes) Enter a time period for the override procedure. After this time period,
Enter Your Name Enter your recognised user name. This will be logged.
Force UNSET(Green) Select to switch to Unset mode.
Force SET (Yellow) Select to switch to Set mode.
Force OVERRIDE (Blue) Select to switch to Override mode.
Refresh (Purple) Refreshes the information on the current page.
the system state will return to that congured via the Schedule menu
(for the current time).
This menu allows the conguration of established alarm zones. A single or multiple trigger can be used to
generate an alarm. It is possible to allocate up to 32 alarm zones to carry out a combination of actions. Use
these options in conjunction with the Zone Actions menu.
CamVu 500
66
Entry Time This is the number of seconds allowed for the user to enter the zone
and disable the alarms. If the alarm is not disabled within this period
the alarm will be triggered.
Exit Time This is the number of seconds from the alarm being set within which
the user must exit the set zone. If the user is still within the zone after
this time period the alarm will be triggered.
Zone An alarm zone can be established to logically groups alarms and
initiate actions when an alarm is activated, there are 32 congurable
zones.
Title This information is stored along with the relevant images in the
database, ensure this has relevance to the alarm zone.
Pre Alarm sec. This is the time period prior to the start of the alarm included with the
alarm recording for archive. These images will also be protected from
being overwritten.
alarm) that is protected from being overwritten. This time will include
the alarm trigger, the pulse extension and any post alarm recording. It
will not include pre-alarm images.
Select from Disk Low, Disk Full, Panic, Archiving Slow, Archiving
Fault, Virtual 1-16, and Keyword Channel 1 (which will trigger the
Alarm if any of the programmed keywords are detected).
used to trigger the zone alarm. This means an alarm trigger can be
received on the Zone Alarm Input or the Zone OR Input for the
zone to be activated.
The Zone AND Input identies that an alarm trigger needs to be
received on both the Zone Alarm Input and the Zone AND Input for
the zone to be activated and the alarm action to the
automatically initiated.
The unit will only issue the alarm actions if the trigger is received on
the zone alarm input and NOT on the Zone input.
any time and are to remain as programmed i.e. Panic Alarm. When
this is selected, the Set, Unset and Override options are disabled.
entry time is active. This is in compliance with BS8418 (the British
Standard for remote video reporting centres). Diverting from the entry
route during the countdown will result in the alarm being triggered
immediately. This allows staff entry without triggering an alarm prior to
switching the system to Unset mode.
exit time is active. This is in compliance with BS8418 (the British
Standard for remote video reporting centres). Diverting from the exit
route during the countdown will result in the alarm being triggered
immediately. This allows staff to exit without triggering an alarm.
will automatically start when the alarm is activated and ensure the
alarm system is not activated by other specied alarm triggers for the
Set time i.e. allowing a Guard to exit a building.
will automatically start when the ‘primary’ alarm trigger i.e. front door,
is actioned. This ensures the alarm system is not activated by other
specied alarm triggers for the set time
specic operation mode. Enable this for the zone alarm to be active in
Unset operation mode.
specic operation mode. Enable this for the zone alarm to be active in
Set operation mode.
CamVu 500
67
Page 68
Enable in Override Each alarm can be congured to be active when the unit is in a
Note: Unset, Set and Override modes can be given more recognisable titles i.e. Day, Night, Weekend
via the Schedule menu (Record Settings->Schedule).
Activity (Green) Select to open the Alarm->Activity menu
Zone Act (Yellow) Select to open the Alarm->Zone Actions menu
Alarm in (Blue) Select to open the Alarm->Inputs menu
Refresh (Purple) Refreshes the information on the current page
specic operation mode. Enable this for the zone alarm to be active in
This menu enables response conguration following activity trigger on the camera channel.
CamVu 500
VMD Pulse Extension The pulse extension extends the trigger period to avoid double
Channel Select the camera input for conguration from the drop down list.
Detection Type Each camera input can be congured for either ‘VMD’ or ‘Activity’
Note: Whichever Detection option is selected here, will result in the camera channel being only
available for editing in the relevant conguration menu i.e. if Activity is selected
only be edited for Detection in the Activity Setup menu and not the VMD Conguration menu.
Activity To Trigger Following Activity activation, select ‘Simple Response’ to trigger
Note: When Activity to Trigger is set to ‘Zone’; the options detailed below are unavailable.
Create Database Entry When selected, an alarm entry will be added to the Event database.
triggers of VMD occurring, i.e. If a second incident of VMD is
received, after the rst alarm is nished but within this period, the unit
will not create a new event.
detection. To assign no detection settings to the camera, select ‘None’
; this channel can
specic chosen responses from the options detailed below. Select
‘Zone’ to apply the Zone Input rules as congured in the Zone Input
menu, refer to ‘Zone Input’ for more information.
71
Page 72
Prole Change Select to enable the unit to switch from Normal to Event recording
Alarm Reporting This must be enabled for the unit to automatically connect
Alarm 24hr This will ensure that Activity Detection is permanently enabled on this
Add Still Image This will record a still image of the trigger along with the standard
Protect Alarm Images Select to automatically protect alarm images from
E-Mail Image This will email a still image (in JPEG format) of the VMD/Activity
CamVu 500
Enable in Unset This will enable Activity Detection when the unit is in Unset
Enable in Set This will enable Activity Detection when the unit is in Set
Enable in Override This will enable Activity Detection when the unit is in Override
Note: Unset, Set and Override modes can be given more recognisable titles i.e. Day, Night, Weekend
via the Schedule menu (Record Settings->Schedule).
Refresh (Purple) Refreshes the information on the current page
following alarm activation.
on alarm.
camera channel.
recording. This can then be sent on to an external destination.
being overwritten.
trigger to the email recipient as congured in the ‘E-mail’ menu
(Network Settings->E-mail)
The unit supports Activity Detection to enable the camera to automatically detect any movement/changes
within the video scene; this can trigger a number of operations such as FTP alarm notication and an
increase in recording rate. A still image of the selected camera will be shown in the Grid Editor screen. To
establish an Activity zone, edit the cells displayed across the image.
This option should be used in conjunction with the Zone Inputs and Zone Actions menus.
CamVu 500
Global Activity Mode Select ‘Always Active’ for Activity mode to be in constant operation.
Activity Channel Displays the images from the corresponding video source.
Activity Sensitivity This option allows the sensitivity setting to be established for the
activity grid being congured. There are ve settings to choose from:
Indoor High, Indoor Low, Outdoor High, Outdoor Low, Very Low.
Grid Editor Use the Grid Editor by placing cells in areas of the camera view
where movement will trigger an alarm by clicking the mouse on the
grid cells to enable/disable.
Reload Img (Red) This option will update the still image displayed in the Grid Editor.
Set All (Green) This option will insert a default square of 16 x 16 cells across the
displayed video image.
Clear All (Yellow) This option will clear all entered cells.
Refresh (Purple) Refreshes the current page.
Mode The zone mode identies when the reference image is taken for
triggering VMD. The options are:
Normal - The reference image is updated approx every
second. This will only allow small changes in the
scene without triggering
Last trigger - The reference image is only updated when the VMD
is triggered and is best used under controlled lighting,
i.e. so there are no false triggers due to ambient light
changes.
Static - The reference image is collected on startup and is
never updated. This would be used in ‘sterile’ areas
where there are no changes expected.
Zone disabled - This will disable the zone mode.
Pixel Count (%) This value is set as a percentage and equates to the percentage of
pixels in the selected zone that must change for the VMD event to be
triggered. The default setting is 20%.
Pixel Change (%) This setting is a percentage value of the overall change required
in the grayscale to be included in the pixel count. The percentage
change is dened over the complete range of black to white, a 100%
pixel change would be from black to peak white. The default setting is
20%.
Global Activity Mode This is set to Always Active when VMD is enabled.
Reload Image (Red) This will update the reference image to the latest view during
set up.
Clear All (Green) Removes all dened zones from the image.
Default Grid (Yellow) Displays the default 16 zone grid across the whole image.
Refresh (Purple) Refreshes the current page.
The Network Settings menus allow conguration of the unit’s network functionality. Key network settings
can be established such as ‘xing’ the unit’s IP address and maximum transmission rate. E-mail, remote
reporting on alarm and FTP download can also be congured, refer to the individual menus for
further details.
The Network page allows conguration of the unit’s network connections such as the name assigned to the
unit and its IP address.
The Live Trans(mission) page enables JPEG and MPEG proles to be created for transmitting images via a
High, Medium or Low quality network connections to any viewing software or to another unit using this one
CamVu 500
as an IP source.
The Multicast page allows recordings from the unit’s camera input to be forwarded to a port address;
enabling multiple viewers to view live data using a suitable media player without the need to directly connect
to the unit.
The Email page allows conguration of the Email feature. The unit can automatically transmit an e-mail to an
SMTP Server following an event i.e. on receipt of an alarm or a camera failure notice.
The Remote Reporting page allows a Remote Video Receiving Centre’s (RVRC) conguration details to be
entered. The RVRC will then be contacted following a selected event occurring i.e. reported alarm or
camera failure.
The Web Cam page allows the video input to be made available for transmission to a webserver via a
designated webcam server. The image can then be incorporated into a web page and accessed via a
standard web browser.
The FTP Download page allows data to be archived to a central FTP server. This could be on receipt of an
alarm, Activity activation or at a scheduled time to back-up recorded video.
The Firewall page allows conguration of the onboard rewall.
The Connections page displays the current live connections to the unit.
This menu allows network settings to be congured if required. The unit is DNS compliant, and can be
referenced on the network using the congured server name (or serial number) if a DNS server is available .
CamVu 500
Server Name This eld can be edited to allocate a name to the unit. This would be
used if accessing the unit via a Domain Name Server (DNS). It will
initially default to the serial number of the unit.
IP Address An IP address can be manually allocated to the unit.
Sub Net A Subnet address of the unit network can be manually allocated.
Gateway This is the IP address of the default gateway (router).
Primary DNS This is the primary DNS server IP address for applications utilising
domain names.
DHCP If DHCP is being utilised, the assigned IP address will be
displayed here.
Note: If no IP address is manually congured, DHCP will automatically assign one. The unit
interrogates the network for a DHCP server, which assigns an available IP address. This
IP address can change every time the unit is powered up. If DNS is not available, it is
recommended that DHCP be disabled by entering a suitable, free, static IP address.
Tip: Use DHCP to locate a free IP address, then x the unit IP address to the free one by entering
the details into the IP address, subnet and gateway elds.
Max Transmission Rate kbits/sec This shows the maximum transmission speed for the network type
Note: This setting will limit and override any higher transmission rate entered in the Video
Transmission menu (Conguration menu->Live Trans).
Force 10BaseT operation The unit supports 10 or 100BaseT half duplex transmission. Selecting
Tx Image Buffers This is used in order to improve the picture delivery over Ethernet
Ethernet MTU Bytes This is the maximum transmit unit for the Ethernet packet. The MTU
CamVu 500
Max Transmission Timeout ms This is the time (in milliseconds) the unit will wait to re-send a packet
Reset (Red) Resets the unit to apply changes.
Rem Report (Green) Opens the Network Settings->Remote Reporting page.
Webcam (Yellow) Opens the Network Settings->Web Camera Conguration page.
Email (Blue) Opens the Network Settings->Email page.
Refresh (Purple) Refreshes the current page.
being used. If set to ‘0’, transmission speed is not limited in the
camera.
this option will force the unit to operate at a 10BaseT connection.
when using a slow connection i.e. 256Kbps. A buffer setting of 1,2 or
3 is available (default setting is 1).
is the largest physical packet size measured in bytes that the network
can transmit. By default this gure is set to 1500bytes.
This shows the transmission settings congured for a High quality
LAN (Local Area Network) connection, Medium quality WAN (Wide
Area Network) connection or a Low quality VLBR (Very Low Bit
Rate connection).
(VGA, QVGA, Q2VGA).
(in Kbytes).
provide better quality picture display.
79
Page 80
PPS This shows the number of pictures transmitted per second.
MPEG Type & Quality Select whether transmitted MPEG4 images are sent as RAW data or in
CamVu 500
CBR maintains a Constant Bit Rate, selectable from a range of 2 - 31.
I Frame Ratio Select the ration of I Frames recorded between each P Frame
Note:An MPEG I-frame is considerably larger than a P-frame. Therefore
Refresh (Purple) Refreshes the current page.
For JPEG, the actual images transmitted will depend on the bandwith
of the link, increasing the pictures sent per millisecond may introduce
time lag if bandwith is not sufcient i.e. this forces the same quality
image through the available connection.
On MPEG transmission, increasing the pictures sent will also reduce
the quality of the images i.e. this forces more images but maintains
the dened bit rate.
GOV (Group of Video) format.
RAW mode transmits a single I frame and then a sequence of P frames
(until a change in transmission is detected).
GOV mode sends I and P frames in a standard format i.e. I to P frame
ratio as set by the record parameters.
Select a suitable level of details from the drop down list. Constant Bit rate
allows the storage requirements to be calculated with more accuracy.
the higher the I-P ratio, the higher the disk space required to store
recorded images.
The Multicast page allows live images from the unit to be forwarded to a port address; enabling multiple
viewers to view live video using a suitable media player without the need to directly connect to the unit. In
multi viewing scenarios, the demands on the unit are signicantly reduced; improving
overall performance.
This system has been validated using the ‘Videolan VLC media player for MS Windows.
The Videolan VLC media player can be downloaded free of charge from:
www.videolan.org/vlc/download-windows.html
Note: Multicast can only used for live viewing, requests for stored images and events will still need to
be made via the Viewer menu.
CamVu 500
Multicast Address Assign a unique IP address. This address is not assigned to any
‘physical’ unit. The VLC program will use this address (when
congured to do so) as its multicast group and access any broadcast
images via the congured port address (see below).
If there are multiple units using multicast, each one must have a
unique IP address.
Multicast port Following conguration of the IP address, congure the port address.
Multicast Method Select from ‘SAP’, ‘HTTP’, ‘SAP + HTTP’ or ‘Always On’. SAP is
SAP will advertise your stream over the network when using the
HTTP will stream by using the HTTP protocol on all the network
Enable Tick this option to enable multicast.
TTL (Time to Live) This sets the numbers of routers the stream will be allowed to pass
CamVu 500
0 - restricts video to the same host
1 - restricts video to the same subnet
32 - restricts video to the same site
64 - restricts video to the same region
128 - restricts video to the same continent
255 - is unrestricted in scope
recommended.
UDP streaming method, using the SAP protocol, using the Multicast
Address as the name of the stream.
interfaces of the server on port 8080.
through, for UDP unicast and unicast access methods.. Enter one of
the following numbers:
To congure your PC to utilise VLC with SAP Multicasting
Version 1.0.5
* Select Media -> Services Discovery -> SAP Announcements
* Select View -> playlist -> SAP Announcements
* All video servers with multicast enabled should then appear in the playlist window. Double click
a server to start streaming data from it.
Version 0.8.6
* In VLC select Playlist -> Manage -> Services Discovery -> SAP Announcements
* Wait for the server to appear under “Session Announcements (SAP)” in the Playlist window.
* Click on one of the items advertised by the server.
* The server broadcasts SAP announcements periodically, the packets contain SDP entries
which describe the stream contents for each multicast enabled camera. VLC listens for SAP
announcements and adds them to the playlist.
The unit can automatically transmit an email to an SMTP Server under numerous conditions i.e. on start
up, on receipt of an alarm, camera failure etc. This allows the unit to be installed in unmanned applications
where a Remote Video Response Centre (or Manager etc.) would be notied by email if any of these
conditions occur.
CamVu 500
Connection Prole It is possible for the e-mail to be transmitted via the Ethernet network
or dial up connection (PPP ‘Point to Point Protocol’). This setting
presumes that a modem has been connected or congured and the
unit is connected to a LAN or WAN and allocated a valid IP address.
Mail Server Address This is the IP address or URL of the SMTP Server that the e-mail will
be sent to. The SMTP server will then forward this to the intended
recipient.
Username Enter the login details for the email account used above.
Password Enter the login details for the email account used above.
Recipient Email This is the e-mail address of the intended recipient.
Recipient Display Name This is the addressee name that will be shown in the e-mail
Reply to E-mail This eld must be congured if the recipient is to reply to an e-mail.
Reply To Display Name
Sender E-mail These optional elds indicate the source of the e-mail notication. If
Sender Display Name
Send on Startup Select to send e-mail notication on startup.
Send on Alarms Select to send e-mail notication on alarm activation.
Send on Camera Fail Select to send e-mail notication on camera fail.
CamVu 500
Send on Activity Event Select to send e-mail notication on activation of the Activity Detection
Send Image Select to send accompanying image from supporting
E-mail Image Res Select resolution settings for images sent as ‘thumbnail’ attachments.
Log E-mail Select to log every e-mail transaction that the unit issues.
Test E-mail (Red) Select to send a test e-mail to the congured recipient.
Zone Act (Green) Select to open the Alarm->Zone Actions menu
Network (Yellow) Select to open the Network->Network menu
Rem Reporting (Blue) Select to open the Network->Remote Reporting menu
Refresh (Purple) Refreshes the information on the current page
The unit does not accept incoming emails therefore ensure this is a
valid e-mail address.
This is the ‘reply to’ name that will be shown in the e-mail name eld.
the elds are left blank the unit will use the system name to create a
sender name.
This is the sender name that will be shown in the e-mail name eld.
feature.
primary camera.
Choose from: Thumbnail, LO (low res), MED (medium res) and HI
(high res).
Public (NAT) Address This is the public IP (or domain name) for a unit connected to the
Video Server Port This eld allows the RVRC to connect to the unit through a router that
Alarm Server ref. ID This is the reference name/ID that will be presented to the RVRC
Remote alarm Reporting This must be enabled for the unit to automatically connect
CamVu 500
Remote camfail Reporting Enabling this option ensures the unit reports camera failure on any of
Remote Startup Reporting This will send an alarm report when the unit starts up. Any system
ARC Ping Enabled
Alarm responder port This species the network port number used for reporting to the alarm
Dial retry time (secs) If the initial connection attempt fails, the unit will wait for the specied
Dial count This identies the number of times the unit will attempt to connect
Zone Act (Green) Select to open the Alarm->Zone Actions menu
Network (Yellow) Select to open the Network->Network menu
E-mail (Blue) Select to open the Network->E-mail menu
Refresh (Purple) Refreshes the information on the current page
Internet via a NAT Router or Firewall. This eld should be left blank if
NAT is not used e.g. a private network.
is using port forwarding e.g. if the camera does not appear on port
80 (HTTP), to the external network. Enter the port number used for
forwarding here if required.
viewing application. It should therefore have some signicance to the
Operator.
on alarm.
the inputs to the RVRC.
resets will be identied.
Should the modem/router at the Alarm Receiving Centre be dormant, the
unit will ‘ping’ the ARC prior to sending reporting data.
server. In normal circumstances this should be left at the default value
(23).
time period (in seconds) before attempting to re-connect.
after a failed attempt. A setting of ‘0’ means no limit and the unit will
continue to try and connect until successful.
Any of the video inputs on the unit can be made available for transmission to a webserver via a designated
webcam server. These images can then be incorporated into a web page and accessed via a standard web
browser.
Note: This menu will only be displayed if ‘Webcam Support’ is selected in the
System Settings->Features menu.
CamVu 500
Server URL This is the IP address, URL or Domain Name of the WEBCAM Server.
Images will be uploaded from the unit to this server at specied time
intervals.
Disable ICMP Discovery When enabled, the unit will not attempt to ‘Ping’ the congured
webserver but will begin immediate data transfer.
Root Directory This is the main/root directory on the webcam server where the
image directory will be located.
Image Directory This directory will be created when the initial image is uploaded to the
webcam server, it is the directory where all images will be saved on
the server.
Image Filename Prex This is an identier for images sent from the unit and will be stored as
The unit can archive images to a central FTP (File Transfer Protocol) server. This could be on receipt of an
alarm, activation of the Activity Detection or at a scheduled time to backup recorded video. Using FTP in a
multi-unit application ensures that all les are stored in one central location for each of the units, offering
efcient le management and easy review capabilities.
CamVu 500
FTP Server IP URL or name
FTP Control Port The default port for FTP use is port 21. If this port has
Status Server Port Default The default port for the Server Status function is port 23, if this port
FTP Root Drive and Directory
Username If it is necessary to use an authentication process to access the FTP
This page allows conguration of the on-board rewall. The top ports are pre-congured with typical settings
that can be edited, there are user dened ports available at the bottom of the list. Precongured ports can be
disabled by unchecking the ‘open’ box.
CamVu 500
Enable PING response By default this option is enabled and allows the unit to be pinged.
Disabling this option will make the unit less visible on the network
Table Entry Up to 32 Conguration settings may be entered.
Service Name Details the assigned name of the service using the opened port on
the rewall.
Port Start Displays the start of the port range used by the service
Port End Displays the end of the port range used by the service
Note: To open a single port, enter the same number in the Port Start and Port End boxes.
Type Displays the type of port to open, select from TCP or UDP.
Open Displays if the port is open or not. Closing a port activates the rewall.
Refresh (Purple) Refreshes the current page
Dedicated Micros has created a range of analytics components and solutions designed to work with
AnalyticsCapable products. The range of applications include: Automatic Number Plate Recognition (ANPR),
Object Left and Removed, Access Control, People Counting and Perimeter Protection.
CamVu 500
94
•For further information regarding the range of Dedicated Micros Analytics solutions,
please call: + 44 (0) 845 600 9500
The Activate New Feature menu allows new AnalyticsCapable licenses to be added to your unit. It details
the Features System Code that Dedicated Micros Customer Services require to provide the Activation Code.
Also detailed are all advanced features currently activated on the unit (and the maximum number of each
type of license allowed).
CamVu 500
Currently Active Features Any advanced features currently installed on the unit will be detailed
here.
Type The available variants of feature licenses will be listed.
In Use The total number of each license type currently installed on the unit
will be displayed.
Maximum This shows the maximum amount of each license type that can be
installed on the unit.
Features System Code This code must be provided to the Dedicated Micros Customer
Services team (Tel +44 (0) 845 600 9501) to obtain your Activation
code. On receipt of this information, DM will provide you with your
Activation code.
License Key Enter the License key details here. The License key will be provided
by Dedicated Micros Customer Services team.
Activation Code Enter the Activation Code details here.
Note: Both the License Key and Activation Code are case sensitive. Be careful to differentiate
between number ‘0’ and letter ‘O’.
Note: Navigate to System Settings->PowerScript Mgmt to view DM PowerScript software currently
active on your unit (and limit which scripts will automatically run at start-up). When any
AnalyticsCapable licenses have been activated, the ‘analytics.c’ option must remain checked
for the feature(s) to operate correctly.
IMPORTANT: For AnalyticsCapable features to function correctly, the ‘Enable Keyword’ function
Reset (Red) Select to reset the unit.
Refresh (Purple) Refreshes the information on the current page
must be enabled on the unit.
● Navigate to the ‘System Settings->Features’ menu and ensure the ‘Text In Image’
option is selected.
● Navigate to the ‘Features & Text->Text In Image’ menu. Set the Enable Keywords
option to ‘Enable’.
Page 97
Text In Image
It is possible to integrate the unit into a system were text information can be stored with relevant images for
review. This would be most useful in a Retail or Finance application were text data originating from a cash
register could be displayed in real time with the video images of the same Point of Sale.
Note: This menu will only be displayed if ‘Text in Image’ is selected in the
System Settings->Features menu.
CamVu 500
Recorded lines per frame This controls how many lines of text are stored on the server, and
not how many are displayed on screen. This allows more data to be
saved than is shown.
Recorded characters per line Controls the width of the lines displayed on screen.
Text Timeout This setting controls how long, in seconds, the text is shown onscreen
(selecting 0 will show the text indenitely).
Channel Select the camera input for conguration from the drop down list.
Text Port Type Select the input source for Text in Image data. Select ‘Off’ to switch
the function off or ‘Network to use the unit’s Network port
Text Filter Select the text lter option from the drop down list. The options are:
Plain Text (default), RAW, EPSON, Laserjet, DM POS Receipt, DM
Enable Keywords This enables or disables the Keyword feature, allowing the unit to
Keywords pulse extension This time period allows multiple instances of a word received within
Reset Resets the unit to apply changes.
Zone Act (Green) Opens the Alarm Settings -> Zone Actions page.
Keywords (Yellow) Opens the Features & Text -> Text -> Keywords page.
CamVu 500
Refresh (Purple) Refreshes the current page
treat certain pre-programmed words received via the text stream as
event triggers, refer to ‘Keywords’ for guidance on creating Keyword
triggers.
a period of time to be treated as a single event (i.e. if a congured
Keyword is detected again within the rst Keyword’s pulse extension
period, the second (and following) occurrences of the word will be
ignored).
This menu allows a specic keyword received via the text stream to be congured and enabled as an event
trigger. The ‘Enable Keyword’ function needs to be activated in the ‘Text in Image’ menu for this feature
to operate.
CamVu 500
Text Keyword The unit can be congured to react to a keyword appearing in text
data and treat it as an alarm zone input. In turn this generates events
in the event database. The keyword can be up to 20 characters in
length. The keyword will be active on the selected Zone keyword
channel, refer to “Zone Input -> Input”.
Note: Refer to ‘Text In Image’ for further guidance on integrating text data.
The Diagnostics menus gives engineers the ability to quickly and accurately diagnose any problems with the
unit. This menu will normally only be used on a Technical Support call.
The Debug Parser menus allow detailed analysis of the debug output from the camera and maybe used to
assist with fault nding. The debug can be ltered in order to isolate and highlight events that are of interest.