64
CamVu 720
Alarm Protect sec. This is the minimum time period in seconds (from the start of the alarm)
that is protected from being overwritten. This time will include the alarm
trigger, the pulse extension and any post alarm recording. It will not
include pre-alarm images.
Zone Input Rule This determines which input(s) will trigger the zone alarm:
Input This sets an input or system function as the primary alarm trigger.
Select from Disk Low, Disk Full, Panic, Archiving Slow, Archiving Fault,
Virtual 1-16, and Keyword Channel 1 (which will trigger the Alarm if any
of the programmed keywords are detected).
Zone OR Input The Zone OR Input identies an alternative input that can also be used
to trigger the zone alarm. This means an alarm trigger can be received
on the Zone Alarm Input or the Zone OR Input for the zone to be
activated.
Zone AND Input
The Zone AND Input identies that an alarm trigger needs to be
received on both the Zone Alarm Input and the Zone AND Input for
the zone to be activated and the alarm action to the
automatically initiated.
Zone NOT Input
The unit will only issue the alarm actions if the trigger is received on the
zone alarm input and NOT on the Zone input.
Alarm 24hr This option can be enabled for alarms that do not require change at any
time and are to remain as programmed i.e. Panic Alarm. When this is
selected, the Set, Unset and Override options are disabled.
Entry Route Zone This creates deferred alarms along a specied route while the
entry time is active. This is in compliance with BS8418 (the British
Standard for remote video reporting centres). Diverting from the entry
route during the countdown will result in the alarm being triggered
immediately. This allows staff entry without triggering an alarm prior to
switching the system to Unset mode.
Exit route Zone This creates deferred alarms along a specied route while the exit time
is active. This is in compliance with BS8418 (the British Standard for
remote video reporting centres). Diverting from the exit route during
the countdown will result in the alarm being triggered immediately. This
allows staff to exit without triggering an alarm.
Exit Terminator This will trigger the exit timer if the system is set. A countdown timer will
automatically start when the alarm is activated and ensure the alarm
system is not activated by other specied alarm triggers for the Set time
i.e. allowing a Guard to exit a building.
Entry Initiator This will trigger the entry timer if the system is set. A countdown timer
will automatically start when the ‘primary’ alarm trigger i.e. front door,
is actioned. This ensures the alarm system is not activated by other
specied alarm triggers for the set time
Enable in Unset Each alarm can be congured to be active when the unit is in a specic
operation mode. Enable this for the zone alarm to be active in Unset
operation mode.
Enable in Set Each alarm can be congured to be active when the unit is in a specic
operation mode. Enable this for the zone alarm to be active in Set
operation mode.
Enable in Override Each alarm can be congured to be active when the unit is in a specic
operation mode. Enable this for the zone alarm to be active in Override
operation mode.
Note: Unset, Set and Override modes can be given more recognisable titles i.e. Day, Night, Weekend
via the Schedule menu (Record Settings->Schedule).
Activity (Green) Select to open the Alarm->Activity menu
Zone Act (Yellow) Select to open the Alarm->Zone Actions menu