16 Way 485 Bus Relay Module
Setup and
Operation Guide
Page 2
Contents
Introduction ................................................................3
Installation ..................................................................4
Setting the 485 Bus Address .....................................5
Specication ..............................................................6
485 Bus Relay Module
2
or modify the specication of the machine described herein without prejudice.
Dedicated Micros ©2011
Page 3
Introduction
The remote alarm module allows additional alarms to be connected to Dedicated Micros DVR’s and DV-IP products.
The additional alarm outputs are congured within the system menus. This allows integration of building management systems into a single solution, ensuring the site is continuously monitored and recorded (if enabled).
Compatible DM Products
The DM/485ALO16 alarm module can be included in installations that have one or more of the following DM products:
DV-IP Server (Gen3)
DV-IP Express
DV-IP RT
DV-IP HD
SD
SD Advanced
Note: Software version 4.3(26.31) or later is required
Note: This product is not compatible with the DS2, DV-IP (Gen2), BX2 or Multiplex units.
Note: DV-IP Gen3 and SD products use RJ12 connections. Previous products use MML
connectors (identiable by the offset retaining clip).
485 Bus Relay Module
Dedicated Micros ©2011
3
Page 4
Installation
A
Relay Module Diagram
A - Address Links (J1/J2)
B - Remote Power twisted pair data transmission (F12)
C - Local 12V power supply (PS)
MMJ
MMJ
P8
P7
J2 J1
RLY16
P8
CM16
P9
P10
P11
RLY15
CM15
RLY14
CM14
RLY13
CM13
RLY12
CM12
RLY11
CM11
RLY10
CM10
RLY9
CM9
J3
IC2
IC13
485 Bus Relay Module
RLY1
P1
CM1
RLY2
CM2
RLY3
P2
CM3
RLY4
CM4
RLY5
P3
CM5
RLY6
CM6
RLY7
P4
CM7
RLY8
CM8
J3
P12
GND RSB RSA PWRIN PWRIN GND
J4
P5
B
LINK CONNECTION FUNCTION DEFAULT
J1 Pins 1 - 8 485 Bus Address Link NOT FITTED J2 Pins 1 & 2 485 Bus Address Link NOT FITTED Pins 3 & 4 FITTED Pins 5 & 6 NOT FITTED Pine 7 & 8 FITTED J3 Pins 1 & 2 Manual Reset NOT FITTED J4 Pins 1 & 2 485 Bus Termination NOT FITTED J5 Pins 1 & 2 Supply PWR to Board from P12 NOT FITTED
RLY1
CM1
RLY2
CM2
C
CONNECTOR CONNECTION FUNCTION
P5 Pin 1 PWR IN GND
Pin 2 PWR IN +9Vd.c.
P12 Pin 1 Remote PWR IN Pin 2 485 Bus Data ‘A’/485 POS
Pin 3 485 Bus Data ‘B’/485 NEG
Pin 4 Remote PWR IN GND
4
Dedicated Micros ©2011
Page 5
Setting the 485 Bus Address
The 485 bus relay module must be assigned an address on the 485 bus network to ensure each device on the network can communicate with it.
This address can be anywhere within an allocated range (160 - 175). Links are added to J1 and J2 to set the address, as detailed in the table below.
Relay Status of Status of Address Module Link Settings J1 Link Settings J2 1 & 2 3 & 4 5 & 6 7 & 8 1 & 2 3 & 4 5 & 6 7 & 8 A B C D A B C D 1 0 0 0 0 0 1 0 1 160 2 1 0 0 0 0 1 0 1 161 3 0 1 0 0 0 1 0 1 162 4 1 1 0 0 0 1 0 1 163 5 0 0 1 0 0 1 0 1 164 6 1 0 1 0 0 1 0 1 165 7 0 1 1 0 0 1 0 1 166 8 1 1 1 1 0 1 0 1 167 9 0 0 0 1 0 1 0 1 168 10 1 0 0 1 0 1 0 1 169 11 0 1 0 1 0 1 0 1 170 12 1 1 0 1 0 1 0 1 171 13 0 0 1 1 0 1 0 1 172 14 1 0 1 1 0 1 0 1 173 15 0 1 1 1 0 1 0 1 174 16 1 1 1 1 0 1 0 1 175
485 Bus Relay Module
Dedicated Micros ©2011
5
Page 6
Specication
Switching voltage 200 Volts
Switching current 0.5 Amps
Carry current 1.5 Amps
Switching frequency 500 Hz
Contact resistance 120 mΩ
485 Bus Relay Module
6
Dedicated Micros ©2011
Page 7
Index
Compatible DM Products............................................................................................................................... 3
Contents ........................................................................................................................................................ 2
Installation .....................................................................................................................................................4
Introduction .................................................................................................................................................... 3
Relay Module Diagram ..................................................................................................................................4
Setting the 485 Bus Address .........................................................................................................................5
Specication .................................................................................................................................................. 6
485 Bus Relay Module
Dedicated Micros ©2011
7
Page 8
Dedicated Micros Ltd.
1200 Daresbury Park, Daresbury,
Cheshire, WA4 4HS, UK
Dedicated Micros Europe
Neckarstrafle 15,
41836 Hückelhoven, Germany
Dedicated Micros France
9-13 rue du Moulinet
75013 Paris, France
Dedicated Micros Slovenia
Delavska cesta 26,
4208 Sencure, Slovenia
Dedicated Micros Benelux
Joseph Chantraineplantsoen 1,
3070 Kortenberg, Belgium
Dedicated Micros USA.
14434 Albemarle Point Place, Suite 100,
Chantilly, Virginia 20151 USA
Installed by
Dedicated Micros USA. 23456 Hawthorne Blvd.
Suite 100, Torrance,
CA 90505, USA
Dedicated Micros, Australia PTY.
5/3 Packard Avenue, Castle Hill,
NSW 2154, Australia
Dedicated Micros, Asia PTY
16 New Industrial Road,
#03-03 Hudson Techno Centre,
Singapore 536204
Building 12, Suite 302, P.O. Box 500291, Dubai Internet
Dedicated Micros Middle East
City, Dubai, United Arab Emirates
Dedicated Micros (Malta) Ltd.
BLB017, Bulebel Industrial Estate,
Zejtun, ZTN3000, Malta
MI-I-485AO/E1-1
Loading...