1 Basic safety advice
The handling of the appliance technology is only allowed for instructed staff. The exact knowledge of the guide book is an important condition for the staff before handling the machine.
Please keep the instruction manual close to hand and available for everybody. deconta has to engage you as the user to follow the guide book and to employ this engineered technology only in accordance with the regulations and not in a inappropriate way! In the event of non-observance, deconta assumes no liability.
To ensure safety during operation of the unit, the following must be strictly observed:
Do not use in potentially explosive areas. Necessary repairs and maintenance may only be performed by authorized staff.
For all repair and maintenance work, the device is to be completely disconnected
from power supply
The safety and protective equipment is to be kept in perfect function.
Attached safety guidelines are to be kept in a readable state and are to be followed.
Generally applicable legal and other binding regulations for accident prevention
and handling of hazardous substances must be observed.
In order not to restrict safety, any changes on the machine are prohibited.
Instruction manual Water treatment boiler system D 110 L
Seite 4
2 Transport und storage
2.1 Delivery
The unit is delivered on a pallet. To prevent effects of weather or damages, the unit is wrapped in a plastic film. Transport damages have to be documented at once during the handing over of the carrier or another supplier. Please note the possible damages additionally on the way bill.
2.2 Transport The Transport has to be handled with care to avoid damages due to faulty handling or
imprudence. In winter and at risk of frost, you have to empty the whole device (pumps, filter housings, tank.) preliminary to the transport.
Attention: Transport of the machine (also change of location) only with a drained device.
2.3 Storage
In order to avoid damages, the installation has to be kept in a dry area with no access for unauthorized persons.
Because of risk of frost in winter you have to observe the following:
Empty water pipes, filter housing and tank Place the water treatment system in a place protected against frost.
Advice for the draining of the tank: In order to drain, move the ball valve.
Instruction manual Water treatment boiler system D 110 L
Seite 5
3 Volume of delivery
The volume of delivery of a water treatment boiler system, unless no other agreements have been made, consists of:
Water treatment system D110l Filter set Instruction manual
Return delivery after termination of rental period
We have to insist on following conditions for the return delivery in order to protect our clients and in accordance with the rules for hazardous materials transportation:
As listed above Well cleaned (ready for use) Without binder remains Without damages Without filter
4 Technical description
4.1 Use according to regulations
During asbestos sanitation works within closed rooms, you have to exclude that the asbestos fibres leave the sanitation area uncontrolled and endanger the human health and the environment. For this reason, personnel must leave the sanitation area through a lock system and take a shower while leaving.
The deconta water treatment assumes the heating of the shower water and takes over the filtering of the contaminated sewage water.
4.2 Unit description
This is an electric warm water storage for the heating of shower water. The tank can be filled optionally via the filling port (bucket) or automatically over a connected fresh water hose. The water is heated to shower temperature (factory-adjusted approx. 37°C) by an electric heating rod. The produced shower water is pumped out via an internal pump and filtered.