Decagon Devices ProCheck Operator's Manual

Operator’s Manual
Decagon Devices, Inc.
Version: July 30, 2014 — 11:39:36
ProCheck
Decagon Devices, Inc.
2365 NE Hopkins Court
Phone: 509-332-5600
Fax: 509-332-5158
Website: www.decagon.com
Email: support@decagon.com or sales@decagon.com
Trademarks:
ProCheck is a registered trademark of Decagon Devices, Inc.
All Rights Reserved
c
2007-2014 Decagon Devices, Inc.
All Rights Reserved
ii
ProCheck CONTENTS
Contents
1 Introduction 1
1.1 Customer Support . . . . . . . . . . . . . . . . . . . . 1
1.2 About This Manual . . . . . . . . . . . . . . . . . . . 1
1.3 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.4 Seller’s Liability . . . . . . . . . . . . . . . . . . . . . . 2
2 About the ProCheck 3
2.1 Specifications . . . . . . . . . . . . . . . . . . . . . . . 3
2.2 The Buttons . . . . . . . . . . . . . . . . . . . . . . . 4
3 The Menus 5
3.1 The Main Menu . . . . . . . . . . . . . . . . . . . . . . 5
3.2 The Configuration Menu . . . . . . . . . . . . . . . . . 6
3.2.1 Custom Calibrations . . . . . . . . . . . . . . . 11
3.3 SDI-12 Address Menu . . . . . . . . . . . . . . . . . . 13
3.4 The Data Menu . . . . . . . . . . . . . . . . . . . . . . 15
3.4.1 Statistics . . . . . . . . . . . . . . . . . . . . . 17
3.5 Erasing Data Memory . . . . . . . . . . . . . . . . . . 18
4 ECH2O Utility Software 20
4.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . 20
4.2 Connecting to your ProCheck . . . . . . . . . . . . . . 20
4.3 Saved Data File Types . . . . . . . . . . . . . . . . . . 21
4.4 Data File Options . . . . . . . . . . . . . . . . . . . . 23
4.5 More ECH2O Utility Options . . . . . . . . . . . . . . 24
4.6 Test Device Firmware . . . . . . . . . . . . . . . . . . 24
4.7 Check for Device Firmware Updates . . . . . . . . . . 24
5 Troubleshooting and Repair 25
5.1 Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
6 Appendix A 31
6.1 Compatible Sensors . . . . . . . . . . . . . . . . . . . . 31
7 Appendix B 33
7.1 Sending Feedback . . . . . . . . . . . . . . . . . . . . . 33
8 Declaration of Conformity 35
iii
ProCheck 1 INTRODUCTION
1 Introduction
Thank you for purchasing the ProCheck by Decagon Devices. The ProCheck interfaces with your analog and digital soil moisture sen­sors to obtain instantaneous results. This manual covers all ProCheck functions and capabilities.
1.1 Customer Support
There are several ways to contact Decagon if you ever need assis­tance with your product, have any questions, or feedback. Decagon has Customer Service Representatives available to speak with you Monday through Friday, between 7am and 5pm Pacific time.
Note: If you purchased your logger through a distributor, please con­tact them for assistance.
Email: support@decagon.com or sales@decagon.com
Phone: 509-332-5600
Fax: 509-332-5158
If contacting us by email or fax, please include as part of your mes­sage the instrument serial number, your name, address, phone, fax number, and a description of the problem or question.
1.2 About This Manual
Please read this manual before operating your logger to ensure that it performs to its full potential.
1
1 INTRODUCTION ProCheck
1.3 Warranty
The ProCheck has a 30-day satisfaction guarantee and a one-year warranty on parts and labor. Your warranty is automatically vali­dated upon receipt of the instrument.
Note: The one year service plan activates when Decagon ships the instrument and not at the time of software installation.
1.4 Seller’s Liability
Seller warrants new equipment of its own manufacture against de­fective workmanship and materials for a period of one year from the date of receipt of equipment.
Note: We do not consider the results of ordinary wear and tear, neglect, misuse, or accident as defects.
The Seller’s liability for defective parts shall in no event exceed the furnishing of replacement parts “freight on board” the factory where originally manufactured. Material and equipment covered hereby which is not manufactured by Seller shall be covered only by the warranty of its manufacturer. Seller shall not be liable to Buyer for loss, damage or injuries to persons (including death), or to property or things of whatsoever kind (including, but not without limitation, loss of anticipated profits), occasioned by or arising out of the instal­lation, operation, use, misuse, nonuse, repair, or replacement of said material and equipment, or out of the use of any method or process for which the same may be employed. The use of this equipment con­stitutes Buyer’s acceptance of the terms set forth in this warranty. There are no understandings, representations, or warranties of any kind, express, implied, statutory or otherwise (including, but with­out limitation, the implied warranties of merchantability and fitness for a particular purpose), not expressly set forth herein.
2
ProCheck 2 ABOUT THE PROCHECK
2 About the ProCheck
The ProCheck is a handheld readout device for use with all soil moisture sensors and environmental monitoring sensors made or sold by Decagon.
2.1 Specifications
Battery Type: 4 AA Batteries Battery Life: 500-1000 Hours Expected Connector Type: Stereo Plug (3.5mm) Memory: 5000 individual readings
Components
ProCheck Handheld Reader Serial (RS-232) to USB Cable Operator’s Manual Optional - Pigtail Adapter
3
2 ABOUT THE PROCHECK ProCheck
2.2 The Buttons
Menu: Menu turns on the ProCheck and cy­cles through the menus at the top of the screen. Holding Menu down for 3 seconds powers off the ProCheck. Pressing Menu in an annotation/edit screen returns you to the previous screen.
Arrow Keys: These scroll through sensors, menu options, and change characters or num­bers in the annotate/edit menus.
Escape: cancels setting changes, cancel read­ings, and scroll to the left in an annotation/edit menu.
EnterAllows you to choose options within menus, start readings, and scroll to the right in an annotation or edit menu.
Save Saves Instrument and Annotation set­tings.
4
ProCheck 3 THE MENUS
3 The Menus
3.1 The Main Menu
The ProCheck features three main menus designed for ease of use. The Main Menu appears when you power up the ProCheck and allows you to take measurements with Decagon sensors.
Changing Your Sensor
Change the sensor type by pressing the up and down arrow keys if the sensor list spinner is available.
Note: You can customize the sensor units and calibrations in the Configuration Menu. The sensor version is only shown if the ProCheck was able to retrieve sensor information directly from the sensor. A soil calibration type displays only if it is available for that sensor type.
Taking a Reading
To take a reading, scroll through the sensor list until you find the sensor type you want to read. Plug the sensor into the stereo jack on the top of the ProCheck.
5
3 THE MENUS ProCheck
Press Enter to engage the live update mode. In live update mode, a live updating icon displays in the lower right corner during updates. The ProCheck continuously updates the screen with the latest sensor reading. Press Enter again to restart the sensor. Press Esc to exit the live update mode. Press Save to save the current reading on the display and annotate your readings.
Annotating a Reading
Once you have taken a reading, press Save to show the Annotate screen. The left side of the screen shows a reading summary and the right side of the screen shows the annotation field as well as the date and time of the reading.
Use the up and down arrow keys to change the current character and use the left and right arrows to change the cursor position. Press Save to save the annotation and Menu to return to the Main screen with­out saving the record.
Note: The ProCheck remembers the last annotation stored into mem­ory, use the arrows to clear all or part of any old annotations. This clears all the characters to the right of the current cursor position.
3.2 The Configuration Menu
Navigate to the Configuration Menu, press Menu until highlighting the Configuration tab. Several different options are available for
6
ProCheck 3 THE MENUS
customizing the instrument.
Units Sub Menu
From this menu you can configure your unit preferences for various unit types.
7
3 THE MENUS ProCheck
Use the arrows to navigate to the correct unit and press Enter to cycle through the unit options.
The “Show Unprocessed Data” option allows you to view any for­matted data in its raw analog to digital count (ADC) state. When you check this option, all data readings on the main and data screens displays in an unprocessed format as seen on the following screen. This is helpful when troubleshooting sensors or when creating your own custom calibration. To save your changes, press Save. To cancel without saving, press Esc.
Calibration Type Sub Menu
Some sensors support a calibration adjustment for different media types (soil, rockwool, etc.). The first screen shows a summary of the selected soil calibrations for each configurable sensor.
8
ProCheck 3 THE MENUS
To modify the sensor calibration type, press Enter. You can choose a preset soil calibration type or create your own (See creating a Custom Calibration). To change the soil calibration type, select the medium option and press Enter. You can view the calibration coefficients by pressing Enter when the coefficients option is highlighted.
Press Save to save your calibration preference or press Esc to exit without saving changes.
The following sensors support soil calibrations.
9
Loading...