Deatec P0040F0061 User Manual

IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 1
REFERENCE : P0050F0078
User’s Guide
Due to technological advances, the manufacturer reserves the right
a For heating
Made : - for controlling Webasto Air Top 2000/3500/5000(ST), AIR TOP Evo 3900/5500 or Eberspächer airtronic D1LC/D2 or D4+ (only with GO-112) autonomous auxiliary heating systems. Regulation of temperature and feedback of any errors.
- for controlling Kalori, AutoClima or Eberspächer Zenith 8000 unit heater air exchange / hot water heating systems. Control of motor speed by PWM pulse (possibility to disable with micro-switch). Control of hot solenoid valve according to temperature instructions. Connection of a temperature sensor type DS-18S20.
a For cooling
Adapted to suit Kalori air conditioning systems with air exchange / cool current. Control of motor speed (possibility to disable with micro-switch). Control of cool solenoid valve according to temperature instructions and conditioned air from the vehicle. Connection of a temperature sensor type DS-18S20.
Only compatible with Ideatec S.A. systems
&
ATTTENTION : control of motor speed is not possible with brushless type motor.
Universal interface for auxiliary heating/cooling systems control
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 2
0.34 22 X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
0.5 20 X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
0.75 18 X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
1.5 16 X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
2.5 14 1.2m
4 Feet
1m
3.5 Feet
0.9m
3 Feet
0.9m
3 Feet
0.9m
3 Feet
X
X
X
X
X
X X X
4 12 1.8m
6 Feet
1.7m
5.5 Feet
1.5m
5 Feet
1.5m
5 Feet
1.3m
4.5 Feet
1.2m
4 Feet
1.2m
4 Feet
1m
3.5 Feet
1m
3.5 Feet
6 10 3.0m
10 Feet
2.7m
9 Feet
2.4m
8 Feet
2.2m
7.5 Feet
2.1m
7 Feet
2m
6.5 Feet
1.8m
6 Feet
1.8m
6 Feet
1.6m
5.5 Feet
10 8 4.7m
15.5 Feet
4.2m
14 Feet
4m
13 Feet
3.6m
12 Feet
3.3m
11 Feet
3.2m
10.5 Feet
3m
10 Feet
2.7m
9 Feet
2.5m
8.5 Feet
16 6 7.6m
25 Feet
6.8m
22.5 Feet
6.2m
20.5 Feet
5.8m
19 Feet
5.3m
17.5 Feet
5m
16.5 Feet
4.7m
15.5 Feet
4.4m
14.5 Feet
4.2m
14 Feet
25 4 12m
39.5 Feet
11m
36 Feet
10m
33 Feet
9.2m
30.5 Feet
8.5m
28 Feet
8m
26.5 Feet
7.4m
24.5 Feet
7m
23 Feet
6.7m
22 Feet
35 2 19.2m
63 Feet
17.3m
57 Feet
16m
52.5 Feet
14.7m
48.5 Feet
13.7m
45 Feet
12.8m
42 Feet
11.8m
39 Feet
11.2m
37 Feet
10.6m
35 Feet
50A 55A 60A 65A 70A 75A 80A 85A 90A
0.34 22 1.8m
6 Feet
0.9m
3 Feet
X
X
X
X
X
X
X
X
X
X
X
X X X
0.5 20 2.9m
9.5 Feet
1.5m
5 Feet
0.9m
3 Feet
X
X
X
X
X
X
X
X
X
X X X
0.75 18 4.5m
15 Feet
2.2m
7.5 Feet
1.5m
5 Feet
1.2m
4 Feet
0.9m
3 Feet
X
X
X
X
X
X X X
1.5 16 7.5m
24.5 Feet
3.5m
12 Feet
2.4m
8 Feet
1.8m
6 Feet
1.5m
5 Feet
1.2m
4 Feet
1m
3.5 Feet
0.9m
3 Feet
X X
2.5 14 12m
39 Feet
6m
19.5 Feet
4m
13 Feet
2.8m
9.5 Feet
2.5m
8 Feet
2m
6.5 Feet
1.6m
5.5 Feet
1.5m
5 Feet
1.3m
4.5 Feet
4 12 20m
62 Feet
9.5m
31 Feet
6m
20.5 Feet
4.7m
15.5 Feet
3.8m
12.5 Feet
3.2m
10.5 Feet
2.7m
9 Feet
2.3m
7.5 Feet
2.1m
7 Feet
6 10 30m
98 Feet
15m
49 Feet
10m
32.5 Feet
7.5m
24.5 Feet
6m
19.5 Feet
5m
16.5 Feet
4.2m
14 Feet
3.8m
12.5 Feet
3.3m
11 Feet
10 8 48m
156 Feet
24m
78 Feet
16m
52 Feet
11.8m
39 Feet
9.4m
31 Feet
8m
26 Feet
6.8m
22.5 Feet
5.9m
19.5 Feet
5.3m
17.5 Feet
16 6 75m
248 Feet
37m
124 Feet
25m
82.5 Feet
18.8m
62 Feet
15m
49.5 Feet
12.6m
41.5 Feet
10m
35.5 Feet
9.4m
31 Feet
8.3m
27.5 Feet
25 4 120m
395 Feet
60m
197 Feet
40m
131 Feet
30m
98.5 Feet
24m
79 Feet
20m
66 Feet
17m
56.5 Feet
15m
49.5 Feet
13.4m
44 Feet
35 2 190m
629 Feet
95m
314 Feet
63m
209 Feet
47m
157 Feet
38m
125 Feet
31m
104 Feet
27m
89.5 Feet
2.9m
78.5 Feet
21m
69.5 Feet
5A 10A 15A 20A 25A 30A 35A 40A 45A
X
2.
Dimensioning of electric wires
WIRE
mm² AWG
FILS
mm² AWG
MAXIMUM AUTHORISED CURRENT IN THE WIRES
MAXIMUM AUTHORISED CURRENT IN THE WIRES
ABACUS FOR THE DIMENSIONING OF ELECTRIC WIRES
The safety of future users of this product depends on your installation. Therefore, it is critical that you read,
understand, and follow all instructions contained in this installation guide.
Some instructions and precautions that must be applied are listed below :
I To install this equipment correctly, it is essential to have the understanding and the technical skills for the installation
of automobile electronics.
I Never install any devices or accessories inside the airbag deployment area. Such installation might reduce the
effectiveness of the airbag or prevent it from being deployed. It can also potentially damage or dislodge the device, causing serious or fatal injuries.
I If you need to drill a hole in the dashboard, make sure that both sides are completely free to avoid damaging the
vehicle.
I Always install the console or the power module in a ventilated area, and never close to a heat source. I It is imperative to dimension correctly all wires installed and connected to the positive battery terminal (see the chart
on page 2) and protected by a proper fuse placed as close as possible to the battery.
I To ensure a correct operation of the device installed, it is necessary to make a perfect connection to the negative
terminal. The negative output of the device must be connected to the negative terminal of the battery as directly as possible.
I The same applies to any elements controlled by the installed device. I Make sure that none of the vehicle's original controls are affected by the installed device. I Place this installation guide in a safe place and refer to it when necessary and for each installation. I Failure to follow safety guidelines and instructions may cause material damages, injuries, or death to you and to
others.
It is essential and mandatory to dimension electrical wires correctly according to the currents used and the length of the wires. Failure to dimension correctly may cause damage inside the vehicle. The products are equipped with static relay outputs only. The use of static relays has several advantages, among which the suppression of external fuses.
Safety and Precautions
= Insufficient
1.
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 3
2
1
L= 2m.
3
4
L= 4m.
1 Connector PHOENIX 6P A No Pin Extractor
Needed
1 Connector PHOENIX 12P A4601B0122112 691 361 100 012 No Pin Extractor Needed
4601B0122106 691 352 710 006
Qty Description P/N Ideatec Reference Ref. Tool Extractor
Two PHOENIX connectors (12 & 6 positions) are necessary for connections on Unitherm-HD.
3.4 Connectors for UNITERM-HD
In order to ensure perfect operation, only accessories and BUS cables assembled and supplied by
the manufacturer are accepted. Otherwise, unless authorised in writing, the manufacturer will not
accept any warranty or liability on the equipment installed.
Standard length = 2 meters - P/N : P0020F0023
Special order option :
Length = 4 meters - P/N : P0020F0024
3.3 2xRJ11 Bus Cable
UNITHERM-HD < > Power Module (MCduo only)
Item
1 2 3 4
P/N
P0040F0061 P0020F0073 A4601B0122106 A4601B0122112
Qty
1 1 1 1
DESCRIPTION
Complete Unitherm-HD interface R.F. Sensor Box DS-18S20 Connector 12 screws terminal Connector 6 screws terminal
3.1 UNITHERM-HD interface + sensor
Product description
3.
3.2 2xRJ45 (GO-112 only)Bus Cable
Standard length = 4 meters - P/N : P0020F0027
Special order option :
Length = 1 meter - P/N : P0020F0042 Length = 6 meters - P/N : P0020F0043 Length = 10 meters - P/N : P0020F0029 Length = 15 meters - P/N : P0020F0044
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 4
Operating Voltage Operating current Operating Temperature Solenoid control valve Solenoid control valve max. current Motor PWM output PWM max. current Weight Dimensions (L x W x D) Regl.10-04 Conformity
:
: from -25°C to +60°C : 2 : 1A : 1 : 20A : 185 g. : 105 x 42 x 66 mm : E13-10R-04 12869
from 10VDC to 30VDC
35mA
Do not attempt to enlarge
the mounting holes.
Ü
Ü
Choose a flat surface and use 4 appropriate fixation screws.
ÜTake into account the size of the different connectors that will be
added to the assembly.
Always install the Unitherm-HD module in a ventilated area, and never close to a heat source.
PROTECTIONS : Reverse polarity protected Over load protection Over current protection Thermal cut-out
Technical Characteristics
The safety of future users of this product depends on your installation. Therefore, it is critical that
you read, understand, and follow all instructions contained in this installation guide.
iDrilling template on page 5
Module Unitherm-HD Installation
4.
iThe temperature sensor is fixed with the sticker at the bottom of the housing. Do not install directly on the output of
the heat and/or cold air.
5.
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 5
DIA. 5mm
10,00° mm
1
CM
1 2
2 3 4 5 6 7 8 9 10
3 4 5 6 7 8 9 10
CM
104,60° mm
85,00° mm
92,00° mm
CHECK THE SCALE (X & Y)
AFTER PRINTING
CHECK THE SCALE (X & Y) AFTER PRINTING
ATTENTION
THE DRILLING TEMPLATES WERE CREATED BY THE EDITOR USING A 1:1 SCALE. FOR THIS
REASON, SOME PRINTERS OR PRINTING SOFTWARE MAY CAUSE DISTORTIONS ON PRINTING.
YOU SHOULD VERIFY THE SCALE BEFORE USING THE TEMPLATES BELOW.
Drilling Templates
6.
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 6
www.ideatec.be
PMTEC S.A. © 2012
WARNING : READ THE USER
GUIDE BEFORE USE
P/N P0040F0061
2
3
1
4 5
BUS GO-112 BUS GO-112 BUS SENSOR
1 2
POWER
ERROR CODE
SENSOR 1 & 2
I²C
K-LINE
RXD
TXD
RXD
TXD
RESERVED-12 RESERVED-11 RESERVED-10 RESERVED-09
EEPOT-W-08
EEPOT-B-07 EBERSCH.-06 WEBASTO-05
COMMON-04
K-LINE-03
COLD VALVE-02
HOT VALVE-01
+VBAT
-BAT
MM
HOT COLD
6 5 4 3 2
1
8 RESERVED 7 RESERVED
ON IF 2 SENSORS
ON IF 2 MOTORS
1 RESERVED
8 7 6 5 4 3 2 1
MC-DUO
IMPORTANT (read user guide)
INSTALL THE CORRECT WIRE SIZE ACCORDING THE MOTOR’S CURRENT DRAW
E13
10R-04 12869
SW4 - SW5 - SW6 SEE USER GUIDE
ON
Crimp a wire end on
each connection
Connections, operations & configuration
7.
7.1 Connections
-02- Cold solenoid valve (max. 1A)
-04- Common Webasto or Eberspächer
-03- K-Line Webasto or Eberspächer
-06- Ignition Eberspächer
-08- EEPOT Webasto or Eberspächer
-07- EEPOT Webasto or Eberspächer
-05- Ignition Webasto
-09-10-11-12- Reserved (not-used)
-1- Input : power supply +10 à 28VDC - Mandatory fuse
-3- Output : heating motor positive
-5- Output : airco motor positive
-4- Output : heating motor negative
-2- Input : battery negative
-6- Output : airco motor negative
Bus connection MCduo
Bus connection GO-112
Auxiliary temp.sensor
DS-18S20 (option)
Temp.sensor DS-18S20 heat
Bus connection GO-112
-01- Hot solenoid valve (max. 1A)
iThe Unitherm-HD has 2 bus connections for GO-112. Thanks to
these 2 connections, Unitherm-HD can be placed between two GO-112 elements like central unit and console.
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 7
-02- Led controlled by the Webasto system (error code)
-04- Monitoring for communication with GO-112 or MCduo
-03- Montiroring for temperature sensor
-05- K-Line monitor (Webasto or Eberspächer)
-01- Led monitor for Unitherm-HD power supply
ON OFF
Led ON
Led flashing
Led OFF
Led’s working graphic key
Connections, Operations & configuration
7.
7.3 Led’s Monitoring
7.2 Micro-switch configuration
-07-
-05-
-06-
-03-
-01-
-02-
-04-
-08-
Switch Nr
Reserved
Switch ON if second optionnal sensor is plugged
Switch ON to disable the PWM on the 2 motors outputs
Switch ON to split heating and cooling motors outputs control
Reserved
Description
Selection of the heating function mode
-04- -05- -06-
OFF OFF OFF
OFF OFF ON
OFF ON OFF
OFF ON ON
ON OFF OFF
ON OFF ON
ON ON OFF
ON ON ON
Function mode
Mode 1 : Blower heater
Mode 2 : Regular Webasto (K-Line)
Mode 3 : Webasto ST
Mode 4 : Eberspächer D2 type
Mode 5 : Eberspächer D4Plus
Reserved
Reserved
Reserved
iFor each mode, airco system can be used in addition to the
heating system.
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 8
Connections, Operations & configuration
7.
T° (real measured)
SETTING
TIME
HOT SOLENOID
VALVE
COLD SOLENOID
VALVE
The speed of the motor is proportional to the difference between the fixed point temperature and the temperature measured.
7.4 Operations
T° SETTING
T° SETTING +2,5°
T° SETTING -2,5°
The Unitherm-HD mode is selected inside the GO-112 or the MCduo configuration. The GO-112 is automatically configured regarding to the elements connected to the Unitherm-HD. For the MCduo, please refer to the key K1 property of the rear console.
7.5 Software configuration
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 9
ON
M
-
+
+
M
-
+
+
BUS BUS
COLD VALVE
HOT VALVE
OR
COOLING EXCHANGER UNIT
UNIT HEATER AIR EXCHANGE
HOT WATER HEATING SYSTEMS
Imperative
main fuse
Supply
+10 to 28VDC
No power supply
Not used in mode 1-A
Power supply OK
Temperature sensor OK
8.
DS-18S20 SENSOR
Modes/Mounting
Automatic
OR
Properties Nr 07 or 27
LINKED SYSTEM
8.1 Mode 1 A/B/C : blower heater and/or airco
8.1.1 lower heater AND aircoMode 1-A : b
Installation of the interface to control air/hot water exchange heating systems of Kalori, AutoClima or Eberspächer Zenith 8000
UniTherm-HD
air heater type.
Installation of the airconditionning module in addition to the heating system.
Not used in mode 1-A
Communication with GO-112 or MCduo OK No communication with GO-112 or MCduo
No temperature sensor
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 10
ON
M
-
+
+
BUS BUS
HOT VALVE
OR
UNIT HEATER AIR EXCHANGE
HOT WATER HEATING SYSTEMS
Imperative
main fuse
Supply
+10 to 28VDC
No power supply
Not used in mode 1-B
Power supply OK
Temperature sensor OK
8.
DS-18S20 SENSOR
Modes/Mounting (following)
Automatic
OR
Properties Nr 06 or 26
LINKED SYSTEM
8.1 Mode 1 A/B/C : blower heater and/or airco (following)
8.1.2 lower heater onlyMode 1-B : b
Installation of the interface to control air/hot water exchange heating systems of Kalori, AutoClima or Eberspächer Zenith 8000
UniTherm-HD
air heater type.
Not used in mode 1-B
Communication with GO-112 or MCduo OK No communication with GO-112 or MCduo
No temperature sensor
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 11
ON
M
-
+
+
BUS BUS
COLD VALVE
OR
COOLING EXCHANGER UNIT
Imperative
main fuse
Supply
+10 to 28VDC
No power supply
Not used in mode 1-C
Power supply OK
Temperature sensor OK
8.
DS-18S20 SENSOR
Modes/Mounting (following)
Automatic
OR
Properties Nr 07 or 27
LINKED SYSTEM
8.1 Mode 1 A/B/C : blower heater and/or airco (following)
8.1.3 irco onlyMode 1-C : a
Installation of the airconditionning module.
Not used in mode 1-C
Communication with GO-112 or MCduo OK No communication with GO-112 or MCduo
No temperature sensor
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 12
X9.2
X9.1
X9.3
X9.4
X8.2
ON
M
-
+
+
BUS BUS
Connector placed on the original potentiometer.
COLD VALVE
OR
COOLING EXCHANGER UNIT
Imperative
main fuse
Supply
+10 to 28VDC
No power supply
Power supply OK
Temperature sensor OK
8.
DS-18S20 SENSOR
Modes/Mounting (following)
Automatic
OR
Properties Nr 30 or 34
LINKED SYSTEM
i
shows the error codes generated by the Webasto. Please refer to the error list provided by Webasto to know the signification.
Thanks to its screen, the GO-112
8.2 Mode 2 A/B : Webasto non-ST with or without airco
8.2.1 Webasto non-ST AND aircoMode 2-A :
Installation of the interface to control heating systems Webasto non-ST like AirTop 2000/3500/5000 (old models).
UniTherm-HD
Installation of the airconditionning module in addition to the heating system.
Communication with Webasto by K-Line OK
Communication with GO-112 or MCduo OK No communication with GO-112 or MCduo
No temperature sensor
(Error codes, see user guide Webasto)
Led directly controlled by the Webasto
No communication with Webasto by K-Line
BLUE
RED
BLACK
GREEN/WHITE
WEBASTO UNIT
WHITE
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 13
X9.2
X9.1
X9.3
X9.4
X8.2
ON
BUS BUS
Connector placed on the original potentiometer.
OR
Imperative
main fuse
Supply
+10 to 28VDC
No power supply
Power supply OK
Temperature sensor OK
8.
DS-18S20 SENSOR
Modes/Mounting (following)
Automatic
OR
Properties Nr 28 or 32
LINKED SYSTEM
i
shows the error codes generated by the Webasto. Please refer to the error list provided by Webasto to know the signification.
Thanks to its screen, the GO-112
8.2 Mode 2 A/B : Webasto non-ST with or wihtout airco (following)
8.2.2 Webasto non-ST onlyMode 2-B :
Installation of the interface to control heating systems Webasto non-ST like AirTop 2000/3500/5000 (old models).
UniTherm-HD
Communication with Webasto by K-Line OK
Communication with GO-112 or MCduo OK No communication with GO-112 or MCduo
No temperature sensor
(Error codes, see user guide Webasto)
Led directly controlled by the Webasto
No communication with Webasto by K-Line
BLUE
RED
BLACK
GREEN/WHITE
WEBASTO UNIT
WHITE
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 14
X9.2
X9.1
X9.3
X9.4
X8.2
ON
M
-
+
+
BUS BUS
Connector placed on the original potentiometer.
COLD VALVE
OR
COOLING EXCHANGER UNIT
Imperative
main fuse
Supply
+10 to 28VDC
No power supply
Power supply OK
Temperature sensor OK
8.
DS-18S20 SENSOR
Modes/Mounting (following)
Automatic
OR
Properties Nr 30 or 34
LINKED SYSTEM
i
shows the error codes generated by the Webasto. Please refer to the error list provided by Webasto to know the signification.
Thanks to its screen, the GO-112
8.3 Mode 3 A/B : Webasto ST with or without airco
8.3.1 Webasto ST AND aircoMode 3-A :
Installation of the interface to control heating systems Webasto ST like AirTop 2000ST/3500ST/5000ST or Air Top EVO 3900/5500.
UniTherm-HD
Installation of the airconditionning module in addition to the heating system.
Communication with Webasto by K-Line OK
Communication with GO-112 or MCduo OK No communication with GO-112 or MCduo
No temperature sensor
(Error codes, see user guide Webasto)
Led directly controlled by the Webasto
No communication with Webasto by K-Line
BLUE
RED
BLACK
GREEN/WHITE
WEBASTO UNIT
WHITE
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 15
X9.2
X9.1
X9.3
X9.4
X8.2
ON
BUS BUS
OR
Imperative
main fuse
Supply
+10 to 28VDC
No power supply
Power supply OK
Temperature sensor OK
8.
DS-18S20 SENSOR
Modes/Mounting (following)
Automatic
OR
Properties Nr 28 or 32
LINKED SYSTEM
i
shows the error codes generated by the Webasto. Please refer to the error list provided by Webasto to know the signification.
Thanks to its screen, the GO-112
8.3 Mode 3 A/B : Webasto ST with or wihtout airco (following)
8.3.2 Webasto ST onlyMode 3-B :
Installation of the interface to control heating systems Webasto ST like AirTop 2000ST/3500ST/5000ST or Air Top EVO 3900/5500.
UniTherm-HD
Communication with Webasto by K-Line OK
Communication with GO-112 or MCduo OK No communication with GO-112 or MCduo
No temperature sensor
(Error codes, see user guide Webasto)
Led directly controlled by the Webasto
No communication with Webasto by K-Line
BLUE
RED
BLACK
GREEN/WHITE
WEBASTO UNIT
WHITE
Connector placed on the original potentiometer.
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 16
2
1
6
5
K
ON
M
-
+
+
BUS BUS
Connector placed on the original potentiometer.
COLD VALVE
OR
COOLING EXCHANGER UNIT
Imperative
main fuse
Supply
+10 to 28VDC
No power supply
Power supply OK
Temperature sensor OK
8.
DS-18S20 SENSOR
Modes/Mounting (following)
Automatic
OR
Properties Nr 31 or 35
LINKED SYSTEM
i
shows the error codes generated by the Webasto. Please refer to the error list provided by Webasto to know the signification.
Thanks to its screen, the GO-112
8.4 Mode 4 A/B : Eberspächer Airtronic D1LC/D2 with or without airco
8.4.1 Eberspächer D1LC/D2 type AND aircoMode 4-A :
Installation of the interface to control heating systems Eberspächer like Airtronic D1LC or D2 model.
UniTherm-HD
Installation of the airconditionning module in addition to the heating system.
Communication with GO-112 or MCduo OK No communication with GO-112 or MCduo
No temperature sensor
BROWN/WHITE
YELLOW
RED
BLUE/WHITE
EBERSPÄCHER UNIT
GREY/RED
(Error codes, see user guide Eberspächer)
Led directly controlled by the Eberspächer
Communication with Eberspächer by K-Line OK No communication with by K-LineEberspächer
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 17
2
1
6
5
K
ON
BUS BUS
Connector placed on the original potentiometer.
OR
Imperative
main fuse
Supply
+10 to 28VDC
No power supply
Power supply OK
Temperature sensor OK
8.
DS-18S20 SENSOR
Modes/Mounting (following)
Automatic
OR
Properties Nr 29 or 33
LINKED SYSTEM
i
shows the error codes generated by the Webasto. Please refer to the error list provided by Webasto to know the signification.
Thanks to its screen, the GO-112
8.4 Mode 4 A/B : Eberspächer Airtronic D1LC/D2 with or without airco (following)
8.4.2 Eberspächer D1LC/D2 type onlyMode 4-B :
Installation of the interface to control heating systems Eberspächer like Airtronic D1LC or D2 model.
UniTherm-HD
Communication with GO-112 or MCduo OK No communication with GO-112 or MCduo
No temperature sensor
BROWN/WHITE
YELLOW
RED
BLUE/WHITE
EBERSPÄCHER UNIT
GREY/RED
(Error codes, see user guide Eberspächer)
Led directly controlled by the Eberspächer
Communication with Eberspächer by K-Line OK No communication with Eberspächer by K-Line
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 18
2
1
6
5
K
ON
M
-
+
+
BUS
Connector placed on the original potentiometer.
COLD VALVE
COOLING EXCHANGER UNIT
Imperative
main fuse
Supply
+10 to 28VDC
No power supply
Power supply OK
Temperature sensor OK
8.
DS-18S20 SENSOR
Modes/Mounting (following)
Automatic
LINKED SYSTEM
i
shows the error codes generated by the Webasto. Please refer to the error list provided by Webasto to know the signification.
Thanks to its screen, the GO-112
8.5 Mode 5 A/B : Eberspächer Airtronic D4+ with or without airco
8.5.1 Eberspächer D4+type AND aircoMode 5-A :
Installation of the interface to control heating systems Eberspächer Airtronic D4+ model.
UniTherm-HD
Installation of the airconditionning module in addition to the heating system.
Communication with GO-112 OK No communication with GO-112
No temperature sensor
BROWN/WHITE
YELLOW
RED
BLUE/WHITE
EBERSPÄCHER UNIT
GREY/RED
(Error codes, see user guide Eberspächer)
Led directly controlled by the Eberspächer
Communication with Eberspächer by K-Line OK No communication with Eberspächer by K-Line
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 19
2
1
6
5
K
ON
BUS
Connector placed on the original potentiometer.
Imperative
main fuse
Supply
+10 to 28VDC
No power supply
Power supply OK
Temperature sensor OK
8.
DS-18S20 SENSOR
Modes/Mounting (following)
Automatic
LINKED SYSTEM
i
shows the error codes generated by the Webasto. Please refer to the error list provided by Webasto to know the signification.
Thanks to its screen, the GO-112
8.5 Mode 5 A/B: Eberspächer Airtronic D4+ with or without airco (following)
8.4.2 Eberspächer D4+ type onlyMode 5-B :
Installation of the interface to control heating systems Eberspächer Airtronic D4+ model
UniTherm-HD
Communication with GO-112 OK No communication with GO-112
No temperature sensor
BROWN/WHITE
YELLOW
RED
BLUE/WHITE
EBERSPÄCHER UNIT
GREY/RED
(Error codes, see user guide Eberspächer)
Led directly controlled by the Eberspächer
Communication with Eberspächer by K-Line OK No communication with Eberspächer by K-Line
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 20
X9.2
X9.1
X9.3
X9.4
X8.2
ON
M
-
+
+
BUS BUS
M
-
+
+
HOT VALVE
UNIT HEATER AIR EXCHANGE
HOT WATER HEATING SYSTEMS
Connector placed on the original potentiometer.
COLD VALVE
OR
COOLING EXCHANGER UNIT
Imperative
main fuse
Supply
+10 to 28VDC
No power supply
Power supply OK
Temperature sensor OK
8.
DS-18S20 SENSOR
Modes/Mounting (following)
Automatic
OR
Properties Nr 30 or 34
LINKED SYSTEM
i
shows the error codes generated by the Webasto. Please refer to the error list provided by Webasto to know the signification.
Thanks to its screen, the GO-112
8.6 Using Webasto or Eberspächer
blower heater combined with
Mode 2A-2B-3A-3B-4A-4B-5A-5B allows you to install a supplementary blower heater. Example with Webasto-ST + airco and blower heather :
Communication with Webasto by K-Line OK
Communication with GO-112 or MCduo OK No communication with GO-112 or MCduo
No temperature sensor
(Error codes, see user guide Webasto)
Led directly controlled by the Webasto
No communication with Webasto by K-Line
BLUE
RED
BLACK
GREEN/WHITE
WEBASTO UNIT
WHITE
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 20
9.
10.
All operating modes in only one CD-ROM
A CD-ROM with all operating modes is provided with each
IDEATEC product
PDF format for easy access,
guaranteed updates
less wastage
Your warranty
IDEATEC S.A hereby guarantees that this product is free from defects in material and workmanship for a period of two years from the date of purchase. If, during the warranty period, the product fails due to material or workmanship defects, IDEATEC S.A. will repair or replace (at IDEATEC S.A.'s discretion) the product free of charge, under the following conditions: IDEATEC S.A. reserves the right (at its own discretion) to replace parts of defective products or replace the products low value with new or factory refurbished parts or products. Conditions:
1. This warranty is valid only if the device is accompanied by the original invoice or receipt (containing the date of purchase, the type of product, and the name of the reseller). IDEATEC S.A. reserves the right to deny its free warranty if the aforementioned documents cannot be produced or if the information contained in them are incomplete or illegible.
2. This warranty does not reimburse or cover deterioration resulting from adaptations or adjustments to the product without prior written consent from IDEATEC S.A., mainly to respect technical or safety standards, national or local, in effect in all countries other than for those for which the product is known and manufactured.
3. This warranty does not apply if the model or serial number on the product has been altered, erased, suppressed, or illegible.
4. This warranty does not cover any of the following points: a. Periodic maintenance and repair or replacement of parts from normal usage; b. Any adaptations or modifications aimed at improving the product such as it has been purchased and described in the operating instructions, without prior written agreement from IDEATEC S.A.; c. Transportation costs, home delivery costs, and all transport risks directly or indirectly associated with this product's warranty; d. Installation, removal, and reinstallation costs; e. Deterioration resulting from:
1. Misuse, including, without limitation, (a) improper use of the product without respecting IDEATEC S.A.'s instructions on proper product usage and maintenance, and (b) installation or usage of the product against IDEATEC S.A.'s instructions or technical or safety standards in effect in the country where it is used, and (c) improper or incorrect software installation;
2. Repairs performed by unauthorised repair persons or by the user;
3. Accidents, lightning, flood, fire, improper ventilation, or any other case that exceeds IDEATEC S.A. liability;
4.Failure of the system on which the product is installed.
5.This warranty does not limit the client's statutory rights under national laws in effect in any way, nor the client's rights before the reseller, stipulated in the sales/purchasing contract.
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s Guide Unitherm-HD - Doc. V1.0 - Module V1.4a
Page 21
2
2
3 3 3 3 3
4
4
5
6 6 7 7 8 8
9 9 9 10 11 12 12 13
14 14 15 16 16 17 18 18 19 20
21
21
TABLE OF CONTENTS
Chapter 1 : Safety and precautions...........................................................................................
: Dimensioning of electrical wires.............................................................................
3 : Product description.................................................................................................
Chapter 2
Chapter
3.1 Unitherm-HD - interface + sensor.............................................................................
3.2 2xRJ45 Bus Cable....................................................................................................
3.3 2xRJ11 Bus Cable ...................................................................................................
3.4 Connectors for Unitherm-HD....................................................................................
Chapiter 4 : Module Unitherm-HD Installation..........................................................................
Chapiter 5 : Technical Characteristics.......................................................................................
Chapter 6 : Drilling Templates....................................................................................................
Chapter 7 : Connections, operations & configuration................................................................
7.1 Connections...............................................................................................................
7.2 Micro-switch configuration........................................................................................
7.3 LED ’s Monitoring......................................................................................................
7.4 Operations................................................................................................................
7.5 Software configuration..............................................................................................
Chapter 8 : Modes:Mounting.....................................................................................................
8.1 Mode 1 A/B/C : blower heater and/or airco..............................................................
8.1.1 Mode 1-A : blower heater AND airco..........................................................
8.1.2 Mode 1-B : blower heater only....................................................................
8.1.3 Mode 1-C : airco only..................................................................................
8.2 Mode 2 A/B/C : Webasto non-ST with or without airco (Air Top 2000/3500/5000)...
8.2.1 Mode 2-A : Webasto non-ST AND airco.....................................................
8.2.2 Mode 2-B : Webasto non-ST only...............................................................
8.3 Mode 3 A/B/C : Webasto ST with or without airco
(Air Top 2000ST/3500ST/5000ST or Air Top EVO3900/5500)..................................
8.3.1 Mode 3-A : Webasto ST AND airco ............................................................
8.3.2 Mode 3-B : Webasto ST only......................................................................
8.4 Mode 4 A/B/C : Eberspächer Airtronic D1LC/D2 with or without airco.....................
8.4.1 Mode 4-A : Eberspächer Airtronic D1LC/D2 type AND airco......................
8.4.2 Mode 4-B : Eberspächer Airtronic D1LC/D2 type only................................
8.5 Mode 5 A/B/C : Eberspächer Airtronic D4+ with or without airco..............................
8.5.1 Mode 5-A : Eberspächer Airtronic D4+ type AND airco..............................
8.5.2 Mode 5-B : Eberspächer Airtronic D4+ type only........................................
8.6 Using blower heater combined with Webasto or Eberspächer.................................
Chapter 9 : All our user’s guides on one CD-ROM....................................................................
Chapter 10 : Your warranty........................................................................................................
Loading...