DUAL FUEL RANGES PRODUCT DIMENSIONS
RDU-48, RDU-36, RDU-30
RDU-48
Standard Installation:
using the appropriate range mount
Standard backguard model: BGRU1248, BGRU-1236, or BGRU-1230
Full Backguard Installation:
using the appropriate wall mount Full
backguard model: BGRU-3048,
BGRU-3036, or BGRU-3030
www.dcsappliances.com p. 888-936-7872
Island Installation:
using the integral island trim only
a
RDU-36
a
RDU-30
a
PRODUCT DIMENSIONS (INCHES)
Hood
H
51” Min. to
I I
combustibles
B
Hood Hood
H
C
D
0” Clearance 0” Clearance
E
D
E
F
G
As defined in the “National Fuel Gas Code” (ANSI Z223.1, latest edition).
The horizontal surfaces of the cooktop trim must not be below countertop level.
G
51” Min. to
combustibles
12” Min. to
combustibles
without backguard
,
51” Min. to
combustibles
D
0” Clearance
F
J
K
Important!
If using the island trim only, a 12” clearance is
required between the back of the range and a
combustible surface (above the cooking surface).
If the clearance is less than 12”, the back wall
must be non-combustible and made of heatresistant material.
RDU-48
7
Width of product 47 –
A
Height of full backguard 26 –
B
Height of standard backguard 8 –
C
Height of integral island trim 3 –
D
Height of product (from floor to cooktop trim, excluding grates
E
and island trim)
Maximum depth from wall to front of product (including handle) 30 –
F
Maximum depth from wall to front of product with door open 46 –
G
Maximum depth from wall to front of product (excl. handle and knobs) 29” 29” 29
H
Depth of Backguard 1 –
I
Depth from wall to front of range side panel 25” 25” 25”
J
Depth of product from wall to oven door front (excl. handle) 27 –
K
Product dimensions and specifications are listed as a guide only. For complete installation instructions and specifications, refer to the product Use & Care Guide/Installation Instructions available at www.dcsappliances.com
6467_USA_DCS_RANGE SPEC SHEETS_FLI.indd 5 31/03/14 10:06 AM
/
1
/
1
/
1
/
min. 35 –
max. 36 –
1
/
11
/
5
/
16
1
/
” 35 –
8
” 26 –
2
” 8 –
2
” 3 –
2
3
/
”
4
3
/
”
4
” 30 –
4
” 46 –
16
” 1 –
” 27 –
2
RDU-36
7
/
1
/
1
/
1
/
min. 35 –
max. 36 –
1
/
11
/
5
/
16
1
/
” 29 –
8
” 26 –
2
” 8 –
2
” 3 –
2
3
/
”
min. 35 –
4
3
/
”
max. 36 –
4
” 30 –
4
” 46 –
16
” 1 –
” 27 –
2
RDU-30
7
/
”
8
1
/
”
2
1
/
”
2
1
/
”
2
3
/
3
/
1
/
”
4
11
/
”
16
5
/
”
16
1
/
”
2
”
4
”
4
DUAL RUEL RANGES CABINETRY DIMENSIONS
RDU-48, RDU-36, RDU-30
a
E
www.dcsappliances.com p. 888-936-7872
B
Cooking Surface
D
C
H
see diagrams
following for
G
electrical and gas
connection details
C
LOCATION OF ELECTRICAL AND GAS SUPPLY
RD U
I
J
electrical and gas
F
CABINETRY DIMENSIONS (INCHES)
RDU-48
Minimum width of ventilation hood installed above range 48” 36” 30”
A
Minimum vertical distance between countertop and cabinet extending above counter 18” 18” 18”
B
Minimum clearance from left and right edge of range to nearest vertical combustible
C
12” 12” 12”
RDU-36
surface
Minimum clearance from cooking surface to:
D
- combustible surface centered above the cooking surface
- non-combustible surface centered above the cooking surface
Maximum overall depth of overhead cabinetry 13” 13” 13”
E
Width of cabinetry opening 48” 36” 30”
F
Maximum height from floor to countertop:
G
- with range levelling legs fully retracted
- with range levelling legs fully extended
Maximum depth from wall to cabinet front 25” 25” 25”
H
Distance from either edge of range to supply area 1 –
I
Height of gas and electrical supply areas (from floor) 6” 6” 6”
J
Depth of supply areas (ie maximum protrusion of gas connection from wall) 2” 2” 2”
K
51”
30”
35 –
36 –
3
/
3
/
1
/
2
51”
30”
”
4
”
4
35 –
36 –
” 1 –
3
/
”
4
3
/
”
4
1
/
” 1 –
2
Final position of
range against wall
I
K
35 –
36 –
RDU-30
51”
30”
3
/
4
3
/
4
1
/
”
2
”
”
Product dimensions and specifications are listed as a guide only. For complete installation instructions and specifications, refer to the product Use & Care Guide/Installation Instructions available at www.dcsappliances.com
6467_USA_DCS_RANGE SPEC SHEETS_FLI.indd 6 31/03/14 10:06 AM