DCS DD-36SS, DD-30SS User Manual

THE PROFESSIONAL DOWNDRAFT
Use and Care Guide
MODELS:
DD-36SS DD-30SS
A MESSAGE TO OUR CUSTOMERS
Thank you for selecting this DCS Downdraft Vent System. Because of its unique features, we have developed this Use and Care Guide. It contains valuable information on how to properly operate and
aintain your new Downdraft Vent System for years of safe and enjoyable service.
m
o help serve you better, please fill out and return the Ownership Registration Card and keep this
T guide handy, as it will help answer questions that may arise as you use your Downdraft Vent System.
For your convenience, product questions can be answered by a DCS Customer Care Representative by phone: 1-888-281-5698, email: support@dcsappliances.com
or by mail: Fisher & Paykel Appliances, Inc. Attention: DCS Customer Care 5900 Skylab Road Huntington Beach, CA 92647 www.dcsappliances.com
NOTE: Please write the Model and Serial Number on this page for references (can be found on right side of the blower motor box).
MODEL NUMBER
SERIAL NUMBER
WARNING
TO REDUCE THE RISK OF A COOK TOP GREASE FIRE:
Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium setting. Always turn the Downdraft “ON”when cooking at high heat or when cooking flaming foods. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING
O REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A
T COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING: SMOTHER FLAMES
ie sheet
with a close-fitting lid, c burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT. NEVER PICK UP A FLAMING PAN - You may be burned. DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result. Use an e
xtinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know e it
o opera
w t
ho
2. The fire is small and contained in the area where it started.
The fire department is being called.
3.
4. You can fight the fire with your back to an exit.
t
ook
.
, or metal tray, then turn off the
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE.
TABLE OF CONTENTS
SAFETY PRACTICES & PRECAUTIONS...............................................................................................................3
USE AND CARE....................................................................................................................................................................4
WIRING DIAGRAM............................................................................................................................................................5
HOW TO OBTAIN SERVICE..........................................................................................................................................6
WARRANTY ........................................................................................................................................................................7-8
SAFETY PRACTICES & PRECAUTIONS
WARNING:
ALL WALL AND FLOOR OPENINGS WHERE THE Downdraft IS INSTALLED MUST BE SEALED.
Consult the cooktop or range installation instructions given by the manufacturer before making any cutouts. MOBILE HOME INSTALLATION - The installation of this Downdraft must conform to the Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280). Three wire power supply must be used and the appliance wiring must be revised. See Electrical Requirements.
Venting system MUST terminate outside the home.
DO NOT terminate the ductwork in an attic or other enclosed space.
DO NOT use 4" laundry-type wall caps.
Flexible-type ductwork is not recommended.
DO NOT obstruct the flow of combustion and ventilation air.
Failure to follow venting requirements may result in a fire.
Electrical ground is required on this Downdraft system.
If cold water pipe is interrupted by plastic, non-metallic gaskets or other materials, DO NOT use
for grounding.
DO NOT ground to a gas pipe.
DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding
circuit could result in electrical shock.
Check with a qualified electrician if you are in doubt as to whether the downdraft is properly
grounded.
Failure to follow electrical requirements may result in a fire.
WARNING:
O REDUCE
T PERSONS, OBSERVE THE FOLLOWING:
Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Installation Work And Electrical Wiring Must Be Done By Qualified Person(s) In Accordance With All Applicable Codes And Standards, Including Fire-Rated Construction. Sufficient air is needed for proper combustion and exhausting of gases from fuel burning equipment through the flue (chimney) to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Ducted fans must always be vented to the outdoors.
THE RISK OF FIRE
, ELEC
AL SHOCK
TRIC
, OR INJURY TO
USE & CARE INFORMATION
This vent system is designed to remove smoke, cooking vapors and odors from the cooktop area. This unit also has several features to insure operator safety.
TO OPERATE THE DOWNDRAFT
Push the Up/Down button on top of the Downdraft to raise the plenum as indicated. The speed control knob is located on the right hand side of the plenum. Press the Up/Down button to lower the unit. The Up/Down button must be pressed and held momentarily to raise or lower the plenum. This is a safety feature which protects against accidental activation when cleaning the plenum. For best results, start the Downdraft before cooking and allow the unit to operate for several minutes after cooking is complete to clear all smoke and odors from the kitchen. If using large pots, place them on the rear burner to insure proper ventilation. A higher fan setting may be required.
CLEANING
The metal grease filters should be cleaned frequently in hot detergent solution or washed in the dishwasher. The plenum and top strip should be cleaned with stainless steel cleaner. Abrasives and scouring agents can scratch stainless steel finishes and should not be used.
Control knob
USE WITH GAS COOKTOPS
The DCS Downdraft Vent System is designed for safe use with gas cooktops and will not extinguish burners or pilots. The blower does not start operation until the plenum has reached the full upright position. Also, the blower stops operation as soon as the Up/Down switch is pressed to lower the unit.
WARNING:
If a spill occurs on the cooktop that allows liquids to seep inside the Downdraft, you must turn the Downdraft off immediately. It is possible to cause damage to the Downdraft if water is allowed inside the Downdraft while it is opera
Immediately turn “OFF” the Downdraft at the speed control located on the right hand side of
the Downdraft.
Turn “OFF” the power supply to the Downdraft at the circuit breaker box or fuse box.
Allow plenty of time for the Downdraft to dry naturally. Do not open the Downdraft to remove
the water. Failure to follow these warnings could result in damage to the Downdraft.
ting.
SAFETY MICROSWITCHES
This Downdraft Vent System is designed with a safety microswitch behind the center of each grease filter. These microswitches prevent the blower and plenum-raising mechanism from operating when either of the grease filters is removed. It is very important to make sure that the grease filters are properly and firmly in place after cleaning. If the unit does not operate after replacing the grease filters, make sure the filters are properly installed and are making firm contact with the safety microswitches.
WIRING DIAGRAM
GEAR
MOTOR
BLU
WHT
WHT
BLK
WHT
BLK
BLK
BLK
WIRING
BOX
LINE IN
120 VAC
60 Hz
GRN
WHT
ISWITCH
DOWN N.C.
SWITCH
UP N.C.
BLK BLK
BLK BLK
BLK
BLK
BLK
WHT
S
PEE
D
CON
TROL
SWITCH
FAN N.O.
SWITCH
FILTER N.O.
N.O.
WHT
11 UF
PUSH
BUTTON
BLOWER
MOTOR
M
8/50K-A120
BLU
BLU
SERVICE
HOW TO OBTAIN SERVICE:
Before you call for service:
1) Is the circuit breaker tripped or the fuse blown?
2) Is there a power outage in the area?
3) Are the grease filters properly installed?
4) Will the unit go up/down and the blow control is on?
For warranty service, contact DCS Customer Care at (888) 281-5698. Before you call, please have the following information ready:
Model Number
(can be found on right side of the blower motor box).
Serial Number
Date of installation
A brief description of the problem
Your satisfaction is of the utmost importance to us. If a problem cannot be resolved to your satisfaction, please write at:
Write: Fisher & Paykel Appliances, Inc. Attention: DCS Customer Care 5900 Skylab Road Huntington Beach, CA 92647
(can be found on right side of the blower motor box).
Loading...