DCS CDU-365, CDU-304, DD36 Specification Sheet

Product dimensions and specifications are listed as a guide only. For complete installation instructions and specifications, refer to the product Use & Care Guide/Installation Instructions available at www.dcsappliances.com
www.dcsappliances.com p. 888-936-7872
PRODUCT DIMENSIONS (INCHES)
CDU-365
CDU-304
A
Overall depth of product 21” 21”
B
Overall width of product 36” 30”
Width of product chassis 34 –
1
/
2
28 –
5
/
16
D
Distance from right edge of chassis to center line of gas inlet 2 –
3
/
4
2 –
11
/
16
E
Height of chassis 4” 4”
F
Overall height of product (from bottom of chassis to top of grates) 5 –
1
/
2
5 –
1
/
2
G
Distance from rear edge of chassis to center line of gas inlet 4 –
9
/
16
1 –
1
/
2
H
Depth of product chassis 19 –
1
/
2
19 –
1
/
2
DROP-IN COOKTOP PRODUCT DIMENSIONS
CDU-365 & CDU-304
A
A
B
C
E
B
C
D
E
F
G
G
H
H
CDU-365
CDU-304
Top View
Front View
Top View
Front View
Right Side View
Right Side View
F
Product dimensions and specifications are listed as a guide only. For complete installation instructions and specifications, refer to the product Use & Care Guide/Installation Instructions available at www.dcsappliances.com
www.dcsappliances.com p. 888-936-7872
DD36
F
Width of cutout recess for ventilation system
33 –
1
/
2
H
Depth of cutout recess for ventilation system
2 –
5
/
8
*As defined in the “National Fuel Gas Code” (ANSI Z223.1, latest edition). NOTE: See manufacturer’s recommendations for ducting specifications.
*As defined in the “National Fuel Gas Code” (ANSI Z223.1, latest edition). The horizontal surfaces of the range top (cooktop) trim must not be below countertop level. NOTE: See manufacturer’s recommendations for ducting specifications.
DROP-IN COOKTOP CUTOUT AND CABINETRY DIMENSIONS
CDU-365, CDU-304, CDU-365 & DD36
F
B
A
C
D
E
G
H
I
B
A
C
D
E F
G
H
K
I
J
WHEN INSTALLING WITH A RANGEHOOD
CDU-365
CDU-304
A
Vertical distance from counter-top to cabinet extending above counter
18” MIN 18” MIN
B
Depth of overhead cabinetry 13” MAX 13” MAX
Min. clearance from left edge of cutout to nearest vertical combustible surface
5 –
5
/
8
5 –
11
/
16
D
Depth of cutout 19 –
3
/
4
19 –
3
/
4
E
Width of cutout 34 –
3
/
4
28 –
5
/
8
F
Minimum width of rangehood 36” 30”
G
Minimum clearance from rear edge of cooktop cutout to back wall
2 –
1
/
2
2 –
1
/
2
H
Minimum distance from countertop to top of electrical and gas supply area
5” 5”
I
Width of electrical and gas supply area 18” 18”
WHEN INSTALLING WITH A DCS DD-36 VENTILATION SYSTEM
CDU-365
A
Vertical distance from counter-top to cabinet extending above counter
18” MIN
B
Depth of overhead cabinetry 13” MAX
Min. clearance from left edge of cutout to nearest vertical combustible surface
5 –
5
/
8
D
Depth of cooktop cutout (excl downdraft recess)
19 –
3
/
4
E
Width of cooktop cutout 34 –
3
/
4
G
Minimum clearance from rear edge of vent cutout to back wall
1
/
2
” MIN
I
Width of electrical and gas supply area 9”
J
Minimum distance from countertop to top of electrical and gas supply area
26 –
1
/
2
K
Minimum distance between overhead cabinets installed to either side of product
36” MIN
CAUTION: 36” min. to combustible material*, from cooking surface
CAUTION: 36” min. to combustible material*, from cooking surface
electrical and gas supply
electrical and gas supply