DCI LLC LEG LESS PALISADES, MONTECITO, PARKWAY Instruction Manual

COOKE FIRE PIT TABLE INSTRUCTIONS
GENERAL GUIDE FOR LEG LESS PALISADES, PARKWAY, MONTECITO
Owner’s Manual
INSTALLLER AND CONSUMER: These instruction MUST be retained with this Fire Pit for Future reference
AND OTHER MODELS
Rev. DC0813
Warning– If these instructions are not followed, a fire or
explosion may result causing property damage, personal injury and/or loss of life.
Do not store or use gasoline or other flammable liquids in the vicinity of your fire pit or fire pit table.
Do not try to light the appliance Do not touch any electrical switch; do not use any
phone in your building. Immediately call your gas supplier from a neighbor
phone. Follow the gas supplier’s instructions. If you cannot contact reach your gas supplier call the
fire department
CAUTION: Installation and maintenance must be done by an NFI Certified or other qualified professional in­staller. Installer must read and understand these instruc­tions and safety precautions prior to installing this fire pit/table.
We highly recommend our products to be installed and serviced by professionals who are certified in the U.S. by NFI (National Fireplace Institute) as a Gas Specialist.
Installer must follow all instructions herein carefully, to ensure proper product performance and safety. David Cooke Industries LLC is not responsible for improper in­stallation or use of this product.
WARNING
FOR OUTDOOR USE ONLY
Important: Read these instructions care-
fully before installing your fire pit /table.
WARNING
Improper installation, adjustment, alteration, service or maintenance of your fire pit or fire pit table may cause prop­erty damage, personal injury or loss of life. Read the installation, operating and maintenance instructions thoroughly be­fore installing or servicing this appliance.
IMPORTANT
For safe operation, proper product per­formance and to comply with certifica­tion, listing, and building codes, use ONLY supplied controls, parts, and accessories that have been specifically listed or certi­fied for use with the supplied burner sys­tem. Use of other controls, parts, or ac­cessories is prohibited and will void all warranties, certifications, listings, and/or building code approvals.
A responsible adult must be present while this unit is operating. This appliance must never be left unattended while the fire feature is lit. If this product is left burning unattended, it may cause property dam­age and/or serious injury.
Code and supply requirements: Fire pit/table installation must conform with local codes & or­dinances, or, in the absence of local codes, with the latest National Fuel Gas Code, ANSI Z223.1
DCI LLC All Rights Reserved: For technical support call (951)-805-0314 1
SAFETY FIRST- PRE-INSTALLATION AND IMPORTANT WARNINGS
A. Make sure none of the components were damaged during shipping before installing this outdoor fire pit
or fire pit table. Refer to the FIRE PIT/TABLE CLEARANCE TO COMBUSTIBLES section on pg.4, to ensure the surrounding area is properly sized for safe installation.
B. The fire pit/table is for outdoor use only. Do not install or use this appliance inside a building, garage, or
any other enclosed area, including recreational vehicles and/or boats. This unit must be installed so that the vent opening at the base of the unit remains clear and free of any obstruction at all times.
C. CHECK GAS TYPE (natural gas or propane): Check the unit burner components to verify that the gas sup-
ply you intent to use is compatible with the components supplied with the unit. If the gas supply is differ­ent, please contact David Cooke Industries LLC.
D. DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS
EXCEEDED. Gas type and pressure must be checked prior to installation and use as follows:
For a natural gas fire pit/table: Supply Pressure: Minimum: 3.5” W.C.; Maximum: 7.0” W.C. Outlet Pressure: 3.5” to 5.0” W.C.
For a propane gas fire pit/table: Supply Pressure: Minimum: 8.0” W.C.; Maximum: 15.0” W.C. Outlet Pressure: 10.0” to 12.0” W.C.
E. Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (Btu/hr)
for the unit’s respective gas type.
F. All natural gas fire pits/tables must have an emergency gas shut-off valve located on the premises
(commonly located on the gas supply line for the buildingplease refer to local Building Code). An addi­tional gas supply shut-off valve should be installed in or near the fire pit/table for maintenance and safety (it is recommended to shut off supply gas when fire pit/table is not in use).
G. The fire pit/table and its flame height adjustment valve must be disconnected from the gas supply piping
system during any pressure testing of that system at pressure in excess of 1/2 psi (3.5 kPa). This is neces­sary to ensure that the fire pit/table valve, regulator and components are not damaged.
H. Gas-Supply plumbing requirements: Apply only joint compounds (i.e., yellow plumber’s tape) that are re-
sistant to all gasses on all male pipe fittings. Make sure to tighten every joint securely. Do not use joint compound to connect flare fittings, as it is not necessary and could compromise functionality. Bring the gas supply pipe up from beneath the table base near it’s center (if applicable to unit).
I. Select a location with good drainage that allows easy access for installation and maintenance of the fire
pit/table.
WARNING: It is the installer’s responsibility to ensure a safe installation and to educate the end user as to
proper operation of the unit. This manual shall be left with the owner/operator of this unit for reference.
WARNING: FOR REMOTE CONTROL USE: To prevent accidental start-up from unwanted RF (radio frequency)
signals it is the responsibility of the end user to turn off power to electric outlet (via wall switch or breaker) for the remote control receiver when the fire-pit/table is not in use .
WARNING: It is the responsibility of the installer to follow ALL LOCAL CODES concerning the installation and
operation of the fire pit. In the absence of local codes, please follow:
Fixed piping system: The National Fuel Gas Code, ANSI Z223.1/NFPA 54 or International Fuel Gas Code. Electrical ground: The National Electrical Code, ANSI/NFPA 70.
OPERATING THE FIRE PIT/TABLE SAFELY AND IMPORTANT WARNINGS
A. This appliance should be inspected before use. It is imperative that the control compartment, burner and
circulating air passageways of the appliance are kept clean.
B. Improper installation and placement of the fire pit/table and decorative media WILL IMPAIR ITS EFF-
CEINCY AND MAY CAUSE THE UNIT TO MALFUNCTION.
C. This appliance is only intended for operation in temperatures above 32 degrees F. Do not operate fire pit
in windy or poor weather conditions. Temperate, calm weather conditions are optimal for fire pit/table
use. D. When shutting off the fire pit/table ensure the CONTROL VALVE IS IN THE FULL OFF POSITION. E. DO NOT sit or place any part of the body, clothing, or other flammable material on or near the fire pit/
table. Every time you use the unit, make sure that the area around the unit is clear and free from com-
bustible materials. The Fire Pit should never be covered when lit.
DCI LLC All Rights Reserved: For technical support call (951)-805-0314 2
OPERATING THE FIRE PIT/TABLE SAFELY AND IMPORTANT WARNINGS
WARNING: Both children and adults should be alerted to the hazards of high surface temperatures and
should avoid flames to prevent burns and/or clothing ignition. Fire pits/tables create very high tempera­tures, so combustibles must be located far enough away that there is no risk of ignition.
IMPORTANT: To prevent damage or cracking it is recommended that material such as granite, marble or
other dense stone be kept away from excessive heat and especially direct flame contact, which can result from use during windy conditions.
WARNING: If your fire pit/table is making the surrounding stone surface hot, turn it down or off immedi-
ately. Your fire pit is not intended to be operated at maximum output for extended periods of time. Large and/or quick temperature variations may cause stone to crack.
WARNING: For electronic ignition models there must be an electrical shut off ( wall switch or breaker ) on
the exterior of the fire pit or on an adjacent wall to allow for emergency shutdown and maintenance.
WARNING: This product is not intended to be a starter for wood or any other combustible material. Never
alter this product or configuration in any way. A. SOLID FUEL MUST NOT BE BURNED in the fire pit/table. B. DO NOT continue using if you smell unusual odors, or have headaches, nausea ,or dizziness. C. DO NOT store any combustible material, gasoline, and any other flammable vapors/liquids in the vicinity
of the fire pit/table. D. Matches, paper, garbage, or any other material must not be thrown onto the fire pit/table. E. DO NOT use the fire pit/table if any part of it that has been submerged in water. Immediately call a quali-
fied professional service technician to inspect the fire pit/table and to replace any part of the control system that has been submerged in water.
CLEANING AND MAINTENANCE
A. Always shut off the gas to the fire pit/table while performing service work. B. Allow the fire pit/table to cool before servicing. C. The Fire Pit should be inspected regularly by the owner/operator. Excessive debris can build up on this
fire pit/table system including leaves, dirt and other materials. It is critical that all control components,
propane air mixer, and burner are maintained free of internal obstructions, and for the surrounding area
to be kept clean of debris. D. The burner assembly must be replaced prior to the fire pit/table being put into operation if it is evident
that the burner is damaged. Contact (951)-805-0314 E. The owner/operator should perform periodic visual checks of the burner flames and pilot flames (if appli-
cable). The burner flames should be blue at the base with a combustion of blue/yellow at the body and
tips. The pilot (if applicable) should be a steady flame, touching the electrode/thermocouple. Contact a
qualified service person for maintenance. This appliance should be inspected before use and at least an-
nually by a qualified service person
Note: Keep the surrounding area at the base of the Fire pit clean and free of obstructions at all times. Keep
the burner pan, decorative media (fire glass) and other items clean and free of debris that may cause obstruction.
Caution: HOT DURING OPERATION AND AFTER USE. Children must be supervised when in the vicinity of this fire pit/table. Serious injury may occur!
DCI LLC All Rights Reserved: For technical support call (951)-805-0314 3
IMPORTANT INFORMATION BEFORE OPERATION
WARNING: DO NOT OPERATE THE FIRE PIT/TABLE IN THE RAIN!!!
WARNING: Flame adjustment valves are not on all models and may vary in location and style. Owner/
operator must become familiarized with the controls before operation. CAUTION: Installation and maintenance must be done by an NFI Certified or other qualified professional in-
staller. Read these instructions before installing this fire pit/table. Owner/operator must understand all safety precautions and warnings contained in this manual.
A. FOR OUTDOOR USE ONLY. B. When shutting the fire pit/table off; be sure to turn the control valve to the full off position. C. WARNING: CARBON MONOXIDE POISON MAY LEAD TO DEATH. DO NOT MODIFY THIS FIRE PIT/TABLE OR
ITS CONTROLS, EXCEPT AS PROVIDED FOR IN THIS MANUAL. Any other un-approved modification may be
dangerous. Improper installation or use of the Fire Pit can cause serious injury or death from fire, burns,
explosions, or carbon monoxide poisoning.
BE CAREFUL
If not installed and used correctly per these instructions,
this product may cause serious injury.
D. Check state and local codes to determine if the fire pit/table is allowed in your area before installation. E. The manual valve allows adjustable flame height and heat output. During operation, the flame height set-
ting must always be high enough for the flame to be clearly visible.
FIRE PIT CLEARANCE TO COMBUSTIBLES AND OVERALL DIMENSIONS
Side walls and fire pit/table surroundings: 48” from each side of the Fire Pit Table Ceiling: Nothing should be located above the fire pit/table Flooring: 0” (This unit may be installed on a concrete slab, wood deck, or other level floor type).
Note: Nothing should be above the Fire Pit Table
48”
CLEARANCE
48”
CLEARANCE
NOTE: Keep vent opening at the base of the unit clear on all sides for proper ventilation beneath the fire pit/table.
DCI LLC All Rights Reserved: For technical support call (951)-805-0314 4