d&b audiotechnik TI 320 1.1 en, 10D, D20, D80, 30D Quick Start Manual

TI 320 1.1 en Beckhoff Module for d&b 10D, 30D, D20 and D80 amplifiers
Quick start guide
1. Introduction
Requirements
Ethernet-compatible d&b amplifiers (10D, 30D, D20 or
D80) with Firmware V2.02.00 or higher.
Beckhoff TwinCAT3 PLC v3.1.4020 or higher.Embedded PC CX5120 or a system with higher
performance.
Microsoft Windows Embedded Standard 7 or Microsoft
Windows 7 Professional.
Compact Flash card with a capacity of at least 8 GB.Beckhoff d&b Amplifier example project.
Plug-in capabilities
Device
Power the amplifier on and off
Track the amplifier's Power and Error status
Read the amplifier name
Outputs
Channel output gain and mute control
Supervise each channel's error status individually
Amplifier Presets
Backup and load presets
Track the modified status of currently active preset
Monitoring
Enable/disable Input monitoring for each individual analog and digital input
Enable/disable Load monitoring for each individual output
Input fallback and override settings
2. Getting Started
1. Start the TcOcaService using the Windows Services Console:
a) Open the Windows Start menu and select
«Run...».
b) Type in «services.msc» on the command field
and click Ok.
c) Find «TcOcaService» on the list and open its
properties.
d) Start the service with the parameters «--log –
clear».
2. Click on the TwinCAT icon on the system tray and under «Tools», select «Event Viewer». By starting the TcOcaService with the «--log» parameter, a Logfile named «OCA Log» will become available. The names of all d&b Amplifiers discovered in the network will be listed in this Logfile.
3. Click on the TwinCAT icon on the system tray and choose
«TwinCAT XAE». This will start TwinCAT3
integrated as an extension of Visual Studio.
4. Open the provided TwinCAT project archive
«TwinCAT DB Sample Project.tszip». Several
POUs and Visualisations will become available.
5. Verify that you have the necessary licenses. Valid TC1000 and TF1800 licenses are required.
6. The MAIN POU contains a string variable called
«sDevName». Set the value of this string to match
the name of one of the Amplifiers discovered by the TcOcaService. We recommend copying the name directly from the TwinCAT Event Viewer.
7. Click on «Activate Configuration». Confirm all dialogs with «OK».
8. Login to the PLC and start the program.
9. To display the Visualisation in Full-screen mode, start the PLC HMI task. For details on the PLC HMI please refer to the Beckhoff TF1800 manual.
3. Module details overview
The TwinCAT framework enables system integrators to define their own custom user interface. The following screenshots of the d&b Amplifier demo project give an insight into the supported functionality.
Amplifier settings/status
[1] Power switch. [2] Amplifier's name. [3] Amplifier's RemId. [3] Amplifier status.
Input monitoring
[1] Enable/disable Input monitoring for each analog
input.
[2] Enable/disable Input monitoring for each digital
input.
[3] Fallback mode (Off, Manual, or Auto). [4] Enable/disable Fallback. [5] Override mode (Off, Manual, or Auto). [6] Enable/disable Override.
TI 320 1.1 en 2
Loading...
+ 1 hidden pages