Daxten GALAXY Installation And Operation Manual

Page 1
Galaxy
TM
Installation and Operation Manual rev 1.1
Page 2
2
LIMITED WARRANTY
Daxten warrants the Galaxy™ to be in good working order for one year from the date of purchase from Daxten or an authorised dealer. Should this product fail to be in good working order at any time during this one year warranty period, Daxten will, at its option, repair or replace the Unit as set forth below. Repair parts and replacement units will be either reconditioned or new. All replaced parts become the property of Daxten. This limited warranty does not include service to repair damage to the Unit resulting from accident, disaster, abuse, or unauthorised modification of the Unit, including static discharge and power surges.
Limited Warranty service may be obtained by delivering this unit during the one year warranty period to Daxten or an authorised repair centre providing a proof of purchase date. If this Unit is delivered by mail, you agree to insure the Unit or assume the risk of loss or damage in transit, to prepay shipping charges to the warranty service location, and to use the original shipping container or its equivalent. You must call for a return authorisation number first. Under no circumstances will a unit be accepted without a return authorisation number. Contact an authorised repair centre or Daxten for further information
ALL EXPRESS AND IMPLIED WARRANTIES FOR THIS PRODUCT INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO A PERIOD OF ONE YEAR FROM THE DATE OF PURCHASE, AND NO WARRANTIES, WHETHER EXPRESS OR IMPLIED, WILL APPLY AFTER THIS PERIOD. SOME COUNTRIES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
IF THIS PRODUCT IS NOT IN GOOD WORKING ORDER AS WARRANTED ABOVE, YOUR SOLE REMEDY SHALL BE REPLACEMENT OR REPAIR AS PROVIDED ABOVE. IN NO EVENT WILL DAXTEN BE LIABLE TO YOU FOR ANY DAMAGES INCLUDING ANY LOST PROFITS, LOST SAVINGS OR OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF OR THE INABILITY TO USE SUCH PRODUCT, EVEN IF DAXTEN OR AN AUTHORISED DEALER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, OR FOR ANY CLAIM BY ANY OTHER PARTY.
© Copyright 2003. All rights reserved.
No part of this manual may be reproduced, stored in a retrieval system, or transcribed in any form or any means, electronic or mechanical, including photocopying and recording, without the prior written permission of Daxten.
Printed in Denmark Revision 1.1
NOTE: This equipment complies with the requirements of European EMC directive 89/336 EEC in respect of EN55022 Class B, EN 50082-1 and EN 60555-2. This equipment has been found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Page 3
3
Thank you for choosing the Galaxy ™ system, designed for Distributing and daisy chain high-resolution video signals over long distances via CAT 5 cables. By choosing Galaxy, you have assured that your installation is equipped for the ever-increasing demands made in a modern computer-based information environment.
The Galaxy system allows the info-computer to transmit this monitor image to a number of receiver monitors in large environments such as subway stations, bus terminals, airports, restaurants, malls, banks etc.
The Galaxy Tx1 is a base unit with one VGA output and one UTP output. The Galaxy Tx4 is a base unit with one VGA output and four UTP outputs. The Tx1 and Tx4 can be fitted with different option cards:
UTP-in Card for up to 125m distance
UTP-in Card for up to 300m distance
A skew compensator board
Sound board on request and requirements
Features
Up to 300 meters in one line without repeater
Up to 1000 meters with 10 Galaxy Repeaters in 800 x 600 @ 75 HZ
Compatible with the Galaxy Rx60 Receiver for building in and the external
Rx60, Rx125 or Rx300 version
Sound or remote operation of monitors ON/OFF on request
Operation
The Galaxy is simple to operate, but need planning before installation, to obtain the best picture quality.
Compatibility
This product has been tested with a wide variety of hardware. However, it is impossible to guarantee correct operation with every monitor currently on the market.
The Galaxy is compatible with the following equipment:
Monitor: VGA, SVGA, XGA, SXGA, UXGA
Computers: all computers using a HD-15 VGA output and standard VGA signals
RGB and two sync signals H/V
INTRODUCTION
Page 4
4
This manual describes the Galaxy installation and operation of the Galaxy system. All versions of the models are listed here
Package Content
The Galaxy Tx1 starter package includes: (1024-01TK)
1 Galaxy Tx1 (1024-01T) 1 Power Transformer and mains lead* (9014-00F-AW) 1 VGA Cable (2051-02T)
1 User manual
OR
The Galaxy Tx4 starter package includes: (1024-04TK)
1 Galaxy Tx4 (1024-04T) 1 Power Transformer and mains lead* (9014-00F-AW) 1 VGA Cable (2051-02T)
1 User Manual
OR
The Galaxy Repeater Station Tx1 125M includes: (1024-01TEHK)
1 Galaxy Tx1 (1024-01T) 1 Expansion Card (1024-00TUH)
1 Power Transformer and mains lead* (9014-00F-AW) 1 User Manual
OR
The Galaxy Repeater Station Tx4 125M includes: (1024-04TEHK)
1 Galaxy Tx4 (1024-04T) 1 Expansion Card (1024-00TUH) 1 Power Transformer and mains lead* (9014-00F-AW) 1 User Manual
power supply type depends on market .
GETTING STARTED
Page 5
5
Package Content
The Galaxy Repeater Station Tx1 300M includes: (1024-01TEK)
1 Galaxy Tx1 (1024-01T) 1 Expansion Card (1024-00TU)
1 Power Transformer and mains lead* (9014-00F-AW) 1 This User Manual
OR
The Galaxy Repeater Station Tx4 300M includes: (1024-04TEK) 1 Galaxy Tx4 (1024-04T) 1 Expansion Card (1024-00TU) 1 Power Transformer and mains lead* (9014-00F-AW) 1 User Manual
OR
The Galaxy Rx60 receiver includes: (1024-01RMK) 1 Galaxy Rx60 (1024-01RM) 1 Power Transformer and mains lead* (9014-00F-AW) 1 User Manual
OR
The Galaxy Rx60-PCB includes the following: (PCB-GALRX-60) 1 Galaxy Rx60 (PCB-GALRX-60)
OR
The Galaxy Rx125 receiver includes: (1024-01RHK) 1 Galaxy Rx125 (1024-01RH) 1 Power Transformer and mains lead* (9014-00F-AW) 1 User Manual
OR
The Galaxy Rx300 receiver includes: (1024-01RK) 1 Galaxy Rx125 (1024-01R) 1 Power Transformer and mains lead* (9014-00F-AW) 1 User Manual
Page 6
6
Accessories
With the packages the units can be set up. It is however necessary to get additional modules and cables to connect the units:
Part Part number
Galaxy Tx1 1024-01T Galaxy Tx4 1024-04T Galaxy Rx60 1024-01RM Galaxy Rx125 1024-01RH Galaxy Rx300 1024-01R Galaxy Repeater Tx1 125m 1024-01TEH Galaxy Repeater Tx1 300m 1024-01TE Galaxy Repeater Tx4 125m 1024-04TEH Galaxy Repeater Tx4 300m 1024-04TE Expansion Card 125m for daisychain 1024-00TUH Expansion Card 300m for daisychain 1024-00TU External 30ns skew compensation unit KIT 1024-00S30-EXT-K Remote PCB for building in LCD monitors max 60 meter from Tx station
PCB-GALRX-60
Page 7
7
Gala xy Tx 1
UTP O UT
VGA IN

Gala xy Tx 4
OUT 3 OUT 2
OUT 4
OUT 1
VGA IN
Rear view of Galaxy TX 1and Tx4
Front view of Galaxy Tx4
UTP I N
9-24 V DC
EQ G AIN
R
G
B
DC
9-20V
UTP in
VGA out
-
+
Front view of Galaxy RX 60
Distance label
Galaxy Rx60 DC jack connectors—
There are two DC jack connectors on the Rx60, both of which can accept power supplies giving between 9-20vdc. The second jack connector is available for use in contexts where a TFT screen, for example, is powered by a 19vdc mains adapter. Since the Rx60 only uses 200ma, the TFT mains adapter will normally be able to power the Rx60 as well. This is done by plugging the DC jack from the TFT mains adapter (possibly with the help of a DC jack adapter) into one of the Rx60 DC jack connectors. A jack-jack cable, which must be obtained from a stockist or constructed from components, can then be used to take the 19vdc current from the Rx60 to the TFT screen. This obviates the necessity of a second mains adapter for the Rx60.
CONNECTORS ON GALAXY
Page 8
8
Applications
Tx1
Rx60
VG
A
i
n
VGA out
UTP OUT
UTP
IN
V
G
A
o
u
t
9-24
V DC
9
-
2
4
V
D
C
Tx1
Tx1 w/UTPin
VGA in
VGA out
UTP OUT
UTP
IN
V
G
A
o
u
t
9-24
V DC
9
-
2
4
V
D
C
Figure 2: Galaxy Tx1 connected to one Galaxy TX1 with UTP In module
Page 9
9
Tx4
Tx4 w/UTPin
Tx4 w/UTPin
Tx1 w/UTPin
Rx60
Rx60
Rx60
Rx60
Rx60
Rx60
Large-scale system
Voyager 125 Local
Tx1 w/UTPin
UTP
UTP in
Voyager 125 Remote
UTP
UTP
OUT
M
o
n
i
t
o
r
Galaxy Tx1 with UTP in module used as repeater for high resolution 1200 X 1600 over long distance in a Voyager 125 system
Page 10
10
Galaxy Transmitter and Galaxy receivers.
When planning large installations please chose the right boxes and configuration. When working with Daisy chains please make a drawing with cable lengths of your system and give the boxes a numbers so it is possible to locate the boxes on the drawing. Write down the configuration for the box if it contains a delayline so you can put in a spare box with the right settings.
Begin installation from the info-computer. Connect a Galaxy Tx1 or Tx4 (without UTP-in module) to the Info-PC. Put on a still test image on the info-computer.
A) Connect a Rx60 receiver to the first Galaxy. Connect a monitor to the Rx60;
adjust the R G B for the best picture.
B) OR Connect a Tx1/4 Repeater Station or a Rx125/300; adjust the EQ and Gain
for the best picture.
The Galaxy products are made in many versions for special requirements: With and without UTP in modules, with and without delay lines. The UTP in modules differ in equalizing: the 125M-module work with UTP lines up to 125M. For longer distances use the 300M Version with UTP-in for distances between 125 and 300 m
The 125M version has no inside distance switches. The 300 version has inside switches for distance adjustment.
Galaxy Repeater station TX1/TX4 300M and Rx300
Please Notice! The distance of the cat5 cable is set by micro switches inside the Galaxy Repeater 300M/Rx300.
BEFORE INSTALLATION
PROCEDURE FOR INSTALLATION
R G B 200-300 M 100-200 M 0-100 M
R
G
B
2
0
0
-
3
0
0
M
1
0
0
-
2
0
0
M
0
-
1
0
0
M
Page 11
11
As default the distance is set to maximum 300 M. Changes in distance settings are made inside the Tx Repeater/Rx300.
If the picture has visible vertical shadows it can be improved by adding internal or external delay line.
To get the highest picture quality connect a monitor direct to the Tx units to calibrate the EQ and Gain before moving on to the next repeater or receiver box. After installation adjustments should only be carried out on the monitor settings and Rx60/125/300 ends otherwise the pictures on the other boxes will change.
Video
No picture on the Tx1.
1) Is the Green LED lit on the unit? No power, no transmission
2) Bad picture quality with very long transmission lines—Daxten can, on special order deliver Cat 5E cable optimized for VGA transmission. Adding a delay line (skew delay compensator) will also help.
3) Is this receiver fitted with an UTP-in card ? Add one.
4) Is the transmitter first unit working? Check local out.
5) Check the cables.
6) No picture will be showed if you use the VGA input on a Tx fitted with an UTP-in Module.
7) Check the UTP cabling if you have problems with the colours.
8) If the picture shakes and contains noise you have to isolate the problem by removing the UTP cables to some of the UTP units in order to find the line and box with the problems. Check the ground. Call an electric technician with grounding skills and test equipment for proper grounding.
9) The UTP Cables are made the same way as used for networking
10) None of the cables for the Information system can be used to carry other data or be connected to any networking equipment.
11) Noisy picture if ground problems occur over long distance. These problems are solved by experiments with grounding the housings or adding ground loop isolators. If the voltage potential is large enough, your equipment won’t be able to handle the excess voltage and one of your ports will be damaged. You can’t test for ground loops. You don’t know you have one until picture fails. A ground loop is a current across a conductor, created by a difference in potential between two grounded points, as in two buildings connected by a run of data lines. When two devices are connected and their potentials are different, voltage flows from high to low by travelling through the UTP cable.
TROUBLE SHOOTING
Page 12
12
How long distance is it possible to make one line? The Tx1 and Tx4 has been tested with 900 meters without delay lines at 800x600. To go long distance you need a delay-line compensator to restore the signal.
In information systems it is common to work in low resolution. Users are in distance of the display and need larger types. Daylight makes it difficult to work with monitors and displays outdoor. Using smaller displays needs larger types. Try reading your information in two meters is it readable?
If you are running long distance and high resolution pictures with small text you might see that Black don’t turn into White. The texts on the monitor have small shadows Put on a test image on the central computer. The best test picture is made of red green and blue lines above each other. If the 3 colour lines do not match on the monitors you need delay-line compensating equipment.
The improvement can be made using an internal or external skew compensator. The Tx1 and Tx4 repeaters can use an internal compensator type Galaxy-TXSK.
Maintenance and repair
The units do not contain any user-serviceable parts inside. Any malfunction of the unit should be reported to a factory-authorised repair centre for service. Any discrepancies in the operation of the unit according to this manual should be reported to the Technical Support Department of Daxten.
Technical support
If you cannot determine the nature of a problem, please call Daxten and ask for Technical Support.
If possible call from a phone located near the unit - we may be able to solve your problem directly over the phone. If we cannot solve your problem, and the fault is supposed to be in the unit, we will issue a Return Material Authorisation (RMA) number that must appear on the outside of all returned products. The unit should be double-packed in the original container, insured, and shipped to the address given to you by our Technical Support representative.
SERVICE INFORMATION
ADDING A DELAYLINE
Page 13
13
Galaxy Tx1
Size 215 x 105 x 44 mm (8.46 x 4.13 x 1.73 in.) Weight 0.80Kg (1.77lbs) Power Consumption Max. 700mA with UTP-in module Recommended Input Power Regulated DC 12V/1,3A or 9V/2A
Galaxy Tx4
Size 215 x 105 x 44 mm (8.46 x 4.13 x 1.73 in.) Weight 0.80Kg (1.77lbs) Power Consumption Max. 700 mA with UTP-in module Recommended Input Power Regulated DC 12V/1,3A or 9V/2A
Galaxy Rx60
Size 160 x 65 x 28 mm (6.30 x 2.56 x 1.10 in.) Weight 0.35 Kg (0.77lbs) Power Consumption Max. 120 mA Recommended Input Power Regulated DC 12V/1,3A or 9V/2A
Please note that these specifications are subject to change without prior notice.
APPENDIX A. GENERAL SPECIFICATIONS
Page 14
Page 15
Page 16
www.daxten.com
IRELAND
Daxten Ltd Unit 5 Distribution Centre Shannon Free Zone County Clare Ireland
info.ie@daxten.com
Tel: +353 (0)61 23 4000 Fax: +353 (0)61 23 4099
ENGLAND
Daxten Ltd 4 Harp Business Centre Apsley Way London NW2 7LW United Kingdom
info.uk@daxten.com
Tel: +44 (0)20 8438 3800 Fax: +44 (0)20 8438 3899
UNITED STATES
Daxten LLC 1579 Lexington Road Green Oaks, IL 60048 USA
info.us@daxten.com
Tel: +1 (847) 816 1337 Fax: +1 (847) 816 4558
SPAIN
Dakota Computer Solutions S.L. C/Francisco de Vitoria 19 Entreplanta 50008 Zaragoza Spain
info.es@daxten.com
Tel: +34 9 76 210 256 Fax: +34 9 76 219 943
GERMANY
Daxten GmbH Salzufer 16, Geb. B 10587 Berlin Germany
info.de@daxten.com
Tel: +49 (0)30 8595 37-0 Fax: +49 (0)30 8595 37-99
DENMARK
Daxten Finlandsgade 33 8200 Aarhus N Denmark
info.dk@daxten.com
Tel: +45 7022 5411 Fax:
FRANCE
Daxten B.P. 04 77, Route de Cheptainville F-91630 Marolles-en-Hurepoix France
info.fr@daxten.com
Tel: +33 (0)1 64 56 09 33 Fax: +33 (0)1 69 14 88 34
SWEDEN
Daxten AB Södermälarstrand 29, 6tr 118 25 Stockholm Sweden
info.se@daxten.com
Tel.: +46 (8) 692 65 73 Fax.: +46 (702) 636 982
AUSTRIA
Daxten Österreich GmbH. Künstlergasse 11/4 A-1150 Wien Austria
info.at@daxten.com
Tel:+43 (0)1879 7765 Fax:+43 (0)1879 776530
Loading...