DAXOM UKDAX-16EDT, UKDAX-20EDT, UKDAX-12EDT, UKDAX-18EDT, UKDAX-24EDT Installation And Operating Manual

...
Dear DAXOM User
In order to perform devices function properly and for your safety follow the instructions mentioned in the user manual of the device during the mounting and the usage of the device.
Please keep this user manual in good conditions for future reference.
1. Device installation must be made by authorized personnel according to instructions that aredetermined inside this manual.
2. Start-up of device must be made by Authorized Service. Do not try to operate the device by yourself.
3. Connection of water and heating installation of the device must be made as safety.
4. Device can operate with the voltage determined inside this manual according to its model. Suitable system voltage must be provided.
5. When it is supplied electric distribution from any electric resource (like generator) except city electrical distribution network, must be sure that necessary conditions are provided for safety operation of the device.
6. Energy must be provided to device with suitable cable diameter determined inside this manual. Residual Current Device and grounding must definitely place.
7. Installation of the device must not be made to humidity places and places that can be wet from external factors.
8. Do not keep inflammable, explosive or easy flammable materials and objects near the device.
9. This “INSTALLATION AND USER MANNUAL” is supplemental part of the product. Please keep it for apply when it is necessary. Contact with authorized service agency for the new copy in case of lost or damage.
10. This device must only be used as suitable as for its purpose. Producer reject all kinds of liabilities that places or not places in the agreement for damage property or injury indented to person and animals which cause because of consumer wrong using, installation , setting and maintenance.
11. After you unpack the device, be sure that content is in good position and complete otherwise contact with the sales agency that you have purchased the device.
12. Safety valve outlet must be connected to suitable discharge and ventilation system. Company rejects liability in case of any damage that occurs because of any intervention to safety valve.
13. Remove all packing wastes carefully without giving damage to human and environment health.
1. SAFETY WARNINGS
14. In case of water leakage happens, water feed must be close and authorized service agency must be immediately informed.
15. Hydraulic system operation pressure must be between 1 and 2 bars therefore it must not exceed 3 bars. In case of need, pressure can be reset as shown under the paragraph “FILLING THE SYSTEM”.
16. If the device will not used for a long time, perform following points are suggested.
Bring switch of the device OFF position. Close taps both heating and hot water network. Discharge heating and hot water network cycle for preventing
freezing.
17. Device cannot be used by children or disabled people without helper.
18. In case of having smoked or burning smell originating from device, make switch of the “OFF” position and contact with authorized service agency.
19. Do not touch the device with wet hand or when outside of device is wet.
20. Do not use substances such as detergent and thinner for the cleaning of the device. Clean outside of the device with damp –dry fabric.
21. Superheated water can be flow when the hot water is firstly opened.
22. The lifetime of the device which is determined by Ministry of Custom and trade is 10 years.
1. Adjust ambient temperature according to your need. Increasing 1 degree of ambient temperature increases your energy consumption about %6.
2. Having homogeneous heating at parts according to intended use that is placed at the heating place, increases saving.
2. SUGGESTIONS FOR ECONOMICALLY USED
3. Adjustable needed temperature value for every part by using thermostatic valve for radiators increases the saving but using of room thermostat and thermostatic valve at the same time can create problem.
4. While using of thermostatic valve and room thermostat,for sensing the temperature correctly, make suitable position of objects such as curtain and goods that influence ambient airstream.
5. Room thermos tad must be far away from goods and devices which influences sense of ambient real temperature and must be place to suitable height.
6. Ventilation of heated environment very long time increase the energy lost. Short time ventilation must be made. If it is needed to make long time ventilation, closing valve of ambient radiator or turn the device down provide energy saving.
7. At night time or when you are not at home while turning device down provides keeping temperature at definite level also can saving.
8. Adjustment of device operation temperature setting according to exterior temperature provides saving.
9. Adjustment of tap water temperaturesetting according to your need as not needed make lukewarm with cold water provides saving.
10. Use water as consciously. Consciously using water increase saving.
3. CONFIGURATION OF THE DEVICE
Technical
Specifications
Power (kW) Dimensions
L*W*H (mm)
Weight (Kg)
Expansion
Tank (l)
Δt=25 oC Hot Water
Amount (l/min)
Model
3~400 V.50 Hz
Electrical Heating and Hot Water
UKDAX-10EDT 10 700*400*250 26
7
5,8
UKDAX
-
12EDT
12
700*400*250
26 7
6,9
UKDAX
-
16EDT
16
700*400*250
26 7
9,2
UKDAX-18EDT 18 700*400*250 26
7
10,4
UKDAX-20EDT 20 700*400*250 26
7
11,5
UKDAX-24EDT 24 700*400*250 26
7
13,8
UKDAX-30EDT 30 700*450*320 34 10 17,2
UKDAX-36EDT 36 700*450*320 34 12 17,2
UKDAX-40EDT 40 700*450*320 34 12 17,2
UKDAX-48EDT 48 700*450*320 34 12 17,2
1~220 V.50 Hz
Electrical Heating and Hot Water
UKDAX-10EDM 10 700*400*2
26
7
5,8
UKDAX-12EDM 12 700*400*2
26
7
6,9
UKDAX-16EDM 16 700*400*2
26
7
9,2
UKDAX-18EDM 18 700*400*2
26
7
10,4
3~400 V.50 Hz
Only Electrical
Heating
UKDAX-10ETT 10 700*400*2
23,8
7
-
UKDAX-12ETT 12 700*400*2
23,8
7
-
UKDAX-16ETT 16 700*400*2
23,8
7
-
UKDAX-18ETT 18 700*400*2
23,8
7
-
UKDAX-20ETT 20 700*400*2
23,8
7
-
UKDAX-24ETT 24 700*400*2
23,8
7
-
UKDAX-30ETT 30 700*450*3
31,8
7
-
UKDAX-36ETT 36 700*450*3
31,8 12
-
UKDAX-40ETT 40 700*450*3
31,8 12
-
UKDAX-48ETT 48 700*450*3
31,8 12
-
1~220 V.50 Hz
Only Electrical Heating
UKDAX-10ETM
10 700*400*2
23,8 7
-
UKDAX-12ETM
12 700*400*2
23,8 7
-
UKDAX-16ETM
16 700*400*2
23,8 7
-
UKDAX-18ETM
18 700*400*2
23,8 7
-
3~400 V.50 Hz
Only Electrical Heating Without Pump and
UKDAX-72ETP
72 800*450*320 37,8
-
Technical Specification
s Radiator
Bath Water
Min.Operation Pressure
bar
1
0,5
Max.Operation
bar
3
10
Min.Setting
oC 35 35
Max.Setting
oC 80 55
Connections
¾
½
Boiler installation must be done by authorized personnel.
5. INSTALLATION OF BOILER
Obey minimum distance that is anticipated for installation in order to reach the device for making regular maintenance.
5. 1 INSTALLATION CONDITIONS AND SAFETY WARNINGS
For the right position of the device;
Do not place on the cooker or similar cooking devices.
Do not leave combustion products inside device installed room.
Heating sensitive walls (for example wooden walls) must be protected with steady insulation.
Before the installation, wash the all system pipes carefully for removing any residual things that can give damage to operation of the device. In case of leakage cause from overpressure of heating system, place water colleting channel that has suitable discharge pipe under safety valve. There is no need to have safety valve for tap water cycle but be sure that waterworks is not exceed the 6 bar. If you suspect about this, you can have pressure reduce valve installed.
Device installation place must be far way from blockers, obstruction parts and bulges during repairing and maintenance.
Electric connection of the device must be made with suitable cable, fuse and residual current device and grounding absolutely must be made.
Installation wall of the device must be as durable as carrying the weight of the device.
From under and upper part of the device ,drill min 2 pcs suitable diameter holes to the place which is chosen as suitable according to clauses determined above. Fasten suitable fixing plugs to holes. Screw the device to holes from up and down. Screw from more point when it is needed.
Heating system must be drawn with suitable diameter pipe for providing enough circulation of heating water. Choosing radiatorpipes smaller than it is
5.2 WALL INSTALLATION OF DEVICE
5. 2.1 Connection of Heating System and Plumbing