Dear Daxom User,
In order to perform device’s function properly and for your safety
follow the instructions mentioned in the user manual of the device during the mounting and the usage of the device. In case of an unauthorized mounting and maintenance, the device will be void from warranty cover. In addition to that, our company will not be responsible from failure or an accident that may occur in the device. Please keep this user manual in good conditions for future reference.
The mounting of the water heater should be performed by an authorized person. Please contact with our authorized dealers who are powered by the authorized gas administration (EGO, İGDAŞ,
BOTAŞ, İZGAZ, etc). Do not attempt to operate the device by
yourself. In case of you use LPG gas, do not mount your water heater in places below the ground level. Check whether your water heater conforms to the gas type you will use or not. Perform the hose connection in a safe way. Be careful not to mount the water heater to the environments such as clean air/ ventilation spaces of waste chimney, lightning and etc. Consult with the authorized service or the companies about this matter. The device operates with 220-240Volt voltage. Ensure the network voltage is 220-240 Volts. Your water heater has no regular pipe connection since it is a hermetic one. Therefore it is mandatory to use the system of fresh air/waste gas pipe supplied with the device. Never connect it to the regular chimneys. The life time of the water heater which is determined by department of industry is 10 years.
Safety Warnings
Thanks to its feature of digital constant water setting, the water temperature will remain constant in the degree you set. The fuel efficiency is reduced in low water temperature as your device can operate in the desired constant water temperatures. By the automatic water controlled on/off system, when the water valve is opened, the water heater will be ignite automatically and the hot water flow will be provided. When the water valve is closed, the water flow will stop and the flame will be off automatically. Thanks to its feature of operating with low pressure water, it will not be affected by the low water pressure that occurs in the high apartment flats. 2 mSS The temperature control adjustment buttons make for users easy to obtain different water temperature that they desire. By the high pressure safety system, when the water pressure is
higher than it’s needed, safety valve will discharge the excess water
by become a part of a activity. By the high temperature safety system, in case of the water getting hotter than it is needed, the gas will be cut off automatically and the damage of the water heater will be prevented. The flame instability is prevented and the water is cooled after the flame is off with the features of blowing inside the water heater before the ignition (air fan blows air for 2~4 seconds before ignition) and the blowing after service (air fan will go on blowing air for 10 seconds after the water stops and the flame is off). Thanks to the safe and reliable design of the combustion system, the air is taken from outside by the fan for the purpose of the combustion and it is sent out again after the combustion. By the system of continuous electronic ignition, 100% success is achieved in ignition. The device is equipped with the multi-purpose safety system. Even if the power is supplied to the water heater again in power failure, fan failure, the blocking of the waste gas pipe or strong reverse wind blowing the gas will be automatically cut and the automatic ignition system will be disabled. In this case the water heater will need to be restarted.
1. THE FEATURES AND THE CHARACTERISTICS OF YOUR WATER HEATER
LCD display provides you to see the water temperature that you set. When you press the On/Off button you can see the water flowing, the fan turning, the temperature you set and the occurrence of the flame on the LCD display.
UKDAX – 11ST MODEL
2. THE CONFIGURATION OF YOUR WATER HEATER .
Warning: The mounting of the water heater should be performed by an authorized person. Please contact our authorized dealers who are powered by the authorized gas administration (EGO, İGDAŞ,
BOTAŞ, İZGAZ, etc). Do not attempt to operate your device by
yourself.
Model:DAXOM
Type: UKDAX-11ST
Device type
C12
Gas category
II2H3 B/P
Gas type
LPG(G30/G31)
Natural Gas(G20)
Gas input pressure
30mBar
20mBar
Fan Power
36 W
Water flow(Δt=25K)
11 l/min
11 l/min
Nominal power P
19,15 KW
Nominal load Q
22,8KW
Gas consumption
2,12 kg/h
2,12 kg/h
Water pressure Min.
0,2 bar
Max.
10 bar
Electrical connection
220-240 Volt AC 50Hz 36 W IP 44
Minimum water flow
2,7 lt/dk
Normal heat load
22,8 KW
Net weight
9,8 kg
Dimensions
522 x337 x 143
Connections
Cold water
1/2''
1/2''
Hot water
1/2''
1/2''
Natural gas
1/2''
1/2''
Waste gas
Ø60
Ø60
Air channel
Ø100
Ø100
3. TECHNICAL INFORMATIONS
4. THE MOUNTING OF YOUR WATER HEATER