Davis Instruments Multi-purpose Shelter, MPS 7728 User Manual

Product #7728
M
ULTI-PURPOSE
HELTER
The weather-resistant Multi-Purpose Shelter (MPS) may be used to protect a number of system components from the elements.
CAUTION:
Please note that we have made every attempt to design and manufacture a safe product, but Davis Instruments assumes no liability for any injury or damage caused directly or indi­rectly by the installation or use of this product.
C
OMPONENTS
The MPS includes the following components. Please make sure that you have all the listed components before continuing.
C
OMPONENTS
Page 2 Multi-Purpose Shelter
The hardware kit included with the MPS includes the following components. Please make sure that you have all the components before continuing.
H
ARDWARE KIT COMPONENTS
The ground lug kit included with the shelter includes the following compo­nents. Please make sure that you have all the components before continuing.
G
ROUND
L
UG
K
IT
C
OMPONENTS
T
OOLS
AND
M
ATERIALS
N
EEDED
FOR
I
NSTALLATION
You may need some of the following tools and materials in order to install the shelter.
System Components
You will need the various system components you plan to install inside the shelter. Some sample installation configurations are shown in “Sam­ple MPS Configurations” on page 3.
Medium Flat Head Screwdriver
Medium Phillips Head Screwdriver
Wrench or 3/8" Nut Driver
Large Adjustable Wrench (1 3/8" Opening)
Wire Cutter
Wire Stripper or Knife
Pliers
Electrical Tape and/or Silicone Caulking
Double-Sided Tape
Attaching Cable Strain Reliefs Page 3
A
TTACHING
C
ABLE
S
TRAIN
R
ELIEFS
Attach both strain reliefs to the MPS as shown below. You will need to install the strain reliefs before running cables into the MPS. Secur e the strain reliefs by tightening the lock nuts. Do not tighten the compression nuts until you have completed your installation (see “Securing the Cables” on page 12).
I
NSTALLING
S
TRAIN
R
ELIEFS
S
AMPLE
MPS C
ONFIGURATIONS
The illustrations below show three sample MPS installations. Consult the installation manuals supplied with system components for wiring instructions.
Console, Sensor Interface Module (SIM), and Short-Range (SR) Modem
The illustration below shows an MPS installation which includes the console, SIM, and SR Modem. When installing, make sure the indicated cable tie mounts are attached to the MPS so the centers of the mounts are 1-1/4" (32 mm) from the bottom of the shelter.
C
ONSOLE
, SIM, SR M
ODEM
I
NSTALLATION
Page 4 Multi-Purpose Shelter
Console, Sensor Interface Module (SIM), and Link isolator
The illustration below shows an MPS installation which includes the console, SIM, and Link Isolator. Make sure the indicated cable tie mounts are attached to the MPS so the centers of the mounts are 1-1/4" (32 mm) from the bottom of the shelter.
C
ONSOLE
, SIM,
AND
L
INK
I
SOLATOR
, I
NSTALLATION