Davis 7705 Installation Manual

S
ECOND SOLAR PANEL
FOR EZ-S
OLAR POWER KIT
This manual describes how to install and use the Second Solar Panel for the EZ-Solar Power Kit. The second panel is for use in far northern or southern lat­itudes, where wintertime light is limited, as well as other locations with lim­ited solar exposure. This panel doubles the amount of light-gathering capability of your solar powered EZ-Mount system. It includes a solar panel and regulator circuit.
Note:
The Second Solar Panel is only for use with the EZ-Solar Power Kit 7707.
CAUTION:
Please note that while we have made every attempt to design and manufacture a safe product, Davis Instruments cannot assume liability for any injury or damage caused directly or indirectly by the installation or use of this product.
Components
The EZ-Solar Power Kit includes the following components. Please be sure you have all listed components before beginning.
5/16"
Hex Nut
Cap
Cable Ties
Brace Clamp
5/16" x 2"
Carriage Bolt
Y-Terminal
Adapters
Power
Connectors
Solar Panel Shelter
Arm
Power
Cable
Product # 7705
Tools and Materials Needed
Tools and Materials Needed
You may need the following for this installation:
Adjustable Wrench or 5/16” Wrench
Flat Head Screwdriver
Pliers
Wire Cutters or Scissors
Installation Guidelines
The power cable supplied is six feet (6’, 1,8 m) long. Mount the Second Panel close enough to your EZ-Solar Power shelter for the power cable to reach without stressing the power cable connections.
Refer to the EZ-Solar Power Kit manual for complete mounting instructions.
Connecting the Cables
1. Open the EZ-Solar Power shelter door using a flat head screw­driver.
2. Disconnect the red/white wire from the positive (+) battery ter­minal.
3. Disconnect the black wires from the negative (-) battery terminal.
4. Install the Y-terminal adapters on the battery terminals. It is a tight fit, so you might want to use pliers to push the Y-terminal adapters onto the battery terminals.
5. Connect the red/white wires from the regulator to the Y-terminal adapter on the positive (+) battery terminal.
6. Connect the black wires from the regu­lator to the Y-terminal adapter on the negative (-) battery terminal.
7. Remove one round vent plug from the bottom of the EZ-Solar Power Panel.
8. Run the EZ-Solar Second Panel power cable up through the power panel vent hole.
9. Press the power cable’s vent plug into the vent hole until it locks into place.
Page 2
Y-terminal adapter installed on negative battery
terminal
Running the Second Solar Panel power cable
into the EZ-Solar Power shelter
Loading...