David White DT8-05P, DT8-05LP, DT8-05LS Owner's Manual

DT8-05P DT8-05LP DT8-05LS
DT8-05 Series Owner’s Guide
www.davidwhite.com
HOLD
R / L
V%
ON/OFF
FOR CUSTOMER SERVICE, PARTS
AND REPAIR CALL
(765) 581-4097
IMPORTANT: IMPORTANT : IMPORTANTE:
Read Before Using Lire avant usage Leer antes de usar
-2-
With David White your sights are set on precision and accuracy.
Congratulations! You’ve purchased a David White builder/contractor instrument, known throughout the world for precision and accuracy.
The purpose of this user’s guide is to acquaint you with the instrument, its components, safety, proper care and handling.
Our levels, level-transits and transits are constructed to withstand extremely rugged field use. Like all precision instruments, however, they should be treated with reasonable care to prolong life and accuracy.
All instruments are adjusted when they are shipped from the factory. It is the customer’s responsibility to check and to ensure instruments are adjusted prior to using.
David White is not responsible for errors caused by instruments that are out of adjustment.
Contact your distributor, dealer or David White for information on the nearest facility to check if your instrument is properly adjusted.
All specifications are subject to change without notice.
-3-
HOLD
R / L
OSET
V%
ON/OFF
2
3
12
13
7
10
9
16
15
14
17
18
4
6
8
7
5
11
1
-4-
GENERAL SAFETY RULES
!
WARNING
Read all instructions. Failure to follow all instructions listed below
may result in serious injury.
!
WARNING
When moving a tripod-mounted instrument, handle with care. Carry
only in an upright position. Do not carry over your shoulder or in a
horizontal position. Improper handling may result in instrument damage Handle the instrument by its base when removing from the case or attaching to a tripod. Never use force on any parts of the instrument. All moving parts will turn freely and easily
by hand.
DO NOT directly aim the telescope to the Sun to avoid injury to your eyes Check the leveling and indication accuracy of the instrument each time before using and
after longer transport of the instrument. Protect the instrument against moisture and direct sun light. DO NOT subject the instrument to extreme temperatures or variations in temperature.
As an example, do not leave it in vehicles for long time. In case of large variations in temperature, allow the instrument to adjust to the ambient temperature before putting it into operation. In case of extreme temperatures or variations in temperature, the accuracy of the instrument can be impaired.
This instrument contains many sensitive electronic components and is provided with protection against dust and moisture. Once dust or moisture enters into the instrument they will cause damage to the instrument. Therefore, after using in a humid
environment, the instrument must be dried immediately and stored in the instrument case.
Avoid any impact to or dropping of the instrument. After severe exterior effects to the instrument, it is recommended to carry out an accuracy check (see “Check”, page 8) each time before continuing to work.
Place the instrument in the provided case when transporting it over larger distances (e.g. in the car). Ensure that the instrument is correctly placed in the transport case.
When placing the instrument in the case.
When carrying instrument, always remove the instrument from the tripod when transporting or carrying it at the jobsite. If the instrument must be carried on the tripod,
hold the instrument as vertically as possible and keep it in front of you. Never carry the instrument horizontally over your shoulder.
When transporting instrument long distances, always place in the carrying case.
SAVE THESE INSTRUCTIONS
INTENDED USE
The instrument is intended for determining and checking precise measurements of heights, distances and angles.
This DT8-Series is design with the absolute encoding angle measuring system. Integrates optical, mechanical, electronic and computer technologies all in one, realizing a variety of functions including angle measurement, display and storage.
-5-
FEATURES
The numbering of the product features shown refers to the illustration of the instrument on the graphic page.
1. Carrying Handle
2. Hand Screw (2)
3. Telescope Objective Lens
4. Focusing Knob
5. Eyepiece
6. Target Sight-Collimator
7. LCD Display (2)
8. Circular Leveling Vial
9. Horizontal clamp Knob
10. Horizontal Tanget Fine Motion Screw
11. Optical Plummet with Focus (DT8-05P and DT8-05LS only)
12. Leveling Screw (3)
13. Tribrach Locking Lever
14. Telescope Vertical Clamp Knob
15. Vertical Tangent Fine Motion Screw
16. Battery Case
17. Tubular Plate Leveling Vial
18. 5/8-11 Thread Base
TECHNICAL DATA
Description
DT8-05P DT8-05LP DT8-05LS
Telescope
Objective aperture 1.77 in (45 mm) 1.77 in (45 mm) 1.77 in (45 mm)
Magnification 30X 30X 30X
Image Erect Erect Erect
Field of view 1° 30' 1° 30’ 1° 30'
Resolution 3” 3” 3”
Minimum focus 53 in (1.3 m) 53 in (1.3 m) 53 in (1.3 m)
Stadia constant 100 100 100
Electronic Angle Measurement
Angle measurement Absolute Encoding Absolute Encoding Absolute Encoding
Minimum reading 1” / 5” 1” / 5” 1” / 5”
Direction method H. Both sides,
V. Single side
H. Both sides, V. Single side
H. Both sides, V. Single side
Accuracy 5” 5” 5”
Unit of angle Deg / mil / gon / V% Deg / mil / gon / V% Deg / mil / gon / V%
Display LCD both sides LCD both sides LCD both sides
This instrument also display horizontal and vertical angles and realize conversion from vertical angle to gradient and compensation of vertical angle.
This series of electronic theodolite find wide applications in the Grade III and Grade IV triangle control measurement in national and urban projects, including engineering measurement in railway, highway, bridge, water conservancy, mining projects, etc. It can be also used in various engineering in construction, erection of large equipment and land register and topographic survey and various kinds of engineering measurement .
-6-
Description
DT8-05P DT8-05LP DT8-05LS
Tilt Sensor
Automatic Compensation Yes Yes Yes
Range of Compensation +/-3’ +/-3’ +/-3’
Plummet
Plummet Type Optical Laser Optical
Magnification
3X - 3X
Field of view -
Focusing range 20 in to infinity
(0.5 m to infinity)
- 20 in to infinity (0.5 m to infinity)
Reticle type Crosshair - Crosshair
Laser power ≤ 1mW
Facular diameter ≤ 2mm
Centering precision 1.5mm (instrument
height 1.5m)
Level Vial Sensitivity
Plate vial 30” per 2 mm 30” per 2 mm 30” per 2 mm
Circular vial 8’ per 2 mm 8’ per 2 mm 8’ per 2 mm
Display Operating Range
Operating voltage, typical 4.8 VDC 4.8 VDC 4.8 VDC
Batteries 4 x 1.5V (AA)/
Rechargeable Ni-MH
4 x 1.5V (AA)/ Rechargeable Ni-MH
4 x 1.5V (AA)/ Rechargeable Ni-MH
Operating Temperature range -4 °F to +122 °F
(-20 °C to +50 °C)
-4 °F to +122 °F
(-20 °C to +50 °C)
-4 °F to +122 °F (-20 °C to +50 °C)
Waterproof class IP 54 IP 54 IP 54
Weight 10.2 lb (4.6 kg) 10.2 lb (4.6 kg) 10.2 lb (4.6 kg)
Dimensions 6.5 x 6.1 x 13.4 in
(164 x 154 x 340 mm)
6.5 x 6.1 x 13.4 in
(164 x 154 x 340 mm)
6.5 x 6.1 x 13.4 in (164 x 154 x 340 mm)
Loading...