Davey EMX3600, EMX2400 Installation & Operation Instructions

Therapeutic
Mineral Water Sanitiser
Models: EMX2400 & EMX3600
Installation &
Operating Instructions
Please pass these instructions on to the operator of this equipment.
The installation of this product should be carried out by a person knowledgeable in swimming pool plumbing requirements following the installation instructions provided in this manual.
WARNING: Failure to follow these instructions and comply with all applicable codes may cause serious bodily injury and/or property damage.
EcoMineral
®
• To minimise the risk of gas build-up in the cell, you must ensure there is sufficient water flow through the cell when the unit is on and producing chlorine.
• It is essential that your pool pump circulates sufficient water through the cell to completely fill the cell with water during the chlorination process.
• Periodically check the safety flow switch to ensure it is free to move in the direction of flow as indicated by the arrow on the cell (see Diagram A).
• Always check Davey’s website, davey.com.au for the latest versions of Installation & Operation Instructions that support these products.
IMPORTANT INSTRUCTIONS FOR USE
Diagram A
CORRECT OPERATION WITH PUMP RUNNING
Direction of flow indicator
ü
Direction of flow indicator
Diagram B
INCORRECT OPERATION WITH PUMP RUNNING
û
3
Congratulations! You are now the proud owner of a new EcoMineral Water Sanitiser System. Please read all information in this manual carefully before installing or operating your EcoMineral Water Sanitiser System.
Contents
• Power Supply
• In-Line Electrolytic Cell
• 2 x Barrel Unions
• 2 x Union Cell Adaptors
• Mounting Kit
• Flow Switch
• Installation & Operating Instructions
• Blanking Cap (plug, o-ring and lock ring)
PACKING LIST ........................................................................................................................................................... 2
IMPORTANT INFORMATION ..................................................................................................................................... 3
INSTALLATION INSTRUCTIONS FOR ECOMINERAL ............................................................................................. 4
CONNECTING THE IN-LINE ELECTROLYTIC CELL TO THE POWER SUPPLY ....................................................5
CONNECTING THE IN-LINE ELECTROLYTIC CELL FLOW SWITCH
TO THE POWER SUPPLY ......................................................................................................................................... 6
PRE-START UP PROCEDURE .................................................................................................................................. 7
OPERATION OF YOUR ECOMINERAL SYSTEM ..................................................................................................... 8
CONTROL PANEL LAYOUT .......................................................................................................................................9
ECOMINERAL SPECIAL FEATURES ...................................................................................................................... 10
AUTOMATIC TIME CLOCK OPERATION ................................................................................................................ 11
MAINTENANCE OF POWER SUPPLY .................................................................................................................... 13
MAINTENANCE OF THE IN-LINE ELECTROLYTIC CELL ...................................................................................... 13
DAY TO DAY OPERATION ....................................................................................................................................... 15
CHLORINE PRODUCTION ...................................................................................................................................... 16
GENERAL INFORMATION ....................................................................................................................................... 17
TROUBLE SHOOTING ............................................................................................................................................ 18
MOUNTING TEMPLATE .......................................................................................................................................... 19
Packing List
Included with your EcoMineral System are the following items, please check the contents of the box carefully prior to attempting to install the system:
EcoMineral
®
Note: The Sanitiser is not intended for use by young children or inrm
persons without supervision. Please ensure that young children are supervised to ensure that they do not play with the Sanitiser.
Power connections and wiring must be carried out by an authorised electrician.
4
IMPORTANT INFORMATION
ABOUT YOUR SANITISER
FACTORS THAT WILL IMPROVE THE PERFORMANCE
& LIFE OF YOUR ECOMINERAL WATER SANITISER
PLEASE READ THIS BEFORE OPERATING YOUR SANITISER
POOL BUILDERS: Please cover this information with your customer during the
new pool “Handover Session”
Sanitisers are a valuable piece of pool sanitising equipment and must be cared for to get the best performance and life span from it.
There are THREE main factors that will damage your Sanitiser and reduce the life of the product. Please monitor the following factors in accordance with your installation & operating instructions.
1. MAINTAIN RECOMMENDED TOTAL DISSOLVED SOLIDS (TDS) LEVELS
RECOMMENDED OPERATING RANGE: 4,000 - 6,000ppm
• Run Sanitiser at the TDS levels stated within this document and on the product to ensure optimum sanitiser output and cell life.
• Operating this device at low TDS levels will damage the cell and reduce its life.
• The control panel displays a red LED indicator warning when the TDS levels are low.
• If no action is taken to rectify the TDS levels, damage to the cell may result which will not be covered under warranty.
2. MONITOR & MAINTAIN YOUR SANITISER IN-LINE CELL
EcoMineral has a “Reverse Polarity” In-Line cell.
• To keep your EcoMineral Sanitiser in the best possible condition, regular monitoring of the electrolytic cell is recommended. The ‘Cell’ is the clear plastic housing containing the plates.
• During the sanitisation process a white powdery Calcium scale may naturally build up on the titanium plates in the cell. Monitor the cell to prevent excessive scale build up. Excessive scale
build up will cause damage to your cell, and dramatically reduce its efciency and lifespan.
• Reverse Polarity models have low maintenance cells that minimise scale build up.
• The control panel displays a red LED indicator warning when the cell requires cleaning.
• If Calcium scale builds up please clean the cell, following the cleaning instructions provided on page 14.
• NEVER: Use concentrated acid to clean your cell.
• NEVER: Leave cell in cleaning solution for extended periods of time
• NEVER: Use metal implements, scourers or brushes to clean your cell
3. BALANCED POOL WATER CHEMISTRY
• EcoMineral Salt and Activator TDS levels MUST be maintained at 4,000 - 6,000ppm for optimum performance and lifespan
• Calcium Hardness levels MUST be kept to ideal ranges of 200 - 275ppm (for Concrete and Tiled Pools) and 100 - 225ppm (for other surfaces) to prevent excessive scale build up and damage to equipment
• pH levels MUST be kept to ideal levels to prevent damage to equipment and pool surfaces and to obtain optimum sanitiser effectiveness.
• Total Alkalinity and Stabiliser levels must also be kept in an ideal range.
Note: Please refer to the POOL WATER CHEMISTRY chart on page 17 for more information.
5
INSTALLATION INSTRUCTIONS FOR ECOMINERAL
INSTALLING THE POWER SUPPLY
Select a convenient well-ventilated location within one metre of lter equipment and mount the Power Supply
vertically onto a post or wall 1.5 metres above ground level. Australian Standards requires that the Power Supply shall not be located within 3 meters of the pool water. Plug Power supply into a suitable weatherproof outlet and plug pump into the power outlet of the Power Supply Unit. The Unit must be kept away from acid and other chemical storage areas. Acid and chemical vapours will corrode the electronics inside the Unit. It must also be kept away from heat sources. Good ventilation is necessary for correct operation.
Return to pool lineSuction Line
PUMP FILTER
ACCESSORIES
IN-LINE CELL
FLOW SWITCH
POWER SUPPLY
240V
Two self-tapping screws and wall plugs have been provided for fast and simple installation.
Use a 6mm masonry drill bit when tting Power Supply to a brick or concrete wall. When mounting to a post drill pilot holes and t screws provided. Once screws are in position simply hang Sanitiser via bracket on
back of Unit.
IMPORTANT: This diagram is intended to conform with SPASA for the safe operation of salt sanitisers. Any deviation is at the installer’s risk and may void the manufacturer’s warranty.
NOTE: The cell must be tted to allow for easy
removal and cleaning, and positioned after all accessories such as heater or pool cleaner, but before it divides if there is more than one return to pool line.
6
CONNECTING THE IN-LINE ELECTROLYTIC CELL TO THE POWER SUPPLY
The EcoMineral System uses a reverse polarity In-Line Electrolytic Cell for low maintenance operation.
The EcoMineral Power Supply is tted with a exible lead terminated with push on brass connectors for the
EMX2400 model and push on brass connectors with a securing nut for the EMX3600 model.
These must be correctly tted to the connections on the Cell. Fit black connectors to the outer titanium rods.
Fit the white connector to the middle titanium rod as per illustration below.
EMX2400
EMX3600
NOTE: The EcoMineral Cell is supplied with a paddle type ow switch, which is to be installed on the Cell as shown in the diagram on page 4.
IMPORTANT: The ow switch must be mounted with the highlighted arrow on top of the switch pointing in the direction of ow.
Tighten the “push on cell connectors” on the EMX2400 by using a pair of pliers, once applied.
Tighten the nuts with a suitable spanner to secure the cell connectors to the titanium rods, on the EMX3600 once applied. Hold the back of the cell leads when tightening.