Davey Crystal Clear 39075, Crystal Clear 39175, Crystal Clear 39100, Crystal Clear 39150, Crystal Clear 39050 Installation & Operating Instructions Manual

...
Davey Crystal Clear
Cartridge Filters
Models: 39050, 39075,
39100, 39150, 39175 & 39225
Installation & Operating Instructions
INTRODUCTION
– 2 –
Your Davey Cartridge Filter
Congratulations on your purchase of a quality product from the Davey range of Pool and Spa Equipment. You are assured of many years of reliable and
efcient performance from your Davey Filter backed by Davey’s 5 year tank
guarantee.*
Davey Crystal Clear™ Cartridge Filters have been specically designed for the ltration of spa and swimming pool water. They should not be used for any other purpose without rst consulting your Davey Dealer or Davey
Customer Service Centre.
Davey Cartridge Filters provide economy, high performance and convenience in a well-designed pressure lter. The polyester element can
be removed quickly for rinse cleaning without water loss. Davey Cartridge
Filters feature large lter areas which ensure even water distribution, peak ltration performance and longer lter cycles.
The corrosion-resistant construction of Davey Cartridge Filters provides long-life and durability. Davey Cartridge Filters are capacity matched with Davey pool pumps forming a total pool ltration system that lasts and lasts. Davey Cartridge Filters are also very suitable for use with other pool pumps. Take care to match the pump and lter capacities to gain maximum performance and efciency.
The Sparkling Clear Water Difference
Cartridge ltration is an effective trouble-free proven method of ltration. Pool water enters the lter and passes through a polyester element
cartridge. Suspended particles are trapped and the water is returned to the
pool. As the build-up of dirt in the element increases, so the water pressure rises and the ow decreases. When the pressure reaches an unacceptable level, the element must be removed and cleaned. (Spray washing with a common garden hose is generally sufcient).
* Refer to guarantee statement for full details
Installation and Operating Instructions Location
The lter should be placed in its permanent location, preferably as close to the pool as practicable. Position the lter tank and pump on a level concrete slab or similar base. Allow sufcient space around the lter for routine
maintenance and provide for adequate ventilation and drainage.
Place the pump in position on the slab and locate the lter alongside with
the appropriate pump inlet connection oriented towards the pump. Refer to
the specication section for the minimum clearance measurements required
for each model.
– 3 –
Weather Protection
Davey Cartridge Filters are constructed of corrosion resistant materials. However, to ensure years of reliable performance, it is recommended that the ltration system is adequately protected from the weather.
Assembly
Assemble the pressure gauge to the lter lid using Teon tape on the male
thread. Do not over-tighten.
Pipe Connections
Piping should be independently supported and not impose heavy loads on
the lter or pump. Use 40mm or 50mm pipe for pump and pool return lines. 50mm should always be used if length of piping is over 15m.
If the pump and lter are located below pool water level, it is necessary to t isolating valves in the pipe between the pump and the pool, and in the return line from the lter to the pool.
1. Pump to the Filter
Davey Cartridge Filters are equipped with two inlet ports marked ‘INLET’.
Select the inlet port most suitable for the installation and plug the other
inlet port with the blanking cap provided. Using quick connect couplings,
connect the pool pump delivery piping to the selected inlet port. Tighten
by hand only. Ensure the oring on the tting is clean, lubricated with oring
lubricant and in the correct position.
2. Filter to Pool Return
Using quick connect couplings, connect the pool return piping to the lter tting marked ‘OUTLET’. Tighten the tting by hand only. Ensure the oring on the tting is clean, lubricated with oring lubricant and in the correct
position.
The lter base is provided with four mounting holes to enable it to be secured, if required.
Barrel unions need to be hand tightened on. No sealant, glues or silicones are required.