DATOptic S-tray User Manual

DATOptic Inc S-tray - Use for Sbox-P, Sbox-R, EZRAID, and ForensicDECK.
Caution:
- Make sure the Key is ON position, after the Tray installed
- If the HDD is not working, please check to make sure the mount holes correctly used
- DO NOT remove the Tray while in operation mode, this may damage the HDD and result of lost data
- After set-up, push the RESET button to default the setting of temperature detection 45C (113F) and fan RPM 1000RPM
Illustrations
Top cover Mobile Panel
Must use mounting hole Eject bar to secure HDD
**************************************************************************************** Features:
- All Aluminum structure design, best effective heat sink
- Pattern pending bottom fan design, suitable to high RPM HDD
- Easy insert, remove handle bar
- Support 3.0Gb SATA transfer rate
- Real time indication for FAN SPEED and HDD temperature
- Alarm off, when temperature and Fan speed out of range
- Temperature display in Celsius or Fahrenheit
- Attractive Blue light background LCD
INSTALLATIONS Hardware Installations:
All equipment must be OFF ( no powe r ) before any installation is performed
1. Turn Key lock to OFF Position
2. Secure HDD to the tray
NOTE: Use the ROUND holes a the anchor mounting SATA, otherwise HDD may not connect properly
3. Insert back to the Mobile shell.
4. Turn the Key lock to ON, to prevent accidental removal
5. Power on,
6. Push the reset button to the default setting
Note: Specifications subject to change without notice. Copyright © 1998 - 2006 DATOptic Inc. All Rights Reserved.
Function of LCD tray
1. Display temperature range from 30 C to 90 C
2. Display fan speed from 1000 to 9900RPM
3. Over temperature When temperature is higher than setting value, the digits on the LCD start flashing and buzzer will goes off. As long as the cause of the over temperature is correct (remove) buzzer will silent and LCD display will go back to normal. However the fault is not correct / fix the alarm will be silent within 30sec, but the digits on LCD will remain flashing until the cause is fixed.
4. Low RPM or fan failed When fan speed (RPM) is lower than setting value, the digits on the LCD start flashing and buzzer will goes off. As long as the cause of the over temperature is correct (remove) buzzer will silent and LCD display will go back to normal. However the fault is not correct / fix the alarm will be silent within 30sec, but the digits on LCD will remain flashing until the cause is fixed.
5. If the fan is disconnect, the LCD will disable
Adjustment LCD MODE and SET buttons are the programmable button for temperature and fan
speed setting Push MODE button for 2seconds, S_tray will enter setting mode, where SET
button is use to adjust the setting value. The setting will change as follow when MODE button is pressed
T1 -> F1 -> T2 -> F2, and its cycle will repeat Our S_tray can monitor TWO set of temperature and fan speed at he same time.
It one set is set, then the other set will display “- -“ . To save the new set of value
- Press the NODE button for 2 seconds or let it idle for one minute Note:
The temperature increment is 5 C The fan speed increment is 1000temperature increment is 5 C