Dateq SD-1 User Manual

SD - 1
UUSER MANUALSER MANUAL
EN
Safety instruction DATEQ Silence detector user manual
1
Safety instructions
5 The equipment may never be used in the immediate vicinity of water; make sure that
water and damp cannot get into the equipment.
6 The equipment may only be installed or fitted in accordance with the manufacturers
recommendations.
7 The equipment must be installed or fitted such that good ventilation is not obstructed
in any way.
8 The equipment may never be installed in the immediate vicinity of sources of heat,
such as parts of heating units, boilers, and other equipment which generates heat (including amplifiers).
9 Connect the equipment to a power supply of the correct voltage, using only the
cables recommended by the manufacturer, as specified in the operating instructions and/or shown on the connection side of the equipment.
10 The equipment may only be connected to a legally approved earthed mains power
supply.
11 The power cable or power cord must be positioned such that it cannot be walked on
in normal use, and objects which might damage the cable or cord cannot be placed on it or against it. Special attention must be paid to the point at which the cable is attached to the equipment and where the cable is connected to the power supply.
12 Ensure that foreign objects and liquids cannot get into the equipment. 13 The equipment must be cleaned using the method recommended by the
manufacturer.
14 If the equipment is not being used for a prolonged period, the power cable or power
cord should be disconnected from the power supply.
15 In all cases where there is a risk, following an incident, that the equipment could be
unsafe, such as:
if the power cable or power cord has been damaged
if foreign objects or liquids (including water) have entered the equipment
if the equipment has suffered a fall or the casing has been damaged
if a change in the performance of the equipment is noticed
it must be checked by appropriately qualified technical staff.
16 The user may not carry out any work on the equipment other than that specified in the
operating instructions.
2
DATEQ Silence detector user manual General
EN
SD1SD1 SiSilence Detectorlence Detector
General
The DATEQ SD-1 has been designed for activating backup-units if the regular audio signal fails. The SD-1 is equipped with opto-coupler outputs to start and stop the connected backup-devices and
an alarm-output to which a telephone-dialler can be connected. Parallel to the alarm-output the SD-1 comes equipped with a solid-state relay. This makes it possible to switch on and off the mains supply of the backup-devices.
With trimmers at the back of the silence detector the start and stop delay and the no-audio detection level can be adjusted. The backup input has a gain-trimmer. With the internal dip-switches various switching patterns can be selected to start and stop the backup-units. Furthermore it is possible to enable an internally trimmable pilot-tone detection and to select a different timing mode. By pressing the bypass switch at the front the main-input will be selected.
Product support
If you have any questions about the SD1, or about other DATEQ products please contact:
Dateq Audio Technologies B.V.
De Paal 37 1351 JG Almere The Netherlands
Telefoon: +31 36 54 72 222 Fax: +31 36 53 17 776 E-mail: info@dateq.nl Internet: www.dateq.nl
Power
Power
Audio present
Pilot present
Backup active
Backup failed
Alarm
Output level
SD1
L
R
dB
62+18 5 23-10122030
Silence Detector
Bypass
EN
Connecting DATEQ Silence detector user manual
3
Connecting
The tables below show the various connections.
Ground Lift
Switch to make the outputs floating with respect to the earth. When the switch is pushed downwards the outputs ground will be linked to the frame.
Input Level
Gain-preset for the backup-input. Range +/-12dB.
Backup input (2x cinch)
Main input (2x XLR-F)
Main output (2x XLR-M)
Function of the trimmers
Output Optocouplers connector
Maximum rating: 25V / 50mA
Alarm Relay
Solid state relay output. The backup-devices main supply can be switched on and off with this output. Maximum rating: 230V/ 2A.
Backup
L
R
Main input Main output
LLRR
Trigger
InputGround
Start End
level
levelLift
delay delay
connectorrelay
minmin
maxmax
sec
sec
60 60
3030
0 0
1515
45 45
Output
Alarm
Output connector
Pen Function
1
Stop -
2
Start -
3
Alarm 2 -
4 Alarm active ­5 6 Stop + 7 Start + 8 Alarm 2 + 9 Alarm active +
Mains
230V/ 50Hz/ 15W
2000
WARNING: Dangerous voltages inside. To be opened only by authorised people
230Vac/ 2A
Silence detector
SD1
Pin Function Type
Tip Audio + In Shield Audio GND GND
Pin Function Type
1 Audio GND GND 2 Audio + In 3 Audio - In
Pin Function Type
1 Audio GND GND 2 Audio + Out 3 Audio - Out
Trigger level
no-audio detection sensitivity -25 .. -70 dBu
Start Delay
Time between no-audio detection and backup-start
0 .. 60 sec.
Stop Delay
Time between audio detection and backup-stop
0 .. 60 sec.
Pin Function Type
1 Stop - Out 2 Start - Out 3 Backup fail - Out 4 Alarm - Out 5 NC 6 Stop + Out 7 Start + Out 8 Backup fail + Out 9 Alarm + Out
4
DATEQ Silence detector user manual Settings
EN
Settings
To adjust the internal jumper-settings the SD-1 has to be opened. First loosen the bolds at the front and at the back of the SD-1 one turn. Next unscrew three the screws of the top-lid completely. Now the lid can be folded of the SD-1.
With the internal dip-switches some extra settings can be made. In the drawing below the dip­switches are shown.
Pilot alarm
When this function is enabled the backup-device will be activated when the pilot-tone (19kHz) is not active or when the audio at the main-input stops. When this switch is disabled (default) the backup device will only start when no audio is present at the main input. The pilot-tone detection level can be adjusted with trimmer RT1.
Inverted outputs
By activating this switch the alarm outputs will be inverted.
Pulsed outputs
When this switch is active the start and stop output will generate a 100mSec pulse to start and stop the backup-device. This function can be combined with the ‘inverted outputs’ function.
Timing mode
With this switch the detection-mode can be adjusted. When the switch is in the ON-position the start and stop timers will reset as soon as an audio-signal is detected. When the switch is in the OFF-position the timers will count up and down according to the presence of the detected signal.
The advantage of disabling this function: The backup device will not stop when there are only short sporadic signals or noises on the line.
The advantage of enabling this function: When in an interview a natural silence occurs the timers will immediately reset when a person starts to speak.
RP1
RP2
RP3RP4
XT1
R27
ON
4321
U12
D11
D10
D3
D2
D1
P6
U9
C35
C34
C33
C37
C36
C24
U6
R26
R45
R25
R24
R23
R22
Vcc
Switch number Function
1 Pilot alarm 2 Inverted outputs 3 Pulsed outputs 4 Timing mode
EN
Technical specification DATEQ Silence detector user manual
5
Technical specification
INPUTS
MAIN INPUT................................................... Electronically balanced
Signal level............................................+6dB @ 600ohm
Impedance ............................................. 12 kohm nominal
Noise ..................................................... < -86 dB (IHF-A)
Crosstalk................................................ > 90 dB @ 1 kHz
THD+N................................................... 0.002%
BACKUP INPUT ............................................. Cinch
Signal level............................................0 dB @ 600ohm adjustable (+/-12dB)
Impedance ............................................. 6 kohm nominal
Noise ..................................................... < -86 dB (IHF-A)
Crosstalk................................................ > 85 dB @ 1 kHz
THD+N................................................... 0.02%
Detection threshold......................................... -25...-70dBu
OUTPUTS
MAIN OUTPUT............................................... +6 dB balanced/ 600ohm
OUTPUT CONNECTOR.................................DB9-F
Max. voltage.......................................... 25V
Max. current........................................... 50mA
SOLID STATE RELAY ....................................
Max. voltage.......................................... 230V
Max. current........................................... 2A
GENERAL
MAINS SUPPLY
Voltage range........................................220...240 VAC / 50 Hz
Power consumption...............................15 W
DIMENSIONS AND WEIGTH
Front......................................................483 x 44 mm (B x H) = 19”, 1HE
Depth..................................................... 205 mm without connectors
Weigth...................................................1.6 kg Nett.