NEW
®
INNOVATION and EX C ELL E N C
®
DTL Series
DTL4A Model
Digitally Programmable, 10A/150V
100 Watt, Electronic Loads
Features
■
12-bit, optically isolated (500Vdc),
CMOS/TTL-compatible serial input
■
0-10 Amp output in 2.44mA increments
■
10MΩ minimum output impedance
■
Output voltage to 150 Volts
■
Output power to 100 Watts
■
±3mA offset error; ±0.1% gain error
■
100µsec full-scale step response
■
Update rates to 20kHz
■
Operate in parallel for higher power
■
Miniature, 2" x 2" metal package
Applications
■
Static/dynamic power-supply burn-in
■
Power-supply test and characterization
■
Battery capacity testing
■
Current-source testing
■
Capacitor discharge testing
■
Real-time load simulation
DATEL’s new DTL4A is an optically isolated, digitally programmable, serial-input,
electronic load. It is essentially a digitally controlled current source that can sink
currents from 0 to 10 Amps, at loading voltages from 2.5 to 150 Volts, up to a maximum
power of 100 Watts. The DTL4A is packaged in a thermally effi cient, 2" x 2" x 0.5"
metal package that incorporates an aluminum baseplate with through-hole spacers
for easy pcb mounting and/or external heat-sink attachment.
The DTL4A accepts a serialized, 12-bit, CMOS/TTL-compatible, digital input word
easily generated by any standard digital I/O card. The DTL4A buffers and then
optically isolates (500Vdc) the digital input data before storing it in a register and
presenting it to an on-board, 12-bit, digital-to-analog (D/A) converter. The D/A output
drives a near-ideal (10MΩ minimum output impedance), voltage-controlled current
source. One LSB (least signifi cant bit) of the D/A converter corresponds to a 2.4mA
increment (0.024% of 10A) in load current.
The DTL4A features a max. ±3mA offset error and a max. ±0.1% gain error. It
has an impressive full-scale step response time of 100µsec and can be operated
dynamically at update rates up to 20kHz. Powered by a single +5V supply, the DTL4A
draws a mere 150mA (maximum).
While operating in the constant-current mode up to 10 Amps (100W max. power),
the output compliance voltage of the DTL4A is 2.5 to 150 Volts. Should the output/load
voltage drop below the 2.5V minimum required for proper biasing, an internal monitoring
circuit activates the DTL4A's output Fault line. See DATEL’s DTL2A-LC for compliance
voltages as low as 0.6V.
DTL4A’s and other electronic loads, controller boards, and software from DATEL
are outstanding building-block components for power-supply burn-in and test systems.
They are an extremely reliable, cost-effective solution that enables you to quickly
confi gure impressively accurate systems.
INPUT
BUFFERS
CONTROL STROBE (CS)
CLOCK (CLK)
SERIAL DATA INPUT (SDI)
LATCH DATA (LD)
+5V SUPPLY
GROUND
DATEL, Inc., Mansfi eld, MA 02048 (USA) · Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 · Email: sales@datel.com · Internet: www.datel.com
ISOLATED
DC/DC
CONVERTER
OPTO
ISOLATORS
DATA
LATCH
Figure 1. Simplifi ed Schematic
12-BIT
D/A
AMPLIFIER
AND
CURRENT
SENSOR
UNDERVOLTAGE
DETECTION
+LOAD
+LOAD
–LOAD
–LOAD
POWER DEVICE
UNDER TEST
FAULT
DTL Series
100 WATT, SERIAL-INPUT ELECTRONIC LOADS
Performance Specifi cations and Ordering Guide
➀
Input Output
Compliance
Resolution Logic Current Resolution Voltage Power Package
Model (Bits) Compatibility (Amps) (mA)
➁ (Volts) ➂ (Watts) (Case, Pinout)
DTL4A 12 CMOS/TTL ➃ 0-10 2.44 2.5-150 0-100 C24, P31
➀ Typical at TA = +25°C with nominal +5V supply voltage unless noted.
➁ The smallest increment/decrement in output current is defi ned by one LSB (least signifi cant bit) of the 12-bit
digital input word. One LSB is equal to full scale (FS) divided by 4096 which corresponds to 0.0244% of 10A or 2.44mA.
➂ For proper operation, the unit's output/load voltage must remain within this range. Voltages greater than the listed
maximum can damage the device. Voltages less than the minimum provide insuffi cient bias for the output stage
and will result in unpredictable or no operation. See Output Compliance Voltage and the Fault Line for details.
➃ See Performance/Functional Specifi cations for details.
PART NUMBER STRUCTURE
DTL 4
DATEL
Electronic Load
A
A-Series
High Reliability
MECHANICAL SPECIFICATIONS
2.00
(50.80)
0.50
(12.70)
Case C24
ALUMINUM BASEPLATE
METAL CASE
Voltage Range:
4 = 2.5 to 150V
0.20 MIN
(5.08)
0.040 ±0.002 DIA.
(1.016 ±0.051)
1.800
(45.72)
1.640
(41.66)
0.060 ±0.002 DIA.
(1.524 ±0.051)
0.10
(2.54)
0.08
(2.03)
TEMPERATURE DERATIN
10
11
BOTTOM VIEW
8
9
2.00
1.640
(50.80)
(41.66)
0.22
(5.59)
100
90
80
70
60
50
40
Output Power/Load (Watts)
30
20
10
010 203040506070809010
Baseplate Temperature (°C)
The horizontal axis of the above chart references the temperature of the DTL4A’s alumi-
num baseplate. The device can continually dissipate up to 100 Watts if the baseplate
7
6
1.20
(30.48)
6 EQ. SP. @
0.200 (5.08)
0.40
(10.16)
5
4
3
2
1
#4-40 CLEAR THRU
(TYP. 4 PL)
I/O Connections
Pin Function P31 Pin Function P31
1 Fault 7 Control Strobe (CS)
2 Ground 8 –Load
3 +5 Volt Supply 9 –Load
4 Latch Data (LD) 10 +Load
5 Serial Data In (SDI) 11 +Load
6 Clock (CLK)
is maintained at or below +50°C. At +25°C ambient temperature, with no heat sink or
supplemental air fl ow, the DTL4A can reliably dissipate a continuous 10 Watts.
Contact DATEL for Heat Sink information.
2