DATEL DMS-40PC-3-YS, DMS-40PC-3-RS-BCD, DMS-40PC-3-RS, DMS-40PC-3-RL-BCD, DMS-40PC-3-RL Datasheet

...
DATEL, Inc., Mansfield, MA 02048 (USA) • Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 Email: sales@datel.com • Internet: www.datel.com
Features
••
••
Precision, autozeroing, factor y­calibrated A/D converter
••
••
Scientific-grade accuracy, ±2 counts
••
••
Miniature size:
••
••
Large (0.52"/13.2mm) LED display
••
••
Choice of red, green or yellow colors
••
••
High-intensity or low-power red LED's optional
••
••
Single +5V supply (175mW for low­power models)
••
••
Epoxy-encapsulated, 12-pin DIP with built-in color filter and bezel
••
••
3 differential input voltage ranges
••
••
DISPLAY HOLD and TEST functions
••
••
Optional BCD data outputs for CPU interface
••
••
0 to +50°C temperature range
4½ Digit, LED Displa y
Precision, Miniature
Digital Panel Voltmeters
DMS-40PC Series, 4½ Digit, LED Display, Miniature DPM's are fully self-contained, component-like, plug-in meters that provide scientific-grade accuracy (typically ±2 counts or ±0.005% of full scale) and outstanding reliability at a very affordable price.
Within its miniature (2.17" x 0.92" x 0.56"), epoxy-encapsulated package, each meter contains a precision reference circuit; a high-resolution, autozeroing, factory­calibrated A/D conve rter; and a large (0.52"/13.2mm), easy-to-read, LED display. LED's are available in red, yellow and green colors. Red LED's are also offered in high-intensity or low-power versions.
The versatile design of the DMS-40PC Series assures trouble-free installation and long-term operation. Differential input voltage ranges include ±2V, ±20V and ±200V. Input impedance is a minimum 800k. Non-inverting inputs are overvoltage protected to ±250V, and CMRR is typically 86dB (dc to 60Hz).
The DMS-40PC's epoxy-encapsulated package has an integr al bezel and color filter. The moisture and vibration-proof package is extremely rugged and well suited for harsh environments and extended temperatures. Devices are fully specified for 0 to +50°C operation.
All models operate from a single +5V supply and typically consume 500mW. Low­power models, whose display is just as bright as standard models, typically consume 175mW. DISPLAY TEST and HOLD functions are standard on each meter, and a complete set of BCD outputs are optional for sending data to CPU's or remote displays.
Figure 1. DMS-40PC Series Simplified Schematic
DMS-40PC Series
Actual Size
(+) INPUT HI
(–) INPUT LO
ANALOG COMMON
DP4
REFERENCE IN/OUT
+5V SUPPLY
R1
DP 1
DP 2
DP 3
6
5
4
9
11
12
10
8
7
1
3
DC/DC
CONVERTER
2
5V RETURN
+5V
–5V
+5V
2.5V REF.
R2
DATA
V+
V–
A/D
CONVERTER
0 Vdc
0.01µF
DISPLAY HOLD
DISPLAY TEST
R2 is not used on ±2V (-1) models. R2 = 101k on ±20V (-2) models and 9.2k on ±200V (-3) models.
909k
1
1
®®
www.datel.com
2
DMS-40PC
4½ DIGIT, LED DISPLAY DIGITAL PANEL VOLTMETERS
Performance/Functional Specifications
Typical at TA = +25°C and supply voltage = +5V using the single-ended input circuit, unless otherwise noted.
Applies for transient or continuous overvoltages applied to (+) INPUT HI (pin 11) with (–) INPUT LO (pin 12) properly connected. Pin 12 is not overvoltage protected (see Figure 1). Voltages applied to pin 12 should not exceed the supply voltage.
See Technical Notes.
BCD outputs are optional and must be specified in the part number. See Ordering Information.
Includes high-intensity and BCD-output models.
Accessories:
DMS-30-CP Panel cutout punch DMS-BZL1 DMS-40 bezel assembly DMS-BZL2 DMS-40 bezel assembly with sealing gasket DMS-EB Application/evaluation board with standard
MOLEX connector, decimal point solder pads and attenuation resistor pads.
BCD Output Models:
BCD outputs are only available on standard red meters.
DMS-40PC-1-RS-BCD for ±2V input range DMS-40PC-2-RS-BCD for ±20V input range DMS-40PC-3-RS-BCD for ±200V input range DMS-40PC-1-RL-BCD for ±2V input range DMS-40PC-2-RL-BCD for ±20V input range DMS-40PC-3-RL-BCD for ±200V input range
DMS- 40PC - 1 - RS
T echnical Notes
1. ANALOG COMMON (Pin 10): This pin is an internal, low-noise
ground for the DMS-40PC. It is internally connected to pin 3 (5V RETURN). Do not connect pin 10 to either pin 3 or your system ground as this will create a ground loop and possibly result in erroneous readings.
2. REFERENCE INPUT/OUTPUT (Pin 7): This pin accesses the meter's internal reference and is used during the factory calibration procedure. Pin 7 should be left open in most common applications. It can be used in certain "ratiometric" applications in which it is desirable for the meter’s reference to track an external reference. See Ap Note 3 in the DATEL Panel Meter Catalog for more details.
3. DISPLAY TEST (Pin 2): Connecting pin 2 to ground (pin 3, 5V RETURN) will activate all LED segments, and the display will read "–18888" regardless of the actual applied input. To reduce self­heating, the display should not be left in the "test" mode for
more than 10 seconds. This pin should be left open if unused.
4. DISPLAY HOLD (Pin 9): For normal operation, this pin should be
left open. To hold the meters last reading and display it continu­ously, tie pin 9 to ground (pin 3, 5V RETURN).
5. Decimal Point Placement: The location of the decimal point is user-selectable, and the decimal point control pins (DP1-DP4) are active low functions. Select the appropriate decimal point by tying pin 4, 5, 6 or 8 to pin 3 (5V RETURN). Unused decimal point location pins should be left open.
Ordering Information
LED Color:
GS = Standard Green RH = High-Intensity Red RL = Low-Power Red RS = Standard Red YS = Standard Yellow
Input Range:
1 = ±2V 2 = ±20V 3 = ±200V
A panel-mount retaining clip is supplied with each model.
Analog Inputs Min. Typ. Max. Units Full Scale Input Range:
DMS-40PC-1 -- ±2 -- Volts DMS-40PC-2 -- ±20 -- Volts DMS-40PC-3 -- ±200 -- Volts
Input Impedance:
DMS-40PC-1 100 1000 -- M
DMS-40PC-2, -3 0.8 1 -- M
Overvoltage Protection
-- -- ±250 Volts
Common Mode Voltage Range -- -- ±2 Volts CMRR (dc to 60Hz) -- 8 6 -- dB Control Inputs Decimal Point Placement (Pins 4-6, 8) Tie to pin 3 to activate Display T est (Pin 2) Tie to pin 3 to activate all segments Display Hold (Pin 9) Tie to pin 3 to hold last reading BCD Outputs
Logic levels (1 LSTTL load max.):
Logic "1" +2.4 -- -- Volts Logic "0" -- +0.4 +0.8 Volts
Performance
Sampling Rate 2.5 samples per second Accuracy (15 minute warm-up):
DMS-40PC-1 (VIN = +1.9V) -- ±2 ±3 Counts DMS-40PC-2 (VIN = +19V) -- ±3 ±4 Counts DMS-40PC-3 (VIN = +190V) -- ±3 ±4 Counts
Zero Reading (VIN = 0 Volts) "–0001" "0000" "0001" Temperature Drift (0 to +50°C):
DMS-40PC-1 -- ±0.4 ±1 Cnts/°C DMS-40PC-2, -3 -- ±0.4 ±1.5 Cnts/°C
Power Supply Requirements Supply Voltage +4.75 +5.00 +5.25 Volts
Supply Current:
Standard Models
-- +100 +140 mA
Low-Power Models -- +3 5 +50 mA
Display Display Type and Size 4½ Digit LED, 0.52"/13.2mm high Polarity Indication Autopolarity ("–" for negative VIN)
Overrange Indication "–0000" (flashing) for negative VIN
"0000" (flashing) for positive VIN
Physical/Environmental Operating Temperature 0--+50°C
Storage Temperature 20 -- +75 °C Humidity (Non-condensing) 0 -- 9 5 % Case Material Polycarbonate Weight 0.75 ounces (21 grams)
Order on-line at www.datel.com