Datasheet ZA675-D6 Specification

Product Specifications Model No.:GPZA675
1
Document Number: ZA0004 Revision:0 Page
1.
1. APPLICABILITY
APPLICABILITY
1.1.
APPLICABILITYAPPLICABILITY
This specification is applicable to GP Zinc Air GPZA675.
2.
2. GENERAL
GENERAL
2.2.
GENERALGENERAL
2.1 Type designation : PR44(IEC/JIS) / 7003ZD(ANSI)
2.2 Nominal voltage : 1.4V
2.3 Shape and dimension
2.4 Typical Capacity
2.5 Typical weight : 1.8g
2.6 Warranty period : 12 months
2.7 Date code : Unless otherwise specified, every battery will carry an expiry
: Refer to Drawing 1.
: 620mAh (continuous discharge under 620Ω to 0.9V at 20°C
date code for 36 months. (e.g. a battery manufactured on January 1999 will carry an expiry code of 01-02.)
of
5
3.
3. APPEARANCE
APPEARANCE
3. 3.
APPEARANCEAPPEARANCE
There shall be no dirt, scratch or deformation detrimental to practical service in appearance.
4.
4. CELL VOLTAGE
CELL VOLTAGE
4.4.
CELL VOLTAGECELL VOLTAGE
4.1 Test method l Method of sampling : MIL-STD-105E level II single sampling normal inspection.
Voltmeter : Digital Voltmeter (DVM) with the precision of 1mV (internal resistance
Test temperature
4.2 Off Load Voltage
At shipping
At shipping 12 months after manufactured
At shippingAt shipping
1.36V to 1.46V 1.36V to 1.46V
not less than 1 Megohm)
: 20±2°C
12 months after manufactured
12 months after manufactured12 months after manufactured
Product Specifications Model No.:GPZA675
2
Document Number: ZA0004 Revision:0 Page
4.3 On Load Voltage
Initial
Initial 12 months after manufactured
InitialInitial
Above 1.3V Above 1.3V
Load resistance : 620
5.
5. SERVIC
SERVICE OUTPUT
5.5.
SERVICSERVIC
5.1 Test method (1) The resistance of external discharge circuit shall be as specified plus or minus 0.5%. (2) The duration of discharge time periods shall be as specified plus or minus 1%. (3) Storage shall be at 20±2°C, 65±20%RH and discharge tests shall be at 20±2°C, 65±20%RH.
E OUTPUT
E OUTPUT E OUTPUT
0.5% (measure time : 0.8 seconds)
±
12 months after manufactured
12 months after manufactured12 months after manufactured
of
5
5.2 Service Life
12 months
Initial
Test Mode
Service
life at
20±2°C
M: minute H: hour EPV: end point voltage
*The initial discharge test shall commence within 30 days of manufacture. During this period, the cells shall be stored under room temperature conditions. (20±2°C and 65±20% relative humidity)
6.
6. ELECTROLYTE LEAKAGE
ELECTROLYTE LEAKAGE
6.6.
ELECTROLYTE LEAKAGEELECTROLYTE LEAKAGE
6.1 Leakage on arrival at warehouse.
Leakage shall be checked with naked eye. No leakage shall be observed with the naked eye; and no bulging
exceeding the maximum dimensions shall result.
6.2 Leakage at room temperature
Test Mode Application
Test ModeTest Mode
620Ωcontinuous (EPV=0.9V)
Application Initial
ApplicationApplication
Reference test 247H 225H 153H
Initial
InitialInitial
(Nominal)
(Nominal)
(Nominal)(Nominal)
Initial
InitialInitial
(Minimum)
(Minimum)
(Minimum)(Minimum)
12 months storage at
12 months 12 months
storage at
storage at storage at
20
20
CCCC
°°°°
2020
(Nominal)
(Nominal)
(Nominal)(Nominal)
After storing for 12 months at 20 ±15°C, 65±20%RH, no leakage shall be observed with the naked eye; and no
bulging exceeding the maximum dimensions shall result.
Product Specifications Model No.:GPZA675
3
Document Number: ZA0004 Revision:0 Page
6.3 Leakage at high temperature
Within thirty days of manufacture, the cell shall be stored for 30 days at 45±2°C and below 70% relative
humidity, no leakage shall be observed with the naked eye; and no bulging exceeding the maximum dimensions shall result.
6.4 Leakage of over discharge
After loading with 620Ω continuously down to 0.35V at 20±2°C, 65±20%RH, no leakage shall be observed with
the naked eye; and no bulging exceeding the maximum dimensions shall result.
7.
7. QUALITY ASSURANCE
QUALITY ASSURANCE
7.7.
QUALITY ASSURANCEQUALITY ASSURANCE
DESCRIPTION
DESCRIPTION AQL
DESCRIPTIONDESCRIPTION
Battery dimensions 0.65%
Appearance 1.0% Off load voltage 0.65% On load voltage 1.0%
Service output Note 1
Leakage 6.1
6.2
6.3
6.4
Note 1 : Acceptance / rejection in accordance with IEC publication (1993) 86-1, Sub-cl ause 8.8. Note 2: Leakage on arrival at warehouse is within two months after shipping. Note 3: Sample size : n=20
Judgement : Ac=1 Re=2
Note 4: Sample size :n=20 Judgement :Ac=0, Re=1
AQL
AQLAQL
0.65% (Note 2) Note 3 Note 4 Note 4
of
5
8.
8. PACKAGING
PACKAGING
8.8.
PACKAGINGPACKAGING
Packaging shall be a form agreed by both parties.
Product Specifications Model No.:GPZA675
4
Document Number: ZA0004 Revision:0 Page
Precaution & Handling
Precaution & Handling
Precaution & HandlingPrecaution & Handling
1) Do not disassemble or short-circuit batteries.
2) Do not recharge batteries.
3) Do not dispose of batteries in fire.
4) Do not allow metal objects to contact the battery terminals.
5) Do not mix with used or other battery type (such as alkaline with carbon zinc).
6) Do not solder the batteries directly. If soldering or welding connection to the battery is required, consult our engineer for proper methods.
7) Do not over-dis charge batteries. Force discharging batteries by external power source in a series may cause explosion.
8) To install or remove batteries, follow the equipment manufacturer’s instructions.
of
5
9) Keep battery away from small children. If swallowed, consult a physician at once.
10) Remove batteries from device when it is not is us e.
Storage
Storage
StorageStorage
1) Store in a cool, dry place before use.
2) Do not keep batteries at temperature of 45°C or above.
3) Do not keep batteries at relative humidity of 75% or above.
Product Specifications Model No.:GPZA675
5
Document Number: ZA0004 Revision:0 Page
Drawing 1
of
5
Loading...