This specification is applicable to GP Zinc Air GPZA312.
2. GENERAL
2.1 Type designation : PR41(IEC/JIS) / 7002ZD(ANSI)
2.2 Nominal voltage : 1.4V
2.3 Shape and
dimension
2.4 Typical Capacity
2.5 Typical weight : 0.6g
2.6 Warranty period : 12 months
2.7 Date code : Unless otherwise specified, every battery will carry an expiry
: Refer to Drawing 1.
: 125mAh (continuous discharge under 1300Ω to 0.9V at 20°C
date code for 36 months. (e.g. a battery manufactured on
January 1999 will carry an expiry code of 01-02.)
3. APPEARANCE
There shall be no dirt, scratch or deformation detrimental to practical service in appearance.
4. CELL VOLTAGE
4.1 Test method l
Method of sampling : MIL-STD-105E level II single sampling normal inspection.
Voltmeter : Digital Voltmeter (DVM) with the precision of 1mV (internal resistance
Test temperature
4.2 Off Load Voltage
At shipping 12 months after manufactured
1.35V to 1.45V 1.35V to 1.45V
not less than 1 Megohm)
: 20±2°C
Product Specifications Model No.:GPZA312
2
Document Number: ZA0003 Revision:0 Page
4.3 On Load Voltage
Initial 12 months after manufactured
Above 1.3V Above 1.3V
Load resistance : 1.3k
0.5% (measure time : 0.8 seconds)
Ω ±
of
5
5. SERVICE OUTPUT
5.1 Test method
(1) The resistance of external discharge circuit shall be as specified plus or minus 0.5%.
(2) The duration of discharge time periods shall be as specified plus or minus 1%.
(3) Storage shall be at 20±2°C, 65±20%RH and discharge tests shall be at 20±2°C, 65±20%RH.
5.2 Service Life
Test Mode Application Initial
(Nominal)
Service
life at
20±2°C
M: minute H: hour EPV: end point voltage
*The initial discharge test shall commence within 30 days of manufacture. During this period, the cells shall be stored under
room temperature conditions.
(20±2°C and 65±20% relative humidity)
1.3kΩcontinuous
(EPV=0.9V)
Reference test 110H 90H 88H
Initial
(Minimum)
12 months storage at
20
C
°°°°
(Nominal)
6. ELECTROLYTE LEAKAGE
6.1 Leak age on arrival at warehouse.
Leakage shall be checked with naked eye. No leakage shall be observed with the naked eye; and no bulging
exceeding the maximum dimensions shall result.
6.2 Leakage at room temperature
After storing for 12 months at 20 ±15°C, 65±20%RH, no leakage shall be observed with the naked eye; and no
bulging exceeding the maximum dimensions shall result.
Product Specifications Model No.:GPZA312
3
Document Number: ZA0003 Revision:0 Page
6.3 Leakage at high temperature
Within thirty days of manufacture, the cell shall be stored for 30 days at 45±2°C and below 70% relative
humidity, no leakage shall be observed with the naked eye; and no bulging exceeding the maximum
dimensions shall result.
6.4 Leakage of over discharge
After loading with 1.3kΩ continuously down to 0.35V at 20±2°C, 65±20%RH, no leakage shall be observed
with the naked eye; and no bulging exceeding the maximum dimensions shall result.
of
5
7. QUALITY ASSURANCE
DESCRIPTION AQL
Battery dimensions 0.65%
Appearance 1.0%
Off load voltage 0.65%
On load voltage 1.0%
Service output Note 1
Leakage 6.1
6.2
6.3
6.4
Note 1 : Acceptance / rejection in accordance with IEC publication (1993) 86-1, Sub-cl ause 8.8.
Note 2: Leakage on arrival at warehouse is within two months after shipping.
Note 3: Sample size : n=20
Judgement : Ac=1 Re=2
Note 4: Sample size :n=20
Judgement :Ac=0, Re=1
0.65% (Note 2)
Note 3
Note 4
Note 4
8. PACKAGING
Packaging shall be a form agreed by both parties.
Product Specifications Model No.:GPZA312
4
Document Number: ZA0003 Revision:0 Page
of
5
Precaution & Handling
1) Do not disassemble or short-circuit batteries.
2) Do not recharge batteries.
3) Do not dispose of batteries in fire.
4) Do not allow metal objects to contact the battery terminals.
5) Do not mix with used or other battery type (such as alkaline with carbon zinc).
6) Do not solder the batteries directly. If soldering or welding connection to the battery is required, consult our
engineer for proper methods.
7) Do not over-dis charge batteries. Force discharging batteries by external power source in a series may cause
explosion.
8) To install or remove batteries, follow the equipment manufacturer’s instructions.
9) Keep battery away from small children. If swallowed, consult a physician at once.
10) Remove batteries from device when it is not is us e.
Storage
1) Store in a cool, dry place before use.
2) Do not keep batteries at temperature of 45°C or above.
3) Do not keep batteries at relative humidity of 75% or above.
Product Specifications Model No.:GPZA312
5
Document Number: ZA0003 Revision:0 Page
Drawing 1
of
5