Datasheet XE3301I, XE3301G, XE3301F, XE3301B, XE3301 Datasheet (XECOM)

Page 1
XECOM (1) XE3301
Multi-National 33,600 BPS Modem Module
XE3301
11-05-96
xecom
Description
Xecom's XE3301 is a complete 33,600 bps modem in a single component. It is available for use in many countries throughout the world. Xecom offers versions for North America and Japan, Germany, France, the United Kingdom and other countries of the European Community.
The XE3301 is a complete modem including the DAA. XE3301 users do not need to add RAM, ROM, Crystals, transformers, or switches to complete the modem design. The user only needs to provide the TTL level, serial interface and the telephone jack.
The XE3301 is a full-featured modem. Besides the high-speed, XE3301 bps data transfer, the XE3301 supports data compression, error correction and fax transfer. The XE3301 also inlcudes NVRAM for permanent storage of the modem configuration.
The XE3301 is pin compatible with Xecom's XE2401, XE9601 and XE1401 modems. This family of modems permits a simple upgrade path from 2400 bps to 33,600 bps.
Features
*
Models for North America, Japan, and Europe
Country Model Canada XE3301 Japan XE3301 France XE3301F Germany XE3301G Italy XE3301I UK XE3301B USA
1
XE3301
1
(user transferable FCC Registration)
*
Small Size: 2.75 inches by 1.38" by 0.42"
*
Modem Protocols: V.34bis (33,600 bps), V.34, V.32bis, V.32, V.22bis, V.22, V.21, Bell 212A and 103
*
Fax Protocols: V.17 (14,400 bps), V.29, V.27ter, and V.21 channel 2
*
Error Correction; V.42, MNP2-4 and MNP10
*
Data Compression; V.42bis and MNP5 provides a maximum effective data rate of 133,400 bps.
*
Pin compatible upgrade for Xecom's XE2401, XE9601, and XE1401 modems
Block Diagram
Modem
Controller
ROM
NVRAM
Analog
Front
End
DAA
/DTR /RTS /CTS /DSR
TXD
RXD
/DCD
/RI
Serial I/O
RESET
AR
/LCS
OH
AMP
Tip
Ring
Auxiliary I/O
Page 2
XECOM (2) XE3301
XE3301 Mechanical Specifications
A 2.74 2.760 69.60 70.10 B 1.370 1.390 34.80 35.31 C 0.400 0.420 10.16 10.67 D 0.890 0.910 22.61 23.11 E 1.890 1.910 48.01 48.51 F 0.125 0.200 3.18 5.08 G 0.080 0.100 2.03 2.54 H 0.415 0.435 10.54 11.05 J 0.090 0.110 2.29 2.79 K 0.020 0.025 0.51 0.64 L 0.380 0.400 9.65 10.16 M 0.090 0.110 2.29 2.79
Pins = 0.025 inch square pin All pins tin-plated
INCHES METRIC(MM)
PIN MIN MAX MIN MAX
XE3301 PIN CONFIGURATION
RESET
N/C
RXD
/DTR /LCS /CTS
OH
TXD
/RTS
NC
/RI
TIP
RING
VCC /DSR /DCD
AMP GND
1 2 3
9 10 11 12 13 14 15 16
18
20
40 39 38
22 21
Page 3
XECOM (3) XE3301
1 RESET Hardware reset pin, Input, active High, TTL. A high on Pin 1 initiates a hardware
reset. An external reset is not required or recommended. The Reset pulse must be
a minimum of 100 milliseconds long. 2 N/C 3 RXD Received Data, Output, TTL. Serial data output to the host. A logic "High" on RXD
represents a "mark" and a logic "Low" represents a "space". 9 \DTR Data Terminal Ready, Input, active Low, TTL. The "AT&D" command sets the
function of DTR. The default, AT&D2, requires the host to assert DTR to permit a
modem link. The modem drops the call in progress if DTR is revoked and will not
connect until DTR is re-asserted.
10 \LCS Loop Current Sense, active Low Input, TTL. A low on \LCS tells the modem that
loop current is flowing through Tip and Ring. This feature is used only in the
XE3301B version.
11 \CTS Clear to Send, Output, active Low, TTL/CMOS. CTS is used as a Flow Control
output from the modem. The modem revokes CTS with hardware flow control active
to signal the host that the modem's input buffer is full. The modem reasserts CTS
when the buffer can accept more data without a buffer overflow.
12 OH Off-Hook, Output, active High. OH indicates the modem's hookswitch relay is
closed. Hookswitch closure connects the modem to the telephone line.
13 TXD Transmit Data, Input, TTL. Serial data input from the host. A logic "High" represents
a "mark" and a Low represents a"space", TTL.
14 \RTS Request to Send, input, active LOW, TTL. The XE3301 uses RTS for hardware flow
control. When RTS is revoked and hardware flow control is enabled, the modem will
not place data RXD.
15 NC No Internal Connection 16 \RI Ring Indicator, Output, active Low, TTL. When low indicates the modem is receiving
a ring signal.
18 TIP Tip connection to the phone line(RJ11 pin3) from the internal DAA. The XE3301 is
not sensitive to the battery voltage polarity across Tip and Ring.
20 RING Ring connection to the phone line(RJ11 pin4) from the internal DAA. 21 GND Ground (0 volts)
PIN NAME DESCRIPTION
XE3301 Pin Descriptions
Page 4
XECOM (4) XE3301
PIN NAME DESCRIPTION
XE3301 Pin Descriptions
22 AMP Audio Output function is set by L & M commands and the value in register S22. This
output can drive a minimum load of 300 ohms.
38 \DCD Data Carrier Detect, Output, active Low, TTL/CMOS. &C sets the DCD function. In
the default condition, AT&C1, DCD indicates the presence of a carrier signal on the
telephone line.
39 \DSR Data Set Ready, Output, active Low, TTL/CMOS. &S sets the DSR function. In the
default condition, AT&S0, DSR is forced true.
40 Vcc +5 Volts
ABSOLUTE MAXIMUM RATINGS*
SUPPLY VOLTAGE - Vcc +6.5 Volts
DC INPUT VOLTAGE -0.6 Volts to +6.5 Volts
STORAGE TEMPERATURE RANGE -25° C TO +85° C
LEAD TEMPERATURE (Soldering, 2 sec per wave) 260° C
OPERATING TEMPERATURE RANGE 0 TO 70° C
*Exceeding these values may result in permanent damage to the device.
XE3301 ELECTRICAL SPECIFICATIONS
VCC 4.75 5.25 Volts ICC 170 200 220 mamps On Line
50 mamps Idle
Ring Voltage Detected 38 150 RMS XE3301
10 RMS XE3301B, XE3301I
20 RMS XE3301G Ring Frequency Detected 15.3 68 Hz Telephone Loop Current 10 100 mamps XE3301
10 120 mamps XE3301B, XE3301I
10 60 mamps XE3301G
10 45 mamps XE3301F Data Transmit level -12 -10.5 -9.0 dBm DTMF Transmit Level -2.5 0 dBm Avg over 3 second interval Billing tone Filter 16 KHz XE3301G Only
Parameter Min Typ Max Units Comments
Page 5
XECOM (5) XE3301
XE3301 Typical Applications Schematic
Note: RJ11 Pin assignments reflect a 6-pin connector. Tip and Ring are always the center pins of the
RJ11 jack.
Recommended Parts
Reference Designation Description Recommended Part Number
L1, L2 Ferrite Beads TDK CB30-1812
C1, C2 Capacitors Sprague 30GAT47, 470 pfd, 3000 Volts
J1 RJ11 Jack Stewart SS6446NF
Page 6
XECOM (6) XE3301
XE3301 AT Commands
Modes of Operation
The XE3301 uses "AT" commands for control and
configuration. The XE3301 operates in three modes; Command Mode, Fax Mode and Data Mode. Extensions to the AT command set support
fax operation.
Data Mode: The modem enters data mode after it establishes a link and issues a "CONNECT" result code. In Data Mode the modem modulates all signals on Transmit Data, Pin 13, and sends them to the remote modem. The modem demodulates the signal from the remote modem and places it onto Received Data, Pin 3, for the host equipment. When the modem exits data mode, it issues a "NO CARRIER" result code.
Command Mode: The XE3301 enters command mode on application of power, reset, loss of the connection, or receipt of the escape sequence. In command mode the modem accepts commands from the host on Transmit Data. Appropriate result codes are returned on Received Data at the same speed and parity as the commands.
Fax Mode: The modem enters fax mode on receipt of the AT+FCLASS=1 command. Fax commands and responses are issued at 19,200 bits per second; the character format is 8 bits no parity. The modem accepts Class 1 Fax commands only in fax mode. The A/, ATO, AT&T and escape commands are not valid in fax mode.
Commands
The modem is configured and controlled with AT commands. AT commands follow a strict format. The command line is stored in the command buffer and executed upon receipt of a carriage return. Until executed, the command line can be edited with the backspace key.
Command Format - Each command, except A/, begins with the AT prefix. The "A" and "T" may be both upper case or both lower case but cannot be of different cases. The modem uses the prefix to identify the host's speed and parity. The modem determines speed by measuring the width of the incoming bits and parity by comparing the parity bits of the "A" and "T." The modem then returns result codes at the host's speed and parity.
Command Line - A command line may include multiple commands. The modem executes the commands in the sequence they appear in the command line. Spaces, inserted to improve legibility, do not fill space in the command buffer. A carriage return terminates the command line and causes the commands to be executed. Register S3 allows the user to select a character other than a carriage return to terminate the command line.
Command Buffer - The command buffer holds 40 characters, including the AT prefix. If it overflows, the modem issues an "ERROR" result code and commands are not executed.
Command Line Editing - A backspace can be used to edit the command any time before it is executed. The backspace character, Control and H simultaneously on some systems, erases the previous character in the command line. Any character except for the "A" and "T" can be erased. Register S5 allows the user to select a character other than a backspace to edit the command line.
Re-Execute Last Command - The A/ command causes the modem to re-execute the command line stored in the command buffer. This is the only command which does not require the "AT" prefix.
Omitted Parameters - Most commands include a parameter which determines the command function. When the parameter is omitted from the command string, it is assumed to be a 0.
Page 7
XECOM (7) XE3301
Escape Characters - A three character escape
sequence, entered while in data mode, will switch the modem into command mode while remaining on line. The escape character, set by Register S2, is entered 3 times in succession to execute the
escape. The default escape sequence is "+++."
Result Codes - The modem issues a result code
after each action. Result codes may be provided as full words, numeric codes or may be disabled. Each result code ends with a carriage return when numeric result codes are chosen. When full word result codes are chosen, a Line Feed and Carriage Return precede and follow each result code.
List of Commands
An asterisk indicates the default setting of the command for the XE3301. The default setting may be different for the European models.
A - Answer Command - ATA forces the modem to immediatly go off-hook and begin transmittting the answer tone sequence.
Bn - Select Communications Standard - ATBn selects the modulation scheme used for connections below 2400 bits per second
n=0 Selects CCITT standards n=1 Selects Bell standards*
D - Dial Command - Below are the characters accepted in a dialing command. 0-9, #, * =Dialing Digits
L = Re-dial last number P = Pulse dial T = Tone dial
S=n = Dial stored number
W = Wait for dial tone ^ = Toggles state of calling tone , = Pause for the duration of S8 @ = Wait for silence ! = Switch hook flash ; = Return to the command state
En - Command Echo - ATEn determines whether commands will be echoed back to the host.
n=0 Do not echo commands n=1 Enable command echo*
Hn - Switch Hook Control - ATHn opens and closes the modem's hook switch.
n=0 Switch hook relay opens n=1 The switch hook relay closes
In - Modem Identification - ATIn Identifies the version of the modem.
Ln - Speaker Volume - ATLn sets the amplitude of the modem's audio output.
n=0 Lowest speaker volume n=1 Low speaker volume* n=2 Moderate speaker volume n=3 High speaker volume
Mn - Speaker Activity - ATMn determines when the modem's audio output is active.
n=0 Speaker off n=1 Speaker on until carrier received* n=2 Speaker remains on n=3 Speaker off during dialing, on until carrier
Nn - Data Rate - ATNn selects whether or not the modem will negotiate a lower data link speed.
n=0 Handshake only at DTE rate n=1 Negotiate highest common speed*
On - On Line - ATOn switches the modem from the command mode to the data mode.
n=0 Return On Line with no retrain* n=1 Initiate retrain returning On Line.
Qn - Responses - ATQn determines if the modem will issue responses.
n=0 Send responses* n=1 No Responses
Sr? - Interrogate Register - ATSr? requests the current value in register Sr.
XE3301 AT Commands (continued)
Page 8
XECOM (8) XE3301
Sr=n - Set Register Value - ATsr=n sets the value of register Sr to n.
Vn - Result Codes - ATVn sets the modem to issue Numeric or Full Word result codes .
n=0 Numeric Result Codes
n=1 English Word Result Codes*
Wn - Connect Message Rate - ATWn determines
whether the data rate reported in the Connect response is the host data rate, the link data rate or whether both are provide along with the error control and data compression protocols negotiated.
n=0 Send "CONNECT" at DTE Rate*
n=1 Report line speed, DTE speed and Link
protocol
n=2 "CONNECT" Reports Link speed
Xn - Result Code Set - ATXn selects which set of result codes the modem may send.
n=0 Result codes 0 to 4 n=1 Result codes 0 to 5 and 10 n=2 Result codes 0 to 6 and 10 n=3 Result codes 0 to 5, 7 and 10 n=4 Full Result codes*
Yn - Long Space Disconnect - ATYn determines
if the modem will automatically disconnect if a continuous space is received for 1.6 seconds.
n=0 Long Space Disconnect Disabled* n=1 Disconnect on long space
Zn - Reset - ATZn executes a soft reset to the
modem and resets the modem configuration.
n=0 Reset to user profile 0* n=1 reset to user profile 1
&Cn - DCD Operation - AT&Cn determines the operation of the DCD output.
n=0 DCD is forced active. n=1 DCD indicates a valid carrier*
&Dn - DTR - AT&Dn determines how the modem will respond to changes to DTR.
n=0 DTR is ignored by the modem. n=1 Enter command mode if DTR revoked. n=2 Disconnect if DTR revoked.* n=3 Soft reset when DTR revoked
&Fn - Return to Factory Defaults - AT&Fn returns the modem configuration to one of two factory configurations.
n=0 Restore configuration 0* n=1 Restore configuration 1
&Gn - Guard Tone - AT&Gn controls the guard tone produced by the modem
n=0 Guard Tone Disabled* n=1 Guard Tone Disabled n=2 1800 Hz Guard Tone
&Kn - Flow Control - AT&Kn selects the flow control method used by the modem.
n=0 Disabled n=3 RTS/CTS n=4 XON/XOFF n=5 Transparent XON/XOFF n=6 RTS/CTS and XON/XOFF
&Pn - Dial Pulse Make/Break Ratio - AT&Pn determines the specific pulse dialing parameters used by the modem.
n=0 39/61% @ 10 pps* n=1 33/67% @ 10 pps n=2 39/61% @ 20 pps n=3 33/67% @ 20 pps
&Qn - Line Connection - AT&Qn determines if error control or data buffering aare active on the link.
n=0 Direct mode (no data buffering)* n=5 Use Error Correction n=6 Normal Mode (Speed buffering)
XE3301 AT Commands (continued)
Page 9
XECOM (9) XE3301
&Sn - DSR Operation - AT&Sn sets the operation of the DSR signal.
n=0 DSR always active* n=1 DSR in accordance with V.25.
&Tn - Test Modes - AT&T selects modem test
modes.
n=0 Exit test mode n=1 Local analog loopback n=3 Initiate local digital loopback n=4 Respond to remote loop request* n=5 Deny remote loop request n=6 Initiate a Remote Digital loopback n=7 Remote digital loopback w self-test n=8 Local analog loopback w self-test
&Vn - View Configuration Profiles - AT&V
permits the user to check on the modems current configuration.
n=0 View active profile & user profile 0* n=1 View active profile & user profile 1
&Wn - Store Active Profile - AT&Wn stores the current modem configuration in NVRAM.
n=0 Store active profile as profile 0* n=1 Store active profile as profile 1
&Yn - Recall Stored Profile - AT&Yn sets the stored modem configuration to be used after a hard reset.
n=0 Recall profile 0 on power-up* n=1 Recall profile 1 on power-up
&Zn=x - Store telephone number "x" in
memory location "n"
%En - Line Quality Monitor/Auto Retrain -
AT%En determines if the modem will monitor line quality during a connection and intiate a retrain if quality drops below acceptable levels.
n=0 Disabled n=1 Enabled n=2 Line quality, fallback, fall forward
%L - Read Received Signal Level - AT%L permits the user to read the magnitude of the recevie singal in dBm.
%Q - Read Line Signal Quality - AT%Q permits the user to read the EQM value of the recevied signal.
\An - MNP Block Size - AT|An sets the block size for MNP data packets.
n=0 Maximum 64 characters n=1 Maximum 128 characters n=2 Maximum 192 characters n=3 Maximum 256 characters*
\Bn - Transmit Break - AT\Bn selects the duration of the break signal sent. Break = n x 100 msec.
\Kn - Break control - AT\Kn determines how the modem will handle a break signal.
Break received from host with Reliable link.
n=0 Enter on-line command mode; do not
transmit break
n=1 Purge buffers, immediately transmit
break n=2 Same as n=0 n=3 Immediately send break n=4 same as n=0 n=5 Send break in sequence with data*
Break received from host with Direct link .
n=0 Immediately transmit break, then enter
on-line command mode n=1 Immediately send break n=2 Enter command mode but do not transmit
break signal n=3 same as n=1 n=4 same as n=0 n=5 same as n=1*
XE3301 AT Commands (continued)
Page 10
XECOM (10) XE3301
Break received from modem w Normal link.
n=0 Purge buffers, Immediately send break to
the host n=1 same as n=0 n=2 Immediately send break to the host n=3 Same as n=2 n=4 Send break in sequence with data. n=5 Same as n=2*
Host initiates break with \B command on Reliable link.
n=0 Purge buffers and immediately transmit
break n=1 Same as n=0 n=2 Immediately transmit break n=3 Same as n=1 n=4 Transmit break in sequence w data n=5 Same as n=4
\Nn - Error Control Selection - AT\Nn deteermines how the modem will handle error control negotiations.
n=0 Normal mode, no error correction n=1 Direct mode, no buffering, no error
correction
n=2 Reliable mode, error correction required
for connection
n=3 V.42 Auto-reliable mode, accept either an
error controlled or non-error controlled
link* n=4 V.42 Reliable mode, LAPM required n=5 MNP required
\Vn - Single Line Result Codes - AT/Vn determines if the Connect response will be issued in a single line format. The single line format is shown. CONNECT<DTE Speed><Modulation> <Protocol><Compression><Link Speed>
n=0 Responses per ATX, ATW and S95* n=1 Single Line Responses
-Kn - MNP Extended Services - AT-Kn determines how the modem handles MNP10.
n=0 No LAPM to MNP10 conversion n=1 LAPM to MNP10 conversion* n=2 LAPM to MNP10 conversion but no MNP
Extended Service during V.42 LAPM answer mode detect.
XE3301 AT Commands (continued)
Page 11
XECOM (11) XE3301
XE3301 AT Commands (continued)
Class 1 Fax Commands
The Class 1 Fax Commands are used to control the modem in Fax Mode.
AT+FCLASS? - Service Class Indication
n=0 Configured as a data modem n=1 Configured for Service Class 1.
AT+FCLASS=? - Shows Service Class Capability
n=0 Configured as a data modem n=1 Configured for Service Class 1.
AT+FCLASS=n - Sets Service Class
n=0 Configured as a data modem n=1 Configured for Service Class 1.
AT+FAE=n - Selects Data/Fax Auto Answer
n=0 Answer as a fax modem only n=1 Either a fax or data modem
AT+FRS=n - Receive Silence
This command causes the modem to issue an OK response after detecting silence for n * 10 milliseconds.
AT+FTS=n - Stop Transmission and Wait
This command causes the modem to stop transmission for n * 10 milliseconds before issuing the OK response
AT+FRH=n - Receive HDLC Data Frames
n=3 V.21 Channel 2, 300 bps
n=24 V.27ter, 2400 bps
n=48 V.27ter, 4800 bps
n=72 V.29, 7200 bps
n=73 V.17, long training, 7200 bps
n=74 V.17, short training, 7200 bps
n=96 V.29, 9600 bps
n=97 V.17, long training, 9600 bps
n=98 V.17 short training, 9600 bps
n=121 V.17, long training, 12,000 bps
n=122 V.17 short training, 12,000 bps
n=145 V.17, long training, 14,400 bps
n=146 V.17 short training, 14,400 bps
AT+FRM<mod> - Receive Fax
n=24 V.27ter, 2400 bps n=48 V.27ter, 4800 bps n=72 V.29, 7200 bps n=73 V.17, long training, 7200 bps n=74 V.17, short training, 7200 bps n=96 V.29, 9600 bps n=97 V.17, long training, 9600 bps n=98 V.17 short training, 9600 bps n=121 V.17, long training, 12,000 bps n=122 V.17 short training, 12,000 bps n=145 V.17, long training, 14,400 bps n=146 V.17 short training, 14,400 bps
AT+FTH=n- Transmit HDLC Data
n=3 V.21 Channel 2, 300 bps n=24 V.27ter, 2400 bps n=48 V.27ter, 4800 bps n=72 V.29, 7200 bps n=73 V.17, long training, 7200 bps n=74 V.17, short training, 7200 bps n=96 V.29, 9600 bps n=97 V.17, long training, 9600 bps n=98 V.17 short training, 9600 bps n=121 V.17, long training, 12,000 bps n=122 V.17 short training, 12,000 bps n=145 V.17, long training, 14,400 bps n=146 V.17 short training, 14,400 bps
AT+FTM<mod> - Transmit Fax
n=24 V.27ter, 2400 bps n=48 V.27ter, 4800 bps n=72 V.29, 7200 bps n=73 V.17, long training, 7200 bps n=74 V.17, short training, 7200 bps n=96 V.29, 9600 bps n=97 V.17, long training, 9600 bps n=98 V.17 short training, 9600 bps n=121 V.17, long training, 12,000 bps n=122 V.17 short training, 12,000 bps n=145 V.17, long training, 14,400 bps n=146 V.17 short training, 14,400 bps
Page 12
XECOM (12) XE3301
XE3301 AT Commands (continued)
S-Registers
Following are descriptions of the S-Registers Supported by the XE3301.
S0 Answer on nth Ring: S0 sets the modem
to automatically answer on the nth ring. Setting S0 to 0 disables automatic answer.
Range: 0 to 255 Units Rings Default 0
S1 Ring Count: S1 is a read-only register. It
shows the number of rings detected. If a ring is not detected within 8 seconds, the counter is reset to zero.
Range: 0 to 255 Units Rings Default 0
S2 Escape Character: S2 determines the
ASCII character used in the escape sequence. Values of 0-127 select valid ASCII escape characters; values from 128 to 255 disable the escape sequence.
Range: 0 to 255 Units ASCII Character Default 43 (+)
S3 Carriage Return Character: S3 determines
the ASCII character to serve as a carriage return to terminate commands and to be inserted in modem responses.
Range: 0 to 127 Units ASCII Character Default 13 (Carriage Return)
S4 Line Feed Character: S4 sets the ASCII
character to act as a line feed character in modem responses.
Range: 0 to 127 Units ASCII Character Default 10 (Line Feed)
S5 Back Space Character: S5 defines the
ASCII character used as a backspace to edit the command line.
Range: 0 to 32 Units ASCII Character Default 8 (Back Space)
S6 Dial Tone Wait Time: S6 determines how
long the modem waits for dial tone before dialing begins. The Dial Tone Wait Time cannot be set to less than two seconds.
Range: 2 to 255 Units Seconds Default 2
S7 Wait for Carrier after Dialing: S7
determines how long the modem waits for a valid carrier signal after dialing is completed.
Range: 1 to 255 Units Seconds Default 50
S8 Comma Pause Time: S8 defines the
duration of the pause initiated by a comma in the dialing string. The pause is generally used when waiting for a second dial tone.
Range: 1 to 255 Units Seconds Default 50
S9 Carrier Detect Response Time: S9
establishes the length of time the remote modem's carrier must be present to be recognized as valid.
Range: 1 to 255 Units 0.1 Seconds Default 6
Page 13
XECOM (13) XE3301
S10 Carrier Off Disconnect Delay: S10 selects
how long carrier must be lost before the modem disconnects. Note: If S10 is smaller than the value of S9, the modem will not automatically disconnect on loss of carrier.
Range: 1 to 255 Units 0.1 Seconds
Default 14
S11 Tone Dialing Speed: S10 sets the duration
and spacing of the dialing tones. S11 does
not affect the pulse dialing rate.
Range: 50 to 255 Units 1 Millisecond Default 95
S12 Escape Code Guard Timer: S12 sets the
escape sequence guard timer. If characters are received before or after the escape
sequence, within the guard timer, the modem aborts the escape attempt and remains in data mode.
Range: 0 to 255 Units 0.02 Seconds Default 50
S14 General Bit-Mapped Options: S14 reflects
the state of several "AT" commands. Bit 0 Not Used Bit 1 0 = Echo Disabled (ATE0)
1 = Echo Active (ATE1)
Bit 2 0 = Send Result Codes (ATQ0)
1 = No Result Codes (ATQ1)
Bit 3 0 = Numeric Result Codes (ATV0)
1 = Full Word Result Codes (ATV1) Bit 4 Not Used Bit 5 0 = Tone Dialing Selected (T)
1 = Pulse Dialing Selected (P)
Bit 6 Not Used Bit 7 0 = Answer
1 = Originate
S16 Test Status: S16 shows the test status of
the modem. Bit 0 0 = No Local Analog Loopback
1 = Local ALB Active Bit 1 Not Used Bit 2 0 = Local Digital Loopback Disabled
1 = Local DLB Enabled Bit 3 0 = No Remote Digital Loopback
1 = Remote DLB Active Bit 4 0 = Remote DLB not requested
1 = Remote DLB Requested Bit 5
0 = Remote DLB w Self-Test Disabled
1 = Remote DLB w Self-Test Enabled Bit 6
0 = Local ALB w Self-Test Disabled
1 = Local ALB w Self-Test Enabled Bit 7 Not Used
S18 Test Timer: S18 determines the duration of
any test mode. If S18 equals 0, the AT&T0 command terminates the test.
Range: 0 to 255 Units Seconds Default 0
S21 General Bit-Mapped Options: S21 reflects
the state of several "AT" commands. Bit 0-2 Not Used Bit 3,4 0 = DTR ignored (AT&D0)
1 =
Enter command mode on DTR off
(AT&D1) 2 = Disconnect on DTR off (AT&D2) 3 = Reset on DTR off (AT&D3)
Bit 5 0 = DCD always active (AT&C0)
1 = DCD on with Carrier (AT&C1)
Bit 6 0 = DSR always active (AT&C0)
1= DSR on when modem ready
(AT&C1)
Bit 7 0 = No disconnect on Space (ATY0)
1 = Disconnect on Space (ATY1)
XE3301 AT Commands (continued)
Page 14
XECOM (14) XE3301
S22 General Bit-Mapped Options: S22 reflects
the state of several "AT" commands. Bit 0-1 0 = Low speaker volume (ATL0)
1 = Low speaker volume (ATL1) 2
= Moderate speaker volume (ATL2)
3 = High speaker volume (ATL3)
Bit 2-3 0 = Speaker off (ATM0)
1 = Speaker off with carrier (ATM1) 2 = Speaker always on (ATM2) 3 = Speaker on during handshake
(ATM3)
Bit 4-6 0 = Basic Result codes (ATX0)
4
= Connect speed result codes (ATX1) 5 = No Blind Dial (ATX2) 6 = Busy Detection (ATX3) 7 = Full result codes (ATX4)
Bit 7 Not Used
S23 General Bit-Mapped Options: S23 reflects
the state of several "AT" commands.
Bit 0 0 = Remote DLB Disabled (AT&T5)
1 = Remote DLB Allowed (AT&T4)
Bit 1-3 0 = Host Interface at 300 bps
1 = Host Interface at 600 bps 2 = Host Interface at 1200 bps 3 = Host Interface at 2400 bps 4 = Host Interface at 4800 bps 5 = Host Interface at 9600 bps 6 = Host Interface at 19200 bps 7 = Host I/F at 38400 bps or higher
Bit 4-5 0 = Even parity in use
1 = Not used 2 = Odd Parity in use 3 = No Parity in use
Bit 6-7 0 = No Guard Tone (AT&G0)
1 = No Guard Tone (AT&G1) 2 = 1800 Hz guard tone (AT&G2) 3 = Not Used
S24 Sleep Inactivity Timer: S24 sets the length
of time the modem will remain inactive before it enters the low power sleep mode. If S24 equals 0 sleep mode is disabled.
Range: 0 to 255 Units 1 Seconds Default 0
S27 General Bit-Mapped Options: S27 reflects
the state of several "AT" commands. Bit 0 1 3
0 0 0 = Normal Mode (AT&Q0) 1 0 1
= Error control enabled (AT&Q5)
0 1 1
= Direct Mode (AT&Q6) Bit 2 Not Used Bit 4-5 Not Used Bit 6 0 = CCITT Protocols (ATB0)
1 = Bell Protocols (ATB1)
Bit 7 Not Used
S28 Pulse Dialing Bit-Mapped Options: S28
stores the modem's pulse dialing configuration.
Bit 0-2 Not Used Bit 3-4 0 = Make/Break ratio 39%/61%; 10
pulses per second (AT&P0)
1 = Make/Break ratio 33%/67%; 10
pulses per second (AT&P1)
2 = Make/Break ratio 39%/61%; 20
pulses per second (AT&P2)
3 = Make/Break ratio 33%/67%; 20
pulses per second (AT&P3)
Bit 5-7 Not Used
S29 Hook Flash Timer: S29 determines the
length for time the modem will close its off­hook relay on reciept of the "!" dial modifier to simulate a switch hook flash.
Range: 0 to 255 Units 10 milliseconds Default 70
XE3301 AT Commands (continued)
Page 15
XECOM (15) XE3301
XE3301 AT Commands (continued)
S30 Disconnect on Inactivity Timer: S30 sets
the modem to disconnect after the given time period with no data being sent or
received. A 0 disables the inactivity timer. Range: 0 to 255
Units 10 Seconds
Default 0
S31 General Bit-Mapped Options: S31 stores
the status of various AT commands.
Bit 0 0 =
No single-line Connect messages
(AT\V0)
1 =
Use single-line connect messages (AT\V1)
Bit 1 0 = No Automode detection (ATN0)
1 =
Automode detection active (ATN1)
Bit 2-3 0 = Report host speed (ATW0)
1 = Report all parameters (ATW1) 2 =
Report modem speed only (ATW2)
Bit 4-7 Not Used
S32 XON Character: S32 determines the ASCII
character to be sent as XON for in-band flow control.
Range: 0 to 255 Units ASCII Character Default 11 (VT)
S33 XOFF Character: S32 determines the
ASCII character to be recognized as XOFF for in-band flow control.
Range: 0 to 255 Units ASCII Character Default 19 (DC3)
S36 LAPM Failure: S36 instructs the modem
what to do if the error control negotiations fail.
Bit 0-2 0 = Modem Disconnects
1 = Establish Direct Connection 3 = Establish normal Connection 4 = Disconnect if MNP handshake
fails
5 = Establish Direct Connection if
MNP handshake fails.
7 = Establish Normal Connection if
MNP handshake fails.
Bit 3-7 Not Used
S38 Forced Disconnect Timer: S38 sets the
delay between receipt of the command to disconnect and the actual opening of the switch hook. If S38 is set to 255 the modem disconnects only after its buffers are empty.
Range: 0 to 255
Units 1 Second Default 20
S39 Flow Control Bit-Mapped Options: S39
shows the status of the modem's flow control options, AT&K.
Bit 0-2 0 = Flow Control Disabled
3 =
Hardware Flow Control, RTS/CTS
4 =
In-Band Flow Control XON/XOFF
5 =
Transparent In-Band Flow Control
6 = Both Harware and In-Band Flow
Control
Bit 3-7 Not used
Page 16
XECOM (16) XE3301
XE3301 AT Commands (continued)
S40 MNP Bit-Mapped Options: S40 shows the
status of the modem's MNP commands, . Bit 0-1 0 = No LAPM to MNP10 conversion
(AT-K0)
1 = Enable LAPM to MNP10
conversion (AT-K1)
2 = Enable LAPM to MNP10
conversion except for LAPM answer mode (AT-K1)
Bit 2 Not Used
Bit 3-5 0 = AT\K0 break handling selected
1 = AT\K1 break handling selected 2 = AT\K2 break handling selected 3 = AT\K3 break handling selected 4 = AT\K4 break handling selected 5 = AT\K5 break handling selected
Bit 6-7 0 = MNP Block size 64 characters
1 = MNP Block size 128 characters 2 = MNP Block size 192 characters 3 = MNP Block size 256 characters
S41 General Bit-Mapped Options: S41 stores
the condition of various "AT" commands. Bit 0-1 0 = No Data Compression (AT%C0)
1 = MNP5 Data Compression
(AT&C1)
2 = V.42bis Data Compression
(AT&C2)
3 = Either MNP5 or V.42bis Data
Compression (AT&C3)
Bit 2, 6
0 0 = No Fallback/Forward (AT%E0) 1 0 = Retrain Enabled (AT%E1) 0 0 = Fallback/Forward Enabled
(AT%E2)
Bit 3-5, 7 Not Used
S46 Data Compression Control: S46 selects
whether or not the modem will support data compression with error control.
S46=136 No data compression S46=138 Data Compression selected
Default 138
S48 V.42 Negotiations: S48 determines the
modem's V.42 negotiation process.
S48=0 Proceed with LAPM S48=7 Negotiate per V.42
S48=128 Assume LAPM failure
Default 7
S86 Call Failure Code: S86 shows why the last
"NO CARRIER response was issued.
S86=0 Normal Disconnect S86=4 Loss of Carrier S86=5 V.42 Negotiation Failure S86=9 Modem Handshake Failure
S86=12 Disconnect Initiated by remote
modem S86=13 No response after 10 retries S86=14 Protocol Violation
S95 Extended Result Codes: S95 permits the
user to customize the extended result codes. Bit 0 Connect result code shows link
speed Bit 1 Add /ARQ to connect response Bit 2 Add /VFC to Carrier response Bit 3 Enable Protocol response Bit 4 Not Used Bit 5 Enable Compression Result Code Bit 6 Not used Bit 7 Not Used
Page 17
XECOM (17) XE3301
XE3301 Result Codes
Digits Verbose Description
0 OK Successfully executed
command line 1 CONNECT 300 bps connection 2 RING Ring signal detected 3 NO CARRIER Carrier not detected/lost 4 ERROR Error in command line 5 CONNECT 1200 1200 bps connection 6 NO DIAL TONE No dial tone detected 7 BUSY Busy signal detected 8 NO ANSWER 5 second silence not
detected
10 CONNECT 2400 2400 bps Connection 11 CONNECT 4800 4800 bps Connection 12 CONNECT 9600 9600 bps Connection 13 CONNECT 7200 7200 bps Connection 14 CONNECT 12000 12,000 bps Connection 15 CONNECT 14400 14,400 bps Connection 16 CONNECT 19200 19,200 bps Connection 17 CONNECT 38400 38,400 bps Connection 18 CONNECT 57600 57,600 bps Connection 19 CONNECT 115200 115200 bps Connection 22 CONNECT 75TX/1200RX
V.23 originate connection
23 CONNECT 1200TX/75RX
V.23 answer connection
33 FAX Fax connection 35 DATA Data connection in Fax
mode
40 CARRIER 300 300 bps carrier received 44 CARRIER 1200/75 V.23 reverse channel
carrier received
45 CARRIER 75/1200 V.23 forward channel
carrier received
46 CARRIER 1200
1200 bps carrier received
47 CARRIER 2400
2400 bps carrier received
Digits Verbose Description
48 CARRIER 4800
4800 bps carrier received
49 CARRIER 7200
7200 bps carrier received
50 CARRIER 9600
9600 bps carrier received
51 CARRIER 12000
12,000 bps carrier received
52 CARRIER 14400
14,400 bps carrier received
53 CARRIER 16800
16,800 bps carrier received
54 CARRIER 19200
19,200 bps carrier received
55 CARRIER 21600
21,600 bps carrier received
56 CARRIER 24000
24,000 bps carrier received
57 CARRIER 26400
26,400 bps carrier received
58 CARRIER 28800
28,800 bps carrier received 59 CONNECT 16800 16,800 bps Connection 61 CONNECT 21600 21,600 bps Connection 62 CONNECT 24000 24,000 bps Connection 63 CONNECT 26400 26,400 bps Connection 64 CONNECT 28800 28,800 bps Connection 66 COMPRESSION: CLASS 5
MNP5 data compression
67 COMPRESSION: V.42bis
V
.42bis data compression
69 COMPRESSION: NONE
No data compression 76 PROTOCOL: NONE No error correction 77 PROTOCOL: LAPM LAPM error correction 80 PROTOCOL: ALT MNP error correction 81
PROTOCOL: ALT CELLULAR
MNP10 error correction
+F4 +FCERROR Fax carrier error
Page 18
XECOM (18) XE3301
Using the XE3301 in the US
All equipment connected to the public telephone network in the United States must have FCC Part 68 Registration. Part 68 registration certifies that the device will not cause harm to the telephone network. The XE3301 provides a user transferable FCC Registration. This permits XE3301 customers to use our FCC registration number without submitting their systems for additional testing. Call Xecom technical support at 408­945-6640 with any questions on whether your system qualifies to use Xecom's FCC Registration Number.
In your operating instructions you must provide certain information to the end user of the modem. The instructions should include most of the instructions shown below. Only the information regarding the mounting of the device in the final assembly should be omitted.
FCC Instructions:
T
his product complies with Part 68 of the FCC Rules and Regulations. On each device shipped, there is a label which contains, among other information, the FCC Registration Number and Ringer Equivalence Number (REN) for this product. You must, upon request, provide this information to your telephone company.
The mounting of this device in the final assembly must be made in such a manner as to preserve the high voltage protection between the TIP/RING Connection and the rest of the system. Typically, this may be accomplished by maintaining a minimum spacing .100 mils between the TIP/RING Traces to the RJ-11C Jack and low voltage portion of the system. No additional circuitry may be attached between TIP/RING and the telephone line connection, unless specifically allowed in the rules.
The REN is useful to determine the quantity of devices you may connect to a telephone line and still have all of these devices ring when the number is called. In most, but not all areas, the sum of the RENs of all devices connected to one line should not exceed five (5.0). To be certain of the number of devices you may connect to the line, as determined by the REN, you should contact the local telephone company to determine the maximum REN for your calling area.
If your system causes harm to the telephone network, the telephone company may discontinue service temporarily. If possible, they will notify you in advance. If advance notification is not practical, you will be notified as soon as possible.
Your telephone company may make changes in its facilities, equipment, operations or procedures that could affect proper functioning of your equipment. If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service.
If you experience trouble with this device, please contact XECOM at (408) 945-6640 for assistance. The telephone company may ask you to disconnect this device from the network until the problem has been corrected or until you are sure that the device is not malfunctioning.
The device may not be used on coin service lines provided by the telephone company (this does not apply to private coin telephone applications which use standard telephone lines). Connection to party lines is subject to state tariffs.
FCC Labels:
FCC rules also require a label which is visible from the outside of the equipment. The label should display Xecom's name as holder of the FCC Registration, the FCC Registration Number and Ringer Equivalence of the modem. This is the same information which appears on the top of each XE3301 module.
Page 19
XECOM (19) XE3301
Devices sold by XECOM are covered by the warranty provisions appearing in its Terms of Sale only. XECOM makes no warranty, express, statutory, implied, or by description regarding the information set forth herein, or regarding the freedom of the described devices from patent infringement. XECOM makes no warranty of
merchantability or fitness for any purposes. XECOM reserves the right to discontinue production and change specifications and prices at any time and without notice. This product is intended for use in normal commercial applications. Applications requiring extended temperature range, unusual environmental requirements, or high
reliability applications, such as military, medical life-support or life-sustaining equipment, are specifically not
recommended without additional processing and authorization by XECOM for such application.
Xecom assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xecom product. No other circuits, patents, or licenses are implied.
Xecom's products are not authorized for use as Critical Components in Life Support Devices or Systems.
Life Support Devices or Systemsare devices or systems which, (a) are intended for surgical implant into the
body, or (b) support or sustain life, and whose failure to perform, when properly used in accordance with instructions provided in the labeling, can be reasonably expected to result in significant injury to the user.
A Critical Component is any component of a life support device or system whose failure to perform can be reasonably expected to cause failure of the life support device or system, or to affect its safety or effectiveness.
Terms of Sale
Life Support Policy
Copyright, Xecom © 1996 While Xecom, Inc. has made every effort to ensure that the information presented here is accurate, Xecom will not be liable for any damages arising from errors or omission of fact. Xecom reserves the right to modify specifications and/or prices without notice. Product mentioned herein are used for identification purposes only and may be trademarks and/or registered trademarks of their respective companies.
Xecom Incorporated
374 Turquoise Street,Milpitas, CA 95035
Ph:408-945-6640 Fax:408-942-1346
xecom
Loading...