ISSUED
January 20, 2017
TYPE
AMRCED
PERFORMANCE DATA
3-PHASE INDUCTION MOTOR
NAMEPLATE INFORMATION
OUTPUT
HP KW
75 56.0 60
POLE VOLTAGE
6
FRAME
SIZE
405VP
230/460
TYPICAL PERFORMANCE
FULL
LOAD
RPM
FULL LOAD
MIN. % NOM. %
93.6 94.5
EFFICIENCY
3/4 LOAD
%
94.5 95.0
HZ
1/2 LOAD
RATED
AMBIENT
%
40oC
INS.
CLASS
F
POWER FACTOR
F. L.
%
86.5
ENCLOSURE
CATALOG#
NEMA
DESIGN
B
3/4 LOAD%1/2 LOAD
%
85.5 79.0
TIME
RATING
CONT.
WPI
VSP0756
SERVICE
FACTOR
1.15
MAXIMUM
POWER FACTOR
CORRECTION
KVAR18.51180
NO LOAD FULL LOAD LOCKED ROTOR
AT
208
VOLT
AT
230
VOLT
AT
460
VOLT
56.9 46.5
FULL LOAD
lb-ft
LOCKED
ROTOR
%FLT
PULL
UP
%FLT
BREAK
333.69 220 200 250
SAFE STALL
TIME IN
SECONDS
COLD HOT
17 12
ALLOWABLE
STARTS
PER HOUR
COLD HOT
2 1
AT
208
VOLT
DOWN
%FLT
CURRENTS
AT
230
VOLT
ROTOR
2
WR
2
lb-ft
31.371
AT
460
VOLT
AT
208
VOLT
AT
230
VOLT
85.9171.8 1085.0
NEMA
LOAD
2
WK
2
lb-ft
904.4
MAX
ALLOWABLE
WK
lb-ft
2
2
1317
NEMA
LOAD
WK
Sec
5.00
VOLT
542.5190.023.3
ACCEL TIMEINERTIATORQUE
2
AT
460
NEMA
KVA
CODE
LETTER
G1199.8
MAX
ALLOWABLE
WK
Sec
2
7.20
APPROVED: REVISION
M. PRATER
DRAWING NO.
31057VSP0756
0