Datasheet UT54ACTS4002, UT54ACS4002 Datasheet (Aeroflex UTMC)

Page 1
241 RadHard MSI Logic
UT54ACS4002/UT54ACTS4002
Radiation-Hardened Dual 4-Input NOR Gates
FEATURES
radiation-hardened CMOS
- Latchup immune High speed Low power consumption Single 5 volt supply Available QML Q or V processes Flexible package
- 14-pin DIP
- 14-lead flatpack
DESCRIPTION
The UT54ACS4002 and the UT54ACTS4002 are dual 4-input NOR gates. A high on any input forces the output to a low state. The circuits perform the Boolean functions:
Y = A + B + C + D = A B C D.
The devices are characterized over full military temperature range of -55 C to +125 C.
FUNCTION TABLE
LOGIC SYMBOL
PINOUTS
14-Pin DIP
Top View
14-Lead Flatpack
Top View
LOGIC DIAGRAM
INPUTS OUTPUT
An Bn Cn Dn Yn
L L L L H H X X X L X H X X L X X H X L X X X H L
Y1
(1)
(13)
Y2
(2)
A1
(3)
B1
(4)
C1
(5)
D1
(9)
A2
(10)
B2
(11)
C2
(12)
D2
Note:
1. Logic symbol in accordance with ANSI/IEEE standard 91-1984 and IEC Publication 617-12.
1
1 2
3 4 5
7
6
14 13
12
11
10
8
9
Y1 A1
B1 C1 D1
NC
V
SS
V
DD
Y2 D2 C2 B2 A2 NC
1 2
3 4 5
7
6
14 13
12
11
10
8
9
V
DD
Y2 D2 C2 B2 A2 NC
Y1 A1
B1 C1 D1
NC
V
SS
A1 B1
Y1
Y2
C1 D1
A2 B2 C2 D2
Page 2
RadHard MSI Logic 242
UT54ACS4002/UT54ACTS4002
RADIATION HARDNESS SPECIFICATIONS
1
Notes:
1. Logic will not latchup during radiation exposure within the limits defined in the table.
2. Device storage elements are immune to SEU affects.
ABSOLUTE MAXIMUM RATINGS
Note:
1. Stresses outside the listed absolute maximum ratings may cause permanent damage to the device. This is a stress rating only, functional operation of the device at these or any other conditions beyond limits indicated in the operational sections is not recommended. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
PARAMETER LIMIT UNITS
Total Dose 1.0E6 rads(Si)
SEU Threshold
2
80
MeV-cm2/mg
SEL Threshold 120
MeV-cm2/mg
Neutron Fluence 1.0E14
n/cm
2
SYMBOL PARAMETER LIMIT UNITS
V
DD
Supply voltage -0.3 to 7.0 V
V
I/O
Voltage any pin -.3 to VDD +.3 V
T
STG
Storage Temperature range -65 to +150 C
T
J
Maximum junction temperature +175 C
T
LS
Lead temperature (soldering 5 seconds) +300 C
JC
Thermal resistance junction to case 20 C/W
I
I
DC input current 10 mA
P
D
Maximum power dissipation 1 W
SYMBOL PARAMETER LIMIT UNITS
V
DD
Supply voltage 4.5 to 5.5 V
V
IN
Input voltage any pin 0 to V
DD
V
T
C
Temperature range -55 to + 125 C
Page 3
243 RadHard MSI Logic
UT54ACS4002/UT54ACTS4002
DC ELECTRICAL CHARACTERISTICS
7
(VDD = 5.0V 10%; VSS = 0V 6, -55 C < TC < +125 C)
SYMBOL PARAMETER CONDITION MIN MAX UNIT
V
IL
Low-level input voltage
1
ACTS ACS
0.8
.3V
DD
V
V
IH
High-level input voltage
1
ACTS ACS
.5V
DD
.7V
DD
V
I
IN
Input leakage current
ACTS/ACS VIN = V
DD
or V
SS
-1
1 A
V
OL
Low-level output voltage
3
ACTS ACS
I
OL
= 8.0mA
I
OL
= 100 A
0.40
0.25
V
V
OH
High-level output voltage
3
ACTS ACS
I
OH
= -8.0mA
I
OH
= -100 A
.7V
DD
VDD - 0.25
V
I
OS Short-circuit output current
2 ,4
ACTS/ACS
VO = VDD and V
SS
-200 200 mA
I
OL Output current
10
(Sink)
VIN = VDD or V
SS
VOL = 0.4V
8 mA
I
OH
Output current
10
(Source)
VIN = VDD or V
SS
VOH = VDD - 0.4V
-8 mA
P
total
Power dissipation
2, 8, 9
CL = 50pF 1.9 mW/
MHz
I
DDQ
Quiescent Supply Current VDD = 5.5V 10 A
I
DDQ
Quiescent Supply Current Delta ACTS
For input under test VIN = VDD - 2.1V
For all other inputs VIN = VDD or V
SS
V
DD
= 5.5V
1.6 mA
C
IN
Input capacitance
5
= 1MHz @ 0V 15 pF
C
OUT
Output capacitance 5
= 1MHz @ 0V 15 pF
Page 4
RadHard MSI Logic 244
UT54ACS4002/UT54ACTS4002
Notes:
1. Functional tests are conducted in accordance with MIL-STD-883 with the following input test conditions: VIH = VIH(min) + 20%, - 0%; VIL = VIL(max) + 0%,
- 50%, as specified herein, for TTL, CMOS, or Schmitt compatible inputs. Devices may be tested using any input voltage within the above specified range, but are guaranteed to VIH(min) and VIL(max).
2. Supplied as a design limit but not guaranteed or tested.
3. Per MIL-PRF-38535, for current density 5.0E5 amps/cm2, the maximum product of load capacitance (per output buffer) times frequency should not exceed 3,765 pF/MHz.
4. Not more than one output may be shorted at a time for maximum duration of one second.
5. Capacitance measured for initial qualification and when design changes may affect the value. Capacitance is measured between the designated terminal and VSS at frequency of 1MHz and a signal amplitude of 50mV rms maximum.
6. Maximum allowable relative shift equals 50mV.
7. All specifications valid for radiation dose 1E6 rads(Si).
8. Power does not include power contribution of any TTL output sink current.
9. Power dissipation specified per switching output.
10. This value is guaranteed based on characterization data, but not tested.
AC ELECTRICAL CHARACTERISTICS
2
(VDD = 5.0V 10%; VSS = 0V 1, -55 C < TC < +125 C)
Notes:
1. Maximum allowable relative shift equals 50mV.
2. All specifications valid for radiation dose 1E6 rads(Si).
SYMBOL PARAMETER MINIMUM MAXIMUM UNIT
t
PHL
Input to output 1 12 ns
t
PLH
Input to output 2 14 ns
Loading...