The µPD72042A and µPD72042B are microcomputer peripheral LSI devices for IEBus protocol control.
µ
PD72042A and µPD72042B perform all the processing required for layers 1 and 2 of the IEBus. The devices
The
incorporate large transmission and reception buffers, allowing the microcomputer to perform IEBus operations without
interruption. They also contain an IEBus driver and receiver, allowing them to directly connected to the bus directly.
FEATURES
Control of layers 1 and 2 of the IEBus protocol
••
• Support of a multi-master scheme
• Broadcast function
• Two communication modes having different
transmission speeds can be selected.
Note Parentheses indicate the state corresponding to two-wire serial I/O mode.
AVDD: Main power supply for IEBus (connected to the VDD pin)
BUS–, BUS+ : IEBus I/O
C/D: Command/data switch input
CS: Chip select input
GND: Ground
IRQ: Interrupt request output
NC: No connection
RESET: Reset input
SCK: Serial clock input
SEL: Serial mode selection
SI: Serial data input
SIO: Serial data I/O
SO: Serial data output
TEST: Test input (connected to the V
DD pin)
VDD: Main power supply
XI, XO: System clock
2
DATA SHEET S13990EJ2V0DS00
Page 3
BLOCK DIAGRAM
XIXO
µ
PD72042A, 72042B
BUS +
BUS –
Data link controller
Internal bus
Receiver
Driver
Contention
detection
section
Parity generation
section
Parity detection
section
Filter
Oscillation
control
section
Program
detection
section
P/S conversion
section
Synchronization
control section
crash
CTR
CMR
WDB
(5 bytes)
TBF
(33 bytes)
STR
FLG
CS
C/D
SCK
SI
(SIO)
Serial I/O control section
SO
(NC)
RDB
(7 bytes)
Frame data
control
section
RBF
(40 bytes)
DD
V
DD
Test circuit
TEST
Timing
generation
section
RESETAV
Remark The pin names in parentheses are used when two-wire serial I/O is selected.
APPENDIX A MAIN DIFFERENCES BETWEEN µPD72042A, µPD72042B, AND µPD6708 ......... 90
APPENDIX B IEBus PROTOCOL ANALYZER .................................................................................. 90
DATA SHEET S13990EJ2V0DS00
5
Page 6
1. PIN FUNCTIONS
1.1 PIN FUNCTIONS
µ
PD72042A, 72042B
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
Note
Pin
SCK
SI (SIO)
SO (NC)
IRQ
C/D
XI
XO
GND
BUS–
BUS+
AVDD
SEL
CS
Note
I/O
Input
Input (I/O)
Output
(none)
Output
Input
–
–
I/O
–
Input
Input
Function
Serial clock input pin for CPU interface
Serial data pin for CPU interface. (This pin
functions as an input pin when 3-wire serial
I/O mode is selected, or as an I/O pin when
2-wire serial I/O mode is selected.)
Serial data output pin for CPU interface. (The
pin functions as an output when 3-wire serial I/O
mode is selected. When 2-wire serial I/O mode
is selected, the pin is left open.)
Output pin for making an interrupt request to the
CPU. When a return code or a program crash is
detected, a high-level signal is output on this pin
for at least 8 µs.
Input pin used to select control mode or data
read/write mode. When this pin is driven high,
internal register address setting and data read/
write are enabled. When the mode changes, the
serial clock counter is reset.
Pins for connecting a system clock resonator. A
6- or 6.29-MHz crystal or ceramic resonator
must be used. The accuracy of the frequency is
as follows;
Mode 0, 1: ±1.5%
Ground pin
I/O pins connected to the IEBus bus
Main power supply pin for the IEBus bus driver/
receiver. When used, this pin must be tied to
VDD.
Input pin used to select either 3- or 2-wire serial
I/O mode. A high-level signal on this pin selects
3-wire serial I/O mode. A low-level signal on this
pin selects 2-wire serial I/O mode.
Chip select pin. When this pin is driven low, the
serial interface is enabled. When this pin is
driven high, the SO pin becomes high-impedance, and the serial clock counter is reset.
I/O format
CMOS input
CMOS input
(CMOS I/O)
CMOS output
(none)
CMOS output
CMOS input
–
–
–
–
CMOS input
CMOS input
Note
When reset
[for both hardware
and software]
Input
Input
High-impedance
Low level
Input
When reset by
hardware (Oscillation stopped)
XI = GND
XO = High level
When reset by
software (Oscillation continued)
–
High-impedance
–
Input
Input
Note Parentheses indicate the state corresponding to two-wire serial I/O mode.
6
DATA SHEET S13990EJ2V0DS00
Page 7
µ
PD72042A, 72042B
Pin No.
14
15
16
Pin
RESET
TEST
VDD
Input
Input
–
I/O
Function
Serial reset signal input pin. A low input causes
a reset. Whenever the power is turned on, a
low-level signal must be applied to this pin.
During normal operation, a high level is applied.
IC test pin. When used, this pin must be tied to
the VDD pin directly.
Main power supply input pin
I/O format
CMOS input
CMOS input
–
When reset
[for both hardware
and software]
Input
–
–
DATA SHEET S13990EJ2V0DS00
7
Page 8
µ
PD72042A, 72042B
2. IEBus OPERATION
2.1 OVERVIEW
µ
PD72042A and µPD72042B are CMOS LSI devices for the IEBus interface.
The
The IEBus is designed to enable the data transmission between devices in a small-scale digital data transmission
system.
µ
PD72042A and µPD72042B are connected to a microcomputer built into a device. A serial interface (SCK,
The
SO, and SI pins) is used for connection. The host controller (microcomputer) sets the commands and data needed
for data transmission via this serial interface.
µ
When data is transmitted, the host controller sets the data in the
Then, signals are output on the BUS pins (BUS+, BUS–). When data is received from the BUS pins, the host controller
can read it via the serial interface.
PD72042A or µPD72042B via the serial interface.
8
DATA SHEET S13990EJ2V0DS00
Page 9
2.2 IEBus COMMUNICATION PROTOCOL
The IEBus is outlined below.
• Communication method: Half duplex asynchronous communication
• Multi-master method
All units connected to the IEBus can transmit data to every other connected unit.
• Broadcast function (one-unit-to-multiple-units communication)
Group broadcast: Broadcast to a specific group of units
General broadcast : Broadcast to all units
• Two modes, each offering different transmission speeds, can be selected.
• Access control: Carrier Sense Multiple Access with Collision Detection (CSMA/CD)
Bus mastership priority is as follows:
1 Broadcast takes priority over ordinary communication (one-unit-to-one-unit communication).
2 Units having lower master addresses have a higher priority.
• Communication scale
Number of units: 50 max
Cable length: 150 m max (when twisted-pair cable is used <resistance 0.1 Ω/m or less>)
Load capacity: 8000 pF max <between BUS- and BUS+>, f
7100 pF max <between BUS- and BUS+>, f
X = 6 MHz
X = 6.29 MHz
Terminating resistance: 120 Ω
µ
Caution For the
PD72042A and µPD72042B, as a protective resistance, connect a 180-Ω resistor in series
with the BUS– and BUS+ pins.
DATA SHEET S13990EJ2V0DS00
9
Page 10
µ
PD72042A, 72042B
2.2.1 Bus Mastership Determination (Arbitration)
Before devices connected to the IEBus can control other devices, they must first acquire the bus. This operation
is called arbitration.
When more than one unit starts transmission at the same time, arbitration determines which of those units is allowed
to use the bus.
When arbitration results in only one device being granted bus mastership, the following bus mastership priority
conditions are used:
Remark Those devices that are defeated in arbitration can automatically enter retransmission mode. (For the
µ
PD72042A and µPD72042B, the number of retransmissions can be set by specifying a value between
0 and 7 in the MCR register.)
(1) Priority by communication type
Broadcast (one-unit-to-multiple-units communication) takes priority over ordinary communication (one-unit-toone-unit communication).
(2) Priority by master address
If the communication type is the same, the smallest master address value has the highest priority.
Example Each master address consists of 12 bits. A unit having master address 000H has the highest priority,
while a unit having master address FFFH has the lowest priority.
2.2.2 Communication Mode
The IEBus supports two communication modes, each having a different transmission speed. Table 2-1 lists the
transmission speed for each communication mode and the maximum number of bytes transmitted within one
communication frame.
Table 2-1 Transmission Speed and Maximum Number of Transmission
Bytes in Each Communication Mode
Note 1
(Kbps)
fX = 6.29 MHz
Note 2
Communication mode
016Approx. 3.9Approx. 4.1
132Approx. 17Approx. 18
Maximum number of transmission
bytes (bytes/frame)
Effective transmission speed
fX = 6 MHz
Note 2
Notes 1. Effective transmission speed at which the maximum transfer rate is achieved
µ
2. Oscillator frequencies for the
PD72042A and µPD72042B
Cautions 1. Before devices connected to the IEBus can perform communication, an appropriate commu-
nication mode must be set. Note that if a master unit and an associated unit (slave unit) have
different communication modes, they will not be able to communicate properly.
2. Communication cannot be performed properly between a unit operating at an oscillator
frequency of 6 MHz and another operating at 6.29 MHz, even when set to the same communication
mode. Units must use the same oscillator frequency to be able to communicate.
10
DATA SHEET S13990EJ2V0DS00
Page 11
µ
PD72042A, 72042B
2.2.3 Communication Address
With the IEBus, each device is assigned a unique 12-bit communication address. The communication address
consists of the following parts:
High-order 4 bits : Group number (number identifying the group to which a device belongs)
Low-order 8 bits: Unit number (number identifying a device in a group)
2.2.4 Broadcast
In ordinary communication, transmission and reception are performed between one master unit and one associated
slave unit. Broadcast can also be done between one master unit and more than one slave unit. In this case master
unit transmits data to an arbitrary number of slave units. In this case, the slave units do not return on acknowledge
signal to the master unit.
Whether the communication to be performed is broadcast or ordinary communication is determined by the setting
of the broadcast bit. (For details of the broadcast bit, see (1) 2 in Section 2.3.)
There are two types of broadcast.
(1) Group broadcast
Broadcast is performed to the devices in a particular group. These devices all have the same group number,
as indicated by the high-order 4 bits of each communication address.
(2) General broadcast
Broadcast is performed to all devices, regardless of their group numbers.
These two types of broadcast are distinguished by the slave address. (For details of the slave address, see (3)
in Section 2.3.)
2.3 TRANSMISSION PROTOCOL
Fig. 2-1 shows the IEBus transmission signal format.
Communication data is transmitted as a sequence of signals called a communication frame. The transmission
speed and the maximum amount of data that can be transmitted in one communication frame depend on the
communication mode.
DATA SHEET S13990EJ2V0DS00
11
Page 12
Fig. 2-1 Transmission Signal Format
µ
PD72042A, 72042B
(When f
X
= 6 MHz)
Field name
Number of bits
Transmission
time
Mode 0
Mode 1
Header
11
Broad-
Start
cast
bit
bit
Master
address field
121
Master
address
Slave
address field
121 1
PSlave
address
Approx. 7330
Approx. 2090
Control field
411
P A Control
bits
s
µ
s
µ
PA
Data-length
field
811
Data-
length
P AData
bits
P : Parity bit (1 bit)
A : Acknowledge bit (1 bit)
When A = 0: ACK
When A = 1: NAK
N : Number of data bytes
Remark For broadcast, the value of the acknowledge bit is ignored.
(1) Header
The header consists of a start bit and a broadcast bit. These are explained below.
Data field
811811
P AData
bits
Approx. 1590 × N
Approx. 410 × N
bits
µ
s
µ
PA
s
1 Start bit
The start bit is a signal used to notify the other units of the beginning of data transmission.
Before a unit starts data transmission, it outputs a low-level signal (start bit) for a specified duration, then
outputs the broadcast bit.
When the unit attempts to output the start bit, another unit may have already output the start bit. In such
a case, the unit does not output the start bit, and instead waits for the other unit to stop outputting the start
bit. Then, synchronized with the completion of start bit output by the other unit, the unit starts output of the
broadcast bit.
All units, except that unit which started the transmission, detect the start bit and become ready for reception.
2 Broadcast bit
The broadcast bit is used to distinguish between broadcast and ordinary communication.
If the broadcast bit is 0, broadcast is indicated. If the broadcast bit is 1, ordinary communication is indicated.
There are two types of broadcast: group broadcast and general broadcast. These types are distinguished
by the slave address. (For details of the slave address, see (3).)
For broadcast, more than one slave unit can exist as an associated communication station. Therefore, the
acknowledge bits for the master address field and subsequent fields are not returned.
When more than one unit starts sending a communication frame at the same time, broadcast takes
precedence over ordinary communication and wins arbitration.
12
DATA SHEET S13990EJ2V0DS00
Page 13
µ
PD72042A, 72042B
(2) Master address field
The master address field is used to transmit the local unit address (master address) to other units.
The master address field consists of master address bits and a parity bit.
A master address consists of 12 bits. It is output starting with the MSB.
When more than one unit starts transmitting the same broadcast bit value at the same time, arbitration
determination is performed by the master address field.
Each time a unit transmits one bit of the master address field, the unit compares its output data with the data
on the bus. If the comparison indicates that the master address output by the unit differs from the data on the
bus, the unit determines that it has lost an arbitration. The unit stops transmission, and readies itself for reception.
The IEBus is organized by wired AND. When arbitration is performed between units (arbitration masters), the
unit having the smallest master address value wins the arbitration.
After the 12-bit master address has been output, only one unit is finally determined as being the master unit,
such that that unit remains in the transmission state.
Note
Next, the master unit outputs a parity bit
proceeds to the slave address field.
Note Even parity is used. When the number of 1’s in the master address bits is odd, the parity bit is set to 1.
to post the master address to other units. Then, the master unit
(3) Slave address field
The slave address field is used to transmit the address (slave address) of a unit (slave unit) with which the master
unit wants to communicate.
The slave address field consists of slave address bits, a parity bit, and an acknowledge bit.
A slave address consists of 12 bits. It is output starting with the MSB. After a 12-bit slave address has been
transmitted, a parity bit is output to prevent the slave address from being received incorrectly. Then, the master
unit attempts to detect the acknowledge signal from a slave unit to confirm that the slave unit exists on the bus.
When the acknowledge signal is detected, the master unit outputs a control field. Note, however, that when
performing broadcast, the master unit outputs the control field without attempting to detect the acknowledge bit.
The slave unit outputs an acknowledge signal when the slave unit recognizes a match between the slave unit’s
address and the slave address transmitted by the master unit match, and that both the master address and slave
address have even parity. If the slave unit detects odd parity, it does not recognize the addresses as matching,
so does not output an acknowledge signal. In this case, the master unit is placed in the standby (monitor) state,
and communication terminates.
For broadcast, the slave address is used to distinguish between group broadcast or general broadcast, as follows:
When the slave address is FFFH: General broadcast
When the slave address is other than FFFH: Group broadcast
Remark For group broadcast, the number of a target group is indicated by the high-order 4 bits of the slave
address.
DATA SHEET S13990EJ2V0DS00
13
Page 14
µ
PD72042A, 72042B
(4) Control field
The control field indicates the type and direction of the next data field.
The control field consists of control bits, a parity bit, and an acknowledge bit.
The four control bits are output starting with the MSB.
Following the control bits, a parity bit is output. If even parity is detected, and the function requested by the master
unit can be performed by the slave unit, the slave unit outputs an acknowledge signal. Then, the slave unit
proceeds to the data-length field. If the slave unit cannot perform the processing requested by the master unit,
even when even parity is detected, or if odd parity is detected, the slave unit does not output an acknowledge
signal, and it enters the standby (monitor) state again.
After detecting the acknowledge signal, the master unit proceeds to the data-length field.
If an acknowledge signal is not detected, the master unit enters the standby state, terminating communication.
For broadcast, however, the master unit proceeds to the next data-length field without attempting to detect the
acknowledge signal.
Table 2-3 lists the meanings of the control bits.
(5) Data-length field
The data-length field specifies the communication data length, in bytes.
The data-length field consists of the data-length bits, a parity bit, and an acknowledge bit.
The eight data-length bits are output starting with the MSB. The data-length bits indicate the communication
data length, in bytes, as shown in Table 2-2.
Table 2-2 Values of the Data-Length Bits and Their Meanings
Data-length bit (hexadecimal)Transmission data length, in bytes
01H1
02H2
::
::
FFH255
00H256
Remark If the data length set in the data-length bits exceeds the maximum number of transmission bytes, the
latter varying with the communication mode, more than one frame is transmitted. In the second and
subsequent frames, the data-length bits indicate the remaining communication data length, in bytes.
The operation performed for this field differs depending on whether master transmission (when bit 3 of the control
bits is 1) or master reception (when bit 3 of the control bits is 0) is performed.
1 Master transmission
The data-length bits and parity bit are output by the master unit. When the slave unit detects even parity,
the slave unit outputs an acknowledge signal, then proceeds to the data field. For broadcast,
however, the slave unit does not output an acknowledge signal.
If the slave unit detects odd parity, the slave unit does not output an acknowledge signal, regarding the
received data-length bits as being incorrect. Then, the slave unit enters the standby (monitor) state again.
At this time, the master unit also enters the standby state again, and communication terminates.
14
DATA SHEET S13990EJ2V0DS00
Page 15
µ
PD72042A, 72042B
2 Master reception
The data-length bits and parity bit are output by the slave unit. When the master unit detects even parity,
the master unit outputs the acknowledge signal.
If the master unit detects odd parity, the master unit does not output an acknowledge signal, regarding the
received data-length bits as being incorrect. Then, the master unit enters the standby state again. At this
time, the slave unit also enters the standby state again, and communication terminates.
(6) Data field
The data field is used for data transmission and reception to and from a slave unit.
The master unit uses the data field to transmit data to the slave unit, or to receive data from the slave unit.
The data field consists of data bits, a parity bit, and an acknowledge bit.
The eight data bits are output, starting with the MSB.
After the data bits have been output, the parity bit and acknowledge bit are output from the master unit and slave
unit, respectively.
Broadcast is performed only when the master unit transmits data. At this time, any acknowledge signal is ignored.
The operations related to master transmission and master reception are explained below.
1 Master transmission
When the master unit performs a write to a slave unit, the master unit transmits the data bits and a parity
bit to the slave unit. The slave unit receives the data bits and parity bit, then outputs an acknowledge signal
if even parity is detected and the reception buffer is empty. If odd parity is detected, or if the reception buffer
is not empty, the slave unit rejects the corresponding data, and does not output an acknowledge signal.
If no acknowledge signal is received from the slave unit, the master unit transmits the same data
again. The master unit repeats this operation until it receives an acknowledge signal from the slave unit,
or until the data exceeds the maximum number of transmission bytes.
When even parity is detected, and an acknowledge signal is received from the slave unit, the master unit
transmits the subsequent data, if any, and provided the maximum number of transmission bytes is not
reached.
For broadcast, an acknowledge signal is not output by any slave unit. The master unit transfers data one
byte at a time.
2Master reception
When the master unit reads data from a slave unit, the master unit outputs a synchronization signal for each
bit as it is read.
The slave unit outputs data and a parity bit to the bus according to the synchronization signal output by the
master unit.
The master unit reads the data and parity bit output by the slave unit, and checks the parity.
If the master unit detects odd parity, or if the reception buffer is not empty, the master unit rejects the data,
and does not output an acknowledge signal. The master unit repeats the read operation for the same data
provided the maximum allowable number of transmission bytes per communication frame has not been
reached.
If the master unit confirms even parity, and the reception buffer is empty, the master unit accepts the data,
and returns an acknowledge signal to the slave unit. Then, the master unit reads the next data, provided
the maximum allowable number of transmission bytes per frame has not been reached.
DATA SHEET S13990EJ2V0DS00
15
Page 16
µ
PD72042A, 72042B
(7) Parity bit
A parity bit is used to check for errors in the transmission data.
A parity bit is added to the master address bits, slave address bits, control bits, data-length bits, and data bits.
Even parity is used. If the number of 1’s in the data is odd, the parity bit is set to 1. If the number of 1’s in the
data is even, the parity bit is set to 0.
(8) Acknowledge bit
In ordinary communication (one-unit-to-one-unit communication), an acknowledge bit is added in the following
positions to confirm that data has been received correctly:
• At the end of the slave address field
• At the end of the control field
• At the end of the data-length field
• At the end of the data field
The acknowledge bit is defined as follows:
• 0: Indicates that transmission data has been recognized. (ACK)
• 1: Indicates that no transmission data has been recognized. (NAK)
For broadcast, the acknowledge bit is ignored.
1 Acknowledge bit at the end of the slave address field
If any of the following is detected, the acknowledge bit at the end of the slave address field is set to NAK,
and transmission is stopped:
• The parity of the master address bits or slave address bits is incorrect.
• A timing error occurred (bit format error).
• No slave unit is found.
2 Acknowledge bit at the end of the control field
If any of the following is detected, the acknowledge bit at the end of the control field is set to NAK, and
transmission is stopped:
• The parity of the control bits is incorrect.
Note
• Although the slave reception buffer
• Although the slave transmission buffer
• For a locked unit, a unit other than the unit that specified the lock makes a request by using control bits
indicating 3H, 6H, 7H, AH, BH, EH, or FH.
• Although no lock has been set, control bits indicating lock address read (4H) are set.
• A timing error occurred.
• An undefined control bit setting has been made.
is not empty, bit 3 of the control bits is 1 (write operation).
Note
is empty, the control bits indicate data read (3H, 7H).
Note See (1) in Section 2.4.
16
DATA SHEET S13990EJ2V0DS00
Page 17
µ
PD72042A, 72042B
3 Acknowledge bit at the end of the data-length field
If any of the following is detected, the acknowledge bit at the end of the data-length field is set to NAK, and
transmission is stopped:
• The parity of the data-length bits is incorrect.
• A timing error occurred.
4 Acknowledge bit at the end of the data field
If any of the following is detected, the acknowledge bit at the end of the data field is set to NAK, and
transmission is stopped:
Note
• The parity of the data bits is incorrect
• A timing error occurred after the previous acknowledge bit.
• The reception buffer is full, such that no more data can be accepted
Note In this case, if the maximum allowable number of transmission bytes per frame has not yet been reached,
the transmitter retries transmission of the data field until the maximum number of transmission bytes is
reached.
.
Note
.
2.4 TRANSMISSION DATA (CONTENTS OF THE DATA FIELD)
The contents of the data field are indicated by the control bits.
DATA SHEET S13990EJ2V0DS00
17
Page 18
Table 2-3 Meanings of the Control Bits
µ
PD72042A, 72042B
Note 1
Bit 3
0H0000Read slave status (SSR)
1H0001Undefined
2H0010Undefined
3H0011Read data and locking
4H0100Read lock address (low-order 8 bits)
5H0101Read lock address (high-order 4 bits)
6H0110Read slave status (SSR) and unlocking
7H0111Read data
8H1000Undefined
9H1001Undefined
AH1010Write command and locking
BH1011Write data and locking
CH1100Undefined
DH1101Undefined
EH1110Write command
FH1111Write data
Bit 2Bit 1Bit 0 Function
Note 2
Notes 1. The transfer direction of the data-length bits of the subsequent data-length field and data in the data
field changes according to the value of bit 3 (MSB).
When bit 3 is 1: Transfer from the master unit to the slave unit
When bit 3 is 0: Transfer from the slave unit to the master unit
2. The values of control bits 3H, 6H, AH, and BH specify locking and unlocking. When an undefined value,
1H, 2H, 8H, 9H, CH, or DH, is transmitted, no acknowledge signal is returned.
Once a unit has been locked by a master unit, the locked unit rejects the control bits received from other than the
master unit that requested the lock, unless the value of the control bits is one of the values listed in Table 2-4. Then,
the unit does not output the acknowledge bit.
Table 2-4 Control Field Acceptable to a Locked Slave Unit
Bit 3Bit 2Bit 1Bit 0 Function
0H0000Read slave status
4H0100Read lock address (low-order 8 bits)
5H0101Read lock address (high-order 4 bits)
(1) Reading the slave status (SSR) (control bits: 0H, 6H)
A master unit can read the slave status (0H, 6H) to determine why the slave unit did not return the acknowledge
bit (ACK).
The slave status is determined from the result of the communication last performed by the slave unit.
All slave units can provide slave status information.
Table 2-5 lists the slave status meanings.
18
DATA SHEET S13990EJ2V0DS00
Page 19
Fig. 2-2 Slave Status (SSR) Bit Format
µ
PD72042A, 72042B
MSB
bit 7bit 6bit 5bit 4bit 3bit 2bit 1bit 0
Table 2-5 Slave Status Meanings
BitValueMeaning
Note 1
Bit 0
Note 2
Bit 1
Bit 20The unit is not locked.
Bit 30Fixed at 0
Note 3
Bit 4
Bit 50Fixed at 0
Bit 700Mode 0
Bit 601Mode 1
0The slave transmission buffer is empty.
1The slave transmission buffer is not empty.
0The slave reception buffer is empty.
1The slave reception buffer is not empty.
When data read (3H, 7H) is set, the data in the data buffer of the slave unit is read into the master unit.
When data write (BH, FH) or command write (AH, EH) is set, the data received by the slave unit is processed
according to the operation specifications for the slave unit.
Remarks 1. The user can select data and commands as necessary according to the system.
2. 3H, AH, and BH may cause locking, depending on the communication conditions and status.
DATA SHEET S13990EJ2V0DS00
19
Page 20
µ
PD72042A, 72042B
(3) Reading a lock address (control bits: 4H, 5H)
When a lock address read operation (4H, 5H) is specified, the address (12 bits) of the master unit that
issued the lock instruction is read in one-byte form, as shown below.
The lock function is used to enable the transfer a message using more than one communication frame.
When locked, a unit cannot receive data from other than the unit that requested the lock.
Locking and unlocking are performed as follows:
1 Locking
The master unit can lock the slave unit by specifying the lock with the corresponding control bits (3H, AH,
BH). In this case, when the transmission or reception of acknowledge bit 0 for the data-length field has been
completed, but the communication frame is then terminated before transmission or reception of as many data
bytes as are specified by the data-length bits is completed, the slave unit is locked. At this time, the bit
indicating the lock status (bit 2) in the slave status byte is set to 1.
2 Unlocking
The master unit can unlock a locked slave unit when the control bits specify locking (3H, AH, or BH) or
unlocking (6H). The slave unit is unlocked once as many data bytes as are specified by the data-length bits
have been transmitted or received within one communication frame. At this time, the bit indicating the lock
status (bit 2) in the slave status byte is reset to 0.
For broadcast, locking or unlocking is not performed.
Low-order 8 bits
UndefinedHigh-order 4 bits
Caution When a locked unit is to be unlocked by the unit itself, hardware reset or software reset must
be performed. (The lock status can be checked by referring to the contents of the LOR2 register.)
20
DATA SHEET S13990EJ2V0DS00
Page 21
2.5 BIT FORMAT
Fig. 2-4 illustrates the bits that constitute an IEBus communication frame.
Fig. 2-4 IEBus Bit Format (Concept)
Logic "1"
Logic "0"
µ
PD72042A, 72042B
Preparation
period
Logic 1: The potential difference between the bus lines (the BUS+ and BUS- pins) is 20 mV or less (low level).
Logic 0: The potential difference between the bus lines (the BUS+ and BUS- pins) is 120 mV or more (high level).
Synchronization
period
Data period
Preparation
period
Synchronization
period
Data period
Preparation period: First and subsequent low-level (logic 1) periods
Synchronization period: Next high-level (logic 0) period
Data period: Period in which a bit value is indicated (logic 1 = low level, logic 0 = high level)
The synchronization and data periods are almost equal in duration.
For the IEBus, synchronization is established for each bit. The specifications of the total time required for a bit
and the duration of each period allotted within the bit vary depending on the type of the transmission bits, and whether
the unit is a master or slave.
DATA SHEET S13990EJ2V0DS00
21
Page 22
µ
PD72042A, 72042B
3. MICROCOMPUTER INTERFACE
3.1 TRANSFER METHOD
Either of two microcomputer interface modes can be selected: three-wire serial I/O mode or two-wire serial I/O
mode.
Whether three-wire serial I/O mode or two-wire serial I/O mode is selected depends on the input level of the SEL
pin (pin 12). (See Section 3.3 for details.)
SEL ← 1: Three-wire serial I/O
SEL ← 0: Two-wire serial I/O
(1) Three-wire serial I/O (SEL ← 1)
Three wires are used to read and write data. The three wires are the serial clock input (SCK), serial data input
Note 1
(SI
(a) Read operation
), and serial data output (SO
Data is output to the SO pin upon detecting the falling edge of the SCK pin.
Note 2
).
(b) Write operation
Data is input via the SI pin upon detecting the rising edge of the SCK pin. At this time, 1 is output on the
SO pin.
(2) Two-wire serial I/O (SEL ← 0)
Two wires are used to read and write data. The two wires are the serial clock input (SCK) and serial data I/O
Note 1
(SIO
(a) Read operation
(b) Write operation
Notes 1. The SI pin for three-wire serial I/O mode is also used as the SIO pin for two-wire serial I/O mode.
).
The SIO pin is placed in the output state, and data is output upon detecting the falling edge of the SCK pin.
The SIO pin is placed in the input state, and data is input upon detecting the rising edge of the SCK pin.
2. The impedance of the SO pin for three-wire serial I/O mode goes high in two-wire serial I/O mode. So,
connect the SO pin to GND or V
DD.
22
DATA SHEET S13990EJ2V0DS00
Page 23
µ
Table 3-1 I/O States of the SIO (SI) and SO Pins
PD72042A, 72042B
RESETCSSELC/DSI (SIO)SO
Three-wire/two-wireOperating mode
0×××IHi-Z–Reset state
11×× IHi-Z–Chip nonselected state
1011IO*Three-wireControl mode
0Data write mode
OData read mode
01IHi-ZTwo-wireControl mode
0Data write mode
OData read mode
State
I: Input stateHi-Z : High-impedance state
O : Output state×: Don’t care
O* : State in which 1 is output
3.2 DATA TRANSFER FORMAT
3.2.1 Three-Wire Data Transfer (SEL = 1)
(1) Control mode
When the C/D input is set high, control mode is set to control data transfer. Data transfer control involves the
following processing.
1 Register address setting
2 Register read/write selection
µ
PD72042A (starting with MSB) (b) µPD72042B (starting with LSB)
(a)
C/D
SCK
SI
A3 A2 A1 A0
R
×××
/
W
C/D
SCK
SI
×××
R
/
W
A3A2A1A0
Remark After reset (RESET) cancellation, the state enabling writing to the register at address 0000B is set.
Caution In control mode, each data item is read every eighth clock pulse. (Data of less than eight clock
periods is ignored.)
DATA SHEET S13990EJ2V0DS00
23
Page 24
µ
PD72042A, 72042B
(2) Data read mode
When the C/D pin is set low after register read is selected in control mode, the data read mode is set. In data
read mode, the data in a read register is read on the SO pin upon detecting the falling edge of the SCK pin.
µ
PD72042A (starting with MSB)
(a)
C/D
SCK
SI
SO
State
Serial clock counter
reset pointer
A3 A2 A1 A0×××
“1”
Control mode
(selection of register read)
1
D7 D6 D5 D4 D3 D2 D1 D0
Data read mode
(b)µPD72042B (starting with LSB)
C/D
SCK
1
SI
SO
State
Serial clock counter
reset pointer
“1”
(selection of register read)
A0 A1 A2 A3×××
D0 D1 D2 D3 D4 D5 D6 D7
Control mode
Data read mode
Caution When the C/D pin is set high in data read mode, the serial clock counter is reset. Therefore, the
remaining bits of the byte cannot be read; at the next falling edge, read is performed starting from
the next byte in the case of RBF, or from the first bit for other registers.
24
DATA SHEET S13990EJ2V0DS00
Page 25
µ
PD72042A, 72042B
(3) Data write mode
When the C/D pin is set low after register write has been selected in control mode, data write mode is set. In
data write mode, data for a write register is applied to the SI pin at the rising edge of the SCK pin.
µ
PD72042A (starting with MSB)
(a)
C/D
SCK
SI
SO
State
Serial clock counter
reset pointer
A3 A2 A1 A0×××
“1”
Control mode
(selection of register write)
0
D7 D6 D5 D4 D3 D2 D1 D0
Data write mode
(b)µPD72042B (starting with LSB)
C/D
SCK
A0 A1 A2 A3×××
SI
SO
State
Serial clock counter
reset pointer
0
“1”
Control mode
(selection of register write)
D0 D1 D2 D3 D4 D5 D6 D7
Data write mode
Caution Register overwrite is started immediately after the eighth clock rising edge. All registers other
than TBF are overwritten on the eighth clock rising edge. (Data of less than eight clock periods
is ignored.)
DATA SHEET S13990EJ2V0DS00
25
Page 26
µ
PD72042A, 72042B
3.2.2 Two-Wire Data Transfer (SEL = 0)
(1) Control mode
When the C/D input is set high, control mode is set to control data transfer. Data transfer control involves the
following processing.
1 Register address setting
2 Register read/write selection
µ
PD72042A (starting with MSB)
(a)
C/D
SCK
R
SIO
A3A2A1A0
/
×××
W
(b) µPD72042B (starting with LSB)
C/D
SCK
R
SIO
×××A0A1A2A3
/
W
Remark After reset (RESET) cancellation, the state enabling writing to the register at address 0000B is set.
Caution In control mode, each data item is read every eighth clock pulse. (Data of less than eight clock
periods is ignored.)
26
DATA SHEET S13990EJ2V0DS00
Page 27
(2) Data read mode
(a)µPD72042A (starting with MSB)
C/D
SCK
µ
PD72042A, 72042B
Note
SIO
State
Serial clock counter
reset pointer
A3 A2 A1 A0×××
(selection of register read)
(b)µPD72042B (starting with LSB)
C/D
SCK
Note
SIO
State
Serial clock counter
reset pointer
(selection of register read)
Note SIO pin input state
SIO pin output state
1
Control mode
A0 A1 A2
1×××A3
Control mode
D7 D6 D5 D4 D3 D2 D1 D0
Data read mode
D0 D1 D2 D3 D4 D5 D6 D7
Data read mode
Cautions 1. When the C/D pin is set high in data read mode, the serial clock counter is reset. Therefore,
the remaining bits of the byte cannot be read; at the next falling edge, a read operation is
performed starting from the next byte in the case of RBF, or from the first bit for other registers.
2. The SIO pin is a CMOS I/O pin. So, be careful to avoid an output collision between the SIO
pin and the microcomputer. Further, a pull-up resistor is required when N-ch open-drain
output of the microcomputer is used. Note that if the last output level is low upon the
termination of read mode, current will flow constantly.
DATA SHEET S13990EJ2V0DS00
27
Page 28
(3) Data write mode
(a)µPD72042A (starting with MSB)
C/D
SCK
µ
PD72042A, 72042B
Note
SIO
State
Serial clock counter
reset pointer
A3 A2 A1 A0×××
(selection of register write)
(b)µPD72042B (starting with LSB)
C/D
SCK
Note
SIO
StateData write mode
Serial clock counter
reset pointer
(selection of register write)
Note SIO pin input state
0
Control mode
A0 A1 A2 A3×××
0
Control mode
D7 D6 D5 D4 D3 D2 D1 D0
Date write mode
D0 D1 D2 D3 D4 D5 D6 D7
Caution Register overwrite is started immediately after the eighth clock rising edge. All registers other
than TBF are overwritten at the eighth clock rising edge. (Data of less than eight clock periods
is ignored.)
28
DATA SHEET S13990EJ2V0DS00
Page 29
3.3 CONNECTION TO A MICROCOMPUTER
(1) Three-wire serial I/O
120 Ω
µ
PD72042A, 72042B
(2) Two-wire serial I/O
180 Ω
180 Ω
120 Ω
120 Ω
180 Ω
180 Ω
120 Ω
5 V
5 V
6 MHz
6 MHz
DD
V
AV
DD
TEST
BUS+
BUS–
XI
XO
GND
PD72042A
µ
PD72042B
µ
V
DD
AV
DD
TEST
BUS+
BUS–
XI
XO
GND
µ
µ
SEL
Note 1
CS
C/D
SCK
Note 2
IRQ
RESET
CS
IRQ
RESET
PD72042A
PD72042B
SI
SO
SEL
Note 1
C/D
SCK
SIO
SO
Note 2
5 V
Low
voltage
detection
circuit
5 V
Low
voltage
detection
circuit
Microcomputer
Output port
Output port
SCK
SO
SI
INT
75XL series
78K series
Microcomputer
Output port
Output port
SCK
Note 3
SIO
INT
75XL series
78K series
Notes 1. When only the µPD72042A or µPD72042B is to be controlled from a microcomputer via a serial I/O
interface, the CS pin must be tied low (by connecting it to GND).
2. When an interrupt is detected by polling (in FLG register read), IRQ may be left open. When high-volume
or high-speed data transfer is required, however, the system described above is recommended to ensure
reliable data transfer.
µ
3. Required when the microcomputer’s N-ch open-drain output is used. The SIO pin of the
PD72042A
and µPD72042B is a CMOS I/O pin.
DATA SHEET S13990EJ2V0DS00
29
Page 30
µ
PD72042A, 72042B
3.4 STANDBY MODE SETTING AND CANCELLATION
Standby mode can be set by setting STREQ of the CTR register to 1. The XI pin for oscillation is tied to GND,
and the impedance of the XO pin goes high.
In standby mode (with the STM flag of the FLG register set to 1), only the following registers can be accessed:
Standby mode can be cancelled by setting STREQ of the CTR register to 0.
Caution Do not read any data from internal registers via the serial I/O during the period from when a
µ
microcomputer sets the STREQ flag to 1 to when the
standby mode. This period is one-communication frame at maximum.
3.5 RESET MODE SETTING AND CANCELLATION
For hardware reset, the registers are initialized and standby mode is set. (During this period, oscillation is stopped.)
For software reset, the registers are initialized, and operation is started.
PD72042A or µPD72042B enters the
30
DATA SHEET S13990EJ2V0DS00
Page 31
µ
PD72042A, 72042B
4. REGISTERS
A microcomputer controls IEBus communication by reading from and writing to the internal registers of the
µ
PD72042A or µPD72042B.
Registers are classified into write registers and read registers. The total size of the write registers is 40 bytes;
the transmission buffer uses 33 of the 40 bytes. The total size of the read registers is 49 bytes; the reception buffer
uses 40 of the 49 bytes.
Note Writable and readable periods of the registers of the µPD72042A and µPD72042B
A: Arbitrary
B: After system reset cancellation
C: While CEX of the FLG register (address 0001) is set to 0
D: While MARQ of the FLG register (address 0001) is set to 0
E: After SLRC of the RCR register (address 1000) is set to 1100 (broadcast reception error)
F: While TFL of the STR register (address 0000) is set to 0
G: While REP of the STR register (address 0000) is set to 0
H: When CEX of the FLG register (address 0001) is set to 0 after LOCK of the CMR register (address 0001)
is set to 1
32
DATA SHEET S13990EJ2V0DS00
Page 33
µ
PD72042A, 72042B
Cautions 1. In standby mode (with STM of the FLG register set to 1), the user can only write to the CTR
register (including standby mode cancellation) and read from the FLG register.
2. Never access a free address.
3. Slave status (SSR) can be read into RBF by setting the control bits to 0H or 6H from the master
unit.
CTRAddress: 0000B (0H)
Read/write: Write
Control registerWhen reset : ×××00××1B
CTR is a one-byte write register used to control µPD72042A and µPD72042B operations.
b7
—
b6
—
b5
—
b4b3b0
REENSRST—STREQ
b2b1
—CTR
[REEN]
When REEN is set to 1, the SLRE flag of the FLG register is immediately set to 1 to enable both slave and broadcast
reception.
[SRST]
µ
When SRST is set to 1, the
PD72042A or µPD72042B is immediately reset. (Note, however, that STREQ is set
to a written value.)
[STREQ]
1: Requests standby mode.
0: Exits from standby mode.
• Standby mode setting and cancellation
µ
PD72042A or µPD72042B is requested to enter the standby mode by setting the STREQ flag to 1 from the
The
µ
microcomputer. The
PD72042A or µPD72042B enters standby mode when the standby mode input enabled state
(carrier sense state) is set. In this case, the impedance of the BUS+ and BUS– pins goes high (logic 1), and the
STM flag of the FLG register is set to 1. In standby mode, oscillation is stopped, and all operations are stopped
while preserving the internal data, thus minimizing power consumption.
When, in standby mode, the STREQ flag is set to 0 from the microcomputer, standby mode is cancelled
after the period (about 20 ms at f
X = 6 MHz) needed for oscillation to stabilize; the halted operations are resumed
from the point at which standby mode was set. At this time, the STM flag of the FLG register changes to 0.
In standby mode, only writing to the CTR register (for standby mode cancellation) and reading from the FLG register
can be performed from the microcomputer.
Cautions 1. When the SRST flag and STREQ flag are simultaneously set to 1, standby mode is set after
software reset. (This state is the same as that set by hardware reset.) Note, however, that
when the SRST flag is set to 1 in standby mode, a software reset is performed, but this is not
reflected in the FLG register.
2. Do not read any data from internal registers via the serial I/O during the period from when a
µ
microcomputer sets the STREQ flag to 1 to when the
PD72042A or µPD72042B enters the
standby mode. This period is one-communication frame at maximum.
DATA SHEET S13990EJ2V0DS00
33
Page 34
µ
PD72042A, 72042B
CMRAddress: 0001B (1H)
Read/write: Write
Command registerWhen reset : 00000000B
CMR is a one-byte write register used to set a command for communication control, transmission/reception buffer
control, or optional function setting.
µ
When data is set in CMR from the microcomputer, CEX of the FLG register is set to 1. When the
µ
PD72042B processes the data set in CMR, CEX is set to 0.
or
After the microcomputer checks that CEX of the FLG register is set to 0, new data can be set in CMR.
The following describes the data that is set in CMR.
(1) When bit 7 (MSB) of CMR is 0
PD72042A
b7
0b6LOCK
b5
b4b3b0
BUFC
COMCCMR
[LOCK]: Lock state setting command
1 : The value representing the lock state (0001 for locked or 0000 for not-locked) and lock address are output
to LOR1 and LOR2. Note, however, that when 0000 (not-locked) is output, any lock address value is ignored.
0 : The contents of LOR1 and LOR2 remain as is.
[BUFC]: Transmission/reception buffer control command
00 : The transmission and reception buffers remain as is.
01 : The transmission buffer (TBF) is cleared.
10 : The reception buffer (RBF) is cleared.
11 : The data of the previous (latest) communication frame to be stored in the reception buffer (RBF) is
Note 1
cleared
.
[COMC]: Communication control command
0000: Communication operation remains as is.
0001: The locked state is cancelled.
Note 2
1000: Master communication is requested
1001: Master communication is requested, with the previous master transmission state held
.
Note 3
.
1010: Master communication is aborted.
1011: Slave data transmission is requested
1100: Slave data transmission is requested, with the previous slave data transmission state held
Note 4
.
Note 5
1101: Slave data transmission is aborted.
1111: Slave reception and broadcast reception are disabled.
.
Notes 1. If the microcomputer has already read the data for the previous (latest) communication frame from RBF,
or optional function setting in CMR is selected and MFC = 0, clear RBF with BUFC = 10.
34
DATA SHEET S13990EJ2V0DS00
Page 35
µ
PD72042A, 72042B
Notes 2. When the MSB of the control bits set in MCR is 1 (for master transmission), set the number of bytes
of transmission data, and at least one byte of transmission data in TBF before command setting.
3. When the MSB of the control bits set in MCR is 1 (for master transmission), set at least one byte of
transmission data before command setting. This operation is not required if all transmission data has
already been set in TBF.
4. Set the number of bytes of transmission data, and at least one byte of transmission data in TBF before
command setting.
5. Set at least one byte of transmission data in TBF before command setting. This operation is not required
if all transmission data has already been set in TBF.
(2) When bit 7 (MSB) of CMR is 1
An optional function is set.
b7
b6
1
0
b5
b4b3b0
0
00MFCDERC
b2b1
IRSCMR
[MFC]: Selection of one frame/multiple frames
1 : Data for multiple frames is stored in RBF.
0 : Data for only one frame is stored in RBF.
[DERC]: Broadcast reception selection
1 : The issue of return code 1100 (broadcast reception error) for SLRC of the RCR register is enabled.
0 : The issue of return code 1100 (broadcast reception error) for SLRC of the RCR register is disabled.
[IRS]: Interrupt generation condition selection
0 : An interrupt is requested when the data of the RCR register changes.
1 : An interrupt is requested when the data of the RCR register changes to other than the following:
MARC = 0000B (start of master transmission)
MARC = 0100B (start of master reception)
SLRC = 0000B (start of slave data transmission)
SLRC = 0100B (start of slave reception)
SLRC = 1000B (start of broadcast reception)
Caution Set an optional function in initialization processing after reset cancellation for the
µ
PD72042B. Until an optional function has been set, the µPD72042A and µPD72042B will not
Slave address registerWhen reset : Undefined (the pre-
vious data is held)
The SAR1 and SAR2 registers are used to set the address of a remote station (slave address) in master
communication.
Set SAR1 and SAR2 while the value of MARQ of the FLG register is 0 (while master communication is not
requested).
b7
Slave address (low-order 4 bits)
b7b0
Slave address (high-order 8 bits)
b4b3b0
0000
SAR1
SAR2
DATA SHEET S13990EJ2V0DS00
37
Page 38
µ
PD72042A, 72042B
MCRAddress: 0110B (6H)
Read/write: Write
Master communication registerWhen reset : Undefined (the pre-
vious data is held)
The MCR register is used to set a master communication condition.
Set MCR while the value of MARQ of the FLG register is 0 (while master communication is not requested).
b7
Broadcast bitb6Number of arbitrations
b4b3b0
Control bitsMCR
[Broadcast bit]
This bit is used to select broadcast or separate communication.
Bit 7 = 0: Broadcast
Bit 7 = 1: Separate communication
[Number of arbitrations] (Number of retries)
This field is used to set the maximum number of retry operations to be performed if arbitration is lost in master
µ
communication. The
PD72042A and µPD72042B automatically retry communication as many times as the number
set in this field.
b6b5b4Number of retries
0000
0011
0102
0113
1004
1015
1106
1117
38
DATA SHEET S13990EJ2V0DS00
Page 39
[Control bits]
This control field is used to set the control bits (four bits).
• Contents of control bits
µ
PD72042A, 72042B
Note 1
Bit 3
0H0000Slave status (SSR) read
1H0001Undefined
2H0010Undefined
3H0011Data read and lock
4H0100Lock address read (low-order 8 bits)
5H0101Lock address read (high-order 4 bits)
6H0110Slave status (SSR) read and unlock
7H0111Data read
8H1000Undefined
9H1001Undefined
AH1010Command write and lock
BH1011Data write and lock
CH1100Undefined
DH1101Undefined
EH1110Command write
FH1111Data write
Bit 2Bit 1Bit 0 Function
Note 2
Notes 1. The value of bit 3 (MSB) determines the transfer direction of the subsequent data-length field data and
data field data.
When bit 3 is set to 1: Data is transferred from the master unit to a slave unit.
When bit 3 is set to 0: Data is transferred from a slave unit to the master unit.
2. 3H, 6H, AH, and BH are control bits used for lock setting and cancellation.
When an undefined value of 1H, 2H, 8H, 9H, CH, or DH is sent, no acknowledgement is returned.
DATA SHEET S13990EJ2V0DS00
39
Page 40
µ
PD72042A, 72042B
TBFAddress: 1110B (EH)
Read/write: Write
Transmission bufferWhen reset : Empty
TBF is a 33-byte FIFO buffer used to hold the number of bytes of transmission data and transmission data for master
transmission and slave data transmission.
TBF can be written from the microcomputer when the TFL flag of the STR register is set to 0 (indicating that TBF
is not full).
In master transmission and slave data transmission, the following format is used to load data into TBF from the
microcomputer.
TBF
Byte 1Number of bytes of transmission data
Byte 2First byte of transmission data
Byte 3Second byte of transmission data
…
Byte 33
…
…
[Byte 1]: Number of bytes of transmission data
Between 1 and 256 bytes can be set.
Number of bytes ofData set in byte 1 of TBF
transmission data
101H
202H
……
255FFH
25600H
……
[Bytes 2 and up]: Transmission data
As much transmission data as is set in byte 1 is set in byte 2 and subsequent bytes.
40
DATA SHEET S13990EJ2V0DS00
Page 41
µ
PD72042A, 72042B
STRAddress: 0000B (0H)
Read/write: Read
Status registerWhen reset : 0101××××B
STR is a one-byte read register used to indicate the states of TBF and RBF.
b7
TFLb6TEPb5RFL
[TFL]
1 : TBF is full.
0 : TBF is not full. The microcomputer can load data into TBF.
[TEP]
1 : TBF is empty. The microcomputer can load initial data into TBF.
0 : TBF is not empty.
[RFL]
1 : RBF is full.
0 : RBF is not full.
[REP]
1 : RBF is empty.
0 : RBF is not empty. The microcomputer can read data from RBF.
b4b3b0
REP———
b2b1
—STR
DATA SHEET S13990EJ2V0DS00
41
Page 42
µ
PD72042A, 72042B
FLGAddress: 0001B (1H)
Read/write: Read
Flag registerWhen reset : 00000010B
FLG is a one-byte read register used to indicate statuses such as the communication state, command execution
state, and interrupt state.
b7
—b6MARQb5STRQ
[MARQ]
1 : A request for communication as the master unit is being made.
0 : No request for communication as the master unit is being made. Data can be written to the SAR1, SAR2, and
MCR registers.
The MARQ flag is set and reset as described below.
• Set: When the CEX flag of the FLG register is set to 0 after 1000 or 1001 is set in COMC of the CMR register
• Reset : When master communication is terminated
[STRQ]
1 : A request for slave unit data transmission is being made.
0 : No request for slave unit data transmission is being made.
The STRQ flag is set and reset as described below.
• Set: When the CEX flag of the FLG register is set to 0 after 1011 or 1100 is set in COMC of the CMR register
• Reset : When slave data transmission is terminated
[SLRE]
1 : Slave reception or broadcast is allowed.
0 : Slave reception and broadcast are not allowed.
b4b3b0
SLRECEXSTMIRQ
b2b1
RAWFLG
The SLRE flag is set and reset as described below.
• Set: When REEN of the CTR register is set to 1
• Reset : When slave reception or broadcast reception is terminated normally or suspended, or when CEX of
the FLG register is set to 0 after 1111 is set in COMC of the CMR register
When SLRE = 0, bit 1 of the slave status is set to 1 regardless of the state of RBF; communication frame reception
based on the AH, BH, EH, and FH control bits, received from the master station, is not performed.
42
DATA SHEET S13990EJ2V0DS00
Page 43
µ
PD72042A, 72042B
[CEX]
1 : A command is currently being executed.
0 : Execution of a command has terminated. A command code can be set in CMR.
The CEX flag is set and reset as described below.
• Set: When a command code is set in CMR
µ
• Reset : When
[RAW]
µ
1 : The
0 : The µPD72042A or µPD72042B is not running away.
The RAW flag is used to indicate a microprogram crash in the
watchdog timer.
When the RAW flag is set to 1, a request to interrupt the microcomputer is issued. An interrupt pulse signal is
output on the IRQ pin, and the IRQ flag of the FLG register is set. At this time. The microcomputer must reset the
µ
PD72042A or µPD72042B by driving the RESET pin of the µPD72042A or µPD72042B low or by setting the SRST
flag of the CTR register to 1.
PD72042A or µPD72042B is running away.
PD72042A or µPD72042B command processing is terminated
µ
PD72042A or µPD72042B, as detected by a
[STM]
1 : Standby mode is set.
0 : Standby mode is not set.
[IRQ]
1 : An interrupt request was made.
0 : No interrupt request is made.
Note
The IRQ flag is set when a return code including the code in the RCR register is changed
flag changes from 0 to 1 (crash). When the FLG register is read with the IRQ flag set to 1, the IRQ flag is reset.
For details of the return codes, see the description of the RCR register.
Note IRQ flag setting depends on the IRS value of the CMR register.
The RDR1 and RDR2 registers are used to hold the number of bytes of reception data stored in RBF for each frame
received during master, slave, or broadcast reception.
b7
Number of bytes of master reception data
b7b0
Number of bytes of slave or broadcast reception data
b0
RDR1
RDR2
[RDR1]
RDR1 indicates the number of bytes of data set in RBF by a communication frame during master reception. One
of the following values is set in RDR1:
• When master communication is requested (COMC = 1000 or 1001): RDR1 = 0
• When master reception is started (MARC = 0100): RDR1 = 3
• Each time one byte of data is received: RDR1 is incremented by 1.
[RDR2]
RDR2 indicates the number of bytes of data set in RBF by a communication frame in slave reception or broadcast
reception. One of the following values is set in RDR2:
• When slave reception is started (SLRC = 0100): RDR2 = 3
• When broadcast reception is started (SLRC = 1000): RDR2 = 3
• Each time one byte of data is received: RDR2 is incremented by 1.
• Example of RDR2 setting
Data-
length bits PADataPADataPA
+ 3345
Communication
frame
RDR2
Control bits PA
F00101001100210
Note
N
Note N: Number of bytes of data received with the previous communication frame
The LOR1 and LOR2 registers are used to hold a lock state.
LOR1 and LOR2 set a lock state and lock address after the lock state setting command is set in the CMR register
(LOCK = 1), then executed.
b7b0
Lock address (low-order 8 bits)
LOR1
b7
Lock state
[Lock state]
0000: Not locked
0001: Locked
Remark When 0000 (not locked) is set in the lock state bits, any lock address value is ignored.
The DAR1 and DAR2 registers are used to hold a broadcast address (master address) involved when a broadcast
reception error occurs.
DAR1 and DAR2 are updated each time a broadcast reception error occurs (SLRC of the RCR register is set to
1100). So, ensure that when a broadcast reception error occurs, the contents of DAR1 and DAR2 are read by the
microcomputer within the time indicated below.
b7
Broadcast address (low-order 4 bits)
b7b0
Broadcast address (high-order 8 bits)
• Maximum allowable DAR1 and DAR2 read time (t: At fX = 6 MHz):
µ
Approx. 5420
Approx. 1490 µs (mode 1)
Cautions 1. If the microcomputer cannot read the data in DAR1 and DAR2 within the times indicated above,
2. A broadcast address is stored in DAR1 and DAR2 when DERC (broadcast reception selection)
s (mode 0)
DAR1 and DAR2 may be updated by the occurrence of another broadcast reception error, and
the subsequently updated broadcast address may be read.
of the CMR register is set to 1.
b4b3b0
—DAR1
DAR2
t
IRQ
46
DATA SHEET S13990EJ2V0DS00
Page 47
µ
PD72042A, 72042B
RCRAddress: 1000B (8H)
Read/write: Read
Return code registerWhen reset : 11111111B
RCR is a one-byte read register used to indicate the IEBus communication status (return code).
RCR consists of two return codes: MARC and SLRC. MARC indicates the communication status in master
transmission or master reception. SLRC indicates the communication status in slave data transmission, slave
reception, or broadcast reception. When the contents of RCR change, an interrupt request is sent to the
microcomputer according to the setting of the IRS flag of the CMR register.
The MARC and SLRC flags are set independently, such that the microcomputer can simultaneously read the master
communication status and slave communication status.
b7
MARC
Caution When IRQ is set as a result of a program crash, the previous value of RCR is preserved.
[MARC]
MARC represents a return code issued during master transmission or master reception.
(a) Master transmission
Master transmission is performed when the microcomputer performs the setting explained below.
• Master transmission setting
1 In the low-order 4 bits of the MCR register, control bits (1010, 1011, 1110, or 1111) are set for master-
to-slave data transfer.
2 In COMC of the CMR register, a command (1000 or 1001) for requesting master communication is set.
Table 4-2 lists the MARC return codes for master transmission.
b4b3b0
SLRCRCR
DATA SHEET S13990EJ2V0DS00
47
Page 48
Table 4-2 MARC Return Codes for Master Transmission
MARCDescription
00001. Meaning: Master transmission is started.
2. Occurrence condition: This return code is issued when the master address field in a communication
frame has been transmitted, and the unit has won the arbitration to become the master unit.
00011. Meaning: Master transmission data is not available.
2. Occurrence condition: This return code is issued if the next transmission data is not set in TBF during
master transmission.
3. Microcomputer processing: If data consisting of one or more bytes is not set in TBF within the time
below, transmission may be terminated prior to its completion.
• Transmission data setting time:Approx. 1570 µs (mode 0)
Approx. 390 µs (mode 1)
00101. Meaning: Master transmission was terminated normally.
2. Occurrence condition: This return code is issued when as much data as the amount specified in the
data-length field has been transmitted normally. In this case, the MARQ flag of the FLG register changes
from 1 to 0.
µ
PD72042A, 72042B
00111. Meaning: Master transmission was aborted.
2. Occurrence condition: This return code is issued in any of the following cases. In each case, the MARQ
flag of the FLG register changes from 1 to 0.
• When the unit has lost the arbitration to become the master unit.
• When a transmission is stopped because the NAK is returned from the slave unit at the end of the slave
address field, the control field, or the data-length field of a communication frame (excluding the broadcast).
• When a communication is terminated prior to the transmission of as much data as the amount specified
in the data-length field of a communication frame.
(b) Master reception
Master reception is performed when the microcomputer performs the setting below.
• Master reception setting
1 In the low-order 4 bits of the MCR register, control bits (0000, 0011, 0100, 0101, 0110, or 0111) are set
for slave-to-master data transfer.
2 In COMC of the CMR register, a command (1000 or 1001) for requesting master communication is set.
Table 4-3 indicates the MARC return codes for master reception.
48
DATA SHEET S13990EJ2V0DS00
Page 49
Table 4-3 MARC Return Codes for Master Communication
MARCDescription
01001. Meaning: Master reception has started.
2. Occurrence condition:
1 The unit has won the arbitration to become the master unit, and a communication frame up to the
data-length field was transferred successfully.
2 When the control field is received, RBF becomes ready for reception
After the data-length field, 0000 is set in MARC, and three-byte data consisting of a slave address,
control bits, and data-length bits is set in RBF. If RBF becomes full when this three-byte data is set,
0001 is set in MARC.
3. Microcomputer processing: Three-byte data consisting of a slave address, control bits, and datalength bits can be read from RBF.
01011. Meaning: The master reception buffer is full.
2. Occurrence condition: This return code is issued when RBF becomes full during data reception as the
master unit, and reception data cannot be set in RBF.
3. Microcomputer processing: If data consisting of one or more bytes is not read from RBF within the
time below, the one-byte data cannot be received, and the µPD72042A or µPD72042B returns an NAK.
• Reception data read time:Approx. 1570 µs (mode 0)
Approx. 390 µs (mode 1)
01101. Meaning: Master reception was terminated normally.
2. Occurrence condition: This return code is issued when as much data as the amount specified in the
data-length field has been received normally in a communication frame. In this case, the MARQ flag of
the FLG register changes from 1 to 0.
3. Microcomputer processing: Reception data can be read from RBF, and the number of bytes of
master reception data can be read from RDR1.
01111. Meaning: Master reception was aborted.
2. Occurrence condition: This return code is issued in any of the following cases. In each case, the
MARQ flag of the FLG register changes from 1 to 0.
• When the unit has lost the arbitration to become the master unit.
• When a transmission is stopped because the NAK is returned from the slave unit at the end of the
slave address field or the control field of a communication frame or because the NAK is sent to the
slave unit at the end of the data-length field of a communication frame (excluding the broadcast).
• When a communication is terminated prior to the reception of as much data as the amount specified
in the data-length field of a communication frame.
3. Microcomputer processing: Reception data can be read from RBF, and the number of bytes of
master reception data can be read from RDR1.
µ
PD72042A, 72042B
Note
.
Note See Note of Table 4-9.
DATA SHEET S13990EJ2V0DS00
49
Page 50
[MARC occurrence interval]
(a) When master transmission is performed
µ
PD72042A, 72042B
Return codes for master
transmission and master reception
Ta
0010
0011
0110
0111
Tb
Return codes for master transmission
0001
0010
0011
0000
0011
Tc
Td
Te
Tf
Tf
Te
Return codes for master
transmission and master reception
0001
Ta
0010
Tb
0011
Tg
0000
0011
0111
0100
Table 4-4 Minimum Return Code Occurrence Interval for Master Transmission (t: At fX = 6 MHz)
SLRC indicates the communication status for slave data transmission, slave reception, or broadcast reception.
(a) Slave data transmission
Slave data transmission is performed when the microcomputer makes the setting described below.
• Slave data transmission setting
In COMC of the CMR register, a command (1011 or 1100) for requesting slave data transmission is set
from the microcomputer.
Table 4-6 SLRC Return Codes in Slave Data Transmission
SLRCDescription
00001. Meaning: Slave data transmission has been started.
2. Occurrence condition: This return code is issued when the control bits (0011 or 0111) requesting data
transmission are received from the master unit.
00011. Meaning: Slave transmission data is not available.
2. Occurrence condition: This return code is issued when the next transmission data is not set in TBF
during slave data transmission.
3. Microcomputer processing: If data consisting of one or more bytes is not set in TBF within the time
below, transmission may be terminated prior to its completion.
• Transmission data setting time: Approx. 1570 µs (mode 0)
Approx. 390 µs (mode 1)
00101. Meaning: Slave data transmission was terminated normally.
2. Occurrence condition: This return code is issued when as much data as the amount specified in the
data-length field has been transmitted normally. In this case, the STRQ flag of the FLG register
changes from 1 to 0.
00111. Meaning: Slave data transmission was aborted.
2. Occurrence condition: This return code is issued when communication is terminated prior to the
transmission of as much data as the amount specified in the data-length field in a communication frame.
In this case, the STRQ flag of the FLG register changes from 1 to 0.
52
DATA SHEET S13990EJ2V0DS00
Page 53
(b) Slave reception
Slave reception is performed when the broadcast bit is set to 1, and a communication frame with the local
station address specified in the slave address field is received.
Table 4-7 indicates the SLRC return codes for slave reception.
Table 4-7 SLRC Return Codes for Slave Reception
SLRCDescription
01001. Meaning: Slave reception is started.
2. Occurrence condition:
1 A separate communication frame up to the data-length field was received normally from the
master unit.
2 Once the control field has been received, RBF is ready for reception
After the data-length field, 0100 is set in SLRC, and three-byte data consisting of a master address,
control bits, and data-length bits is set in RBF.
3. Microcomputer processing: Three-byte data consisting of a master address, control bits, and datalength bits can be read from RBF.
µ
PD72042A, 72042B
Note
.
01011. Meaning: The slave reception buffer is full.
2. Occurrence condition: This return code is issued when RBF becomes full during data reception as a
slave unit, and reception data cannot be set in RBF.
3. Microcomputer processing: If data consisting of one or more bytes is not read from RBF within the
period indicated below, the one-byte data cannot be received, and the µPD72042A or µPD72042B
returns an NAK.
• Reception data read time: Approx. 1570 µs (mode 0)
Approx. 390 µs (mode 1)
01101. Meaning: Slave reception was terminated normally.
2. Occurrence condition: This return code is issued when as much data as the amount specified in the
data-length field has been received normally in a communication frame. In this case, the SLRE flag of
the FLG register changes from 1 to 0.
3. Microcomputer processing: Reception data can be read from RBF, and the number of bytes of slave
reception data can be read from RDR2.
01111. Meaning: Slave reception was aborted.
2. Occurrence condition: This return code is issued when reception is terminated prior to the reception
of as much data as the amount specified in the data-length field of a communication frame. In this
case, the SLRE flag of the FLG register changes from 1 to 0.
3. Microcomputer processing: Reception data can be read from RBF, and the number of bytes of slave
reception data can be read from RDR2.
Note See Note of Table 4-9.
DATA SHEET S13990EJ2V0DS00
53
Page 54
(c) Broadcast reception
Broadcast reception is performed when the broadcast bit is set to 0, and a communication frame with FFH
(general broadcast) or the local station group address specified in the slave address field is received.
Table 4-8 indicates the SLRC return codes for broadcast reception.
Table 4-8 SLRC Return Codes for Broadcast Reception
SLRCDescription
10001. Meaning: Broadcast reception is started.
2. Occurrence condition:
1 A broadcast frame up to the data-length field was received from the master unit normally.
2 Once the control field has been received, RBF is ready for reception
After the data-length field, 1000 is set in SLRC, and three-byte data consisting of a master address,
control bits, and data-length bits is set in RBF.
3. Microcomputer processing: Three-byte data consisting of a master address, control bits, and datalength bits can be read from RBF.
10011. Meaning: The broadcast reception buffer is full.
2. Occurrence condition: This return code is issued when RBF becomes full during data reception as a
slave unit, preventing subsequent reception data from being set in RBF.
µ
PD72042A, 72042B
Note
.
3. Microcomputer processing: If data consisting of one or more bytes is not read from RBF within the
time below, broadcast reception is aborted.
• Reception data read time: Approx. 1570 µs (mode 0)
Approx. 390 µs (mode 1)
10101. Meaning: Broadcast reception was terminated normally.
2. Occurrence condition: This return code is issued when as much data as the amount specified in the
data-length field has been received normally in a communication frame. In this case, the SLRE flag of
the FLG register changes from 1 to 0.
3. Microcomputer processing: Reception data can be read from RBF, and the number of bytes of
broadcast reception data can be read from RDR2.
10111. Meaning: Broadcast reception was aborted.
2. Occurrence condition: This return code is issued when reception is terminated prior to the reception
of as much data as the amount specified in the data-length field in a communication frame. In this case,
the SLRE flag of the FLG register changes from 1 to 0.
3. Microcomputer processing: Reception data can be read from RBF, and the number of bytes of
broadcast reception data can be read from RDR2.
Note See Note of Table 4-9.
54
DATA SHEET S13990EJ2V0DS00
Page 55
µ
PD72042A, 72042B
Table 4-9 indicates the SLRC return code issued in broadcast reception when an optional function is set in the
CMR register with DERC = 1.
Table 4-9 SLRC Return Code in Broadcast Reception When the Optional Function Is Set (DERC = 1)
SLRCDescription
11001. Meaning: Broadcast reception error
2. Occurrence condition: This return code is issued if RBF is not ready for reception
control field is received. In this case, the master address in the communication frame is set as a
broadcast address in DAR2 and DAR1.
3. Microcomputer processing: A broadcast address can be read from DAR1 and DAR2. However, the
data of DAR1 and DAR2 is updated each time a broadcast reception error occurs. So, ensure that data
is read from DAR1 and DAR2 within the interval indicated below.
• Read time: Approx. 5420 µs (mode 0)
Approx. 1490 µs (mode 1)
Note
when the
Note RBF is ready for reception according to the optional function setting in CMR, as described below.
(i) When MFC = 0
The SLRE flag of the FLG register is 1 (slave reception and broadcast reception only); and
RBF is empty.
(ii) When MFC = 1
The SLRE flag of the FLG register is 1 (slave reception and broadcast reception only); and
RBF has at least 4 bytes of free space.
When RBF is ready for reception, bit 1 of slave status transmitted from the master unit with control bits 0000 or
0110 is set to 0.
DATA SHEET S13990EJ2V0DS00
55
Page 56
[SLRC occurrence interval]
(a) When slave data transmission is performed
µ
PD72042A, 72042B
Return codes for broadcast
reception, slave data
transmission, and slave reception
0010
0011
0110
0111
1010
1011
1100
Ta
0000
Return codes for slave data transmission
Tb
Tb
Td
Tb
Tc
0001
0010
Td
0011
Return codes for broadcast
reception, slave data
transmission, and slave reception
0001
0010
0011
Ta
Te
Ta
0000
0100
1000
1100
Table 4-10 Minimum Return Code Occurrence Interval for Slave Data Transmission (t: At fX = 6 MHz)
RBF is a 40-byte FIFO buffer used to hold a transmitter address, control bits, data-length bits, and reception data
for master reception, slave reception, or broadcast reception.
RBF can be read by the microcomputer when the REP flag of the STR register is 0 (indicating that RBF is not empty).
When an optional function is set in the CMR register with MFC = 1, multiple communication frames can be held
in RBF until RBF becomes full.
In master reception, slave reception, and broadcast reception, the format below is used to transfer data from RBF
The number of bytes of reception data is set in the RDR1 or RDR2 register, as described below.
RDR1: Number of bytes of reception data in master reception
RDR2: Number of bytes of reception data in slave reception or broadcast reception
The number of bytes of reception data indicates the number of bytes of data received normally within a
communication frame. This means that the number of bytes of reception data will match the length set in the datalength field of a communication frame only when the data has been received normally.
60
DATA SHEET S13990EJ2V0DS00
Page 61
µ
PD72042A, 72042B
5. EXAMPLE TIMINGS FOR COMMUNICATION
This chapter provides examples of the timings at which the contents of internal registers change during
communication. The following seven examples are given:
(1) Master transmission timing example 1
Timing at which a return code is generated upon the start of master transmission and at the normal termination
of transmission
(2) Master transmission timing example 2
Timing at which a return code is generated upon the start of master transmission, transmission data empty, and
the suspension of transmission
(3) Slave data transmission timing example
Timing at which a return code is generated upon the start of slave data transmission and the normal termination
of transmission
(4) Master reception timing example
Timing at which a return code is generated upon the start of master reception and the normal termination of
reception
(5) Slave reception timing example 1
Timing at which a return code is generated upon the start of slave reception and the normal termination of
reception
(6) Slave reception timing example 2
Timing at which a return code is generated upon the start of slave reception, reception buffer full, and the normal
termination of reception
(7) Broadcast reception timing example
Timing at which a return code is generated upon the occurrence of an error during broadcast reception
DATA SHEET S13990EJ2V0DS00
61
Page 62
62
(1) Master transmission timing example 1
Communication frame
CMR
COMC
CEX
DATA SHEET S13990EJ2V0DS00
FLG
RCR
MARQ
STRQ
SLRE
MARC
SLRC
IRQ pin
Minimum time
X
(when f
Control fieldData-length fieldData fieldHeader
1000
"0"
0100
(Slave reception started)
= 6 MHz)
0110 (Slave reception terminated)
Approx. 2430 s (mode 0)
Approx. 740 s (mode 1)
Master address
field
µ
µ
Slave address
field
Control fieldData field
0000 (Master transmission started)0010
Data-length
field
(Master transmission terminated normally)
µ
PD72042A, 72042B
Page 63
(2) Master transmission timing example 2
Communication frame
CMR
COMC
CEX
MARQ
DATA SHEET S13990EJ2V0DS00
FLG
RCR
STR
TBF
STRQ
SLRE
MARC
SLRC
TEP
IRQ pin
Master
address bits
"0"
"0"
"1"
Minimum time
X
= 6 MHz)
(when f
Slave
PPAPAPAPAPAPA
address bits
0000 (Master transmission started)
Control bits
Data-length
bits
Data 1Data 31Data 32
(Master transmission data empty)
Approx. 1570 s (mode 0)
Approx. 390 s (mode 1)
(Master transmission suspended)
µ
µ
00110001
µ
PD72042A, 72042B
63
Page 64
64
(3) Slave data transmission timing example
Communication frame
CMR
COMC
CEX
MARQ
DATA SHEET S13990EJ2V0DS00
FLG
STRQ
SLRE
MARC
RCR
SLRC
IRQ pin
Minimum time
(when f
X
= 6 MHz)
Control field Data-length fieldData fieldHeader
1011
"0"
0100
(Slave reception started)
Approx. 5420 s (mode 0)
Approx. 1490 s (mode 1)
Master address
field
0110 (Slave reception terminated)0000
µ
µ
Slave address
field
Control
field
Data-length
(Slave data transmission terminated normally)
field
(Slave data transmission started)
Data field
0010
µ
PD72042A, 72042B
Page 65
(4) Master reception timing example
Communication frame
CMR
DATA SHEET S13990EJ2V0DS00
RCR
RDR1
FLG
COMC
CEX
MARQ
STRQ
SLRE
MARC
SLRC
IRQ pin
Control fieldData-length fieldData fieldHeader
1000
"0"
01000110 (Slave reception terminated)
(Slave reception started)
Minimum time
(when f
X
= 6 MHz)
Master address
field
Approx. 7150 s (mode 0)
Approx. 1920 s (mode 1)
Slave address
field
µ
µ
Control
field
Data-
length field
Note
(Master reception terminated normally)
Data field
(Master reception started)
01000110
34N + 3
N + 2
65
Note Data-length bit: N
µ
PD72042A, 72042B
Page 66
66
(5) Slave reception timing example 1
Communication frame
CTR
DATA SHEET S13990EJ2V0DS00
FLG
RCR
RDR2
REEN
CEX
MARQ
STRQ
SLRE
MARC
SLRC
IRQ pin
Minimum time
X = 6 MHz)
(when f
Control fieldData-length fieldData field
Separate frame (data-length bits: N1)Broadcast frame (data-length bits: N2)
This chapter provides an example of the processing flow for controlling the µPD72042A or µPD72042B from the
microcomputer. The main parts of this example processing flow are the following two routines:
• Main routine
Performs processing based on the communication flags set by the interrupt routine.
• Interrupt routine
µ
Sets the communication flags by reading the statuses of the
interrupt request.
PD72042A or µPD72042B upon the issue of an
DATA SHEET S13990EJ2V0DS00
69
Page 70
µ
PD72042A, 72042B
6.1 COMMUNICATION FLAGS
Table 6-1 lists the communication flags used in the main and interrupt routines, excluding those flags assigned
µ
to the registers of the
PD72042A or µPD72042B.
Table 6-1 Communication Flags
NameDescription
RAWFProgram crash detection flag (1: Detected, 0: Not detected)
TRRQTransmission processing request flag (1: Requested, 0: Not requested)
TRCFTransmission status (TRC stored)
INumber of bytes in transmission data set in TBF
Note
RERQ
RECF
SIZE
Note
PW
Note
PR
Note
Note
Reception processing request flag (1: Requested, 0: Not requested)
Reception status (REC stored)
Number of bytes in reception data which can be read from RBF (RDR1/RDR2 stored)
Write pointer for RERQ, RECF, and SIZE
Read pointer for RERQ, RECF, and SIZE
JNumber of bytes in reception data which has actually been read from RBF
MCRQMaster communication processing request flag (1: Requested, 0: Not requested)
SDRQSlave data transmission processing request flag (1: Requested, 0: Not requested)
CORQCommand processing request flag (1: Requested, 0: Not requested)
MTRQFMaster transmission request flag (1: Requested, 0: Not requested)
MRRQFMaster reception request flag (1: Requested, 0: Not requested)
STRQFSlave data transmission request flag (1: Requested, 0: Not requested)
SLREFSlave broadcast reception enable flag (1: Enabled, 0: Disabled)
Note RERQ, RECF, and SIZE are stored in a buffer pair pointed to by PW and PR.
• Buffer configuration
PointerRERQRECFSIZE
0
1
............
Remark Buffers pointed to by the write pointer (PW): RERQW, RECFW, and SIZEW
Buffers pointed to by the read pointer (PR): RERQR, RECFR, and SIZER
70
DATA SHEET S13990EJ2V0DS00
Page 71
6.2 MAIN ROUTINE
Fig. 6-1 shows the processing flow of the main routine.
Fig. 6-1 Processing Flow of Main Routine
Start
µ
PD72042A orµPD72042B
initial setting routine
µ
PD72042A, 72042B
; See Section 6.4.1.
Communication flag
initialization routine
RAWF?
0
TRRQ?
0
RERQ?
0
Note
MCRQ
SDRQ
0
Note
0
?
?
; See Section 6.4.2.
1
1
TRRQ 0
1
RERQ 0
1
MCRQ 0
1
SDRQ 0
; Initialize if program crash is detected.
Transmission
processing routine
Reception
processing routine
Master communication processing
routine
Slave data transmission processing
routine
; See Section 6.4.6.
; See Section 6.4.7.
; See Section 6.4.4.
; See Section 6.4.5.
Note
CORQ
Application processing routine
?
0
1
CORQ 0
Command
processing routine
; See Section 6.4.3.
Note Communication flags MCRQ, SDRQ, and CORQ are set to 1 by the application processing routine.
DATA SHEET S13990EJ2V0DS00
71
Page 72
µ
PD72042A, 72042B
6.3 INTERRUPT ROUTINE
The interrupt routine performs the required processing when an interrupt request is issued from the µPD72042A
or µPD72042B.
µ
The interrupt routine disables the interrupts received from the
PD72042A or µPD72042B, reads the statuses (FLG
and RCR registers) of the µPD72042A or µPD72042B, and sets the communication flags to be used by the main
routine.
µ
To enable the handling of an interrupt request which may occur while the interrupts from the
µ
PD72042B are disabled, do not clear the interrupt flags such that such a request can be detected upon the completion
PD72042A or
of the interrupt routine processing (see Fig. 6-2).
Fig. 6-2 Operation when an Interrupt Occurs during Execution of Interrupt Routine
Microcompute
routine
IRQ
RCR
Main routine
(interrupts enabled)
Interrupt routine
(interrupts disabled)
Interrupt routine
(interrupts disabled)
72
DATA SHEET S13990EJ2V0DS00
Page 73
RAWF← 1
Fig. 6-3 Flow of Interrupt Routine
Start
Disable interrupts from
µ
PD72042A orµPD72042B
Read FLG
1
RAW?
0
Read RCR
; Program crash?
µ
PD72042A, 72042B
TRCF ← MARC
TRRQ ← 1
TRCF ← SLRC
TRRQ ← 1
N
RERQ
SIZE
RECF
N
RERQW ← 1
SIZE
RECF
Is return
code in MARC
enabled?
Y
MARC?
010×
W
← 1
W
← RDR1
W
← MARC
Is return
code in SLRC
enabled?
Y
SLRC?
010×,
100×
W
← RDR2
W
← SLRC
; See Note 1.
011×00××
; See Note 2.
011×, 101×00××
W
← 1
RERQ
SIZE
W
← RDR1
RECF
W
← MARC
Increment PW
RERQ
W
← 0
SIZE
W
← 0
RERQ
W
← 1
SIZE
W
← RDR2
RECF
W
← SLRC
REEN ← 1
Increment PW
RERQW ← 0
SIZE
W
← 0
; Classify MARC.
; Initialize RERQ.
; Initialize SIZE.
; Classify SLRC.
; Initialize RERQ.
; Initialize SIZE.
Enable interrupts from
µ
PD72042A orµPD72042B
RETI
End
Notes 1. The return code in MARC is enabled when any of conditions, 1 , 2 , or 3 , below, is satisfied:
1 MARC has been changed
Note 3
.
2 MTRQF = 1 and MARQ = 0
3 MRRQF = 1 and MARQ = 0
2. The return code in SLRC is enabled when any of conditions, 1 , 2 , or 3 , below, is satisfied:
Note 3
1 SLRC has been changed
.
2 STRQF = 1 and STRQ = 0
3 SLREF = 1 and SLRE = 0
3. When MARC is 0001 or 0101, the same value may be generated consecutively, such that MARC is set
to 1111 to enable the detection of a change in MARC the next time it is generated. When SLRC is 0001,
0101, or 1001, it is again set to 1111 for the same reason.
DATA SHEET S13990EJ2V0DS00
73
Page 74
µ
PD72042A, 72042B
6.4 PROCESSING ROUTINES
This section describes the processing routines called from the main routine.
µ
6.4.1
PD72042A or µPD72042B Initial Setting Routine
This routine is executed when the µPD72042A or µPD72042B is first started or upon the detection of a program
crash (RAW = 1).
µ
Fig. 6-4 shows the flow of the
PD72042A or µPD72042B initial setting routine.
Fig. 6-4 µPD72042A or µPD72042B Initial Setting Routine
Start
µ
Reset PD72042A
or PD72042B
µ
Note
UAR1 ← Local station address (four low-order bits)
UAR2 ← Local station address (eight high-order bits)
Condition code
CMR ← 100000 b1 b0
End
; Set local address and condition code.
; Set condition code.
; Set optional functions.
Note There are two methods of performing reset, as follows:
1 Set the RESET pin to low.
2 Set SRST in CTR to 1.
µ
Type 1 reset causes the
PD72042A or µPD72042B to enter standby mode, thus requiring the subsequent
release of standby mode.
Caution To enable normal IEBus communication, always perform the above initial setting.
6.4.2 Communication Flag Initialization Routine
This routine initializes the communication flags listed in Table 6-1, as follows:
This routine is executed when CORQ has been set by the application processing routine.
The command processing routine sets a command code, in the CMR register, to set the lock state, control
transmission/reception buffers, control communication, and set optional functions.
The commands for master communication and slave data transmission request are described in Sections 6.4.4
and 6.4.5.
Fig. 6-5 shows the flow of the command processing routine.
Fig. 6-5 Command Processing Routine
Start
Read FLG
1
CMR ← Command code
CEX?
0
End
;
Waiting for termination
of previous command?
6.4.4 Master Communication Processing Routine
This routine is executed when MCRQ has been set by the application processing routine.
The master communication processing routine consists of the following three processing routines:
• Master transmission processing routine 1
This routine is used to transmit data, as the master unit, starting from the first data in TBF.
• Master transmission processing routine 2
This routine is used to start master transmission from the point at which the previous master transmission was
suspended.
• Master reception processing routine
This routine is used to receive data, as the master unit, from a slave unit.
DATA SHEET S13990EJ2V0DS00
75
Page 76
(1) Master transmission processing routine 1
Fig. 6-6 shows the flow of master transmission processing routine 1.
Fig. 6-6 Flow of Master Transmission Processing Routine 1
Start
SAR1 ← Slave address (four low-order bits)
SAR2 ← Slave address (eight high-order bits)
MCR ← Broadcast bits, number of arbitrations,
and control bits (The MSB is 1.)
Read STR
µ
PD72042A, 72042B
TEP?
0
Read FLG
1
1
TBF ← Number of bytes
in transmission data
CEX?
0
CMR ← 00010000
Read FLG
CEX?
0
| ← 1
I >
Number of bytes
in tranmission data
1
;
Waiting for termination of previous command?
Set clear command for transmission buffer.
;
; Waiting for termination of processing of
transmission buffer clear command?
;
Initialize |.
Y
Setting tranmission data in TBF completed?
;
76
N
Read STR
TFL?
0
|← | + 1
TBF ← Transmission data (I-th byte)
1
DATA SHEET S13990EJ2V0DS00
1
CMR← 00001000
Read FLG
CEX?
0
MTRQF← 1
End
;
Set master communication
request command.
; Waiting for termination of
processing of master communication
request command?
Page 77
(2) Master transmission processing routine 2
Fig. 6-7 shows the flow of master transmission processing routine 2.
Fig. 6-7 Flow of Master Transmission Processing Routine 2
Start
µ
PD72042A, 72042B
I >
Number of bytes
in tranmission data
N
Read STR
TFL?
0
| ← | + 1
TBF ← Transmission data (I-th byte)
Read FLG
1
CEX?
0
CMR ← 00001001
Y
1
; Waiting for terminaton of previous command?
; Set master communication continuation command.
Setting tranmission data
in TBF completed?
Read FLG
1
CEX?
0
MTRQF ← 1
End
DATA SHEET S13990EJ2V0DS00
; ; Waiting for termination of processing of master
communication continuation command?
77
Page 78
(3) Master reception processing routine
Fig. 6-8 shows the flow of the master reception processing routine.
Fig. 6-8 Flow of Master Reception Processing Routine
Start
µ
PD72042A, 72042B
SAR1 ← Slave address (four low-order bits)
SAR2 ← Slave address (eight high-order bits)
MCR ← Broadcast bits, number of arbitrations,
and control bits (The MSB is 0.)
Read FLG
1
1
CEX?
0
CMR ← 00001000
Read FLG
CEX?
0
MRRQF ← 1
End
; Waiting for termination of previous command?
; Set master communication request command.
Waiting for termination of processing of
;
master communication request command?
;
Set data only when changing
SAR1, SAR2, or MCR.
78
DATA SHEET S13990EJ2V0DS00
Page 79
µ
PD72042A, 72042B
6.4.5 Slave Data Transmission Processing Routine
This routine is executed when SDRQ has been set by the application processing routine.
The slave data transmission processing routine consists of the following two processing routines:
• Slave data transmission processing routine 1
This routine is used to transmit data, starting from the first data in TBF, when requested from the master unit.
• Slave data transmission processing routine 2
This routine is used to start slave data transmission from the point at which the previous slave data transmission
was suspended.
(1) Slave data transmission processing routine 1
Fig. 6-9 shows the flow of slave data transmission processing routine 1.
DATA SHEET S13990EJ2V0DS00
79
Page 80
µ
PD72042A, 72042B
Fig. 6-9 Flow of Slave Data Transmission Processing Routine 1
Start
Read STR
TEP?
0
Read FLG
1
1
TBF ← Number of bytes in transmission data
CEX?
0
CMR ← 00010000
Read FLG
CEX?
0
| ← 1
1
; Waiting for termination of previous command?
; Set clear command for transmission buffer.
; Waiting for termination of processing of
transmission buffer clear command?
; Initialize I.
I > Number of bytes in
tranmission data
N
Read STR
TFL?
0
| ← | + 1
TBF ← Transmission data (I-th byte)
1
Y
CMR ← 00001011
1
STRQF ← 1
; Setting of tranmission data in TBF
completed?
; Set slave data transmission
request command.
Read FLG
CEX?
0
End
80
DATA SHEET S13990EJ2V0DS00
Page 81
(2) Slave data transmission processing routine 2
Fig. 6-10 shows the flow of slave data transmission processing routine 2.
Fig. 6-10 Flow of Slave Data Transmission Processing Routine 2
Start
µ
PD72042A, 72042B
I > Number of bytes in
tranmission data
N
Read STR
TFL?
0
| ← | + 1
TBF ← Transmission data (I-th byte)
Read FLG
1
CEX?
0
CMR ← 00001100
1
Y
; Waiting for termination of previous command?
; Set slave data transmission continuation command.
Setting of tranmission data in
;
TBF completed?
Read FLG
1
CEX?
0
STRQF ← 1
0
End
DATA SHEET S13990EJ2V0DS00
;
Waiting for termination of processing of
slave data transmission continuation command?
81
Page 82
µ
PD72042A, 72042B
6.4.6 Transmission Processing Routine
This routine is executed when TRRQ has been set by the interrupt routine during the execution of master
transmission processing routine 1 (see 6.4.4 (1)), master transmission processing routine 2 (see 6.4.4 (2)), or the
slave data transmission processing routine (see 6.4.5).
Fig. 6-11 shows the flow of the transmission processing routine.
Fig. 6-11 Flow of Transmission Processing Routine
Start
TRCF?
00
I > Number of bytes
in tranmission data
N
Read STR
TFL?
0
| ← | + 1
TBF ← Transmission data (I-th byte)
10 or 11
1
; Transmission terminated
normally or suspended?
Y
TRRQ ← 0
MTRQF (STRQF) ← 0
End 2
Note 2
End 1
Note 1
Notes 1. Indicates that transmission of the communication frame has ended (terminated normally or suspended).
2. Indicates that setting of the transmission data has been completed with the current TBF.
82
DATA SHEET S13990EJ2V0DS00
Page 83
6.4.7 Reception Processing Routine
This routine is executed when RERQ has been set by the interrupt routine.
Fig. 6-12 shows the flow of the reception processing routine.
Fig. 6-12 Flow of Reception Processing Routine
Start
µ
PD72042A, 72042B
R?
J>SIZE
N
Read RBF
J← J + 1
Y
RECF
End 2
R?
××10 or ××11
××00
Increment PR
Note 2
; Reception terminated
normally or suspended?
J← 1
Note 1
End 1
; Initialize J.
Notes 1. Indicates that reception of the communication frame has ended (terminated normally or suspended).
2. Indicates that reading of the reception data has been completed with the current RBF.
DATA SHEET S13990EJ2V0DS00
83
Page 84
µ
PD72042A, 72042B
7. ELECTRICAL CHARACTERISTICS
ABSOLUTE MAXIMUM RATINGS (TA = 25 °C)
ParameterSymbolConditionsRated valueUnit
Supply voltageVDD, AVDD| VDD – AVDD | < 0.5 V–0.5 to +7.0V
Input voltage for logic sectionVI–0.5 to VDD + 0.3V
Output voltage for logic sectionVO–0.5 to VDD + 0.3V
Bus input voltageVBI–0.5 to +6.0V
Bus output voltageVBO–0.5 to +6.0V
Operating ambient temperatureTA–40 to +85°C
Storage temperatureTSTG–65 to +150°C
Caution Absolute maximum ratings are rated values beyond which physical damage may be caused to
the unit; if any of the parameters in the table above exceeds its rated value, even momentarily,
the performance and/or reliability of the product may deteriorate. Therefore, never exceed the
product’s rated values.
fC = 1 MHz
Excluding the BUS+ and BUSpins.
0 V for pins others than the
measured pins.
µ
A
µ
A
µ
A
µ
A
µ
A
84
DATA SHEET S13990EJ2V0DS00
Page 85
µ
PD72042A, 72042B
AC CHARACTERISTICS (TA = –40 to +85 °C, VDD = 5 V ±10 %)
ParameterSymbolConditionsMin.Typ.Max.Unit
System clockfX = 6 MHz5.916.006.09MHz
fX = 6.29 MHz6.206.296.38MHz
SCK cycle timetKCY0.8
SCK high-level widthtKH0.4
SCK low-level widthtKL0.4
SI (SIO)
SI (SIO)
SO (SIO)
Note 1
setup timetSIKReferred to SCK↑100ns
Note 1
hold timetKSIReferred to SCK↑400ns
Note 2
output delaytKSOReferred to SCK↓300ns
µ
s
µ
s
µ
s
CS, C/D setup timetSAReferred to SCK↓50ns
CS, C/D hold timetHAReferred to SCK↑400ns
IRQ output high-level width811
RESET low-level width6
µ
s
µ
s
SERIAL TRANSFER TIMING
t
CS, C/D
SA
t
KL
t
KCY
t
HA
t
KH
SCK
Note 1
SI (SIO)
SO (SIO)
Note 2
Notes 1. For 3-wire serial I/O: SI
For 2-wire serial I/O: SIO
2. For 3-wire serial I/O: SO
For 2-wire serial I/O: SIO
t
KSO
t
t
SIK
Input data
Output data
KSI
DATA SHEET S13990EJ2V0DS00
85
Page 86
Oscillator circuit (External system clock)
µ
PD72042A, 72042B
X1XO
GND
C1C2
Caution When using system clock oscillator, wire the portion enclosed in broken lines in the figure as
follows to avoid adverse influences on the wiring capacitance:
• Keep the wiring length as short as possible.
• Do not cross the wiring over the other signal lines.
• Do not route the wiring in the vicinity of lines through which a high fluctuating current flows.
• Always keep the ground point of the capacitor of the oscillator circuit at the same potential
as GND.
• Do not connect the power source pattern through which a high current flows.
• Do not extract signals from the oscillator.
IEBus DRIVER/RECEIVER CHARACTERISTICS (T
ParameterSymbolConditionsMin.Typ.Max.Unit
Output high voltageIONRL = 60 Ω±5 %, R = 180 Ω±5 %2.736.22mA
A = –40 to +85 °C, VDD = 5 V ±10 %)
Output low voltageIOL1.0
Common mode output voltageVOCOMFor high and low levelsX – 1/2VDD X +V
X = 1/2VDD0.250.25
Input high voltageVIH120mV
Input low voltageVIL20.0mV
Input hysteresis voltageVIHYS25mV
Common mode input voltage, high VIHCOM1.00VDDV
– 1.0
Common mode input voltage, lowVILCOM0VDDV
Driver output resistanceROBetween BUS+ and BUS–100kΩ
Driver output capacitanceCO25pF
Receiver input capacitanceCI25pF
Between BUS+ and BUS–, between BUS+
and GND, and between BUS– and GND
Please use the capacitor on the bus line under the capacitance shown in the table below.
System clock (fX)Maximum capacitance between
the Bus+ pin and Bus– pin
6 MHz8000 pF
6.29 MHz7100 pF
Therefore, the total load capacitance CT between the Bus+ pin and Bus– pin is as follows.
N
Σ
1
g + CWCW: Wiring capacitance
C
2
C
T =
Cautions 1. The circuit constants in the above figure are applied when each unit connected to the IEBus
µ
line uses the
PD72042A and µPD72042B.
2. The load capacitor connected to the bus line should be located closer to the IEBus than to
the protective resistor, as shown in the figure above.
3. Do not insert inductive parts into the bus line.
DATA SHEET S13990EJ2V0DS00
87
Page 88
8. PACKAGE DRAWING
16 PIN PLASTIC SOP (375 mil)
169
18
A
F
G
µ
PD72042A, 72042B
detail of lead end
P
H
I
J
S
C
D
M
M
B
E
NOTE
Each lead centerline is located within 0.12 mm of
its true position (T.P.) at maximum material condition.
L
S
N
K
ITEM MILLIMETERS
A10.2±0.26
B0.805 MAX.
C1.27 (T.P.)
D0.42
E0.125±0.075
F2.9 MAX.
G2.50±0.2
H10.3±0.3
I7.2±0.2
J1.6±0.2
K0.17
L0.8±0.2
M0.12
N0.10
P3°
+0.08
−0.07
+0.08
−0.07
+7°
−3°
P16GT-50-375B-1
88
DATA SHEET S13990EJ2V0DS00
Page 89
µ
PD72042A, 72042B
9. RECOMMENDED SOLDERING CONDITIONS
When soldering this product, it is highly recommended to observe the conditions as shown below. If other soldering
processes are used, or if the soldering is performed under different conditions, please make sure to consult with our
sales offices.
For more details, refer to our document “SEMICONDUCTOR DEVICE MOUNTING TECHNOLOGY MANUAL”
(C10535E).
Surface mount devices
µ
PD72042AGT: 16-pin plastic SOP (375 mil)
µ
PD72042BGT: 16-pin plastic SOP (375 mil)
ProcessConditionsSymbol
Infrared ray reflowPeak temperature: 235 °C or below (Package surface temperature),IR35-00-2
Reflow time: 30 seconds or less (at 210 °C or higher),
Maximum number of reflow processes: 2 times.
VPSPeak temperature: 215 °C or below (Package surface temperature),VP15-00-2
Reflow time: 40 seconds or less (at 200 °C or higher),
Maximum number of reflow processes: 2 times.
Wave solderingSolder temperature: 260 °C or below, Flow time: 10 seconds or less,WS60-00-1
Maximum number of flow processes: 1 time,
Pre-heating temperature: 120 °C or below (Package surface temperature).
Partial heating methodPin temperature: 300 °C or below,—
Heat time: 3 seconds or less (Per each side of the device).
Caution Apply only one kind of soldering condition to a device, except for “partial heating method”, or
the device will be damaged by heat stress.
DATA SHEET S13990EJ2V0DS00
89
Page 90
µ
PD72042A, 72042B
APPENDIX A MAIN DIFFERENCES BETWEEN µPD72042A, µPD72042B, AND µPD6708
Item
Product
Oscillation frequency (fX)6 MHz12 MHz
Operating voltage (VDD)5 V ±10 %
Operating ambient temperature (TA)–40 to +85 °C
IEBusCommunication modeMode 0, 1Mode 0, 1, 2
Note: Strong electric field, when exposed to a MOS device, can cause destruction
of the gate oxide and ultimately degrade the device operation. Steps must
be taken to stop generation of static electricity as much as possible, and
quickly dissipate it once, when it has occurred. Environmental control must
be adequate. When it is dry, humidifier should be used. It is recommended
to avoid using insulators that easily build static electricity. Semiconductor
devices must be stored and transported in an anti-static container, static
shielding bag or conductive material. All test and measurement tools
including work bench and floor should be grounded. The operator should
be grounded using wrist strap. Semiconductor devices must not be touched
with bare hands. Similar precautions need to be taken for PW boards with
semiconductor devices on it.
2HANDLING OF UNUSED INPUT PINS FOR CMOS
Note: No connection for CMOS device inputs can be cause of malfunction. If no
connection is provided to the input pins, it is possible that an internal input
level may be generated due to noise, etc., hence causing malfunction. CMOS
device behave differently than Bipolar or NMOS devices. Input levels of
CMOS devices must be fixed high or low by using a pull-up or pull-down
circuitry. Each unused pin should be connected to VDD or GND with a
resistor, if it is considered to have a possibility of being an output pin. All
handling related to the unused pins must be judged device by device and
related specifications governing the devices.
3STATUS BEFORE INITIALIZATION OF MOS DEVICES
Note: Power-on does not necessarily define initial status of MOS device. Produc-
tion process of MOS does not define the initial operation status of the device.
Immediately after the power source is turned ON, the devices with reset
function have not yet been initialized. Hence, power-on does not guarantee
out-pin levels, I/O settings or contents of registers. Device is not initialized
until the reset signal is received. Reset operation must be executed immediately after power-on for devices having reset function.
DATA SHEET S13990EJ2V0DS00
91
Page 92
µ
PD72042A, 72042B
[MEMO]
IEBus and Inter Equipment are trademarks of NEC Corporation.
The application circuits and their parameters are for reference only and are not intended for use in actual design-ins.
No part of this document may be copied or reproduced in any form or by any means without the prior written
consent of NEC Corporation. NEC Corporation assumes no responsibility for any errors which may appear in
this document.
NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellectual property
rights of third parties by or arising from use of a device described herein or any other liability arising from use
of such device. No license, either express, implied or otherwise, is granted under any patents, copyrights or other
intellectual property rights of NEC Corporation or others.
While NEC Corporation has been making continuous effort to enhance the reliability of its semiconductor devices,
the possibility of defects cannot be eliminated entirely. To minimize risks of damage or injury to persons or
property arising from a defect in an NEC semiconductor device, customers must incorporate sufficient safety
measures in its design, such as redundancy, fire-containment, and anti-failure features.
NEC devices are classified into the following three quality grades:
"Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based on a
customer designated "quality assurance program" for a specific application. The recommended applications of
a device depend on its quality grade, as indicated below. Customers must check the quality grade of each device
before using it in a particular application.
Standard: Computers, office equipment, communications equipment, test and measurement equipment,
audio and visual equipment, home electronic appliances, machine tools, personal electronic
equipment and industrial robots
Special:Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster
systems, anti-crime systems, safety equipment and medical equipment (not specifically designed
for life support)
Specific: Aircrafts, aerospace equipment, submersible repeaters, nuclear reactor control systems, life
support systems or medical equipment for life support, etc.
The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books.
If customers intend to use NEC devices for applications other than those specified for Standard quality grade,
they should contact an NEC sales representative in advance.