Datasheet UGN3055U Datasheet (Allegro)

Page 1
3055
MULTIPLEXED TWO-WIRE HALL EFFECT SENSOR IC
3055
Data Sheet
27680
DISCONTINUED PRODUCT
Shown for Reference Only
X
LOGIC
1
BUS
32
GROUND
SWITCH IN
Dwg. PH-005
MULTIPLEXED TWO-WIRE
HALL-EFFECT SENSOR ICs
The UGN3055U Hall-effect sensor is a digital magnetic sensing IC capable of communicating over a two-wire power/signal bus. Using a sequential addressing scheme, the device responds to a signal on the bus and returns the diagnostic status of the IC, as well as the status of each monitored external magnetic field. As many as 30 sensors can function on the same two-wire bus. This IC is ideal for multiple sensor applications where minimizing the wiring harness size is desirable or essential.
The device consists of high-resolution bipolar Hall-effect switching circuitry, the output of which drives high-density CMOS logic stages. These logic stages decode the address pulse and enable a response at the appropriate address. The combination of magnetic-field or switch-status sensing, low-noise amplification of the Hall-transducer output, and high-density decoding and control logic is made possible by the development of a new sensor BiMOS fabrication technology.
This unique magnetic sensing IC operates within specifications between -20°C and +85°C. Alternate magnetic and temperature specifications are available upon request. It is supplied in a 60 mil (1.54 mm) thick, three-pin plastic SIP. Each package is clearly marked with a two-digit decimal device address (xx).
Pinning is shown viewed from branded side.
ABSOLUTE MAXIMUM RATINGS
at T
= +25°C
A
Supply Voltage, V
Magnetic Flux Density, B............ Unlimited
Operating Temperature Range,
T
.......................... -20°C to +85°C
A
Storage Temperature Range,
.............................. -55°C to +150°C
T
S
Package Power Dissipation,
P
.................................... 750 mW
D
........................... 24 V
BUS
FEATURES
Complete Multiplexed Hall-Effect IC with
Simple Sequential Addressing Protocol
Allows Power and Communication Over a
Two-Wire Bus (Supply/Signal and Ground)
Up to 30 Hall-Effect Sensors Can Share a Bus
Sensor Diagnostic Capabilities
Magnetic-Field or Switch-Status Sensing
Low Power of BiMOS Technology Favors
Battery-Powered and Mobile Applications
Ideal for Automotive, Consumer, and Industrial Applications
Always order by complete part number: UGN3055U .
Page 2
3055
MULTIPLEXED TWO-WIRE HALL EFFECT SENSOR IC
OPERATIONAL CHARACTERISTIC over operating temperature range.
Electrical Limits Characteristics
Power Supply Voltage V Signal Current I Quiescent Current V
= 6 V I
BUS
= 9 V I
V
BUS
I
QH–IQL
Address Range Addr 1 30 — Clock Thresholds LOW to HIGH V
HIGH to LOW V
Hysteresis V Clock Period t Address LOW Voltage V Address HIGH Voltage V Power-On Reset Voltage V Settling Time V
= 9 V t
BUS
= 6 V t
V
BUS
Propagation Delay LOW to HIGH t
HIGH to LOW t
Pin 3 Input Resistance No Magnetic Field (V
Mag. Field Present (V
= HIGH) R
OUT
= LOW) R
OUT
Magnetic Characteristics
Magnetic Thresholds *Turn-On B
Turn-Off B
Hysteresis (B
*Alternate magnetic switch point specifications are available on request. Please contact the factory.
)B
OP–BRP
Symbol Min. Typ. Max. Units
BUS
S
QH
QL
I
Q
CLH
CHL
CHYS
CLK
L
H
RST
h
l
plh
phl
OUTH
OUTL
OP
RP
HYS
——15V 12 15 20 mA — 2.5 mA — 2.5 mA — 300 µA
8.5 V
6.5 V — 0.8 V
0.1 1.0 ms
V
RST
V
CLH
6V 9V
CHL
BUS
2.5 3.5 5.5 V
100 µs 100 µs
10 µs ——10µs 40 75 k ——50
50 150 300 G
-25 100 300 G
05075G
V V
115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000
W Copyright © 1988, 1991, Allegro MicroSystems, Inc.
Page 3
3055
A
MULTIPLEXED TWO-WIRE HALL EFFECT SENSOR IC
(±0.005” [0.13 mm] die placement)
ACTIVE AREA DEPTH
0.015"
0.38 mm
NOM
0.071"
1.80 mm
0.084"
2.13 mm
FUNCTIONAL BLOCK DIAGRAMSENSOR LOCATION
1
BUS
REG
COMP COMP
CLOCK
CMOS LOGIC
RESET
SWITCH IN
3
(OPTIONAL)
BRANDED SURFACE
1 32
Dwg. MH-002A
DEFINITION OF TERMS
Sensor Address
Each bus sensor has a factory-specified predefined address. At present, allowable sensor addresses are integers from 1 to 30.
LOW-to-HlGH Clock Threshold (V
Minimum voltage required during the positive-going transition to increment the bus address and trigger a diagnostic response from the bus sensors. This is also the maximum threshold of the on-chip comparator, which monitors the supply voltage, V
BUS
HlGH-to-LOW Threshold (VHL)
Maximum voltage required during the negative-going transition to trigger a
signal
current response from the bus sensors. This is also the maximum threshold of the on­chip comparator, which monitors the supply voltage, V
Bus HIGH Voltage (VH)
Bus HIGH voltage required for addressing. Voltage should be greater than V
CLH
.
Address LOW Voltage (VL)
Bus LOW Voltage required for addressing. Voltage should be greater than V
Bus Reset Voltage (V
and less than V
RST
)
RST
Voltage level required to reset individual sensors.
Sensor Quiescent Current Drain (IQ)
The current drain of bus sensors when active but not addressed. IQH is the maximum quiescent current drain when the sensor is not addressed and is at VH. IQL is the maximum quiescent current drain when the sensor is not addressed and is at VL.
)
CLH
.
BUS.
.
CHL
GROUND
2
Dwg. FH-009
Diagnostic Phase
Period on the bus when the address voltage is at VH. During this period, a correctly addressed sensor responds by increasing its current drain on the bus. This response from the sensor is called the diagnostic response and the bus current
increase
is called the diagnostic current.
Signal Phase
Period on the bus when the address voltage is at VL. During this period, a correctly addressed sensor that detects a magnetic field greater than magnetic Operate Point, BOP, responds by maintaining a current drain of IS on the bus. This response from the sensor is called the signal response and the bus current
increase
is called the signal current.
Sensor Address Response Current (IS)
Current returned by the bus sensors during the the
signal
responses of the bus sensors. This is accomplished
diagnostic
and
by enabling the constant current source (CCS).
Magnetic Operate Point (BOP)
Minimum magnetic field required to switch ON the Hall amplifier and switching circuitry of the addressed sensor. This circuitry is only active when the sensor is addressed.
Magnetic Release Point (BRP)
Magnetic field required to switch OFF the Hall amplifier and switching circuitry after the output has switched ON. This is due to magnetic memory in the switching circuitry. However, when a device is deactivated by changing the current bus address, all magnetic memory is lost.
Magnetic Hysteresis (B
HYS
)
Difference between the BOP and BRP magnetic field thresh­olds.
Page 4
3055
MULTIPLEXED TWO-WIRE HALL EFFECT SENSOR IC
ADDRESSING PROTOCOL
The device may be addressed by modulating the supply voltage as shown in Figure 1. A preferred addressing protocol is as follows: the bus supply voltage is brought down to 0 V so that all devices on the bus may be reset. The voltage is then raised to the address LOW voltage (VL) and the bus quiescent current is measured. The bus is then toggled between VL and VH (address HIGH voltage), with each positive transition representing an increment in the bus address. After each voltage transition, the bus current is moni­tored to check for diagnostic and signal responses from sensor ICs.
Sensor Addressing
When a sensor detects a bus address equal to its factory programmed address, it re-
FIGURE 1
BUS TIMING D1
V
H
V
CLH
V
CHL
BUS
VOLTAGE
V
L
V
RST
0
RESET
DIAGNOSTIC ADDRESS 01
DIAGNOSTIC ADDRESS 02
t
plh
sponds with an increase in its supply current drain (called IS during the HIGH portion of the address cycle). This response may be used as an indication that the sensor is alive and well on the bus and is also called the
diagnostic
response. If the sensor detects an ambient magnetic field, it also responds with IS during the low portion of the address cycle. This response from the sensor is called the
signal
response. When the next positive transition is detected, the sensor becomes disabled, and its contribution to the bus signal current returns to IQ.
Bus Current
Figure 1 displays the above described addressing protocol. The top trace represents the bus voltage transitions as controlled by the bus driver (see applications note for an optimal bus driver schematic). The second trace represents the bus current contribution of sensor (ad­dress 02). The detected its address on the bus; however, no
diagnostic
response from the sensor indicates that it
signal
response current is returned, which indicates that sufficient magnetic field is not de­tected at the chip surface. The third trace represents the current drain of sensor 03 when a magnetic field is detected. Note both the
nostic
and
signal
response from the sensor. The last trace represents
DIAGNOSTIC ADDRESS 03
t
phl
DIAGNOSTIC ADDRESS 04
DIAGNOSTIC
ADDRESS
n
RESET
DIAGNOSTIC
ADDRESS 01
diag-
SENSOR 02
CURRENT
WITH NO
MAGNETIC
FIELD
SENSOR 03
CURRENT
WITH
MAGNETIC
FIELD
TOTAL
BUS CURRENT
WITH
MAGNETIC
FIELD AT
SENSOR 03
I
S
I
QL
I
QH
0
I
S
I
QL
I
QH
0
I
S
SENSOR 01
NOT PRESENT
n • I
QL
n • I
QH
0
SENSOR 02 — DIAGNOSTIC CURRENT
SENSOR 03 — DIAGNOSTIC
AND SIGNAL CURRENTS
SENSOR 01
NOT PRESENT
Dwg. WH-005
115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000
Page 5
3055
MULTIPLEXED TWO-WIRE HALL EFFECT SENSOR IC
the overall bus current drain. When no sensors are addressed, the net bus current drain is the sum of quiescent currents of all sensors on the bus (for ‘n’ sensors, the bus quiescent current drain is n * IQ).
Bus Issues
At present, a maximum of 30 active sensors can coexist on the same bus, each with a different address. Address 0 is reserved for bus current calibration in software. This feature allows for fail-safe detection of signal current and eliminates detection problems caused by low signal current (IS), the opera­tion of sensors at various ambient tempera­tures, lot-to-lot variation of quiescent current, and the addition and replacement of sensors to the bus while in the field. Address 31 is designed to be inactive to allow for further address expansion of the bus (to 62 maxi­mum addresses). In order to repeat the address cycle, the bus must be reset as shown in Figure 1 by bringing the supply voltage to below V
. Sensors have been
RST
designed not to ‘wrap-around’.
Magnetic Sensing
The sensor IC has been designed to respond to an external magnetic field whose magnetic strength is greater than BOP. It accomplishes this by amplifying the output of an on-chip Hall transducer and feeding it into a threshold detector. In order that bus current is kept to a minimum, the transducer and amplification circuitry is kept powered down until the sensor is addressed. Hence, the magnetic status is evaluated only when the sensor is addressed.
APPLICATIONS NOTES
Magnetic Actuation
The left side of Figure 2 shows the wiring of the UGN3055U when used as a magnetic threshold detector. Pin 1 of the sensor is wired to the positive terminal of the bus, pin 2 is connected to the bus negative terminal, and
pin 3 has no connection.
Mechanical Actuation
The right side of Figure 2 shows the wiring of the UGN3055U when used to detect the status of a mechanical switch. In this case, pin 3 is connected to the positive terminal of the switch. The negative side of the switch is connected to the negative terminal of the bus. When the mechanical switch is closed (shorted to ground) and the correct bus address is detected by the IC, the sensor responds with a signal current. If the switch is open, only a diagnostic current is returned.
FIGURE 2
SENSOR CONNECTIONS
POSITIVE BUS SUPPLY
X
1 32
NC
BUS RETURN
X
1 32
SWITCH
Dwg. EH-004
External Switch Sensing
The third pin of the IC (pin 3) may be used to detect the status of an external switch when magnetic field sensing is not desired (and in the absence of a magnetic field). The allowable states for the switch are ‘open’ and ‘closed’ (shorted to sensor ground).
Page 6
3055
MULTIPLEXED TWO-WIRE HALL EFFECT SENSOR IC
FIGURE 3
BUS INTERCONNECTION
ADDRESS
RESET
UGN3055U AND UGS3055U
(POSITIVE) BUS SUPPLY
MULTIPLEXED TWO-WIRE HALL EF­FECT SENSOR IC
01 02 28 29 30
ANALOG OUT
MICROPROCESSOR
Bus Configuration
A maximum of 30 sensors may be connected across the same two wire bus as shown in Figure 3. It is recommended that the sensors use a dedicated digital ground wire to mini­mize the effects of changing ground potential (as in the case of chassis ground in the automotive industry).
The bus was not designed to require two-wire twisted-pair wiring to the sensors; however, in areas of extreme EMI (electro-magnetic interference), it may be advisable to install a small bypass capacitor (0.01 µF for example) between the supply and ground terminals of each sensor instead of using the more expensive wiring.
Bus Driver
It is recommended that the bus be controlled by microprocessor-based hardware for the following reasons:
• Sensor address information may be stored in ROM in the form of a look up table.
• Bus faults can be pinpointed by the microprocessor by comparing the diagnos­tic response to the expected response in the ROM look up table.
• The microprocessor, along with an A/D converter, can also be used to self cali­brate the quiescent currents in the bus and hence be able to easily detect a signal response.
INTERFACE
BUS RETURN
Dwg. EH-005
• The microprocessor can also be used to filter out random line noise by digitally filtering the bus responses.
• The microprocessor can easily keep track of the signal responses, initiate the appropriate action; e.g., light a lamp, sound an alarm, and also pinpoint the location of the signal.
Optimally, the microprocessor is used to control bus-driving circuitry that will accept TTL level inputs to drive the bus and will return an analog voltage representation of the bus current.
Interface Schematic
The bus driver is easily designed using a few operational amplifiers, resistors, and transistors. Figure 4 shows a schematic of a recom­mended bus driver circuit that is capable of providing 6 V to 9 V transitions, resetting the bus, and providing an analog measurement of the current for use by the A/D input of the microprocessor.
In Figure 4, the Address pin provides a TTL-compatible input that is used to control the Bus supply. A HIGH (5 V) input switches Q1 ON and sets the bus voltage to 6 V through the resistor divider R4, R5, and the Zener Z1. A LOW input switches OFF Q2 and sets the bus voltage to 9 V. This voltage is fed into the positive input of the opera­tional amplifier OP1 and is buffered and made available at Bus Supply (or sensor supply). Bus reset control is also available in the form of a TTL-compatible input. When this input, which is marked Reset, is HIGH, Q2 is switched ON and the positive input of the op amp is set to the saturation voltage of the transistor (approximately 0 V). This resets the bus.
A linear reading of the bus current is made possible by amplifying the voltage generated across R6 (which is I is a standard differential amplifier of gain R9/R7 (provided that R7 = R8, R9 = R10). The gain of the total transimpedance amplifier is given by:
V
= I
OUT
This voltage is available at the terminal marked Analog Out.
* R6 * R9/R7
BUS
* R6). The amplifier, OP2,
BUS
115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000
Page 7
3055
MULTIPLEXED TWO-WIRE HALL EFFECT SENSOR IC
FIGURE 4
BUS INTERFACE SCHEMATIC
Bus Control Software
The processing of the bus current (available at Analog Out) is best done by feeding it into the A/D input of a microprocessor. If the flexibility provided by a microprocessor is not desired, this signal could be fed into threshold detection circuitry; e.g., comparator, and the output used to drive a display.
Related References
1. G. AVERY, “Two Terminal Hall. Sensor,”
ASSIGNEE: Sprague Electric Company, North Adams, MA, United States. Patent number 4,374,333; Feb. 1983.
2. T. WROBLEWSKI and F. MEISTERFIELD, “Switch Status Monitoring System, Single Wire Bus, Smart Sensor Arrangement There Of,”
ASSIGNEE: Chrysler Motor Corporation, Highland Park, Ml,
United States. Patent number 4,677,308; June 1987.
+15 V
1 k
9 V Z
1
ADDRESS
RESET
10 k
5 k
5 k
R
0.001 µF
4
OP
20 k
R
5
Q
2
Q
1
1 k
Q
50
3
R
50 k R
8
BUS SUPPLY
6
50 k R
7
100 k
100 k
R
10
OP
1 32
R
2
X
NC
9
X
1 32
SWITCH
BUS RETURN
ANALOG OUT
1
Dwg. EH-003A
Page 8
3055
MULTIPLEXED TWO-WIRE HALL EFFECT SENSOR IC
0.181
0.176
0.560
MIN
Dimensions in Inches
(controlling dimensions)
0.183
0.178
0.086
MAX
1 2 3
0.063
0.059
0.018
0.015
45°
Dimensions in Millimeters
(for reference only)
4.65
4.52
4.60
4.47
2.18
MAX
14.22
MIN
1 2 3
1.60
1.50
45°
0.46
0.38
0.016
SEE NOTE
0.050
0.100
Dwg. MH-003C in
NOTES: 1. Tolerances on package height and width represent allowable mold offsets. Dimensions given are measured at the widest point (parting
line).
2. Exact body and lead configuration at vendor’s option within limits shown.
3. Height does not include mold gate flash.
4. Recommended minimum PWB hole diameter to clear transition area is 0.035” (0.89 mm).
5. Where no tolerance is specified, dimension is nominal.
6. Minimum lead length was 0.500” (12.70 mm). If existing product to the original specifications is not acceptable, contact sales office before ordering.
Allegro MicroSystems, Inc. reserves the right to make, from time to time, such departures from the
detail specifications as may be required to permit improvements in the design of its products.
The information included herein is believed to be accurate and reliable. However, Allegro MicroSystems, Inc. assumes no responsibility for its use; nor for any infringements of patents or other rights of third parties which may result from its use.
SEE NOTE
1.27
2.54
0.41
Dwg. MH-003C mm
115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000
Loading...