• Practical Secondary Side Control of
Isolated Power Supplies
• Provides a Self Regulating Bias
Supply From a High Input Voltage
Using an External N-Channel
Depletion Mode FET
• Onboard Precision, Fixed Gain,
Differential Current Sense Amplifier
• Wide Bandwidth Current Error
Amplifier
• 5V Reference
• High Current, Programmable Gm
Amplifier Optimized to Drive
Opto-couplers
DESCRIPTION
The UCC3839 provides the control functions for secondary side average
current mode control in isolated power supplies. Start up, pulse width
modulation and MOSFET drive must be accomplished independently on
the primary side. Communication from secondary to primary side is anticipated through an opto-isolator.
Accordingly, the UCC3839 contains a fixed gain current sense amplifier,
voltage and current error amplifiers, and a Gm type buffer/driver amplifier
for the opto-isolator. Additional housekeeping functions include a precision
5V reference and a bias supply regulator.
Power for the UCC3839 can be generated by peak rectifying the voltage of
the secondary winding of the isolation transformer. From this unregulated
voltage, the UCC3839’s bias supply regulator will generate its own 7.5V
bias supply using an external, N-channel, depletion mode FET.
The UCC3839 can be configured for traditional average current mode control where the output of the voltage error amplifier commands the current
error amplifier. It can also be configured for output voltage regulation with
average current mode short circuit current limiting, employing two parallel
control loops regulating the output voltage and output current independently.
Lead Temperature (Soldering, 10sec.) . . . . . . . . . . . . . +300°C
Currents are positive into, negative out of the specified terminal.
Consult Packaging Section of Databook for thermal limitations
and considerations of package.
UCC1839
UCC2839
UCC3839
CONNECTION DIAGRAMS
DIL-14, SOIC-14 (Top View)
J or N Package, D Package
Note 1: Guaranteed by design. Not 100% tested in production.
J = 25°C4.9555.05V
IREF = 0mA to 1mA, VLINE = 10V to 20V4.95.1V
= CS– = 0, IREF = 0
Unless otherwise specified, 0°C to 70°C for the UCC3839, –40°C to 85° for the
= 10V, RG = 400Ω. TA=TJ.
LINE
LINE = 10V to 40V77.58V
1.32mA
PIN DESCRIPTIONS
CA–: Current Error Amplifier Negative Input.
CAO: Current Error Amplifier Output. Output source cur-
rent is limited, and output sink current is guaranteed to
be greater than the VAO output source current. Current
loop compensation components are generally connected
to CAO and CA–.
CA+: Current Error Amplifier Positive Input.
CS–: Current Sense Amplifier Negative Input.
CSO: Current Sense Amplifier Output. Internally set gain
OUT/VIN = 8 VIN = 0V results in CSO = 1V.
V
CS+: Current Sense Amplifier Positive Input.
GM: Gm (transconductance) Programming Pin. Resistor
R
GM = 400Ω to GND.
GND: Chip Ground.
LED: Output of LED Driver. Connect LED from VDD pin
VA–: Voltage Error Amplifier Negative Input. Voltage Error Amplifier is internally referenced to 1.5V
VAO: Voltage Error Amplifier Output. In a two loop average current mode control configuration, VAO is connected to CA+ and is the current command signal. VAO
is internally clamped not to exceed 5V for short circuit
control. In a single loop voltage mode control configuration with a parallel average short circuit current control
loop, VAO is connected directly to CAO. Output source
current is limited, and output sink current is guaranteed
to be greater than the CAO output source current.
VDD: 7.5V Regulator output.Supply for most of the
chip. Minimum Decoupling Capacitance = 0.01µF
VGATE: External FET Gate Control Voltage.
APPLICATION INFORMATION
Fig. 1 shows a typical secondary side average current
mode controller configuration using the UCC3839. In this
configuration, output voltage is sensed and regulated by
the voltage error amplifier. Its output, VAO provides the
reference for the current error amplifier at the CA+ pin.
VAO can be connected to CA+ directly or through a resistive divider depending on the particular application requirements.
Average current mode control needs accurate output current information which is provided by a low value current
sense resistor. The voltage proportional to the converter’s output current is sensed and amplified by the
precision current sense amplifier of the chip. The
onboard current sense amplifier has a gain of 8 and is intended for differential sensing of the shunt voltage with a
common mode voltage range from 0V up to 5V. The output of the current sense amplifier, CSO is 1V for zero input which guarantees that the circuit can control currents
down to 0A.
The CSO signal is fed to the CA– input of the current error amplifier through a resistor. The current error amplifier takes the VAO and CSO signals and generates the
error signal for the pulse width modulator.
3
Page 4
APPLICATION INFORMATION (cont.)
Since the PWM function is located on the primary side of
the power converter the CAO signal must be sent across
the safety isolation boundary. The UCC3839 anticipates
an opto-coupler to provide isolation between primary and
secondary. Therefore, CAO drives a transconductance
amplifier that controls LED current in an opto-isolator.
During start up and when CAO exceeds 4V, the current
in the LED drops to zero. Maximum LED current is obtained during normal operation as CAO reaches its lowest potential. Its value is determined by the programming
resistor value from the GM pin to circuit GND.
An alternative secondary side controller configuration is
introduced in Fig. 2. In this circuit, the voltage and current control loops of the UCC3839 are connected parallel. It can be achieved by connecting the VAO and CAO
pins together. The error amplifier with the lower output
UCC1839
UCC2839
voltage controls the current in the opto-coupler providing
the feedback signal for the PWM section on the primary
side. Voltage regulation is still maintained by the voltage
error amplifier until a user programmable output current
is reached. At this time CAO will take control over the
Gm amplifier and the output current of the converter will
be regulated while the output voltage falls below its nominal value. This current level is set at the CA+ input by a
resistive divider from the 5V reference of the chip.
Since the chip is powered from a peak rectifier which
maintains the bias supply for the UCC3839 even under
short circuit conditions, both of these techniques can be
used to eliminate the short circuit runaway problem in
isolated power supplies using peak current mode control
on the primary side.
Figure 1. Secondary side average current mode controller.
4
UDG-97012
Page 5
APPLICATION INFORMATION (cont.)
UCC1839
UCC2839
UCC3839
Figure 2. Voltage mode with average current short circuit limit.
UDG-97014
Figure 3. Typical primary side circuit for use with secondary side average current mode controller.
T exas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty . Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICA TIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERST OOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright 1999, Texas Instruments Incorporated
Loading...