Datasheet UC2000-30GM-IU-V1 DataSheet (Pepperl Fuchs)

Page 1
Ultrasonic sensor UC2000-30GM-IU-V1
Technical data
General specifications
Sensing range 200 ... 2000 mm Unusable area 0 ... 200 mm Standard target plate 100 mm x 100 mm Transducer frequency approx. 175 kHz Response delay 100 ms
Indicators/operating means
Model Number
UC2000-30GM-IU-V1
Single head system
Features
• Analog current and voltage output
• 12 bit D/A transducer
• Evaluation limits can be taught-in
• Temperature compensation
• Compact design
• Plug connection
Diagrams
Characteristic response curve
Distance Y [m]
0.6
0.4
0.2
0.0
-0.2
-0.4
-0.6
-0.8
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
Curve 1: flat surface 100 mm x 100 mm Curve 2: round bar, Ø 25 mm
2
Y
X
1
Distance X [m]
LED yellow solid yellow: object in the evaluation range
LED red/green solid green: Power on green, flashing: program function,
Electrical specifications
Operating voltage U
Power consumption P
Output
B
0
Output type 1 current output 4 ... 20 mA
Resolution depending on the set evaluation range:
Deviation of the characteristic curve 0.2 % of full-scale value Repeat accuracy 0.1 % of full-scale value Load impedance current output: 500 Ohm
Temperature influence < 2 % of full-scale value ( 0.2 % / K without temperature
Standard conformity
Standards EN 60947-5-2
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 4-pin Protection degree IP65 Material
Housing High grade stainless steel Transducer epoxy resin/hollow glass sphere mixture; foam
Mass 175 g
Dimensions
5
yellow, flashing: program function evaluation limits, slope
object detected solid red: Connector removed red, flashing: error, program function object not detected
10 ... 30 V DC , ripple 10 %
SS
800 mW
1 voltage output 0 ... 10 V
0.172 mm , if evaluation range < 705 mm , evaluation range [mm] / 4096, if evaluation range > 705 mm
Voltage output: 1000 Ohm
compensation)
polyurethane, cover PBT
M30x1.5
36
114
22
LED
Temperature probe
Coded plug
Release date: 2013-02-26 15:42 Date of issue: 2013-02-26 030410_eng.xml
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
27.5
Pepperl+Fuchs Group •
1
Page 2
Ultrasonic sensor UC2000-30GM-IU-V1
Electrical Connection
Standard symbol/Connection:
(version IU)
1
(BN)
(BK)
U
Core colours in accordance with EN 60947-5-2.
4
2
(WH)
3
(BU)
+ U
B
4-20 mA
0-10 V
- U
B
Pinout
Connector V1
2
1
3
4
Accessories
BF 30
Mounting flange, 30 mm
BF 30-F
Mounting flange with dead stop, 30 mm
BF 5-30
Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mm
OMH-04
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mm
UVW90-M30
Ultrasonic -deflector
UVW90-K30
Ultrasonic -deflector
UC-30GM-PROG
Additional Information
Programmed analogue output function
Analogue function
1)
2)
Near distance
of evaluation
4 mA/ 0 V
20 mA/ 10 V
Far distance of evaluation
20 mA/10 V
4 mA/0 V
DA5-IU-2K-V
Process control and indication equipment
V1-G-2M-PVC
Cable socket, M12, 4-pin, PVC cable
V1-W-2M-PVC
Cable socket, M12, 4-pin, PVC cable
Description of the sensor functions
This ultrasonic sensor features a four-pole temperature/TEACH-IN plug, that can be connected in four different positions. These have the following significance.
Plug position Meaning
A1 TEACH-IN evaluation limit A1
A2 TEACH-IN evaluation limit A2
E2/E3 Switching: falling/rising ramp
T Temperature compensation
Description of the TEACH-IN procedure
- Remove temperature plug
- Cut and restore supply voltage (e.g. by removing and replacing unit plug)
TEACH-IN of evaluation limits A1 or A2
- Set object to desired evaluation limit
- Connect TEACH-IN plug in pos. A1 or A2
- Green LED flashes when object detected, red LED flashes when no object detected
- Pull the plug (the current object position is taught and stored when the plug is removed!!)
TEACH-IN of output function
- Connect TEACH-IN plug in pos. E2/E3
- The yellow LED indicates the output function E2: falling ramp
2
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group •
Release date: 2013-02-26 15:42 Date of issue: 2013-02-26 030410_eng.xml
Page 3
Ultrasonic sensor UC2000-30GM-IU-V1
E3: rising ramp
- Pull the plug when the desired function is activated, otherwise reconnect the TEACH-IN plug in pos. E2/E3
- Pull plug
Completing the TEACH-IN procedure
- Connect TEACH-IN plug in pos. T. Temperature compensation is now activated.
If the temperature plug has not been plugged in within 5 minutes, the sensor will return to normal mode without temperature compensation.
Default setting
A1: unusable area A2: nominal sensing range Mode of operation: rising ramp
LED Displays
Displays depending on position of temperature/ TEACH-IN plug
Green dual LED
Red dual LED
Yellow LED A1/
-
\
-
Yellow LED
-
A2/ -/
TEACH-IN evaluation limit A1 Object detected No object detected
flashes off
off flashes
flashes flashes
off off
TEACH-IN evaluation limit A2 Object detected No object detected
flashes off
off flashes
off off
flashes flashes
TEACH-IN mode of operation rising ramp falling ramp
Normal operation temperature compensated Plug pulled or shorted
Interference (e.g. compressed air) off flashes previous
1)
on, when object in evaluation range
2)
on, when object in detection range
on on
on off
off off
off on
flashes off
on/off
state
off flashes
1)
on/off
2)
previous state
Mounting conditions
If the sensor is installed in places where the operating temperature can fall below 0 °C, the BF30, BF30-F or BF 5-30 fixing clamp must be used.
LED-Window
LED
yellow
E2 E3
Evaluation limit 1
Dual-LED green/red
A1 A2
"Power on"/Disturbance
LED yellow
Evaluation limit 2
Release date: 2013-02-26 15:42 Date of issue: 2013-02-26 030410_eng.xml