Datasheet UC2000-30GM70S-UE2R2-V15 DataSheet (Pepperl Fuchs)

Page 1
Ultrasonic sensor UC2000-30GM70S-UE2R2-V15
Technical data
General specifications
Sensing range 100 ... 2000 mm Adjustment range 150 ... 2000 mm Dead band 0 ... 100 mm Standard target plate 100 mm x 100 mm Transducer frequency approx. 200 kHz Response delay 100 ms
Nominal ratings
Temperature drift ± 1.5 % of full-scale value
Model Number
UC2000-30GM70S-UE2R2-V15
Ultrasonic diffuse sensor with pivoting transducer
Features
• Analog output 0 ... 10 V
•1 switch output
• Synchronization options
• Temperature compensation
• Can be parameterized via the ULT­RA-PROG-IR software and inter­face (accessories)
Diagrams
Characteristic response curve
Distance Y [mm]
500
250
0
-250
-500 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000
Y
Curve 1: flat surface 100 mm x 100 mm Curve 2: round bar, Ø 25 mm
2
X
1
Distance X [mm]
Time delay before availability t
Limit data
Permissible cable length max. 300 m
Indicators/operating means
LED yellow switching state switch output LED green/yellow yellow: object in evaluation range
Potentiometer switch output adjustable
Electrical specifications
Rated operating voltage U Operating voltage U Ripple 10 % No-load supply current I
Interface
Interface type Infrared Mode point-to-point connection
Input/Output
Input/output type 1 synchronization connection, bidirectional ( Factory setting:
0 Level 3 V 1 Level 15 V Input impedance typ. 900 Number of sensors max. 10
Switching output
Output type 1 switch output PNP, NO ( NC contact programmable ) Default setting 150 ... 2000 mm ( adjustable via potentiometer ) Repeat accuracy R ± 3 mm Operating current I Switching frequency 4 Hz Switching hysteresis 20 mm ( programmable ) Voltage drop 3 V Off-state current 10 µA
Analog output
Output type 1 voltage output 0 ... 10 V , ascending/descending
Default setting rising ramp ; evaluation limit A1: 150 mm ; evaluation limit
Load resistor 2 k
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F) Shock resistance 30 g , 11 ms period Vibration resistance 10 ... 55 Hz , Amplitude ± 1 mm
Mechanical specifications
Connection type Connector M12 x 1 , 5-pin Degree of protection IP65 Material
Housing brass, nickel-plated
Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam Installation position any position Mass 170 g Construction type Cylindrical
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
B
L
v
e
0
125 ms
green: Teach-In
24 V DC 20 ... 30 V DC (including ripple)
50 mA
synchronized mode ) / Teach-In input
300 mA , short-circuit/overload protected
programmable
A2: 2000 mm
IEC 60947-5-2:2007 + A1:2012 EN 60947-5-7:2003 IEC 60947-5-7:2003
Release date: 2016-02-16 09:15 Date of issue: 2016-02-16 238400_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated
36 V
1
Page 2
Ultrasonic sensor UC2000-30GM70S-UE2R2-V15
Dimensions
M30 x 1.5
M12 x 1
10.5 88.5
126
74.4
Additional Information
Analog output operating mode
Rising ramp
Evaluation limit A1
Blind zone
2818
61
Evaluation range
Evaluation limit A2
Switching output operating mode
Window operation mode
Blind zone
switching
point 1
switching
point 2
h2h1
Electrical Connection
Pinout
Wire colors in accordance with EN 60947-5-2
1 BN 2 WH 3 BU 4 BK 5 GY
1
2
4
5
3
2
1
3
(brown) (white) (blue) (black) (gray)
L+
XI
Switch output
Analog output
L-
5
4
Release date: 2016-02-16 09:15 Date of issue: 2016-02-16 238400_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Page 3
Ultrasonic sensor UC2000-30GM70S-UE2R2-V15
Accessories
BF 30
Mounting flange, 30 mm
BF 5-30
Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mm
V15-G-2M-PUR
Female cordset, M12, 5-pin, PUR cable
UC-18/30GM-IR
Interface cable
ULTRA-PROG-IR
Configuration software for ultrasonic sensors
Description of Sensor Functions
Displays and Controls
The sensor has two potentiometers and two display LEDs.
LED 1 (yellow)
LED 2 (yellow)
LED 2 (green)
Potentiometer 1 Setting for switching point 1 of the switching
Potentiometer 2 Setting for switching point 2 of the switching
The potentiometer function described illustrates the default function. The function of the potentiometer can be altered using the ULTRA-PROG­IR software. As soon as a configuration has been changed, the potentiometer function selected using ULTRA-PROG-IR is activated.
On/off:
Switching state of switching output
Flashing:
points (switching point 2 < switching point 1). This state only occurs in window function ope­rating mode (2 switching points).
On/off:
and evaluation limit A2 in the analog evalua­tion range.
approx. 500 ms on: Off:
output.
output
Error when setting the switching
Object between evaluation limit A1
Range limit taught in
Normal mode
potentiometer 2
LED 1 yellow
potentiometer 1 temperature
LED 2
yellow / green
connector
sensor
Setting the Sensor Using the Potentiometers
The sensor is equipped with two potentiometers. These potentiometers are assigned to the switching output by default. The switching output operates in window mode by default (2 switching points). Potentiometer 1 is used to set the near switching point of the switching window. Poten­tiometer 2 is used to set the distant switching point of the switching window.
Note:
The function of the potentiometer can be altered using the ULTRA-PROG-IR software. As soon as a configuration has been changed, the poten­tiometer function selected using ULTRA-PROG-IR is activated.
Parameterization via ULTRA-PROG-IR
In order to be able to set the sensor parameters and adjust the sensor to the respective application, the sensor is able to communicate with a PC via the integrated infrared interface. The UC-18/30GM-IR interface cable is required to allow communication via this method. This cable is con­nected to an unused USB port on the PC.
UC-18/30GM-IR
The ULTRA-PROG-IR parameterization software is also required for setting the sensor parameters. The ULTRA-PROG-IR software can be downloaded for free from the website. The software allows all open parameters to be set, including:
- All trip points and switchi
- Output modes and behaviors
-Delay times
- Settings and setting ranges of the potentiometer
- Settings for teach-in and synchronization
- Definition of blind zones
- Sensor modes and measurement methods
- Filtering measurement values
The following service functions are also available:
- Observing and recording measurement values
- Diagnosing interference reflections
Sensor
Teach-in
The sensor is equipped with a function input (XI). In order to teach in a limit value, this sensor must be parameterized as the Teach-in input using the ULTRA-PROG-IR parameterization software. This parameterization software allows you to specify what limit value is taught in.
Release date: 2016-02-16 09:15 Date of issue: 2016-02-16 238400_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
3
Page 4
Ultrasonic sensor UC2000-30GM70S-UE2R2-V15
Note:
The Teach-in function is not activated when the sensor is delivered.
Description of the Teach-in process:
1. Position an object at the required distance.
2. Connect the Teach-in input to L-. The green LED lights up briefly after approx. 3 seconds. This indicates that the required distance has been successfully saved.
3. Disconnect the Teach-in input from L-.
Note:
If the Teach-in input remains connected to L-, the Teach-in process is repeated every 3 seconds.
Synchronization
The sensor features a function input (XI). Using the ULTRA-PROG-IR parameterization software, this function input can be configured as a syn­chronization input to suppress mutual interference from external ultrasonic signals. This is illustrated in the following description. If the synchronization input is not connected, the sensor operates with internally generated cycle pulses.
External synchronization
The sensor can be synchronized by applying external rectangular pulses. The pulse duration must be 100 µs. Each rising pulse edge sends an individual ultrasonic pulse. If the signal at the synchronization input is high, the sensor reverts to the normal, unsynchronized operating mode. If a low signal is applied to the synchronization input, the sensor switches to standby. In this operating mode, the last recorded output statuses are retained.
Internal synchronization
Common mode operation
Up to ten sensors can be synchronized with each other. To do this, the synchronization inputs of the individual sensors are connected to each other. When configured in this state, all of the sensors send the ultrasonic signals together at the same time. The cycle rate corresponds to the cycle rate of the sensor with the lowest rate.
Multiplex mode
Up to ten sensors can work in multiplex mode; i.e. the sensors send their ultrasonic signals in succession. This prevents the sensor signals inter­fering with each other. In multiplex mode, the synchronization inputs of all sensors are connected to each other. An address must also be assig­ned to each sensor using the ULTRA-PROG-IR parameterization software, and the number of sensors to be synchronized must be determined. To start multiplex mode, all sensors are commissioned together by switching on the power supply.
Release date: 2016-02-16 09:15 Date of issue: 2016-02-16 238400_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
4