Datasheet UB300-18GM40-U-V1 DataSheet (Pepperl Fuchs)

Page 1
Ultrasonic sensor UB300-18GM40-U-V1
Technical data
General specifications
Sensing range 35 ... 300 mm Adjustment range 50 ... 300 mm Dead band 0 ... 35 mm Standard target plate 100 mm x 100 mm Transducer frequency approx. 390 kHz Response delay approx. 50 ms
Indicators/operating means
LED green Power on
Model Number
UB300-18GM40-U-V1
Single head system
Features
•Short design, 40mm
• Function indicators visible from all directions
•Analog output 0...10V
• Measuring window adjustable
•Program input
• Temperature compensation
Diagrams
Characteristic response curve
Distance Y [mm]
100
1
50
0
3
2
LED yellow solid yellow: object in the evaluation range
LED red solid red: Error
Electrical specifications
Operating voltage U No-load supply current I
Input
Input type 1 program input
Output
Output type 1 analog output 0 ... 10 V Default setting evaluation limit A1: 50 mm evaluation limit A2: 300 mm Resolution 0.4 mm at max. sensing range Deviation of the characteristic curve ± 1 % of full-scale value Repeat accuracy ± 0.5 % of full-scale value Load impedance > 1 kOhm Temperature influence ± 1.5 % of full-scale value
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 4-pin Degree of protection IP67 Material
Housing brass, nickel-plated Transducer epoxy resin/hollow glass sphere mixture; foam polyurethane,
Mass 25 g
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated 36 V
B
0
yellow, flashing: program function, object detected
red, flashing: program function, object not detected
15 ... 30 V DC , ripple 10 % 20 mA
lower evaluation limit A1: -U A2: +4 V ... +U input impedance: > 4.7 k, pulse duration: 1 s
cover PBT
IEC 60947-5-2:2007 + A1:2012 EN 60947-5-7:2003 IEC 60947-5-7:2003
B
SS
... +1 V, upper evaluation limit
B
-50
-100 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700
Curve 1: flat surface 100 mm x 100 mm Curve 2: flat surface 10 mm x 10 mm Curve 3: round bar, Ø 25 mm
Release date: 2016-04-25 09:26 Date of issue: 2016-04-25 220365_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Distance X [mm]
Y
X
1
Page 2
Ultrasonic sensor UB300-18GM40-U-V1
Dimensions
M18 x 1
Additional Information
Programming the analog output mode
Rising ramp A1 < A2:
A1
Falling ramp
M12 x 1
A2 < A1:
A2
24
24.5
39.2
4
LED
10
50.2
object range
A2
A1
Electrical Connection
Standard symbol/Connections:
(version U)
U
Core colors in accordance with EN 60947-5-2.
Pinout
Wire colors in accordance with EN 60947-5-2
1 BN 2 WH 3 BU 4 BK
1 (BN)
2 (WH)
4 (BK)
3 (BU)
2
1
3
(brown) (white) (blue) (black)
+ U
B
Teach input
Analog output
- U
B
4
Release date: 2016-04-25 09:26 Date of issue: 2016-04-25 220365_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Page 3
Ultrasonic sensor UB300-18GM40-U-V1
Accessories
UB-PROG2
Programming unit
OMH-04
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mm
BF 18
Mounting flange, 18 mm
BF 18-F
Mounting flange with dead stop, 18 mm
BF 5-30
Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mm
V1-G-2M-PVC
Female cordset, M12, 4-pin, PVC cable
V1-W-2M-PUR
Female cordset, M12, 4-pin, PUR cable
Adjusting the evaluation limits
The ultrasonic sensor features an analogue output with two teachable evaluation limits. These are set by applying the supply voltage -U indicate whether the sensor has recognised the target during the TEACH-IN procedure. The lower evaluation limit A1 is taught with -U
Two different output functions can be set:
1. Analogue value increases with rising distance to object (rising ramp)
2. Analogue value falls with rising distance to object (falling ramp)
TEACH-IN rising ramp (A2 > A1)
- Position object at lower evaluation limit
- TEACH-IN lower limit A1 with - U
- Position object at upper evaluation limit
- TEACH-IN upper limit A2 with + U
TEACH-IN falling ramp (A1 > A2):
- Position object at lower evaluation limit
- TEACH-IN lower limit A2 with + U
- Position object at upper evaluation limit
- TEACH-IN upper limit A1 with - U
Default setting
A1: unusable area A2: nominal sensing range Mode of operation: rising ramp
LED Displays
or +UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs
B
, A2 with +UB.
B
B
B
B
B
Displays in dependence on operating mode Red LED Yellow LED
TEACH-IN evaluation limit
Object detected No object detected Object uncertain (TEACH-IN invalid)
off flashes on
flashes off
off Normal mode (evaluation range) off on Fault on previous state
Installation conditions
If the sensor is installed at places, where the environment temperature can fall below 0 °C, for the sensors fixation, one of the mounting flanges BF18, BF18-F or BF 5-30 must be used. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread. If a fixation at the front end of the threaded housing is required, plastic nuts with centering ring (accessories) must be used.
Release date: 2016-04-25 09:26 Date of issue: 2016-04-25 220365_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
3