Datasheet UB300-18GM40-E5-V1 DataSheet (Pepperl Fuchs)

Page 1
Ultrasonic sensor UB300-18GM40-E5-V1
Technical data
General specifications
Sensing range 35 ... 300 mm Adjustment range 50 ... 300 mm Dead band 0 ... 35 mm Standard target plate 100 mm x 100 mm Transducer frequency approx. 390 kHz Response delay approx. 50 ms
Indicators/operating means
LED green Power on
Model Number
UB300-18GM40-E5-V1
Single head system
Features
•Short design, 40mm
• Function indicators visible from all directions
• Switch output
• 5 different output functions can be set
•Program input
• Temperature compensation
Diagrams
Characteristic response curve
Distance Y [mm]
100
1
50
LED yellow indication of the switching state
LED red solid red: Error
Electrical specifications
Operating voltage U No-load supply current I
Input
Input type 1 program input
Output
Output type 1 switching output E5, PNP NO/NC, programmable Rated operating current I Default setting Switch point A1: 50 mm Switch point A2: 300 mm Voltage drop U Repeat accuracy 1 % Switching frequency f 13 Hz Range hysteresis H 1 % of the set operating distance Temperature influence ± 1.5 % of full-scale value
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector plug M12 x 1 , 4-pin Degree of protection IP67 Material
Housing brass, nickel-plated Transducer epoxy resin/hollow glass sphere mixture; foam polyurethane,
Mass 25 g
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007+A1:2012
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated 36 V
B
0
e
d
flashing: program function object detected
red, flashing: program function, object not detected
10 ... 30 V DC , ripple 10 % 20 mA
operating distance 1: -U ... +U
B
input impedance: > 4,7 k program pulse: 1 s
200 mA , short-circuit/overload protected
3 V
cover PBT
IEC 60947-5-2:2007 + A1:2012
SS
... +1 V, operating d istance 2: +6 V
B
0
-50
-100 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700
Curve 1: flat surface 100 mm x 100 mm Curve 2: flat surface 10 mm x 10 mm Curve 3: round bar, Ø 25 mm
Release date: 2016-04-25 09:29 Date of issue: 2018-08-31 220357_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
3
2
Distance X [mm]
Y
X
1
Page 2
Ultrasonic sensor UB300-18GM40-E5-V1
Dimensions
M18 x 1
Additional Information
Programmable output modes
1. Window mode, normally open mode A1 < A2:
A1
2. Window mode, normally closed mode
M12 x 1
24
24.5
39.2
4
LED
10
50.2
A2 < A1:
A2
3. One switch point, normally open mode A1 -> ∞:
A2
4. One switch point, normally closed mode A2 -> :
A1
5. A1 -> ∞, A2 -> ∞: Object presence detection mode Object detected: Switch output closed No object detected: Switch output open
object distance
A2
A1
Electrical Connection
Standard symbol/Connections:
(version E5, pnp)
U
Core colours in accordance with EN 60947-5-2.
Pinout
Wire colors in accordance with EN 60947-5-2
1 BN 2 WH 3 BU 4 BK
1 (BN)
2 (WH)
4 (BK)
3 (BU)
2
1
3
(brown) (white) (blue) (black)
+ U
B
Teach input
Switch output
- U
B
4
Release date: 2016-04-25 09:29 Date of issue: 2018-08-31 220357_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Page 3
Ultrasonic sensor UB300-18GM40-E5-V1
Accessories
UB-PROG2
Programming unit
OMH-04
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mm
BF 18
Mounting flange, 18 mm
BF 18-F
Plastic mounting adapter, 18 mm
BF 5-30
Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mm
V1-G-2M-PVC
Female cordset, M12, 4-pin, PVC cable
V1-W-2M-PUR
Female cordset, M12, 4-pin, PUR cable
Adjusting the switching points
The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage
-U
or +UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs indicate whe-
B
ther the sensor has recognised the target during the TEACH-IN procedure. Switching point A1 is taught with -U
Five different output functions can be set
1. Window mode, normally-open function
2. Window mode, normally-closed function
3. one switching point, normally-open function
4. one switching point, normally-closed function
5. Detection of object presence
TEACH-IN window mode, normally-open function
- Set target to near switching point
- TEACH-IN switching point A1 with -U
B
- Set target to far switching point
- TEACH-IN switching point A2 with +U
B
TEACH-IN window mode, normally-closed function
- Set target to near switching point
- TEACH-IN switching point A2 with +U
B
- Set target to far switching point
- TEACH-IN switching point A1 with -U
B
TEACH-IN switching point, normally-open function
- Set target to near switching point
- TEACH-IN switching point A2 with +U
B
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A1 with -U
B
TEACH-IN switching point, normally-closed function
- Set target to near switching point
- TEACH-IN switching point A1 with -U
B
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A2 with +U
B
TEACH-IN detection of objects presence
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A1 with -U
- TEACH-IN switching point A2 with +U
B
B
, A2 with +UB.
B
LED Displays
Displays in dependence on operating mode Red LED Yellow LED
TEACH-IN switching point:
Object detected No object detected Object uncertain (TEACH-IN invalid)
off
flashes
On
flashes
off
off Normal operation off Switching state Fault on Previous state
Installation conditions
If the sensor is installed at places, where the environment temperature can fall below 0 °C, for the sensors fixation, one of the mounting flanges BF18, BF18-F or BF 5-30 must be used. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread. If a fixation at the front end of the threaded housing is required, plastic nuts with centering ring (accessories) must be used.
Release date: 2016-04-25 09:29 Date of issue: 2018-08-31 220357_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
3
Page 4
Ultrasonic sensor UB300-18GM40-E5-V1
Release date: 2016-04-25 09:29 Date of issue: 2018-08-31 220357_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
4
Loading...