80C186EC/188EC, 80L186EC/188EC
AC SPECIFICATIONS
AC CharacteristicsÐ80C186EC-20/80C186EC-13
Symbol Parameter Min Max Min Max Unit Notes
INPUT CLOCK 20 MHz 13 MHz
TF CLKIN Frequency 0 40 0 26 MHz 1
TC CLKIN Period 25
%
38.5
%
ns 1
TCH CLKIN High Time 10
%
12
%
ns 1, 2
TCL CLKIN Low Time 10
%
12
%
ns 1, 2
TCR CLKIN Rise Time 1 10 1 10 ns 1, 3
TCF CLKIN Fall Time 1 10 1 10 ns 1, 3
OUTPUT CLOCK
T
CD
CLKIN to CLKOUT Delay 0 17 0 23 ns 1, 4
T CLKOUT Period 2 * TC 2 * TC ns 1
T
PH
CLKOUT High Time (T/2)b5 (T/2)a5 (T/2)b5 (T/2)a5ns 1
T
PL
CLKOUT Low Time (T/2)b5 (T/2)a5 (T/2)b5 (T/2)a5ns 1
T
PR
CLKOUT Rise Time 1616ns1,5
TPFCLKOUT Fall Time 1616ns1,5
OUTPUT DELAYS
T
CHOV1
ALE, S2:0, DEN, DT/R, 3 20 3 25 ns 1,4,6,7
BHE
(RFSH), LOCK, A19:16
T
CHOV2
GCS7:0, LCS, UCS, 3 23 3 30 ns 1,4,6,8
RD
,WR, NCS, WDTOUT
T
CLOV1
BHE (RFSH), DEN, LOCK, RESOUT, 3 20 3 25 ns 1, 4, 6
HLDA, T0OUT, T1OUT
T
CLOV2
RD,WR, GSC7:0, LCS, UCS, AD15:0 3 23 3 30 ns 1, 4, 6
(AD7:0, A15:8), NCS
, INTA, S2:0, A19:16
T
CHOF
RD,WR, BHE (RFSH), DT/R, LOCK, 025030ns1
S2:0
, A19:16
T
CLOF
DEN, AD15:0 (AD7:0, A15:8) 0 25 0 30 ns 1
INPUT REQUIREMENTS
T
CHIS
TEST, NMI, T1IN, T0IN, READY, 10 10 ns 1, 9
CTS1:0
, BCLK1:0, P3.4, P3.5
T
CHIH
TEST, NMI, T1IN, T0IN, READY, 3 3 ns 1, 9
CTS1:0
, BCLK1:0, P3.4, P3.5
T
CLIS
AD15:0 (AD7:0), READY 10 10 ns 1, 10
T
CLIH
AD15:0 (AD7:0), READY 3 3 ns 1, 10
T
CLIS
HOLD, RESIN, PEREQ, ERROR, DRQ3:0 10 10 ns 1, 9
T
CLIH
HOLD, RESIN, REREQ, ERROR, DRQ3:0 3 3 ns 1, 9
NOTES:
1. See AC Timing Waveforms, for waveforms and definition.
2. Measure at V
IH
for high time, VILfor low time.
3. Only required to guarantee I
CC
. Maximum limits are bounded by TC,TCHand TCL.
4. Specified for a 50 pF load, see Figure 14 for capacitive derating information.
5. Specified for a 50 pF load, see Figure 15 for rise and fall times outside 50 pF.
6. See Figure 15 for rise and fall times.
7. T
CHOV1
applies to BHE (RFSH), LOCK and A19:16 only after a HOLD release.
8. T
CHOV2
applies to RD and WR only after a HOLD release.
9. Setup and Hold are required to guarantee recognition.
10. Setup and Hold are required for proper operation.
32